ODB++ Design Format Specification
ODB++ Design Format Specification
Release 8.1 Update 2 February 2020
Unpublished work. © Siemens 2020
This document contains information that is confidential and proprietary to Mentor Graphics Corporation, Siemens Industry Software Inc., or their affiliates (collectively, "Siemens"). The original recipient of this document may duplicate this document in whole or in part for internal business purposes only, provided that this entire notice appears in all copies. In duplicating any part of this document, the recipient agrees to make every reasonable effort to prevent the unauthorized use and distribution of the confidential and proprietary information.
This document is for information and instruction purposes. Siemens reserves the right to make changes in specifications and other information contained in this publication without prior notice, and the reader should, in all cases, consult Siemens to determine whether any changes have been made.
The terms and conditions governing the sale and licensing of Siemens products are set forth in written agreements between Siemens and its customers. End User License Agreement - You can print a copy of the End User License Agreement from: mentor.com/eula.
No representation or other affirmation of fact contained in this publication shall be deemed to be a warranty or give rise to any liability of Siemens whatsoever.
SIEMENS MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS MATERIAL INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF INTELLECTUAL PROPERTY.
SIEMENS SHALL NOT BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL OR PUNITIVE DAMAGES, LOST DATA OR PROFITS, EVEN IF SUCH DAMAGES WERE FORESEEABLE, ARISING OUT OF OR RELATED TO THIS PUBLICATION OR THE INFORMATION CONTAINED IN IT, EVEN IF SIEMENS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
LICENSE RIGHTS APPLICABLE TO THE U.S. GOVERNMENT : This document explains the capabilities of commercial products that were developed exclusively at private expense. If the products are acquired directly or indirectly for use by the U.S. Government, then the parties agree that the products and this document are considered "Commercial Items" and "Commercial Computer Software" or "Computer Software Documentation," as defined in 48 C.F.R. §2.101 and 48 C.F.R. §252.227-7014(a)(1) and (a)(5), as applicable. Software and this document may only be used under the terms and conditions of the End User License Agreement referenced above as required by 48 C.F.R. §12.212 and 48 C.F.R §227.7202. The U.S. Government will only have the rights set forth in the End User License Agreement, which supersedes any conflicting terms or conditions in any government order document, except for provisions which are contrary to applicable mandatory federal laws.
TRADEMARKS: The trademarks, logos and service marks ("Marks") used herein are the property of Siemens or other parties. No one is permitted to use these Marks without the prior written consent of Siemens or the owner of the Marks, as applicable. The use herein of third party Marks is not an attempt to indicate Siemens as a source of a product, but is intended to indicate a product from, or associated with, a particular third party. A list of Siemens' trademarks may be viewed at: www.plm.automation.siemens.com/global/en/legal/trademarks.html and mentor.com/trademarks.
The registered trademark Linux ® is used pursuant to a sublicense from LMI, the exclusive licensee of Linus Torvalds, owner of the mark on a world-wide basis.
Support Center: support.sw.siemens.com Send Feedback on Documentation: support.sw.siemens.com/doc_feedback_form
Table of Contents
| Chapter 1 ODB++ Design Format Specification . . . . . . . . . . . | 13 | |----------------------------------------------------------------------------------------------|------| | Changes to the ODB++ Design Format Since V8.0 | 14 | | File System . . . . . . . . . . . . . . . . . . . . . . . . | 22 | | . . . . . . . Legal Entity Names . . . . . . . . . . . . . . . . . . . . . . . . | 22 | | . Units of Measurement . . . . . . . . . . . . . . . . . . . . . . . | 23 | | ODB++ Attributes . . . . . . . . . . . . . . . . . . . . . . . . . . | 27 | | Attribute Classes. . . . . . . . . . . . . . . . . . . . . . . . . . | 27 | | Attribute Value Assignment . . . . . . . . . . . . . . . . . | 28 | | Unique ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 30 | | Format Definition . . . . . . . . . . . . . . . . . . . . . . . . . . | 31 | | Extensible Content. . . . . . . . . . . . . . . . . . . . . . . . . . | 31 | | Large File Compression. . . . . . . . . . . . . . . . . . . . . . | 31 | | Structured Text Files . . . . . . . . . . . . . . . . . . . . . . . . | 32 | | Line Record Text Files . . . . . . . . . . . . . . . . . . . . . . | 33 | | Coordinates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 34 | | Angles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 34 | | Rotation and Mirroring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 34 | | Symbols . . . . . . . . . . . . . . . . . . . . . | 36 | | Standard Symbols . . . . . . . . . . . . . . . . . . . . . . . . . | 36 | | User-Defined Symbols . . . . . . . . . . . . . . . . . . . . . | 37 | | Lines and Arcs Drawn with Symbols . . . . . . . . . . | 38 | | Surfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 38 | | Geometric Entities . . . . . . . . . . . . . . . . . . . . . . . . . . | 39 | | Self-Intersecting Polygons (SIP) . . . . . . . . . . . . . . . | 40 | | Component Variants . . . . . . . . . . . . . . . . . . . . . . . . | 41 | | Chapter 2 | | | Product Model Tree . . . . . . . . . . . . . . . . . . . . . . . . . | 43 | | <product_model_name> . . . . . . . . . . . . . . . . . . . . . | 43 | | <product_model_name>/steps. . . . . . . . . . . . . . . . . | 44 | | <product_model_name>/steps/<step_name>/layers | 46 | | Chapter 3 | | | Product Model Entities . . . . . . . . . . . . . . . . . . . . . . | 47 | | ext (Extension). . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 47 | | fonts (Fonts Used in Product Model). . . . . . . . . . . . | 48 | | fonts/standard (Standard Font) . . . . . . . . . . . . . . . | 48 | | input (Input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 50 | | matrix (Product Model Matrix) . . . . . . . . . . . . . . . . | 51 | | matrix/stackup.xml (Stackup). . . . . . . . . . . . . . . . | 52 | | Structure of the Stackup File . . . . . . . . . . . . . . . | 53 |
Table of Contents
| matrix/matrix (Matrix) . . . . . . . | 62 | |-------------------------------------------------------------------------------------------------------------------------------------------------|---------| | . . . . . . . . . . . . . . . . Fields in the STEP Array of a Matrix File . . . . . . . | 65 | | Fields in the LAYER Array of a Matrix File . . . . . | 65 | | Recommended Buildup . . . . . . . . . . . . . . . . . . . . | 69 | | Layer Subtypes. . . . . . . . . . . . . . . . . . . . . . . . . . . | 70 | | . misc (Miscellaneous) . . . . . . . . . . . . . . . . . . . . . . . . . . | 76 | | misc/attrlist (Product Model Attribute List) . . . | 76 | | . . . . misc/last_save (Last Time Product Model Saved) . . | 77 | | misc/info (Basic Product Model Information) . . . . . | 77 | | misc/metadata.xml (Metadata) . . . . . . . . . . . . . . . . . | 79 | | Structure of the Metadata File . . . . . . . . . . . . . . . . | 79 | | Metadata Sections. . . . . . . . . . . . . . . . . . . . . . . . . | 81 | | Metadata Types . . . . . . . . . . . . . . . . . . . . . . . . . . . | 82 | | Attributes of a Metadata Node . . . . . . . . . . . . . . . . | 82 | | Collective Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . | 83 | | misc/sysattr.* (Attribute Definition). . . . . . . . . . . . . . . | 86 | | BOOLEAN Attribute Definition . . . . . . . . . . . | 87 | | TEXT Attribute Definition. . . . . . . . . . . . . . . . . . . | 88 | | OPTION Attribute Definition. . . . . . . . . . . . . . . . . | 88 | | INTEGER Attribute Definition . . . . . . . . . . . . . . . | 89 | | FLOAT Attribute Definition . . . . . . . . . . . . . . . . . | 90 | | misc/userattr (User Attribute Definition) . . . . . . . . . steps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 92 93 | | symbols (User-Defined Symbols) . | 94 | | . . . . . . . . . . . . . . . <symbol_name>/attrlist (Symbol Attribute List) . . . | 94 | | <symbol_name>/features (Symbol Features) . . . . . | 95 | | user (User) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 95 | | wheels (Gerber and Tool Wheels) . . . . . . . . . . . . . . . | 96 | | <wheel_name>/attrlist (Wheel Attribute List) . . . . . | 96 | | <wheel_name>/dcodes (Dcodes) . . . . . . . . . . . . . . . | 96 | | Chapter 4 | | | Step Entities. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 99 | | <step_name>/attrlist (Step Attribute List) . . . . . . . . . | 100 | | <step_name>/boms (Bill of Materials) . . . . . . . . . . . | 101 | | <bom_name>/bom (Bill Of Materials). . . . . . . . . . | 101 | | <bom_name>/files (Source Files). . . . . . . . . . . . . . . | 106 | | <step_name>/eda (Electronic Design Automation). . . | 108 | | eda/data (EDA Data). . . . . . . . . . . . . . . . . . . . . . . . . | 109 | | HDR -File Header Record . . . . . . . . . . . . . . . . | 111 | | . LYR -Layer Names Record . . . . . . . . . . . . . . . | 112 | | PRP -Property Record. . . . . . . . . . . . . . . . . . . . | 112 | | @and &-Net Attribute Lookup Table Records. | 112 | | NET -Electrical Net Record . . . . . . . . . . . . . . . . | 114 | | SNT- Subnet Record . . . . . . . . . . . . . . . . . . . . . . | 115 | | FID -Feature ID Record . . . . . . . . . . . . . . . . . . . . | 116 | | PKG -Package Record . . . . . . . . . . . . . . . . . . . PIN -Pin Record . . . . . . . . . . . . . . . . . . . . . . . . . | 116 117 |
| FGR -Feature Group Record. . . . . . . . . . . . . . . . . . . . . . | 118 | |--------------------------------------------------------------------------------------------|-------| | RC, CR, SQ, CT, OB, OS, OC, OE, CE -Outline Records | 118 | | eda/shorts (Electrical Intention Short Net) . . . . . . . . . . . . . . | 120 | | LYR -Layer Names in the Shorts File . . . . . . . . . . . | 121 | | . . . FID-Feature ID Record in the Shorts File . . . . . . . . . . . . | 122 | | SRT -Electrical Intention Short Net Record. . . . . . . . . . | 122 | | eda/hdi_netlist (HDI Netlist) . . . . . . . . . . . . . . | 126 | | . . . . . . . . . . <step_name>/impedance.xml (Impedance). . . . . . . . . . . . . . . | 132 | | Structure of the Impedance File . . . . . . . . . . . . . . . . . . . . . . | 133 | | <step_name>/layers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 134 | | <step_name>/netlists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 135 | | cadnet/netlist (cadnet) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 135 | | refnet/netlist (Reference) . . . . . . . . . . . . . . . . . . . . . . . . . . . | 141 | | <step_name>/profile (Outline Shape of Step) . . . . . . . . . . . . . | 141 | | <step_name>/stephdr (Step Header) . . . . . . . . . . . . . . . . . . . . | 143 | | <step_name>/zones (Matrix Broken Into Sections) . . . . . . . . | 145 | | Chapter 5 | | | Layer Entities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 151 | | <layer_name>/attrlist (Layer Attribute List) . . . . . . . . . . . . . . | 152 | | <layer_name>/components (Components) . . . . . . . . . . . . . . . | 153 | | @and &-Component Attribute Lookup Table . . . . . . . . | 155 | | CMP -Component Record. . . . . . . . . . . . . . . . . . . . . . . . . | 157 | | PRP -Component Property Record . . . . . . . . . . . . . . . . . . | 157 | | TOP -Component Toeprint Record. . . . . . . . . . . . . . . . . . | 158 | | BOMDescription Records . . . . . . . . . . . . . . . . . . . . . . . . . . | 158 | | <layer_name>/dimensions (Dimensions) . . . . . . . . . . . . . . . . | 161 | | Global Parameters for Dimensions. . . . . . . . . . . . . . . . . . . . | 164 | | PARAMETERS Array Structure . . . . . . . . . . . . . . . . . . . . . | 165 | | DIMENSION Array Structure . . . . . . . . . . . . . . . . . . . . . . . | 166 | | PAPER Array Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 167 | | TEXT Array Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 168 | | <layer_name>/features (Graphic Features) . . . . . . . . . . . . . . . | 170 | | UNITS -Measurement Units . . . . . . . . . . . . . . . . . . . . . . . | 172 | | ID -Unique ID (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . | 173 | | F -Number of Features (Optional). . . . . . . . . . . . . . . . . . . | 174 | | $ -Feature Symbol Names Section . . . . . . . . . . . . | 174 | | . . . . . . @and &-Feature Attribute Lookup Table. . . . . . . . . . . . | 174 | | L -Line Records. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 176 | | P -Pad Records . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 176 | | A -Arc Records . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 179 | | T -Text Records. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 180 | | B -Barcode Records . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 183 | | S -Surface Records . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 185 | | <layer_name>/notes (Electronic Notes) . . . . . . . . . . . . . . . . . | 188 | | <layer_name>/profile (Outline Shape of Layer) . . . . . . . . . . . . . . . . . | 188 | | <layer_name>/tools (Drill Tools) . . . . . . . . . . . . . . . . | 191 |
| Appendix A | | |--------------------------------------------------------------------------------------------------------------------------|-----| | Standard ODB++ Symbols. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 195 | | Basic Standard Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . | 195 | | . . . . . . . . . . . . . . Symbols Suitable for Solder Stencil Design . . . . . . . . . . . . . . . . . . . . . . . . . | 210 | | Other Symbol Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 212 | | Rotated Standard Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 212 | | . . . . . Rounded/Chamfered Rectangles. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 212 | | Corner Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 213 | | . . . . Obsolete Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 213 | | Appendix B | | | System Attributes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 215 | | ODB++ System Attributes - Alphabetical List . . . . . . . . . . . . . . . . . . . . . . . | 215 | | ODB++ System Attributes by Class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 271 | | Product (sysattr) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 271 | | . DFM (sysattr.dfm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 276 | | . . . . Fabrication (sysattr.fab) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 279 | | Assembly (sysattr.assy) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 281 | | Test (sysattr.test). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 283 | | Generic (sysattr.gen). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 284 | | Appendix C | | | Standard Font . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 285 | | Appendix D | | | Metadata Content, Example, and Schema . . . . . . . . . . . . . . . . . . . . . . . . . . | 299 | | Metadata Content. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 300 | | Header Metadata Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 300 | | . . Requirements Metadata Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 301 | | Manufacturing Metadata Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 306 | | Assembly Metadata Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 310 | | Final Metadata Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 311 | | Metadata Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 312 | | Metadata Schema. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 316 | | Appendix E | | | Stackup Schema . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 327 | | StackupFile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 331 | | StackupFile/EdaData . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 332 | | . . . . . StackupFile/EdaData/Specs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 334 | | . . . . . StackupFile/EdaData/Specs/Spec . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 335 | | StackupFile/EdaData/Specs/Spec/Material . . . . . . . . . . . . . . . . . . . . . . . . . . | 336 | | StackupFile/EdaData/Specs/Spec/Material/Dielectric. . . . . . . . . | 337 | | . . . . . . . . . StackupFile/EdaData/Specs/Spec/Material/Dielectric/Properties . . . . . . . . . | 339 | | StackupFile/EdaData/Specs/Spec/Material/Dielectric/Properties/Property . | 340 | | StackupFile/EdaData/Specs/Spec/Material/Conductor . . . . . . . . . . . . . . . . . | 342 | | StackupFile/EdaData/Specs/Spec/Material/Conductor/Properties . . . . . . . . | 344 | | StackupFile/EdaData/Specs/Spec/Material/Conductor/Properties/Property . | 345 |
| StackupFile/EdaData/Specs/Spec/Material/Default_Thickness . . . . . . . . . . . . . . . . . . . . . . | 347 | |-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------| | StackupFile/EdaData/Specs/Spec/Impedance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 348 | | StackupFile/EdaData/Specs/Spec/Impedance/Single_Ended . . . . . . . . . . . . . . . . . . . . . . . . | 351 | | StackupFile/EdaData/Specs/Spec/Impedance/Single_Ended/TraceWidth . . . . . . . . . . . . . . | 353 | | StackupFile/EdaData/Specs/Spec/Impedance/Single_Ended/RefPlane . . . . . | 355 | | . . . . . . . . . . . StackupFile/EdaData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide. . . | 356 | | . . . . . StackupFile/EdaData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide/TraceWidth 358 | . . . . . StackupFile/EdaData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide/TraceWidth 358 | | StackupFile/EdaData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide/Spacing. StackupFile/EdaData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide/CoplanarSpac . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 360 | | ing . | 361 | | StackupFile/EdaData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide/CoplanarTrac eWidth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | | | . StackupFile/EdaData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide/RefPlane | 362 364 | | StackupFile/EdaData/Specs/Spec/Impedance/Differential_Edge_Coupled . . . . . . . . . . . . . | 365 | | StackupFile/EdaData/Specs/Spec/Impedance/Differential_Edge_Coupled/TraceWidth . . . . . | 367 | | StackupFile/EdaData/Specs/Spec/Impedance/Differential_Edge_Coupled/Spacing . . . . | 369 | | StackupFile/EdaData/Specs/Spec/Impedance/Differential_Edge_Coupled/RefPlane . . . . . | 370 | | StackupFile/EdaData/Specs/Spec/Impedance/Single_Ended_Coplanar_Waveguide. . . . | | | . . | 371 | | StackupFile/EdaData/Specs/Spec/Impedance/Single_Ended_Coplanar_Waveguide/TraceWidth 373 | StackupFile/EdaData/Specs/Spec/Impedance/Single_Ended_Coplanar_Waveguide/TraceWidth 373 | | StackupFile/EdaData/Specs/Spec/Impedance/Single_Ended_Coplanar_Waveguide/CoplanarSp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | | | acing. | 375 | | StackupFile/EdaData/Specs/Spec/Impedance/Single_Ended_Coplanar_Waveguide/CoplanarTr | | | aceWidth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 376 | | StackupFile/EdaData/Specs/Spec/Impedance/Single_Ended_Coplanar_Waveguide/RefPlane 378 | StackupFile/EdaData/Specs/Spec/Impedance/Single_Ended_Coplanar_Waveguide/RefPlane 378 | | StackupFile/EdaData/Specs/Spec/Impedance/Differential_Broadside_Coupled . . . . . . . . . | 379 | | StackupFile/EdaData/Specs/Spec/Impedance/Differential_Broadside_Coupled/TraceWidth StackupFile/EdaData/Specs/Spec/Impedance/Differential_Broadside_Coupled/TraceSeparation 383 | 381 384 | | StackupFile/EdaData/Specs/Spec/Impedance/Differential_Broadside_Coupled/RefPlane . StackupFile/EdaData/Stackup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 385 | | StackupFile/EdaData/Stackup/Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 387 | | StackupFile/EdaData/Stackup/Group/Layer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 389 | | StackupFile/EdaData/Stackup/Group/Layer/SpecRef. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 391 | | StackupFile/EdaData/Stackup/Group/Layer/SpecRef/Material . . . . . . . . . . . . . . . . . . . . . . | 392 | | StackupFile/EdaData/Stackup/Group/Layer/SpecRef/Impedance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 394 | | StackupFile/SupplierData . . . . . . . . . . . . . . . . . . . . | 395 | | StackupFile/SupplierData/Specs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 397 | | StackupFile/SupplierData/Specs/Spec. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 398 | | StackupFile/SupplierData/Specs/Spec/Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 399 | | StackupFile/SupplierData/Specs/Spec/Material/Dielectric . . . . . . . . . . . . . . . . . . . . . . . . . . | 400 | | StackupFile/SupplierData/Specs/Spec/Material/Dielectric/Properties . . . . . . . . . . . . . . . . . | 402 | | StackupFile/SupplierData/Specs/Spec/Material/Dielectric/Properties/Property . . . . . . . . . . | 403 | | StackupFile/SupplierData/Specs/Spec/Material/Conductor . . . . . . . . . . . . . . . . . . . . . . . . . | 405 | | StackupFile/SupplierData/Specs/Spec/Material/Conductor/Properties. . . . . . . . . . . | 407 | | . . . . . . StackupFile/SupplierData/Specs/Spec/Material/Conductor/Properties/PropertyName . . . . | 408 | | StackupFile/SupplierData/Specs/Spec/Material/Default_Thickness. . . . . . . . . . . . . . . . . . . | 410 |
| StackupFile/SupplierData/Specs/Spec/Impedance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 411 | |---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------| | StackupFile/SupplierData/Specs/Spec/Impedance/Single_Ended. . . . . . . . . . . . . . . . . . . . . | 413 | | StackupFile/SupplierData/Specs/Spec/Impedance/Single_Ended/TraceWidth . . . . . . . . . . . | 415 | | StackupFile/SupplierData/Specs/Spec/Impedance/Single_Ended/RefPlane. . . . . . . . . . . . | 417 | | StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide . . . . | 418 | | StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide/TraceWid | | | th . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 420 | | StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide/Spacing 422 | | | StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide/Coplanar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | | | Spacing. | 423 | | StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide/Coplanar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | | | TraceWidth | 424 | | StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide/RefPlane | | | 426 | | | StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Edge_Coupled. . . . . . . | 427 | | . . . StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Edge_Coupled/TraceWidth | 429 | | StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Edge_Coupled/Spacing. . . | 431 | | StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Edge_Coupled/RefPlane. . | 432 | | StackupFile/SupplierData/Specs/Spec/Impedance/Single_Ended_Coplanar_Waveguide . . | 433 | | StackupFile/SupplierData/Specs/Spec/Impedance/Single_Ended_Coplanar_Waveguide/Trace . | | | Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 435 | | StackupFile/SupplierData/Specs/Spec/Impedance/Single_Ended_Coplanar_Waveguide/Coplan arSpacing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 437 | | StackupFile/SupplierData/Specs/Spec/Impedance/Single_Ended_Coplanar_Waveguide/Coplan . . . . . . | | | arTraceWidth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 438 | | StackupFile/SupplierData/Specs/Spec/Impedance/Single_Ended_Coplanar_Waveguide/RefPla ne . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 440 | | StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Broadside_Coupled. . . . . | 441 | | . StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Broadside_Coupled/TraceWidt | | | h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 443 | | StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Broadside_Coupled/TraceSepar ation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | | | StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Broadside_Coupled/RefPlane | 445 | | 446 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | | | StackupFile/SupplierData/Stackup . . . | 447 | | StackupFile/SupplierData/Stackup/Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 449 | | StackupFile/SupplierData/Stackup/Group/Layer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 451 | | StackupFile/SupplierData/Stackup/Group/Layer/SpecRef . . . . . . . . . . . . . . . . . . . . . . . . . . | 453 | | StackupFile/SupplierData/Stackup/Group/Layer/SpecRef/Material. . . . . . . . . . . . . . . . . . . | 454 | | Stackup Schema File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 455 | | Appendix F | | | Impedance Schema . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 511 | | Impedances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 512 | | Impedances/Descriptor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 513 | | Impedances/Descriptor/RequiredImpedance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 515 | | Impedances/Descriptor/OriginalTraceWidth. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 517 |
Table of Contents
| Impedances/Descriptor/OriginalSpacing. | 518 | |----------------------------------------------------------|-------| | Impedances/Descriptor/RefPlane. . . . . . . | 519 | | Impedance Schema File . . . . . . . . . . . . . . | 519 | | AppendixG | | | XMLSimpleType Elements. . . . . . . . . . . | 523 | | Enumerations . . . . . . . . . . . . . . . . . . . . . . | 523 | | AppendixH | | | Frequently Asked Questions . . . . . . . . . . | 529 |
List of Tables
| Table B-1. ODB++ Product Attributes . . . . . . . | 271 | |------------------------------------------------------|-------| | Table B-2. ODB++ DFM Attributes . . . . . . . . . | 276 | | Table B-3. ODB++ Fabrication Attributes . . . . | 279 | | Table B-4. ODB++ Assembly Attributes . . . . . | 281 | | Table B-5. ODB++ Test Attributes . . . . . . . . . . | 283 | | Table B-6. ODB++ Generic Attributes . . . . . . . | 284 | | Table D-1. Metadata Content - Header Section | 300 | | Table D-2. Metadata Content - Requirements . | 302 | | Table D-3. Metadata Content - Manufacturing . | 306 | | Table D-4. Metadata Content - Assembly . . . . | 310 | | Table D-5. Metadata Content - Final . . . . . . . . | 312 |
Chapter 1 ODB++ Design Format Specification
Competing in global markets requires PCB design organizations to continually seek ways to more effectively communicate their product definition data to fabrication, assembly and test organizations.
The goal is to simultaneously maximize three aspects:
- Speed in transferring a new product design into the manufacturing process
- Accuracy of communication of the designer's intentions to the manufacturer
- Opportunities for reduction in total manufacturing cost
All the data transferred to manufacturers by a designer that defines the PCB for the purposes of bare board fabrication, assembly and test can be referred to as the manufacturing product model. To the manufacturer, this product model defines 'what' should be manufactured and delivered back to the product owner. The manufacturer's task is to validate the manufacturability of the product, then derive and execute the optimal manufacturing process for its manufacture.
The ODB++ Design data exchange format is the most widely accepted, integrated product model format for efficiently handing off a PCB from design into manufacturing. The ODB++ Design format is a simple yet comprehensive description of all entities necessary to answer the question of 'what' needs to be manufactured, covering fabrication, assembly and test of a PCB.
| Changes to the ODB++ Design Format Since V8.0 . . . . . . . . . . . . . . . . . . . . . . . . . . | 14 | |--------------------------------------------------------------------------------------------------------------------------------------|------| | File System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 22 | | Legal Entity Names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 22 | | Units of Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 23 | | ODB++ Attributes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 27 | | Attribute Classes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 27 | | Attribute Value Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 28 | | Unique ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 30 | | Format Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 31 | | Extensible Content. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 31 | | Large File Compression . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 31 | | Structured Text Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 32 | | Line Record Text Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 33 | | Coordinates. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 34 | | Angles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 34 |
| Rotation and Mirroring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 34 | |-----------------------------------------------------------------------------------------------------------------------------------------|------| | Symbols. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 36 | | Standard Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 36 | | User-Defined Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 37 | | Lines and Arcs Drawn with Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 38 | | Surfaces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 38 | | Geometric Entities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 39 | | Self-Intersecting Polygons (SIP). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 40 | | Component Variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 41 |
Changes to the ODB++ Design Format Since V8.0
Changes have been made to the ODB++ Design format in V8.0 and since V8.0.
ODB++ Design 8.1 Update 2
These changes were implemented in this version:
-
The ODB++ format has been renamed to ODB++ Design. The specification title has been adapted according to the new format name. Other occurrences in the specification refer to the format name as ODB++ Design or ODB++.
-
The optional file impedance.xml (impedance file) can be added to the <step_name>
-
directory. This file contains data relevant to the calculation of copper impedance. See '<step_name>/impedance.xml (Impedance)' on page 132.
-
The contents of the attribute definition files sysattr , sysattr.dfm , sysattr.fab , and sysattr.assy have been reorganized to ensure more accurate classification.
-
o See 'Product (sysattr)' on page 271.
-
o See 'DFM (sysattr.dfm)' on page 276.
-
o See 'Fabrication (sysattr.fab)' on page 279.
-
o See 'Assembly (sysattr.assy)' on page 281.
-
Added product attribute (sysattr) .rout_plated.
-
o See 'ODB++ System Attributes - Alphabetical List' on page 215.
-
These impedance attributes were added as product attributes (sysattr): .eda_define_imp_line, .imp_constraint_id, .imp_polyline_id, .impedance_test_width, .padstack_id, .soldermask_define_no_edits.
-
o See 'ODB++ System Attributes - Alphabetical List' on page 215.
-
Product attributes (sysattr) .ipc_via_type_top and .ipc_via_type_bottom were added to support the IPC-4761 Via types.
-
o See 'ODB++ System Attributes - Alphabetical List' on page 215.
-
Product attribute (sysattr) .via_in_pad was added to support Via in Pad (VIP).
-
o See 'ODB++ System Attributes - Alphabetical List' on page 215.
-
The optional file stackup.xml (stackup file) can be added to the <product_model_name>/matrix directory.
The stackup file will replace the matrix file in the next major release of the ODB++ format. In the meantime, the matrix file is required and the stackup file is optional. The format will rely on the matrix file as the primary source of data. If there is an inconsistency, the matrix file will be the primary source of matrix-related ODB++ content.
See 'matrix/stackup.xml (Stackup)' on page 52.
ODB++ 8.1 Update 1
These changes were implemented in this version:
- The manual was fixed to specify the correct formula used to round the line ends for a line thermal symbol.
See 'Basic Standard Symbols' on page 195.
- ODB++ now supports HDI netlists.
See 'eda/hdi_netlist (HDI Netlist)' on page 126.
- ODB++ now supports layers containing wire bond information.
See 'Layer Subtypes' on page 70.
- ODB++ now supports dimensions.
See '<layer_name>/dimensions (Dimensions)' on page 161.
- The manual was fixed to remove an extraneous semicolon from the syntax of the barcode record of the <layer_name>/features entity.
See 'B - Barcode Records' on page 183.
- The manual was fixed to specify the correct limits for measurements such as coordinates and distances. The Cartesian coordinates supported are within the range of (-100, -100) to (100, 100) inches, which is (-2450, -2450) to (2450, 2450) mm.
See 'Units of Measurement' on page 23.
ODB++ 8.1
These changes were implemented in this version:
- Metadata has been added to the ODB++ format.
See 'misc/metadata.xml (Metadata)' on page 79.
- A shorts file has been added to the ODB++ format for defining a list of features that are known to create intentional net shorts within the product model.
See 'eda/shorts (Electrical Intention Short Net)' on page 120.
- A zones file has been added to the ODB++ format for defining regions of the board where the board layer materials, including the layer types, are identical.
See '<step_name>/zones (Matrix Broken Into Sections)' on page 145.
- This manual has been reorganized to more closely reflect the ODB++ directory structure:
- o misc/sysattr.* section moved from the Basic Principles chapter to the misc directory description.
- See 'misc/sysattr.* (Attribute Definition)' on page 86.
- o misc/userattr section added to the misc directory description.
- See 'misc/userattr (User Attribute Definition)' on page 92.
- o A discussion of attribute value assignment was added - using an attrlist file or using lookup tables in a file defining features, components, or nets.
- See 'Attribute Value Assignment' on page 28.
- Additional supported fields are available for the LAYER array of the matrix file.
- See 'Fields in the LAYER Array of a Matrix File' on page 65.
ODB++ 8.0 Update 6
These changes were implemented in this version:
- Section on layer types to support embedded resistors and capacitors added in Product Model Entities.
See 'Layer Subtypes' on page 70.
-
Added test attributes .net_test_type, .net_test_current, .net_test_voltage.
-
o See 'ODB++ System Attributes - Alphabetical List' on page 215.
-
o See 'Test (sysattr.test)' on page 283.
-
Added amps (for current) and volts (for voltage) to the table of units in which data can be stored.
See 'Units of Measurement' on page 23.
- Added options CURRENT and VOLTAGE to possible options for UNIT_TYPE parameter of an attribute of type FLOAT.
- See 'FLOAT Attribute Definition' on page 90.
- Updated the table How the UNITS Directive Determines Units of Measurement, to eliminate ambiguity.
See 'Units of Measurement' on page 23.
ODB++ 8.0 Update 5
These changes were implemented in this version:
- Maximum value for .z0impedance changed from 0.5 to 10000. See 'ODB++ System Attributes - Alphabetical List' on page 215.
- Definition of the side parameter in netlist file format has been further clarified. See 'cadnet/netlist (cadnet)' on page 135.
- A comment was added to the effect that surfaces must have at least one polygon defined. See 'S - Surface Records' on page 185.
- The description of unique IDs was clarified. See 'Unique ID' on page 30.
- Explanation of record type F (number of features) added to the description of the features file.
See '<layer_name>/features (Graphic Features)' on page 170.
ODB++ 8.0 Update 4
These changes were implemented in this version:
- Parameter descriptions for comp_num and toep_num corrected, and clarification added to fill_size for toeprint section.
See 'SNT- Subnet Record' on page 115.
- Clarification of layer profile use when a step profile hole is found within or intersecting a layer profile island.
See '<layer_name>/profile (Outline Shape of Layer)' on page 188.
- Clarification of the relationship between records PKG and CMP. See 'PKG - Package Record' on page 116 and 'CMP - Component Record' on
page 157
- Section on Angles added to Basic Principles section to relate to the angle definition in Step and Repeat records and the orient_def field in Pad records, Text records, and Barcode records.
See 'Angles' on page 34.
- DSC parameter in BOM Description Records corrected from 'up to 5' to 'unlimited'. See 'BOM Description Records' on page 158.
- Clarification of what constitutes a legal net name.
See the description of $<serial_num> <net_name> in 'cadnet/netlist (cadnet)' on page 135 and <net_name> in 'NET - Electrical Net Record' on page 114.
ODB++ 8.0 Update 3
These changes were implemented in this version:
- UNIT_TYPE of RESISTIVITY requires a UNITS value.
- Two new UNITS values available when UNIT_TYPE=RESISTIVITY-OHM and NANO_OHM.
- See 'FLOAT Attribute Definition' on page 90.
- UNITS value NANO_OHM added to system attribute .bulk_resistivity.
- COPPER_WEIGHT added to the list of available UNIT_TYPE values. See 'FLOAT Attribute Definition' on page 90.
- In the cadnet/netlist (cadnet) step entity, the definition of the radius field was expanded. See 'cadnet/netlist (cadnet)' on page 135.
- Two product attributes (sysattr) .centroid_correction_x and .centroid_correction_y added.
See 'ODB++ System Attributes - Alphabetical List' on page 215.
- These attributes have been updated to include the required UNITS tag, in the relevant sysattr file:
| sysattr | sysattr.assy | sysattr.dfm | sysattr.fab | |--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------| | .board_thickness .bulk_resistivity .comp_height .comp_height_max .comp_htol_minus .comp_htol_plus .layer_dielectric .pitch .testprobe_diameter .thickness_over_cu .thickness_over_sm | .spo_h_val .spo_move_center .spo_p_val .spo_s_val .spo_w_val | .ar_pad_drill_bottom_max .ar_pad_drill_bottom_min .ar_pad_drill_inner_max .ar_pad_drill_inner_min .ar_pad_drill_top_max .ar_pad_drill_top_min .ar_sm_drill_bottom_max .ar_sm_drill_bottom_min .ar_sm_drill_top_max .ar_sm_drill_top_min .ar_sm_pad_bottom_max .ar_sm_pad_bottom_min .ar_sm_pad_top_max .ar_sm_pad_top_min .dpair_gap .drc_max_height .drc_min_height .eclass_max_stub_length .eclass_min_stub_length .local_fiducial_dist .min_line_width .net_length_max .net_length_min .toep_spacing_req | .et_adjacency .fill_dx .fill_dy .image_dx .image_dy |
For a description of each attribute, see 'ODB++ System Attributes - Alphabetical List' on page 215.
ODB++ 8.0 Update 2
These changes were implemented in this version:
-
Improved the netlist example to include the use of 'ld'.
-
See 'cadnet/netlist (cadnet)' on page 135.
-
Corrected the syntax for the optimization (H) record.
-
See 'cadnet/netlist (cadnet)' on page 135.
-
Tools (Drill Tools):
-
o Corrected to indicate units of measurement for MIN_TOL, MAX_TOL, FINISH_SIZE and DRILL_SIZE.
-
o Added in the description of FINISH_SIZE that if this value is not set, the value should be -1.
See '<layer_name>/tools (Drill Tools)' on page 191.
- Clarified that the decimal character is required to be a period, and no other representation of numbers (scientific or exponential) is allowed.
See 'Coordinates' on page 34.
- Clarified that the decimal character is required to be a period.
See 'Symbols' on page 36.
- The compression attribute was added to bom , and the example was modified.
See '<bom_name>/bom (Bill Of Materials)' on page 101.
- More detailed descriptions were added to the START_NAME and END_NAME fields in the LAYER array of the matrix file.
See 'Fields in the LAYER Array of a Matrix File' on page 65.
ODB++ 8.0 Update 1
These changes were implemented in this version:
- Default color for layer display in the layer list is 0, indicating no preference.
- See the COLOR field in 'Fields in the LAYER Array of a Matrix File' on page 65.
- Netlist definition enhanced to include staggered.
- See the example for 'cadnet/netlist (cadnet)' on page 135.
- Corrected format syntax.
See 'NET - Electrical Net Record' on page 114.
- SNT VIA and SNT TRC records were clarified to not contain any additional parameters.
See 'SNT- Subnet Record' on page 115.
- PKG-Package Record - Corrected format syntax.
See 'PKG - Package Record' on page 116.
- PIN-Pin Record - Clarified the determination of pin #1.
See 'PIN - Pin Record' on page 117.
ODB++ 8.0
These changes were implemented in this version:
- Attributes are divided according to area: DFM, Product, or Process. The Process attributes are further classified as Fab, Assem, Test, or Generic.
See 'ODB++ Attributes' on page 27.
- Includes Flex and Flex-rigid PCB modeling.
See 'Layer Subtypes' on page 70.
- Symbols added for Solder Stencil Design:
- o Home Plate
- o Inverted Home Plate
- o Flat Home Plate
- o Radiused Inverted Home Plate
- o Radiused Home Plate
- o Cross
- o Dogbone
- o D-Pack
See 'Symbols Suitable for Solder Stencil Design' on page 210.
- Default metric/imperial measurement used throughout product model definition. The units directive UNITS=MM|INCH can be added at the beginning of any file that contains measurable entities.
See 'Units of Measurement' on page 23.
-
Drill span direction.
-
Creation of profile with holes enabled.
-
Net name length enlarged. There is no limit on the number of characters in a net name.
-
Support for test probes. Test Probe Diameter attribute introduced to provide information on the size of test probes.
-
PCB build up information stored in product model.
-
Support for increased number of BOM Desc attributes. Number of descriptions in BOM (DESC<index> or PART_DESC<index>) is unlimited.
-
Introduction of package attributes.
-
It is now possible to implement component Bill of Material (BOM) information within the component file.
File System
The ODB++ format uses a standard file system structure. A product model stored in the ODB++ format is represented by an independent and self-contained directory tree. This provides the ability to transfer the product model from design systems into manufacturing systems in an efficient manner, without any loss of information.
The advantages of a directory tree, compared to one large file, are apparent when a product model is being read from disk or saved to disk. The flexible tree structure allows you to read or save exactly the required part of the product model, avoiding the overhead of reading and writing a large file, if only a subset of the information is required.
When a product model tree must be transferred to another system, standard tar and compression utilities can be used to convert a directory tree into a single flat file.
These files and directories are mandatory. Other files and directories discussed in this document are included only when needed.
- <product_model_name>/matrix/matrix
- <product_model_name>/misc/info
- <product_model_name>/fonts/standard
- <product_model_name>/steps/<step_name>/stephdr
- <product_model_name>/steps/<step_name>/layers/<layer_name>/features (or features.Z )
There are links between files, defined implicitly in the ODB++ definition, that create dependencies between files.
For example, the file /<step_name>/layers/comp_+_top/components contains links to / <step_name>/eda/data , and the /<step_name>/layers/<layer_name>/features file contains links to user-defined symbols located in <product_model_name>/symbols .
Legal Entity Names
The names of these ODB++ entities must comply with the rules for legal entity names: product model, step, layer, symbol, and attribute.
-
The length of an entity name must not exceed 64 characters.
-
An entity name may contain only these characters:
-
o Lower case letters (a through z).
-
o Digits (0 through 9).
-
o Punctuation-dash (-), underscore (_), dot (.) and plus (+).
-
Entity names must not start with a dot ( . ), hyphen (-), or plus (+).
The exception is system attribute names, which start with a dot. Names of user-defined attributes must not start with a dot.
- Entity names must not end with a dot (.).
Units of Measurement
ODB++ files can contain an indication of the units of measurement used in the file.
Unlike traditional CAM formats such as Gerber, ODB++ format represents a complete product model rather than a collection of unrelated geometric entities. All ODB++ format compatible applications must be able to represent the ODB++ product model correctly. For example, if two individual features do not touch, this relationship must be maintained by the ODB++ compatible application.
Minimum resolution for maintaining feature representation is 1/400 micron (1/10160 mil). Minimum line or arc width is 1/400 micron. Minimum measurable distance, or placement tolerance, for any feature is 1/400 micron.
Measurements such as coordinates and distances must be within the supported range. The Cartesian coordinates supported are within the range of (-100, -100) to (100, 100) inches, which is (-2450, -2450) to (2450, 2450) mm.
Files that contain measurable entities must include the UNITS directive, to specify whether measurements in the file are given in metric units (UNITS=MM) or in imperial units (UNITS=INCH). The UNITS directive is placed before the first line that uses units. Only one UNITS directive can appear in a file.
The default units of measurement for the product model are as defined in the UNITS directive in the file misc/info of the product model. If the default is not defined for the product model, the default is imperial.
For newly created files, units are based on the default defined for the product model.
For each file described in this document, there is a table of information. The UNITS row of the file information table indicates whether the UNITS directive is required for that file:
| <file_name> | <file_name> | |---------------|--------------------------------------------------------------------------------------------------------------------------| | Type | One of these strings: • Line Record Text • Structured Text | | Compression | One of these strings: • None • Yes | | Path | Path to the file. | | UNITS | One of these strings: • The UNITS directive is required. • The UNITS directive is not relevant for the <file_name> file. |
Files that Must Contain the UNITS Directive
| File Name | Path | |--------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | info | <product_model_name>/misc | | sysattr sysattr.dfm sysattr.fab sysattr.assy sysattr.test sysattr.gen userattr | <product_model_name>/misc | | attrlist | <product_model_name>/misc <product_model_name>/steps/<step_name> <product_model_name>/steps/<step_name>/layers/<layer_name> <product_model_name>/symbols/<symbol_name> <product_model_name>/wheels/<wheel_name> | | stephdr | <product_model_name>/steps/<step_name> | | profile | <product_model_name>/steps/<step_name> <product_model_name>/steps/<step_name>/layers/<layer_name> | | data | <product_model_name>/steps/<step_name>/eda |
| File Name | Path | |-------------|-------------------------------------------------------------------------------------------------------------------| | features | <product_model_name>/steps/<step_name>/layers/<layer_name> <product_model_name>/symbols/<symbol_name> | | tools | <product_model_name>/steps/<step_name>/layers/<layer_name> | | components | <product_model_name>/steps/<step_name>/layers/comp_+top <product_model_name>/steps/<step_name>/layers/comp+_bot | | netlist | <product_model_name>/steps/<step_name>/netlists/cadnet <product_model_name>/steps/<step_name>/netlists/refnet |
How Measurements Are Stored
According to the unit of measurement selected, data is stored in these units:
| Type of Data | Metric (UNITS=MM) | Imperial (UNITS=INCH) | |-------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| | area | squaremm | square inch | | copper weight | µm In metric units, copper weight is actually copper thickness. The application converts it accordingly into commonly used neutral units (thickness or weight). | ounce per square foot | | current | amps | amps | | distances, sizes, coordinates | mm | inch | | resistance | ohm | ohm | | temperature | centigrade | fahrenheit | | voltage | volts | volts | | weight | gram | ounce |
How the UNITS Directive Specifies Units of Measurement
| Location of UNITS Directive | Scope | Example | |-------------------------------------------------------------|---------------------------------------------------------------------------|-----------| | There is no UNITS directive in <product_model>/ misc/info . | The default units of measurement for the product model is imperial units. | None |
| Location of UNITS Directive | Scope | Example | |--------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | There is a UNITS directive in <product_model>/ misc/info . | The units of measurement specified in this UNITS directive is the default for the product model. | info file example: JOB_NAME=odbv_demo_mm ODB_VERSION_MAJOR=8 ODB_VERSION_MINOR=1 ODB_SOURCE= CREATION_DATE=20170913.130051 SAVE_DATE=20170914.132825 SAVE_APP=Valor NPI 10.1 SAVE_USER=roni UNITS=MM MAX_UID=431990 | | If there is a UNITS directive in a file that supports it, and there are no other specifications of units of measurement in the file. | The units of measurement specified in the UNITS directive is used for all measurements in the file. | stephdr file example: UNITS=INCH X_DATUM=0 Y_DATUM=0 X_ORIGIN=0 Y_ORIGIN=0 TOP_ACTIVE=0 BOTTOM_ACTIVE=0 RIGHT_ACTIVE=0 LEFT_ACTIVE=0 AFFECTING_BOM= AFFECTING_BOM_CHANGED=0 ID=0 | | There is a UNITS directive in a file that supports it, and individual records in the file also specify units of measurement. | The units of measurement specified in the UNITS directive is used except where this is overridden by the specification in an individual record in the file. | features file example: The "I" at the end of the symbol definition line specifies imperial units. This overrides the specification of UNITS=MM. UNITS=MM ID=616 # #Num Features # F 12397 # #Feature symbol names $0 oval210x170 I |
ODB++ Attributes
Attributes in the ODB++ format provide a flexible way to assign product related and process related information to ODB++ entities. The use of attributes by the ODB++ format has been standardized and is supported in a unified manner, independent of any application-specific references to attributes. All system attributes are optional.
Attribute definition files for all attributes in the product model are stored under <product_model_name>/misc . They all have the same syntax.
Attributes starting with the dot (.) character are system attributes. See 'misc/sysattr.* (Attribute Definition)' on page 86.
User-defined attributes cannot have the dot character before their name. See 'misc/userattr (User Attribute Definition)' on page 92.
| Attribute Classes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 27 | |---------------------------------------------------------------------------------------------------------------------------------------|------| | Attribute Value Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 28 |
Attribute Classes
At the highest level, attributes within the ODB++ format are divided into these classes: DFM Analysis, Product, and Process.
<!-- image -->-
DFM Analysis attributes - Used to enable or enhance analysis. An example is .center_fiducial for components that require a center fiducial.
-
Product attributes - Used to describe the finished product. An example is .gold_plated on a copper features to indicate that gold will be delivered at these locations.
-
Process attributes - Used to add further definition to the manufacturing process applied to the product. Process attributes are divided into process categories:
-
o Fabrication - For example, the fabrication process attribute .plating_bar describes the manufacturing purpose for a piece of copper that is later removed by the milling/ routing process and is not delivered to the customer as part of the final product.
-
o Assembly - For example, the assembly process attribute .fs_direction_top is used to describe the flow solder assembly direction.
-
o Test - These attributes are for the functional, optical, and other testing of the PCBA product before, during or following the assembly process. An example would be the HP3070 attributes used to deliver programs for this test machine.
-
o Generic - The generic attributes related to the production process.
The attribute definitions for each attribute class are stored in a separate file.
In addition to the files that contain system attribute definitions, the file userattr can be used to define user attributes for all entities. It is stored in the library when the product model is created. It is read each time the product model is opened.
These files contain attribute definitions:
| AttributeDefinition File | Class | List of System Attributes in the Class | |----------------------------|--------------|------------------------------------------| | sysattr | Product | 'Product (sysattr)' on page 271 | | sysattr.dfm | DFM analysis | 'DFM (sysattr.dfm)' on page 276 | | sysattr.fab | Fabrication | 'Fabrication (sysattr.fab)' on page 279 | | sysattr.assy | Assembly | 'Assembly (sysattr.assy)' on page 281 | | sysattr.test | Test | 'Test (sysattr.test)' on page 283 | | sysattr.gen | Generic | 'Generic (sysattr.gen)' on page 284 | | userattr | (none) | (Contains user-defined attributes.) |
Attribute Value Assignment
You can assign system attributes and user-defined attributes to ODB++ entities. For some entities, attributes are assigned using an attrlist file. For some entities, attributes are assigned using a lookup table.
Attrlist Files
For some entities, an attrlist file is placed under the entity, containing a list of attribute names and values. For example, this attrlist file assigns attributes to the layer named <layer_name> : <product_model_name>/steps/<step_name>/layers/<layer_name>/attrlist:
UNITS=MM .out_mirror = no .inp_file = .eda_layers = "signal_2","signal","VIA" .out_angle = 0.0 .out_polarity = positive .out_x_scale = 1.000000 .out_y_scale = 1.000000 .out_comp = 0.000000
Lookup Tables
For entities for which multiple entities are defined in the same file-such as features, components, or nets-each entity definition line can contain attribute assignments for the entity being defined. Lookup tables are used to allow the entity assignment syntax to use shortcuts to refer to attributes and their values. This is an example of a feature attribute lookup table, and a feature definition record that assigns attributes by pointing to attributes and their values in the string 3=2,4=0:
# #Feature attribute names # @0 .smd @1 .nomenclature @2 .test_point @3 .geometry @4 .pad_usage # #Feature attribute text strings # &0 9796334 &1 fid_0_0_0 &2 moire # #Layer features # P -0.198 1.62 16 P 0 3;3=2,4=0;ID=123456
ODB++ Entities That Can Have Attributes Assigned Using Lookup Tables
| ODB++ Entity | File with Attribute Lookup Tables | Explanation | |----------------|----------------------------------------------------|-------------------------------------------------------| | Symbol Feature | /symbols/<symbol_name>/features | '<symbol_name>/features (Symbol Features)' on page 95 | | Net | /steps/<step_name>/eda/data | 'eda/data (EDA Data)' on page 109 | | Feature | /steps/<step_name>/layers/ <layer_name>/features | '<layer_name>/features(Graphic Features)' on page 170 | | Component | /steps/<step_name>/layers/ <layer_name>/components | '<layer_name>/components (Components)' on page 153 |
ODB++ Entities That Can Have Attributes Assigned in an attrlist File
| ODB++ Entity | attrlist File | Explanation | |----------------|-------------------------------------|-----------------------------------------------------------| | Product Model | <product_model_name>/misc/ attrlist | 'misc/attrlist (Product Model Attribute List)' on page 76 |
| ODB++ Entity | attrlist File | Explanation | |----------------|--------------------------------------------------|-------------------------------------------------------------| | Symbol | /symbols/<symbol_name>/attrlist | '<symbol_name>/attrlist (Symbol Attribute List)' on page 94 | | Wheel | /wheels/<wheel_name>/attrlist | '<wheel_name>/attrlist (Wheel Attribute List)' on page 96 | | Step | /steps/<step_name>/attrlist | '<step_name>/attrlist (Step Attribute List)' on page 100 | | Layer | /steps/<step_name>/layers/ <layer_name>/attrlist | '<layer_name>/attrlist (Layer Attribute List)' on page 152 |
Unique ID
The ODB++ format supports the permanent reference of entities through the use of indices for unique IDs. The unique ID is optional, but once assigned, is never changed, and no other entity within the product model can bear the same ID.
IDs are represented by a positive number between 0 and 4294967295.
Unique IDs are generated for use in the product model definition of these files: matrix , stephdr , features , components , and profile . The largest unique ID used in the product model is stored in the info file. See 'misc/info (Basic Product Model Information)' on page 77.
The stephdr , features , components , and profile files can also have their own individual ID record to uniquely identify the file itself.
A feature file with an ID of 216 would look like this:
UNITS=INCH ID=216 ….. # #Feature symbol names # $0 r4 $1 r5
A component file with an ID of 843 would look like this:
UNITS=INCH ID=843 # #Component attribute names # @0 .comp_height @1 .package_type "
Format Definition
All files in the ODB++ format are ASCII files.
In all files, the hash (#) character specifies a comment. Lines that start with this character should be ignored, and are only used for readability.
The line separator can be either <LF> or <CR><LF>, depending on operating system and platform.
Extensible Content
Third parties are free to place additional content in the ODB++ file structure. Third parties are not constrained to using ASCII format, and are free to use encrypted or non-encrypted formats such as binary, ASCII, XML, and others. But that content is outside the format specification described for ODB++.
Large File Compression
One of the reasons vendors have chosen binary data in the past was the need to conserve disk space. Modern compression techniques provide excellent compression ratios, especially for ASCII files with repetitive patterns. Large files in ODB++ format are saved in standard UNIX compression format. The compression is optional. Software reading the ODB++ product model structure should expect some files to be compressed ( .Z ) and some not.
For each file described in this document, there is a table of information. Files that are potentially compressed are identified, in this document, in the Compression row of the file information table in the description of the file:
| <file_name> | <file_name> | |---------------|--------------------------------------------------------------------------------------------------------------------------| | Type | One of these strings: • Line Record Text • Structured Text | | Compression | One of these strings: • None • Yes | | Path | Path to the file. | | UNITS | One of these strings: • The UNITS directive is required. • The UNITS directive is not relevant for the <file_name> file. |
Structured Text Files
Many text files in ODB++ format contain structured text. The main advantages of this file type is readability. The user can open a file and understand its contents without needing to refer to external sources.
Structured text files contain expressions in this format:
<variable>=<value>
A more elaborate structure, which appears in some structured text files, describes arrays. Arrays are lists of elements, each one containing several fields. The expression <variable>=<value> appears multiple times, each time defining an element of the array:
<array_name> { <variable>=<value> <variable>=<value> .... }
For each file described in this document, there is a table of information. Structured text files are identified as such in the Type row of the file information table:
| <file_name> | <file_name> | |---------------|--------------------------------------------------------------------------------------------------------------------------| | Type | One of these strings: • Line Record Text • Structured Text | | Compression | One of these strings: • None • Yes | | Path | Path to the file. | | UNITS | One of these strings: • The UNITS directive is required. • The UNITS directive is not relevant for the <file_name> file. |
Example of a <variable>=<value> Expression
X_DATUM=0.3
Example of an Array
LAYER { ROW=1 CONTEXT=BOARD TYPE=COMPONENT NAME=COMP_+_TOP POLARITY=POSITIVE START_NAME= END_NAME= OLD_NAME= ADD_TYPE=MICRO_VIA COLOR=606090 }
Line Record Text Files
In some ODB++ files, each line contains multiple fields, typically separated by space characters. Typically, the first character or string in each line defines the type of record that the line describes. In many cases, the line order is significant.
The ODB++ format permits line length of up to 1,400 characters. A line longer than this can be truncated.
For each file described in this document, there is a table of information. Line record text files are identified as such in the Type row of the file information table:
| <file_name> | <file_name> | |---------------|--------------------------------------------------------------------------------------------------------------------------| | Type | One of these strings: • Line Record Text • Structured Text | | Compression | One of these strings: • None • Yes | | Path | Path to the file. | | UNITS | One of these strings: • The UNITS directive is required. • The UNITS directive is not relevant for the <file_name> file. |
Example of a Line Record Text File
# #Feature symbol names # $0 r50 $1 r70 $2 r80 $3 r93 $4 ths80x60x0x4x15 # #Feature attribute names # @0 .geometry @1 .pad_usage # #Feature attribute text strings # &0 systest_board &1 term_1 &2 via_1 # #Layer features # L -0.4 -3.6 -0.4 -4 0 P 0;0=0 L -0.4 -4 0 -4 0 P 0;0=0 L -0.4 -1.4 -0.4 -1 0 P 0;0=0 L -0.4 -1 0 -1 0 P 0;0=0
Coordinates
From ODB++ format v8.0, the UNITS directive must be present in every file that contains coordinates or measurements.
In ODB++ format v7.x, the units directive described the units applied in the feature file; and when not present, imperial units were assumed. Therefore, coordinates were expressed in inches; symbol sizes were expressed in mils.
When specifying a fractional coordinate, the separator for decimal numbers must be a period (.) For example, s3.25 2.456. No other representation of numbers is allowed (such as scientific notation, exponential, or others).
Angles
All angles are defined by a positive value between 0 and 360 degrees.
Rotation and Mirroring
These are the rules for rotation and mirroring.
- Feature pads can be rotated. Rotation is expressed in degrees or in multiples of 90 degrees, and is always clockwise.
- Mirroring occurs only along the x-axis (left to right, changing x coordinates).
- If both rotation and mirroring are performed, the feature is first rotated, and then mirrored.
Symbols
Symbols define a wide variety of shapes that are mostly used to represent pads.
| Standard Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 36 | |------------------------------------------------------------------------------------------------------------------------------------|------| | User-Defined Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 37 | | Lines and Arcs Drawn with Symbols. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 38 |
Standard Symbols
Standard symbols are rendered dynamically from their names. They do not require that a graphic symbol entity be saved. They are round, square, or parametric shapes.
The names of standard symbols have this structure:
- <symbol_name_prefix>[<parameter_value>[x<parameter_value>[...]]]
where parameter_value is a decimal number, integer or real. Parameter values are delimited with an x character.
For example, a rounded square thermal is specified using a name like this:
s_ths200x180x15x5x10xr20
- s_ths - Symbol name prefix.
- 200, 180, 15, 5, 10, r20 - Parameter values presented in the required order.
Note
- When specifying a fractional symbol size, the separator for decimal numbers must be a period (.). For example, s3.25.
Symmetric symbols (round symbols, or square symbols where width = height) are required to create lines and arcs. The width of a line or arc is the width of the symmetric symbol used to draw it. See 'Lines and Arcs Drawn with Symbols' on page 38.
Roundcapped line is drawn by a round symnbol
<!-- image -->Square capped line is drawn by a square symbol
<!-- image -->Units for parameters that represent size are expressed as a thousandth part of an inch or as a micron, depending on the current UNITS directive. See 'Units of Measurement' on page 23 for a discussion of the UNITS directive.
ODB++ format guarantees precision for standard symbol dimensions in non-integers with resolutions of up to 1/100 mils.
Symbol r0 is a legal entity. Its area is 0, and it is recommended to display it with a single display pixel.
Standard symbols are all positive filled shapes. Holes in symbols are see-through by definition. The internal implementation of complex symbols uses arc or contour data with cutouts.
User-Defined Symbols
User-defined symbols have a full graphic description stored in features files in the product model symbols directory. A user-defined symbol can contain any number of features, including any number of other user-defined symbols. Circular references are prohibited. User-defined symbols are typically created for shapes that are not found among the standard symbols.
A user-defined symbol is an ODB++ entity that is defined once and can be used multiple times, to avoid repeating the definition of a group of features on a layer. A symbol definition contains a features file that specifies the primitive features (such as pad, line, arc, surface, and text) that comprise the symbol on the layer. See '<symbol_name>/features (Symbol Features)' on page 95.
It is preferable to use a standard symbol, where possible. User-defined symbols require more memory than standard symbols, and having a large number of them will slow down processing.
A symbol can be referenced from multiple layers in the product model, at different coordinates. Changing the symbol definition will automatically cause all its representations in the layers to change accordingly.
<!-- image -->Standard symbol name prefixes are reserved for use in standard symbol names and cannot be assigned to user-defined symbols. Standard symbol name prefixes cannot be used for userdefined symbols even if the name of the user-defined symbol has a different format from that of the standard symbol, or if the user-defined symbol allows parameter values that are illegal in the
standard symbol with that prefix. For a list of these reserved names, see 'Basic Standard Symbols' on page 195.
Like standard symbols, user-defined symbols are scalable.
See '<layer_name>/features (Graphic Features)' on page 170 for an example of the UNITS directive in the features file.
This user-defined symbol represents an arrow whose origin (0,0) is at the head of the arrow on the left. It is drawn from lines (standard symbols). When inserting this symbol, the insertion point is at (0, 0).
<!-- image -->Lines and Arcs Drawn with Symbols
Lines and arcs are created by a symbol and two points-a start point and an end point. Lines and arcs are drawn by dragging the symbol by its center along a line or circular curve from one end to the other.
For arcs, only round symbols can be used.
If the symbol used to draw a line is symmetrical (square or round) the width of the generated line is the side or the diameter of the symbol.
A round symbol (whose name starts with r) generates round line ends .
<!-- image -->A square symbol (whose name starts with s) generates square line ends .
<!-- image -->Using non-symmetric symbols (standard or user-defined) for the drawing of lines is not recommended, because their implementation tends to be inefficient. If such lines are found in a product model, the application must decide how to handle them. The result should resemble the sweep of the symbol from its start point to its end point.
Surfaces
A surface is a feature that represents a legal contour.
A surface has these properties:
- The islands of a contour do not overlap.
- Holes inside islands do not intersect.
- Islands and holes are ordered in a specific way.
The order of containment of holes and islands within surfaces determines their natural order. The outermost island comes first. Islands precede holes that are contained in them. Holes precede islands that are contained in them.
In this example, the natural containment order would be A, B, C, D, E. Island D is separate from island A.
<!-- image -->Polygons must meet these restrictions:
- Self-intersecting polygons (SIPs) are not allowed.
- Polygons, both the island and holes, must be sequenced to form a closed shape. That means that all polygons must contain at least three segments, and the last record point must be the same as the first.
- Edge lengths should be greater than zero.
- Holes must be graphically contained inside island polygons.
- The direction of segments representing the edges of an island must be clockwise, and the direction of segments representing the edges of holes must be counter-clockwise.
- The curves must be consistent-the start, end, and center point must construct a legal curve.
Geometric Entities
The ODB++ format uses geometric primitives called features to describe product model geometry. Features are stored in the feature containers of layers, profiles, and symbols. The types of geometric entities supported by the ODB++ format are the pad, line, arc, surface, and text.
These primitives are defined by the concept of a symbol and a contour.
- Symbol - A symbol is either one of the geometric primitives supported by the ODB++ format described in 'Basic Standard Symbols' on page 195, or a combination of them.
- Contour - A contour is represented by single or multiple islands. An island is the area inside a boundary that consists of straight and circular segments. Islands in a contour do not touch or intersect with one another. Each island can contain holes that are also defined by a boundary. Those boundaries are referred to as polygons. The boundary of an island is oriented clockwise; the boundary of a hole is oriented counter-clockwise.
Features can be positive or negative. Positive features cover all underlying parts of features previously added to the feature container. Negative features erase all underlying parts of features previously added to the feature container.
These geometric entities are supported by the ODB++ format:
- Arc - Created by dragging a symbol along a circular segment. Arcs are defined by their start point, end point, center, direction (clockwise or counter-clockwise), and symbol.
When the start-point and end-point of an arc coincide, it is considered a 360 degree arc. There are no single-point arcs in the ODB++ format.
- Surface - A solid polygon that can contain non-intersecting islands, that themselves can contain any number of holes.
- Text - Consists of letters drawn with a font or barcode. Text is defined by a text string, font, and text size. See 'fonts/standard (Standard Font)' on page 48 and 'B - Barcode Records' on page 183.
- Pad - The most primitive geometric entity. A pad is a point made with a symbol. Pads are defined by their location and their symbol.
- Line - Created by dragging a symbol along a straight segment. Lines are defined by their start point, end point, and symbol.
Self-Intersecting Polygons (SIP)
In all polygon representations, a self-intersecting polygon (SIP) is illegal. A SIP is a polygon with a boundary that intersects itself at one or more points.
Polygons can represent, for example, graphic surfaces or component package bodies.
<!-- image -->Legal polygons are those whose edges intersect only at endpoints of consecutive edges.
SIPs impede the correct representation of required product model elements and hinder their mathematical representation. These are some examples of problematic operations:
- Correct rendering of layer graphics.
- Resizing (enlarging, shrinking, changing shape).
- Calculation of copper areas, where unambiguous definition of the copper location is essential.
Component Variants
The definition of component variants within ODB++ is based on the active BOM applied to a step of the product model. The existence of multiple variants indicates which components should be used, based on the currently applied BOM.
The active BOM is specified in the AFFECTING_BOM field of the stephdr file.
The ODB++ format displays a variant by applying the attribute Not Populated per BOM (.no_pop) for components that are not to be used.
See '<step_name>/boms (Bill of Materials)' on page 101.
These attributes control the use of component variants:
| Attribute Name | Internal name | Explanation | |----------------------------|------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Product Model Variant List | .variant_list | This product model attribute contains a list of all variants available within the product model, using a colon (:) as a separator. For example, this value would represent three variants, build_1, build_2 and build_3: .variant_list=build_1:build_2:build_3 | | Active Variant | .current_variant | This step attribute can contain one of the variant names listed in attribute Product Model Variant List, if one has been selected. If no variant is currently applied, then its value is empty. |
| Attribute Name | Internal name | Explanation | |------------------|--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Variant List | .comp_variant_list | When attribute Active Variant is applied, this component attribute should already be applied to each component. This attribute contains the list of variants of which the component is a member. The list contains the names of all relevant variants, separated by colons (:). When the attribute Active Variant contains a variant name, components that are not members of that variant should bear the attribute Not Populated per BOM(.no_pop). |
Chapter 2 Product Model Tree
An ODB++ product model is a directory containing sub-directories that represent ODB++ entities. These charts illustrate the directory hierarchy.
Users can create additional files in the user directory related to each entity as long as they do not conflict with ODB++ standard directories. Directories that are no longer supported might appear in ODB++ models containing legacy data.
| <product_model_name> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 43 | |----------------------------------------------------------------------------------------------------------------------------|------| | <product_model_name>/steps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 44 | | <product_model_name>/steps/<step_name>/layers. . . . . . . . . . . . . . . . . . . . . . . . . . . . | 46 |
<product_model_name>
This is the top level product model directory tree.
<!-- image -->These sub directories of the <product_model_name> directory are described:
| Sub Directory | File | Link to Explanation | |-----------------|-------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | steps | | '<product_model_name>/steps' on page 44. | | symbols | attrlist features | '<symbol_name>/attrlist (Symbol Attribute List)' on page 94 '<symbol_name>/features (Symbol Features)' on page 95 | | matrix | matrix | 'matrix/matrix (Matrix)' on page 62 | | misc | attrlist last_save info metadata.xml sysattr files userattr | 'misc/attrlist (Product Model Attribute List)' on page 76 'misc/last_save (Last Time Product Model Saved)' on page 77 'misc/info (Basic Product Model Information)' on page 77 'misc/metadata.xml (Metadata)' on page 79 'misc/sysattr.* (Attribute Definition)' on page 86 'misc/userattr (User Attribute Definition)' on page 92 | | wheels | attrlist dcodes | '<wheel_name>/attrlist (Wheel Attribute List)' on page 96 '<wheel_name>/dcodes (Dcodes)' on page 96 | | fonts | standard | 'fonts/standard (Standard Font)' on page 48 |
<product_model_name>/steps
A product model contains one or more step entities.
Each step entity can containsome or all of these entities.
- Layers included in the step.
- Step and repeat information - The stephdr file specifies any steps that are included in this one and their relative location and orientation.
- Netlist description of the step - CAD netlist and reference netlist.
- An EDA object - This contains information about the component packages and pins. It also contains information about the relation of features in the board layers to specific design nets and properties imported from the EDA system. It can contain a definitions of intentional shorts.
- A profile - A border around the step representing the board edge.
- Zone definitions - A cross sectional view of areas of the step profile.
This chart represents the directory tree under each step:
<!-- image -->These files and sub directories of the <step_name> directory are described:
| Sub Directory | File | Link to Explanation | |-----------------|---------------|------------------------------------------------------------------------------------------------| | | stephdr | '<step_name>/stephdr (Step Header)' on page 143 | | | attrlist | '<step_name>/attrlist (Step Attribute List)' on page 100 | | layers | | See 'Layer Entities' on page 151. | | netlists | cadnet refnet | 'cadnet/netlist (cadnet)' on page 135 'refnet/netlist (Reference)' on page 141 | | | profile | '<step_name>/profile (Outline Shape of Step)' on page 141 | | boms | bom files | '<bom_name>/bom (Bill Of Materials)' on page 101 '<bom_name>/files (Source Files)' on page 106 | | eda | data shorts | 'eda/data (EDA Data)' on page 109 'eda/shorts (Electrical Intention Short Net)' on page 120 | | zones | | '<step_name>/zones (Matrix Broken Into Sections)' on page 145 |
<product_model_name>/steps/<step_name>/ layers
This chart represents the directory tree under each layer.
<!-- image -->These files of the <layer_name> directory are described:
| File | Link to Explanation | |------------|-------------------------------------------------------------| | attrlist | '<layer_name>/attrlist (Layer Attribute List)' on page 152 | | profile | '<layer_name>/profile (Outline Shape of Layer)' on page 188 | | features | '<layer_name>/features (Graphic Features)' on page 170 | | components | '<layer_name>/components (Components)' on page 153 | | tools | '<layer_name>/tools (Drill Tools)' on page 191 | | notes | '<layer_name>/notes (Electronic Notes)' on page 188 |
Chapter 3 Product Model Entities
Several ODB++ entities are defined at the product model level.
For a list of mandatory files and directories, see 'File System' on page 22.
| ext (Extension) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 47 | |------------------------------------------------------------------------------------------------------------------------------------------|------| | fonts (Fonts Used in Product Model) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 48 | | fonts/standard (Standard Font) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 48 | | input (Input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 50 | | matrix (Product Model Matrix) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 51 | | matrix/stackup.xml (Stackup). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 52 | | matrix/matrix (Matrix) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 62 | | misc (Miscellaneous) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 76 | | misc/attrlist (Product Model Attribute List) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 76 | | misc/last_save (Last Time Product Model Saved) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 77 | | misc/info (Basic Product Model Information) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 77 | | misc/metadata.xml (Metadata) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 79 | | misc/sysattr.* (Attribute Definition). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 86 | | misc/userattr (User Attribute Definition) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 92 | | steps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 93 | | symbols (User-Defined Symbols) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 94 | | <symbol_name>/attrlist (Symbol Attribute List) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 94 | | <symbol_name>/features (Symbol Features) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 95 | | user (User) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 95 | | wheels (Gerber and Tool Wheels) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 96 | | <wheel_name>/attrlist (Wheel Attribute List) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 96 | | <wheel_name>/dcodes (Dcodes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 96 |
ext (Extension)
This directory is the location to store third party data files.
See 'Extensible Content' on page 31.
└─── <product_model_name> ├─── ... ├─── ext └─── ...
fonts (Fonts Used in Product Model)
The one file relating to fonts is standard .
fonts/standard (Standard Font) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
48
fonts/standard (Standard Font)
This file defines the vector representation of all the characters that can be a part of a text feature in a layer.
| standard (Standard Font) | standard (Standard Font) | |----------------------------|------------------------------------------------------------| | Type | Line Record Text | | Compression | None | | Path | <product_model_name>/fonts/standard | | UNITS | The UNITS directive is not relevant for the standard file. |
Size is scaled according to text requirements.
The system supports fully the font named standard. See 'Standard Font' on page 285.
└───
<product_model_name>
├───
...
├───
fonts
│
└───
standard
└───
...
The origin of each character is at the lower left corner. For best results, the font definition should include all ASCII characters.
The file consists of a header containing global parameters, followed by a character block to define each character.
Header Section
The header section consists of these lines:
| Header Line | Explanation | |---------------|-----------------------------------------------------------------------------------------------| | XSIZE <size> | Horizontal size of a character. | | YSIZE <size> | Vertical size of a character. | | OFFSET <size> | Horizontal distance between the end of one character block and the beginning of the next one. |
Character Block
A character block consists of these lines:
| Character Block Line | Explanation | |------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | CHAR <char> | Defines the ASCII character defined by this block. | | LINE <xs> <ys> <xe> <ye> <pol> <shape> <width> | A character specification contains one or more LINE records, each defining a line used to construct the character. • (xs, ys) -Starting point of the line. • (xe, ye) -Ending point of the line. • pol -Polarity of the line (P for positive, N for negative). • shape -The shape of the ends of the line (R for rounded, S for square). • width -Line width in mmor inches. All coordinates are in mmor inches. Because fonts are scaled to a specific text style, units in the font definition are irrelevant. Coordinates and width can be expressed in any units. | | ECHAR | Ends the definition of a character. |
Standard Font Characters
| ! | " | # | $ | % | & | ' | ( | ) | * | + | , | |-----|-----|-----|-----|-----|-----|-----|--------|-----|-----|-----|-----| | - | . | / | 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | | 9 | : | ; | < | = | > | ? | @ | A | B | C | D | | E | F | G | H | I | J | K | L | M | N | O | P | | Q | R | S | T | U | V | W | X | Y | Z | [ | \ | | ] | ^ | _ | ` | a | b | c | d | e | f | g | h | | i | j | k | l | m | n | o | p | q | r | s | t | | u | v | w | x | y | z | { | | | } | ~ | | |
Example of a font file
The file consists of a header containing global parameters, followed by a character block to define each character.
XSIZE 0.302000 YSIZE 0.302000 OFFSET 0.000000 CHAR! LINE 0.000000 0.000000 0.000000 0.200000 P R 0.012000 LINE 0.000000 -0.100000 0.000000 -0.100000 P R 0.012000 ECHAR ... CHAR ~ LINE -0.100000 0.150000 -0.050000 0.200000 P R 0.012000 LINE -0.050000 0.200000 0.050000 0.100000 P R 0.012000 LINE 0.050000 0.100000 0.100000 0.150000 P R 0.012000 ECHAR
input (Input)
This directory is the default location of files for input packages (not ODB++ files) in the product model.
└─── <product_model_name> ├─── ... ├─── input └─── ...
| matrix (Product Model Matrix) | matrix (Product Model Matrix) | |------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------| | The matrix directory of the product model contains the matrix file or the stackup file. If both files exist, the matrix file takes precedence. | The matrix directory of the product model contains the matrix file or the stackup file. If both files exist, the matrix file takes precedence. | | matrix/stackup.xml (Stackup) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 52 | | matrix/matrix (Matrix) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 62 |
matrix/stackup.xml (Stackup)
The stackup file contains all the material information required for the complete manufacturing process of a circuit board. It contains what was previously held in the matrix file with the addition of the material data.
| StackupFile (Stackup) | StackupFile (Stackup) | |-------------------------|-----------------------------------------| | Type | XML | | Compression | None | | Path | <product_model_name>/matrix/stackup.xml |
└─── <product_model_name> ├─── ... ├─── matrix │ └─── stackup.xml └─── ...
The stackup file will replace the matrix file in the next major release of the ODB++ format. In the meantime, the matrix file is required and the stackup file is optional. The format will rely on the matrix file as the primary source of data. If there is an inconsistency, the matrix file will be the primary source of matrix-related ODB++ content.
| Structure of the Stackup File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 53 | |---------------------------------------------------------------------------------------------------|------|
Structure of the Stackup File
The stackup file contains one optional EdaData section and any number of optional SupplierData sections.
The EdaData and SupplierData sections have similar structure-both describe the characteristics of the printed board and its fabrication stackup, with the difference that the EdaData section contains design information retrieved from the CAD data, and the SupplierData section contains information related to the manufacturing and fabrication stackup process.
| EdaData and SupplierData Sections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 54 | |-----------------------------------------------------------------------------------------------------------------------------------|------| | Specs > Spec Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 56 | | Stackup Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 60 |
EdaData and SupplierData Sections
The stackup file contains one optional EdaData section and any number of optional SupplierData sections.
Figure 3-1. Stackup File - EdaData and SupplierData Sections
<!-- image -->EdaData
The EdaData section contains all the stackup-required content as delivered by the design source. This may be a generic section containing basic material requirements and impedance definition, or a full set of stackup definitions provided by a stackup software solution. This section is the basis for all stackup definitions and must not be altered in any way by stackup suppliers.
Child elements:
- Specs - A list of material specifications and impedance requirements for the stack design (1)
- Stackup - Stackup representation by the design source (1)
Example:
<EdaData CompanyName="Valor"> <Specs> ... <Stackup StackupName="Step_1" StackupThickness="85"> ... </EdaData>
The schema is described in 'StackupFile/EdaData' on page 332.
SupplierData
The SupplierData section represents instances of the manufacturing stackup, each with the required content determined by the supplier. This section should contain a full stackup defining the final materials and impedance calculation based on the material of use.
Child elements:
- Specs - A list of material specifications and impedance requirements for the stack design (1)
- Stackup - Stackup representation by a supplier (1)
Example:
<SupplierData CompanyName="BetaBuildOne"> <Specs> ... <Stackup StackupName="Step_1" StackupThickness="85.2"> ... </SupplierData>
The schema is described in 'StackupFile/SupplierData' on page 395.
Specs > Spec Section
The Specs subsection of both EdaData and SupplierData sections includes at least one instance of the Spec element.
Figure 3-2. Stackup File - Spec Section
<!-- image -->Specs
Contains a list of material specifications for the stack design and impedance requirements.
Child elements:
- Spec - Collection of materials and impedance requirements (0-n)
Example:
<Specs> <Spec SpecName="Valor"> ... </Specs>
The schema is described in the following topics:
- 'StackupFile/EdaData/Specs' on page 334.
- 'StackupFile/SupplierData/Specs' on page 397
Spec
An individual specification defining the collection of materials and impedance requirements. The Spec is selected through the use of the SpecName attribute.
Child elements:
- Material - Material specification (0-n)
- Impedance - Impedance specification (0-n)
Example:
<Spec SpecName="Valor"> <Material MaterialName="Soldermask"> ... </Material> <Material MaterialName="0.5 oz CU"> ... <Material MaterialName="Dielectric_1"> ... </Material> <Impedance ImpName="SE 34 ohms" ZoValOhms="34"> ... </Impedance> <Impedance ImpName="SE 38 ohms" ZoValOhms="38"> ... </Impedance> </Spec>
The schema is described in the following topics:
- 'StackupFile/EdaData/Specs/Spec' on page 335.
- 'StackupFile/SupplierData/Specs/Spec' on page 398
Material
A Material specification defining a specific material, dielectric or conductor. The Material is selected through the use of the MaterialName attribute.
Child elements:
- Dielectric - The definition of a specific piece of dielectric material (0-1)
- Conductor - The definition of a specific piece of conductive material (0-1)
- Default_Thickness - The thickness definition for the supplier-delivered dielectric or conductor material (1)
Example:
<Material MaterialName="Soldermask"> <Dielectric DielectricType="OTHER" OtherSubType="SOLDER_MASK"/> <Default_Thickness Thickness="0.5"/> </Material> <Material MaterialName="0.5 oz CU"> <Conductor ConductorType="COPPER" CopperWeight_oz_ft2="0.5"/> <Default_Thickness Thickness="0.7"/> </Material> <Material MaterialName="1.0 oz CU"> <Conductor ConductorType="COPPER" CopperWeight_oz_ft2="1.0"/> <Default_Thickness Thickness="1.4"/> </Material> <Material MaterialName="Dielectric_1"> <Dielectric DielectricType="UNDEFINED"/> <Default_Thickness Thickness="3.6"/> </Material>
The schema is described in the following topics:
- 'StackupFile/EdaData/Specs/Spec/Material' on page 336.
- 'StackupFile/SupplierData/Specs/Spec/Material' on page 399
Impedance
An Impedance specification defining the general impedance goal and physical characteristics. The Impedance is selected through the use of the ImplName attribute.
Child elements:
-
Single_Ended - A representation of the single-ended impedance requirement (0-n)
-
Differential_Coplanar_Waveguide - A representation of the differential Coplanar waveguide impedance requirement (0-n)
-
Differential_Edge_Coupled - A representation of the edge-coupled differential impedance requirement (0-n)
-
Single_Ended_Coplanar_Waveguide - A representation of the Coplanar singleended waveguide impedance requirement (0-n)
-
Differential_Broadside_Coupled - A representation of the broadside-coupled differential impedance requirement (0-n)
Example:
<Impedance ImpName="DIFF100 ohms"> <Differential_Edge_Coupled LayerName="t04" ZoCalculatedOhms="50.8" ZDiffCalculatedOhms="101.5"> <TraceWidth TraceWidthBottom="4.1"/> <Spacing Val="8"/> <RefPlane RefLayerName="g03"/> </Differential_Edge_Coupled> <Differential_Edge_Coupled LayerName="t05" ZoCalculatedOhms="50.8" ZDiffCalculatedOhms="101.5"> <TraceWidth TraceWidthBottom="4.1"/> <Spacing Val="8"/> <RefPlane RefLayerName="p06"/> </Differential_Edge_Coupled> <Differential_Edge_Coupled LayerName="t07" ZoCalculatedOhms="50.3" ZDiffCalculatedOhms="100.5"> <TraceWidth TraceWidthBottom="4.2"/> <Spacing Val="8"/> <RefPlane RefLayerName="p06"/> </Differential_Edge_Coupled> </Impedance>
The schema is described in the following topics:
- 'StackupFile/EdaData/Specs/Spec/Impedance' on page 348.
- 'StackupFile/SupplierData/Specs/Spec/Impedance' on page 411
Stackup Section
Both the EdaData and SupplierData sections include one mandatory instance of the Stackup element.
Figure 3-3. Stackup File - Stackup Section
<!-- image -->Stackup
The stackup representation.
Child elements:
- Group - Collection of Materials in which conductor materials are tied to copper layers of the design (1-n)
Example:
<Stackup StackupName="Step_1" StackupThickness="85"> <Group GroupName="Design"> ... </Group> </Stackup
The schema is described in the following topics:
- 'StackupFile/EdaData/Stackup' on page 385.
- 'StackupFile/SupplierData/Stackup' on page 447
Group
A stackup is created from Groups. A Group is a collection of Materials in which conductor materials are tied to copper layers of the design. Each series is represented from the top of the stack to the bottom.
Child elements:
- Layer - Layer definition within the Group (1-n)
Example:
<Group GroupName="Design"> <Layer LayerName="top" LayerType="SIGNAL" Side="TOP"> ... </Layer> <Layer LayerName="dielectric_1" LayerType="DIELECTRIC" Side="INNER"> ... </Layer> </Group>
The schema is described in the following topics:
- 'StackupFile/EdaData/Stackup/Group' on page 387.
- 'StackupFile/SupplierData/Stackup/Group' on page 449
Layer
A layer definition within the Group.
Child elements:
- SpecRef - The list of Material and Impedance Specs, and conductor requirements for a layer (0-n)
Example:
<Layer LayerName="top" LayerType="SIGNAL" Side="TOP"> <SpecRef MaterialSpecName="Valor"> <Material MaterialName="0.5 oz CU" FrequencyVal="5" CopperAreaPrecent="25"/> </SpecRef> </Layer>
The schema is described in the following topics:
- 'StackupFile/EdaData/Stackup/Group/Layer' on page 389.
- 'StackupFile/SupplierData/Stackup/Group/Layer' on page 451
matrix/matrix (Matrix)
The matrix is a representation of the product model in which the rows are the product model layers-sheets on which elements are drawn for plotting, drilling and routing or assembly; and the columns are the product model steps-multi-layer entities such as single images, assembly panels, production panels and coupons.
| matrix (Matrix) | matrix (Matrix) | |-------------------|----------------------------------------------------------| | Type | Structured Text | | Compression | None | | Path | <product_model_name>/matrix/matrix | | UNITS | The UNITS directive is not relevant for the matrix file. |
Each row of the matrix contains additional information such as the type, polarity and context of the layer.
The matrix defines the physical order of the layers and the relation of drill layers (through, blind, buried, and so forth). A product model can contain only one matrix file.
└─── <product_model_name> ├─── ... ├─── matrix │ └─── matrix └─── ...
Example of a Matrix File
STEP { COL=1 ID=67890 NAME=PCB } STEP { COL=2 NAME=PANEL } ... LAYER { ROW=1 CONTEXT=BOARD TYPE=COMPONENT ID=123456 NAME=COMP_+_TOP POLARITY=POSITIVE START_NAME= END_NAME= OLD_NAME= ADD_TYPE= COLOR=606090 } LAYER { ROW=2 CONTEXT=BOARD TYPE=SILK_SCREEN ID=123457 NAME=SST OLD_NAME = POLARITY=POSITIVE REF=123458 START_NAME= END_NAME= OLD_NAME= ADD_TYPE= COLOR=606090 } ... LAYER { ROW=10 CONTEXT=BOARD TYPE=SIGNAL ID=123458 NAME=top POLARITY=POSITIVE FORM=RIGID START_NAME= END_NAME= OLD_NAME= ADD_TYPE= COLOR=0 } LAYER { ROW=11 CONTEXT=BOARD TYPE=DIELECTRIC ID=123459
NAME=DIELECTRIC_4 POLARITY=POSITIVE DIELECTRIC_TYPE=CORE DIELECTRIC_NAME=FR4 CORE Material FORM=RIGID CU_TOP=123458 CU_BOTTOM=123460 START_NAME= END_NAME= OLD_NAME= ADD_TYPE= COLOR=0 } LAYER { ROW=12 CONTEXT=BOARD TYPE=SIGNAL ID=123460 NAME=signal_2 POLARITY=POSITIVE FORM=RIGID START_NAME= END_NAME= OLD_NAME= ADD_TYPE= COLOR=0 } ... LAYER { ROW=16 CONTEXT=BOARD TYPE=DRILL NAME=DRILL_4_4 POLARITY=POSITIVE START_NAME=sig4 END_NAME=sig5 OLD_NAME= }
| Fields in the STEP Array of a Matrix File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 65 | |-----------------------------------------------------------------------------------------------------------------------------------|------| | Fields in the LAYER Array of a Matrix File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 65 | | Recommended Buildup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 69 | | Layer Subtypes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 70 |
Fields in the STEP Array of a Matrix File
These are the fields in the STEP array of the matrix file:
| Field | Explanation | |---------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------| | COL | The number of the column in the matrix. Column numbers must be unique positive numbers (1 and above). Gaps are allowed between columns. | | ID | A unique ID for the step definition in the matrix (optional). See 'Unique ID' on page 30. | | NAME | Alegal entity name for the step. Each named step must have a step entity defined under the steps directory of the product model. See 'Legal Entity Names' on page 22. |
Fields in the LAYER Array of a Matrix File
These are the fields in the LAYER array of the matrix file:
| Field | Explanation | |---------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | ROW | The number of the row in the matrix. Rows must be unique positive numbers (1 and above). Order is not important, and the numbering need not be sequential. Gaps are allowed between row numbers. See 'Recommended Buildup' on page 69 for a suggested buildup of base type layers. | | CONTEXT | The layer context must be one of these values: BOARD -Alayer that participates in the actual board production. MISC -Anyother layer that is used for drawings, testing, and so forth. |
| Field | Explanation | |----------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | TYPE | The type of layer. For some layer types, sub-layer types can be supplied in the ADD_TYPE field. See 'Layer Subtypes' on page 70. The layer type must be one of these values: • SIGNAL -Alayer used for regular signal transfer. • POWER_GROUND -Aplane layer, used for power or ground signals. • DIELECTRIC -Adielectric layer that separates two copper layers. • MIXED -Acombination of a signal and a plane layer. • SOLDER_MASK -Alayer used for solder mask application. • SOLDER_PASTE -Alayer used for depositing solder paste for assembly. • SILK_SCREEN -Alayer used for application of text legend. • DRILL -Alayer used to produce drill programs. Additional information pertaining to type of drill layer can optionally be applied to this base type. See 'Layer Subtypes' on page 70. • ROUT -Alayer used to produce rout program. • DOCUMENT A layer used for drawings, testing, auxiliary processes, and so forth. • COMPONENT -Alayer containing components locations and outlines. • MASK -Alayer containing additional information used as the base type for all mask types. See 'Layer Subtypes' on page 70. • CONDUCTIVE_PASTE -Alayer used to represent the depositing of conductive materials. | | ID | A unique ID for the layer definition in the matrix (optional). See 'Unique ID' on page 30. | | NAME | A legal entity name for the layer. Each named layer MUST have a layer entity defined under the layers directory of each step in the product model, otherwise the product model might be unreadable. See 'Legal Entity Names' on page 22. | | OLD_NAME | Previous name of the layer. When this field has a value it means that a matrix layer has been renamed and this value is its old name. If the field is blank it means the layer has not been renamed. |
| Field | Explanation | |------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | POLARITY | POSITIVE or NEGATIVE Controls whether the graphic representation of features is to be considered t be solid. In ODB++ format, for POSITIVE copper layers-like SIGNAL, POWER_GROUND, MIXED-the features represent copper; for SOLDER_PASTE layers, features represent paste. For NEGATIVE layers, features represent laminate. This is most commonly used on POWER_GROUND layers where pad features represent clearance, and background content is copper. One exception is the SOLDER_MASKand MASKlayers when polarity is required to be POSITIVE and features represent clearances in the physical mask. COMPONENT, SILKSCREEN, DRILL, ROUT, and DOCUMENTATION layers should always have POSITIVE polarity. This polarity value in the matrix is in no way connected to the intended artwork generation polarity. | | DIELECTRIC_TYP E | Applies to layers of type DIELECTRIC to define the purpose behind the material. (optional) (default = NONE) • NONE -Not defined. • PREPREG -Material that is constructed with fiberglass impregnated with resin. The resin is pre-dried, but not hardened, and when heated, flows to adhere to neighboring material. • CORE -Material that is pre-pressed layers according to a pattern of copper foil - prepreg - copper foil. | | DIELECTRIC_NAM E | Atext field that is intended to carry the material name as reference in the design application. (optional) | | FORM | Defines the layer as ridge or flexible. (optional) (default = RIGID) • RIGID -Layer is defined as rigid. • FLEX -Layer is defined as flexible. Layers of the subtype SIGNAL_FLEX, PG_FLEX and MIXED_FLEX have a default FORM = FLEX. Layers of type DIELECTRIC are to be defined as RIGID or FLEX. | | CU_TOP | Used with layer type DIELECTRIC to indicate that a copper board layer is to be manufactured on top of the DIELECTRIC material. The value is the UID of the layer being referenced. This field would be used as part of a DIELECTRIC_TYPE=CORE definition. (optional) |
| Field | Explanation | |----------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | CU_BOTTOM | Used with layer type DIELECTRIC to indicate that a copper board layer is to be manufactured on bottom of the DIELECTRIC material. The value is the UID of the layer being referenced. This field would be used as part of a DIELECTRIC_TYPE=CORE definition. (optional) | | REF | Establishes a connection for layers within the matrix for the layer types SOLDER_MASK, SOLDER_PASTE, SILK_SCREEN, MASK, or CONDUCTIVE_PASTE with any layer whose type is SIGNAL, POWER_GROUND, or MIXED. This relationship is established through the use of the REF directive, and is to contain the UID of the reference layers. Only layers of type SOLDER_MASK, SOLDER_PASTE, SILK_SCREEN, MASK, or CONDUCTIVE_PASTE can have this tag. For example, consider a build sequence where a solder mask is being applied to an inner layer of a board. Within ODB++ itself, the only relationship between a solder mask layer and the applied outer copper layer is the position of the solder mask in the matrix. If the solder mask layer was to be positioned within a matrix with copper above and below, either could be viewed as the recipient of the mask. The Related Layers (ref) tag would be used to establish the connection to the appropriate copper layer. (optional) | | START_NAME, END_NAME | These fields are active only for drill and rout layers. They specify the span of the drill or rout, in case it is partial (for example, blind or buried via layers). Each field must be a valid board layer name. When the fields are empty, START_NAME is assumed to be the first board layer (that is not a drill or rout layer) and END_NAME is assumed to be the last board layer (that is not a drill or rout layer). The START_NAME and END_NAME are based on the name of the board layers in sequence from the top of the matrix to the bottom, regardless of actual drill direction. The layer attribute .drill_layer_direction is used to specify actual drill direction from the 'top to bottom' or 'bottom to top'. Default drill direction is 'top to bottom'. Therefore, blind drills or backdrills coming up from the bottom would actually start from within the matrix and end on the bottom, and the attribute .drill_layer_direction would be 'bottom2top'. See 'ODB++ System Attributes - Alphabetical List' on page 215. |
| Field | Explanation | |----------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | ADD_TYPE | Contains the layer subtype name. (optional) For example: • PUNCH for layers with base type ROUT. • COVERLAY for layers with base type SOLDER_MASK. • BACKDRILL for layers with base type DRILL. • SILVER_MASK for layers with base type CONDUCTIVE_PASTE. • WIRE_BONDING for layers with base type MASK. See 'Layer Subtypes' on page 70. | | COLOR | RGB defines the recommended color for display of this layer in the layer list. The representation is created using a percentage of red, green and blue. The syntax is COLOR=RRGGBB where RR, GG and BB are numbers between 00-99. For example, COLOR=304050. Default=0, indicating no preference. (optional) |
Recommended Buildup
The ROW element represents the position of the layers in the buildup of the board.
Mask and dielectric layers related to any of the base layers should be placed above and below the relevant layers, as in the actual buildup.
| Layer Type | Recommended Buildup of Base Type Layers | |-----------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | physical layers | • component (top) • solder paste (top) • silk screen (top) • solder mask (top) • all copper layers as ordered in the step • solder mask (bottom) • silk screen (bottom) • solder paste (bottom) • component (bottom) |
| Layer Type | Recommended Buildup of Base Type Layers | |----------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | drill layers | Drill layers according to top to bottom sequence and depth. For example: • Drill penetrating the top layer and extending to the greatest depth. • Drill penetrating the top layer and extending to the second greatest depth, and so forth, until all drills from the top layer are represented. • Drill beginning at the second layer and extending to the greatest depth. • Drill beginning at the second layer and extending to the second greatest depth, and so forth, until all drills from the second layer are represented. • Continuing until all drills are represented by a layer according to the initial point of penetration and the depth. | | rout layer | Rout layer. | | documentation, misc layers | Documentation or Misc layer. |
Layer Subtypes
For some of the base layer types assigned in the TYPE field of the LAYER array of the matrix file, you can assign a layer subtype in the ADD_LAYER field. The tables below list the layer subtypes permitted for the different base layer types.
Layer Subtypes for General Needs
These layer subtypes support general needs in the representation of product models:
| Layer Subtype ADD_LAYER | Base Type TYPE | Description | |---------------------------|------------------|---------------------------------------------| | PUNCH | ROUT | Pattern to be punched by a die-cut fixture. |
Layer Subtypes to Support Backdrill and Dual Diameter Drill
These layer subtypes support the possible unique needs of drill representation in product models. They are subtypes of the DRILL base type:
| Layer Subtype ADD_LAYER | Base Type TYPE | Description | |---------------------------|------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | BACKDRILL | DRILL | Represents a backdrill procedure where the plating within a hole is removed from the unused portion of the matrix using a drill hole slightly larger than the original. This removes the connection from one side of the PCB. | | DUAL_DIAMETER | DRILL | Represents a condition prior to plating where a slightly larger hole is drilled part way through the matrix at the same location as an existing hole. |
Layer Subtypes to Support Embedded Resistors and Capacitors
These layer types support the unique needs of product models containing embedded resistors and embedded capacitors. They are layer subtypes of the MASK base type:
| Layer Subtype ADD_LAYER | Base Type TYPE | Description | |---------------------------|------------------|------------------------------------------------------------| | EMBEDDED_R | MASK | Feature shapes on the layer represent embedded resistors. | | EMBEDDED_C | MASK | Feature shapes on the layer represent embedded capacitors. |
Layer Subtypes to Support Flex/Rigid Flex Manufacturing
These layer types support the unique needs of Flex/Rigid Flex product models. They are subtypes of the indicated base type:
| Layer Subtype ADD_LAYER | Base Type TYPE | Description | |---------------------------|------------------|---------------------------------------------------------------------| | COVERLAY | SOLDER_MASK | Clearances of a coverlay layer. | | COVERCOAT | SOLDER_MASK | Clearances of a covercoat layer. | | STIFFENER | MASK | Shapes and locations where stiffener material is placed on the PCB. | | BEND_AREA | MASK | For labeling areas on the PCB bent when the PCB is in use. |
| Layer Subtype ADD_LAYER | Base Type TYPE | Description | |---------------------------|------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | FLEX_AREA | MASK | Stores the geometries of the flex portions of the board. | | RIGID_AREA | MASK | Stores the geometries of the rigid portions of the board. | | PSA | MASK | Shapes and locations where PSA (Pressure Sensitive Adhesive) material is placed on the PCB. | | AREA | DOCUMENT | Area definition. | | SIGNAL_FLEX | SIGNAL | Signal (copper) layer on flex laminate. Used to distinguish from signal on rigid laminate in rigid-flex boards. | | PG_FLEX | POWER_GROUND | Power and ground (copper) layer on flex laminate. Used to distinguish from power and ground layer on rigid laminate in rigid-flex boards. | | MIXED_FLEX | MIXED | Mixed copper layer-a layer containing both power/ground planes and regular signal pads or traces-on flex laminate. Used to distinguish from a Mixed copper layer on rigid laminate in a rigid- flex board. | | DRAWING | DOCUMENT | Drawing layer definition. | | PLATING_MASK | MASK | Defines which features in the adjacent copper layer should be plated. | | IMMERSION_MASK | MASK | Defines which features are to be covered during immersion in the gold process. | | OSP_MASK | MASK | Defines which features are to be covered with OSP finish. | | SILVER_MASK | CONDUCTIVE_PASTE | Defines the silver mask of the adjacent copper layer. | | CARBON_MASK | CONDUCTIVE_PASTE | Defines the location where carbon ink is applied to copper layers. |
Layer Subtype to Support Wire Bonding
This layer type supports wire bonding. It is a subtypes of the MASK base type:
| Layer Subtype ADD_LAYER | Base Type TYPE | Description | |---------------------------|------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | WIRE_BONDING | MASK | Wire bond connections are stored in separate layers for connections at the top and bottom sides, named wire_bond_+top and wire_bond+_bot. In a wire bond layer, die bumps (pins of source components) are represented by pads bearing attributes .net_name, .comp_name, and .pin_name (used as a link to the netlist file). Wire bonds are represented by lines bearing attribute .bonding_profile. The value of this attribute specifies the bonding order. Direct connection of die bump to copper pad (for flip chip) is represented by lines of zero length. |
Example of a Matrix File Defining a Wire Bond Layer
These matrix file lines define a layer containing wire bond connections.
LAYER { ROW=1 CONTEXT=BOARD TYPE=MASK NAME=WIRE_BOND_+_TOP POLARITY=POSITIVE START_NAME= END_NAME= OLD_NAME= ADD_TYPE=WIRE_BONDING COLOR=9999 ID=6190 }
Example of a Matrix File Defining Layer Subtypes for Flex/Rigid Flex Manufacturing
These matrix file lines define layers with layer subtypes SILVER_MASK, COVERLAY, PG_FLEX, MIXED_FLEX, AREA, and PUNCH:
LAYER { ROW=2 CONTEXT=BOARD TYPE=MASK NAME=SILVER_TOP POLARITY=POSITIVE START_NAME= END_NAME= OLD_NAME=MODPNL.46 ADD_TYPE=SILVER_MASK COLOR=909098 } LAYER { ROW=3 CONTEXT=BOARD TYPE=SOLDER_MASK NAME=CVL1 POLARITY=POSITIVE START_NAME= END_NAME= OLD_NAME= ADD_TYPE=COVERLAY COLOR=208020 } LAYER { ROW=9 CONTEXT=BOARD TYPE=POWER_GROUND NAME=L5 POLARITY=POSITIVE START_NAME= END_NAME= OLD_NAME=PG5 ADD_TYPE=PG_FLEX COLOR=856750 } LAYER { ROW=10 CONTEXT=BOARD TYPE=MIXED NAME=L6 POLARITY=POSITIVE START_NAME= END_NAME= OLD_NAME=MODPNL.06 ADD_TYPE=MIXED_FLEX COLOR=948775 } LAYER { ROW=21 CONTEXT=BOARD
TYPE=DOCUMENT NAME=STIFFENER1_AREA POLARITY=POSITIVE START_NAME= END_NAME= OLD_NAME= ADD_TYPE=AREA COLOR=994171 } LAYER { ROW=10 CONTEXT=MISC TYPE=ROUT NAME=ADH-PUNCH_L2-L3 POLARITY=POSITIVE START_NAME= END_NAME= OLD_NAME= ADD_TYPE=PUNCH COLOR=757575 }
misc (Miscellaneous)
| These files relate to the misc entity. | | |-------------------------------------------------------------------------------------------------------------------------|----| | misc/attrlist (Product Model Attribute List) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 76 | | misc/last_save (Last Time Product Model Saved) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 77 | | misc/info (Basic Product Model Information). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 77 | | misc/metadata.xml (Metadata). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 79 | | misc/sysattr.* (Attribute Definition) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 86 | | misc/userattr (User Attribute Definition) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 92 |
misc/attrlist (Product Model Attribute List)
This file contains the values for system attributes and user-defined attributes assigned to a product model. Only attributes that have been defined are stored in the product model.
You can provide attrlist files at these levels: product model, symbol, wheel, step, layer.
| attrlist (Attributes Used in Product Model) | attrlist (Attributes Used in Product Model) | |-----------------------------------------------|-----------------------------------------------| | Type | Structured Text | | Compression | None | | Path | <product_model_name>/misc/attrlist | | UNITS | The UNITS directive is required. |
System attributes that can be placed in this file are listed with Entity = Product Model in the attribute description. See 'System Attributes' on page 215.
└─── <product_model_name> ├─── ... ├─── misc │ └─── attrlist └─── ...
The file contains lines of this form: <attribute> = <value>
Example of a product model attrlist file
System attribute names begin with a dot. The attribute connector in this example is a userdefined attribute, and therefore does not begin with a dot. For a list of system attributes defined with Entity = Product Model, see 'System Attributes' on page 215.
UNITS=INCH .customer = abc connector = no target = no
misc/last_save (Last Time Product Model Saved)
This file is optional. It is written each time a save operation is performed on a product model. It records the time of the save operation.
| last_save (Last Time Product Model Saved) | last_save (Last Time Product Model Saved) | |---------------------------------------------|-------------------------------------------------------------| | Type | Line Record Text | | Compression | None | | Path | <product_model_name>/misc/last_save | | UNITS | The UNITS directive is not relevant for the last_save file. |
The file consists of a single line that contains the timestamp in format yyyymmdd.hhmmss.
└─── <product_model_name> ├─── ... ├─── misc │ └─── last_save └─── ...
Example of the last_save file
20141224.183210
misc/info (Basic Product Model Information)
This file records basic information about the product model. It is written each time a save operation is performed.
| info (Basic Product Model Information) | info (Basic Product Model Information) | |------------------------------------------|------------------------------------------| | Type | Line Record Text | | Compression | None | | Path | <product_model_name>/misc/info | | UNITS | The UNITS directive is required. |
The UNITS directive in this file governs all product model units unless specifically overridden within the create file or element declaration. See 'Units of Measurement' on page 23.
└─── <product_model_name> ├─── ... ├─── misc │ └─── info └─── ...
This information is stored in the info file:
| Field | Explanation | |--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------| | PRODUCT_MODEL_NAME | Legal name of the product model. | | ODB_VERSION_MAJOR | Major version designation such as 8 in Version 8.0, expressed as a numeric string. This can provide the application with a way to verify compatibility. | | ODB_VERSION_MINOR | Minor version designation such as 0 in Version 8.0, expressed as a numeric string. | | ODB_SOURCE | Source of data, typically a CAD/EDA system name of up to 500 characters. | | CREATION_DATE | Creation date in the format yyyymmdd.hhmmss. | | SAVE_DATE | Save date in the format yyyymmdd.hhmmss. | | SAVE_APP | Name and number of the application in which the product model was saved, along with the currently running software version in up to 100 characters. | | SAVE_USER | Login name of the user saving the file, in up to 50 characters (optional). | | UNITS | Units used by default for this product model. (UNITS=MM|INCH). | | MAX_UID | The largest numerical unique ID in the product model (optional). See 'Unique ID' on page 30. |
Example of the info file
UNITS=MM PRODUCT_MODEL_NAME=k10025_cd2 ODB_VERSION_MAJOR=8 ODB_VERSION_MINOR=0 ODB_SOURCE=Expedition CREATION_DATE=20110727.091213 SAVE_DATE=20110727.091230 SAVE_APP=Valor NPI 9.2 SAVE_USER=mikel MAX_UID=57394
misc/metadata.xml (Metadata)
Product description information is provided in a file named metadata.xml , stored in the misc directory of the product model.
| metadata (Metadata) | metadata (Metadata) | |-----------------------|----------------------------------------------------------------| | Type | XML | | Compression | None | | Path | <product_model_name>/misc/metadata.xml | | UNITS | The UNITS directive is not relevant for the metadata.xml file. |
The purpose of metadata is to support manufacturing process-cost calculation, and the generation of the Manufacturing Product Definition (MPD) during the early stage of the New Product Introduction (NPI) process. This data is made available immediately, without needing to process the ODB++ product model.
└─── <product_model_name> ├─── ... ├─── misc │ └─── metadata.xml └─── ...
The file is not case sensitive.
See 'Metadata Example' on page 312.
Data is added to the metadata as the product model moves through the flow processes.
| Structure of the Metadata File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 79 | |---------------------------------------------------------------------------------------------------------------------------------------|------| | Metadata Sections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 81 | | Metadata Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 82 | | Attributes of a Metadata Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 82 | | Collective Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 83 |
Structure of the Metadata File
A metadata file can contain several types of element.
| Element | Explanation | |------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | metadata section | The metadata is divided into sections that indicate the type of metadata: • Header • Requirements • Manufacturing • Assembly • Final Metadata that applies to the product model is placed in metadata sections at the top level of the hierarchy. Metadata that applies to a specific step is placed in metadata sections that are child elements of a step section. See 'Metadata Sections' on page 81. | | steps section | The steps section contains one or more step sections. This is the syntax of the steps element: <Steps description = 'Steps'> </Steps> The description is optional. | | step section | The start-tag of each step section indicates the name of the step. Between the start-tag of the step and its end-tag, are metadata sections containing metadata that applies to that step. This is the syntax of the step element: <step name="nnn" description="ddd" > </step> The description is optional. | | node | These elements contain the metadata. Each node element must be placed in the appropriate metadata section. See 'Metadata Types' on page 82. See 'Attributes of a Metadata Node' on page 82. | | classify_by | Some nodes can contain be classified by one or more levels of classes. See 'Collective Data' on page 83. |
This illustrates the structure of a metadata file:
<!-- image -->Metadata Sections
The metadata is divided into sections that indicate the type of metadata.
Some sections can be specified at the level of the product model, and some sections can be specified only in a step section of the file.
The information that can be specified in each section is listed in 'Metadata Content' on page 300. For each node, there is an indication of whether the node can be specified at the product model level or at the step level:
| Section | Explanation | Level | Content | |---------------|----------------------------------------------------|-----------------------|----------------------------------------------| | Header | General information about the product or the step. | product model or step | 'Header Metadata Section' on page 300 | | Requirements | Overall requirements specified by the designer. | product model or step | 'Requirements Metadata Section' on page 301 | | Manufacturing | Manufacturing information. | step | 'Manufacturing Metadata Section' on page 306 | | Assembly | Assembly information. | step | 'Assembly Metadata Section' on page 310 | | Final | Quality assurance and delivery information. | product model or step | 'Final Metadata Section' on page 311 |
The metadata section elements have this syntax. The description attribute is optional.
| Element | Syntax | |---------------|-----------------------------------------------------| | Header | <header description='ddd' /> </header> | | Requirements | <requirements description='ddd' /> </requirements> | | Manufacturing | <manufacturing description='ddd' /> </manufacturer> | | Assembly | <assembly description='ddd' /> </assembly> | | Final | <final description='ddd' /> </final> |
Metadata Types
Each value stored in the metadata file is of one of these data types:
| Type | Description | |-----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Boolean | A value of either yes or no. | | Integer | A value expressed as an integer. | | Float | A value expressed as a decimal number. A node of this type can be of one of these unit types: • distance -Represents distance. • size -Represents the size of a feature. • temperature -Represents temperature. • area -Represents area. | | Text | Text strings of printable ASCII characters. | | Option | One of the legal values. | | TextWithOptions | One of the suggested values or another text string. |
Attributes of a Metadata Node
Metadata is specified in node statements.
It has this syntax:
<node name="nnn", value="vvv", units="uuu", layer="lll", display="ddd" />
See 'Metadata Content, Example, and Schema' on page 299.
These are the attributes of the node element:
| Attribute | Description | Legal Values | Required | |-------------|----------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------|-------------------------------| | name | Name of the information. | A name in 'Metadata Content' on page 300. | required | | value | A value stored for future reference by its metadata content name. | Legal values based on the type of content stored. | | | units | Units of measure. Permitted values for units correspond to those defined in 'Units of Measurement' on page 23. | distance -inch ormm size -inch ormm temperature - fahrenheit or centigrade area -square mmor square inch | Required only for float data. | | layer | The name of the layer to which the name/ value pair is assigned. | A layer name located in the product model matrix. | optional | | display | Suggested text for the application display. | ASCII text characters. | optional |
Collective Data
In some cases, metadata content can represent a collection of similar data-for example, the number of components classified by type. In such a case, classify_by elements are included in the file.
This is the syntax:
<classify_by name="nnn", value="vvv", units="uuu", layer="lll", display="ddd" />
Classification is recursive, and can include an additional level of classification. component_count can be classified by two parameters: layer and technology. The corresponding segment of the metadata file looks like this:
<node name=component_count value= 30 display=Component Count > <classify_by name=top value=10 display="Components in Top Layer:" > <classify_by name=bga value=5 /> <classify_by name=axial value=5 /> </classify_by> <classify_by name=Layer3 value=10 display="Components in Inner Layer 3" > <classify_by name=bga value=5 /> <classify_by name=axial value=5 /> </classify_by> <classify_by name=bottom value=10 display="Components in Bottom Layer:" > <classify_by name=bga value=5 /> <classify_by name=axial value=5 /> </classify_by> </node>
This is an example report that could be generated from the component_count segment.
| | Layer | Technology | Value | |---------------------|----------------------|--------------|---------| | Component Count | Total for all layers | | 30 | | Components in layer | Top Layer | | 10 | | | | bga axial | 5 5 | | Components in layer | Inner Layer 3 | | 10 | | | | bga axial | 5 5 | | Components in layer | Bottom Layer | | 10 | | | | bga axial | 5 5 |
This metadata content requires classification:
| Name | Display Name | Classified by | |----------------------------|----------------------------|-------------------| | component_count | Components per Step | layer, technology | | number_of_nets_with_probes | Number of Nets with Probes | layer, size | | number_of_fiducials | Number of Fiducials | layer | | total_number_of_smd_pads | Total Number of SMD Pads | layer | | number_of_test_points | Number of Test Points | side |
| Name | Display Name | Classified by | |------------------------------|----------------------------|-----------------------------------------| | number_of_drill_holes | Number of Drill Holes | layer | | number_of_tooling_holes | Number of Tooling Holes | layer | | number_of_un- connected_nets | Number of Unconnected Nets | layer | | number_of_single_pin_nets | Number of Single Pin Nets | layer | | number_of_multi_pin_nets | Number of Multi-pin Nets | layer | | cad_package_analysis | CAD Package Analysis | layer, CAD package, pin_count and pitch |
misc/sysattr.* (Attribute Definition)
Attribute definition files for all attributes in the product model are stored under <product_model_name>/misc . They all have the same syntax. Attributes starting with the dot (.) character are system attributes (some system attributes must be defined for certain processes, such as analysis). User-defined attributes cannot have the dot character before their name.
| sysattr, sysattr.dfm, sysattr.fab, sysattr.assy, sysattr.test, sysattr.gen | sysattr, sysattr.dfm, sysattr.fab, sysattr.assy, sysattr.test, sysattr.gen | |------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Type | Line Record Text | | Compression | None | | Path | <product_model_name>/misc/sysattr <product_model_name>/misc/sysattr.dfm <product_model_name>/misc/sysattr.fab <product_model_name>/misc/sysattr.assy <product_model_name>/misc/sysattr.test <product_model_name>/misc/sysattr.gen | | UNITS | The UNITS directive is required. |
Every attribute definition file contains a list of definitions, defined at the time the product model was created. It is read each time the product model is opened.
<!-- image -->For a discussion of ODB++ attributes, see 'ODB++ Attributes' on page 27.
For a discussion of user defined attributes, see 'misc/userattr (User Attribute Definition)' on page 92.
| Attribute Type | Description | |------------------------------|--------------------------------------------------| | BOOLEAN Attribute Definition | Attributes that have values of either YES or NO. |
| Attribute Type | Description | |------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------| | TEXT Attribute Definition | Attributes that are text strings have values comprised of printable ASCII characters, and with a length range specified by the attribute definition. | | OPTION Attribute Definition | Attributes that have values limited to a list of options supplied as part of the attribute definition. | | INTEGER Attribute Definition | Attributes that have a numerical integer value within the range defined by the attribute definition. | | FLOAT Attribute Definition | Attributes that have numeric values that can also contain decimal notation within the range defined in the attribute definition. |
BOOLEAN Attribute Definition
Attributes that have values of either YES or NO.
| Field | Explanation | |---------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | NAME | Name of the attribute. | | PROMPT | The name used on screen when this attribute is displayed (Optional). | | ENTITY | The entities for which this attribute is applicable. A semicolon (;) separated list of entity types: JOB, STEP, SYMBOL, LAYER, BUILDUP, WHEEL, FEATURE, COMPONENT, or PACKAGE. | | GROUP | Name of the class to which this attribute belongs. This could be DFM Analysis, Product, Process: Fabrication, Assembly, Test, Generic, or other. See 'Attribute Classes' on page 27. | | DEF | The default value of the attribute, if no value is specified. If the DEF keyword is missing or not defined, the suggested default is NO. |
Example
BOOLEAN { NAME = .string_mirrored ENTITY = FEATURE DEF = NO GROUP = Fabrication PROMPT = String Mirror }
TEXT Attribute Definition
Attributes that are text strings have values comprised of printable ASCII characters, and with a length range specified by the attribute definition.
| Field | Explanation | |---------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | NAME | Name of the attribute. | | PROMPT | The name used on screen when this attribute is displayed (Optional). | | OPTIONS | A semicolon (;) separated list of options. Unlike other Options lists, the text attribute is used to provide a selection of the most commonly used values. | | MIN_LEN | Minimum number of characters allowed in the value of the attribute. | | MAX_LEN | Maximum number of characters allowed in the value of the attribute. | | ENTITY | The entities for which this attribute is applicable. A semicolon (;) separated list of entity types: JOB, STEP, SYMBOL, LAYER, BUILDUP, WHEEL, FEATURE, COMPONENT, or PACKAGE. | | GROUP | Name of the class to which this attribute belongs. This could be DFM Analysis, Product, Process: Fabrication, Assembly, Test, Generic, or other. See 'Attribute Classes' on page 27. | | DEF | The default value of the attribute, if no value is specified. If the DEF keyword is missing or not defined, the suggested default is an empty string. |
Example
TEXT { NAME = .string OPTIONS = ENTITY = FEATURE MIN_LEN = 0 MAX_LEN = 1000 GROUP = Feature DEF = PROMPT = Copper Text String }
OPTION Attribute Definition
Attributes that have values limited to a list of options supplied as part of the attribute definition.
| Field | Explanation | |---------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | NAME | Name of the attribute. | | PROMPT | The name used on screen when this attribute is displayed (Optional). | | OPTIONS | A semicolon (;) separated list of options. | | DELETED | A semicolon (;) separated list of the values YES and NO. Only an index number to the list of options in the OPTIONS field is stored within the format. Therefore, the removal of an existing option is not allowed. The list of corresponding YES or NO values indicates whether an option is available for use. Avalue of YES indicates that the corresponding OPTIONS value is to be ignored. | | ENTITY | The entities for which this attribute is applicable. A semicolon (;) separated list of entity types: JOB, STEP, SYMBOL, LAYER, BUILDUP, WHEEL, FEATURE, COMPONENT, or PACKAGE. | | GROUP | Name of the class to which this attribute belongs. This could be DFM Analysis, Product, Process: Fabrication, Assembly, Test, Generic, or other. See 'Attribute Classes' on page 27. | | DEF | The default value of the attribute, if no value is specified. If the DEF keyword is missing or not defined, the suggested default is the first value in the OPTIONS list. |
Example
In this example, option both is defined as being logically deleted.
OPTION { NAME=.viacap_layer PROMPT=Via Capping on Layer OPTIONS=top;bottom;both;none DELETED=NO;NO;YES;NO ENTITY=step DEF=none GROUP=Custom }
INTEGER Attribute Definition
Attributes that have a numerical integer value within the range defined by the attribute definition.
| Field | Explanation | |---------|------------------------| | NAME | Name of the attribute. |
| Field | Explanation | |---------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | PROMPT | The name used on screen when this attribute is displayed (Optional). | | MIN_VAL | Minimum value for the integer attribute. | | MAX_VAL | Maximum value for the integer attribute. | | ENTITY | The entities for which this attribute is applicable. Asemicolon (;) separated list of entity types of: JOB, STEP, SYMBOL, LAYER, BUILDUP, WHEEL, FEATURE, COMPONENT, or PACKAGE. | | GROUP | Name of the class to which this attribute belongs. This could be DFM Analysis, Product, Process: Fabrication, Assembly, Test, Generic, or other. See 'Attribute Classes' on page 27. | | DEF | The default value of the attribute, if no value is specified. If the DEF keyword is missing or not defined, the suggested default is MIN_VAL. |
Example
INTEGER { NAME = .num_local_fiducials ENTITY = COMPONENT DEF = 0 MIN_VAL = 0 MAX_VAL = 20 GROUP = DFx Component PROMPT = Number Local Fiducials Required }
FLOAT Attribute Definition
Attributes that have numeric values that can also contain decimal notation within the range defined in the attribute definition.
| Field | Explanation | |---------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | NAME | Name of the attribute. | | PROMPT | The name used on screen when this attribute is displayed (Optional). | | MIN_VAL | Minimum value for the float attribute. | | MAX_VAL | Maximum value for the float attribute. | | ENTITY | The entities for which this attribute is applicable. Asemicolon (;) separated list of entity types of: JOB, STEP, SYMBOL, LAYER, BUILDUP, WHEEL, FEATURE, COMPONENT, or PACKAGE. |
| Field | Explanation | |-----------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | GROUP | Name of the class to which this attribute belongs. This could be DFM Analysis, Product, Process: Fabrication, Assembly, Test, Generic, or other. See 'Attribute Classes' on page 27. | | DEF | The default value of the attribute, if no value is specified. If the DEF keyword is missing or not defined, the suggested default is MIN_VAL. | | UNIT_TYPE | DISTANCE, WEIGHT, TEMPERATURE, AREA, RESISTANCE, COPPER_WEIGHT, VOLTAGE, CURRENT. Determines the units used in accordance with the type of measurement. (Default = DISTANCE) See 'Units of Measurement' on page 23. | | UNITS | Default = NO_UNITS • When UNIT_TYPE=DISTANCE -Possible values areINCH_MM or MIL_MICRONS. This affects the way the value is interpreted-inch or mil, millimeter or micron. • When UNIT_TYPE=RESISTANCE -Possible values are OHMor NANO_OHM. This affects the way the value is interpreted-ohms or nano-ohms. (Default for RESISTANCE is OHM) The UNITS field does not apply to other UNIT_TYPE values. You can use the UNITS line to specify the units in which the values of MIN_VAL and MAX_VAL are given. The way in which the UNITS line of the attribute is interpreted depends on the UNITS directive at the top of the file. See the examples. |
Example
FLOAT { NAME = .local_fiducial_dist ENTITY = COMPONENT MIN_VAL = 0.0 MAX_VAL = 100.0 UNITS = INCH_MM PROMPT = Search Distance for Local Fiducial GROUP = Assembly DEF = 50.0 }
Example: UNITS directive = MM and UNITS line = MIL_MICRON
In this example, MAX_VAL is interpreted as 100 micron. The directive UNITS=MM specifies that measurements in the file are given in metric units. The attribute definition contains the line
UNITS=MIL_MICRON, which specifies that if units of measurement are metric, the measurements are to be interpreted as microns.
UNITS=MM ... FLOAT { NAME=.spacing_reg ENTITY=FEATURE MIN_VAL=0.0 MAX_VAL=100.0 UNITS=MIL_MICRON GROUP=DFx Feature PROMPT=Spacing Required DEF=25.0 }
Example: UNITS directive = INCH and UNITS line = MIL_MICRON
In this example, MAX_VAL is interpreted as 100 mil (0.1 inch). The directive UNITS=INCH specifies that measurements in the file are given in imperial units. The attribute definition contains the line UNITS=MIL_MICRON, which specifies that if units of measurement are imperial, the measurements are to be interpreted as mils.
UNITS=INCH ... FLOAT { NAME=.spacing_reg ENTITY=FEATURE MIN_VAL=0.0 MAX_VAL=100.0 UNITS=MIL_MICRON GROUP=DFx Feature PROMPT=Spacing Required DEF=0.025 }
misc/userattr (User Attribute Definition)
User-defined attributes cannot have the dot character before their name.
| userattr | userattr | |-------------|------------------------------------| | Type | Line Record Text | | Compression | None | | Path | <product_model_name>/misc/userattr | | UNITS | The UNITS directive is required. |
The user attribute definition file contains a list of definitions, defined at the time the product model was created. It is read each time the product model is opened.
<!-- image -->The format of user attribute definitions is the same as the format of system attribute definitions. See 'misc/sysattr.* (Attribute Definition)' on page 86.
For a discussion of ODB++ attributes, see 'ODB++ Attributes' on page 27.
steps
Steps are multi-layer entities such as a single image, an assembly panel, a fabrication panel, or a fabrication coupon. Each step contains a collection of layers. Layers are two-dimensional sheets, containing graphics, attributes and annotation.
For information on the steps directory of the product model, see 'Step Entities' on page 99.
symbols (User-Defined Symbols)
Symbols are single layer graphic entities that can be referenced from within any graphic layer in a step. ODB++ format can handle both standard symbols and user-defined symbols.
Standard symbols are rendered dynamically from their name. Standard symbols do not require any files. See 'Standard Symbols' on page 36.
User-defined symbols require these files:
| <symbol_name>/attrlist (Symbol Attribute List) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 94 | |--------------------------------------------------------------------------------------------------------------|------| | <symbol_name>/features (Symbol Features) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 95 |
<symbol_name>/attrlist (Symbol Attribute List)
This file contains the values for system attributes and user-defined attributes assigned to a symbol.
You can provide attrlist files at these levels: product model, symbol, wheel, step, layer.
| attrlist (Attribute List) | attrlist (Attribute List) | |-----------------------------|-----------------------------------------------------| | Type | Structured Text | | Compression | None | | Path | <product_model_name>/symbols/<symbol_name>/attrlist | | UNITS | The UNITS directive is required. |
System attributes that can be placed in this file are listed with Entity = Symbol in the attribute description. See 'System Attributes' on page 215.
└─── <product_model_name> ├─── ... ├─── symbols │ ├─── <symbol_name> │ │ └─── attrlist └─── ...
The file contains lines of this form: <attribute> = <value>.
Example of an attrlist file for a Symbol
UNITS=INCH .out_break = no .out_scale = no .break_away = no .fill_dx = 0.100000 .fill_dy = 0.100000 .image_dx = -1.000000 .image_dy = -1.000000 connector = no target = no component = comment = hole_type = plated serial_number = 15
<symbol_name>/features (Symbol Features)
Each user-defined symbol has a features file to define its shape.
| features (Symbol Features) | features (Symbol Features) | |------------------------------|-----------------------------------------------------| | Type | Line Record Text | | Compression | Yes | | Path | <product_model_name>/symbols/<symbol_name>/features | | UNITS | The UNITS directive is required. |
The symbol features file describes the graphic shape of the symbol.
└─── <product_model_name> ├─── ... ├─── symbols │ └─── <symbol_name> │ └─── features └─── ...
The file is similar in structure to the layer features file. See '<layer_name>/features (Graphic Features)' on page 170.
user (User)
This directory is the location to store user files.
└─── <product_model_name> ├─── ... ├─── user └─── ...
wheels (Gerber and Tool Wheels)
Wheels are aperture tables used for the correct translation of Gerber 274D files and/or drill/rout files with external tool definitions. These files relate to the wheels entity of the product model:
<wheel_name>/attrlist (Wheel Attribute List) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 <wheel_name>/dcodes (Dcodes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
<wheel_name>/attrlist (Wheel Attribute List)
This file contains the values for system attributes and user-defined attributes assigned to a wheel.
You can provide attrlist files at these levels: product model, symbol, wheel, step, layer.
| attrlist (Attributes Values) | attrlist (Attributes Values) | |--------------------------------|---------------------------------------------------| | Type | Structured Text | | Compression | None | | Path | <product_model_name>/wheels/<wheel_name>/attrlist | | UNITS | The UNITS directive is required. |
System attributes that can be placed in this file are listed with Entity = Wheel in the attribute description. See 'System Attributes' on page 215.
└─── <product_model_name> ├─── ... ├─── wheels │ └─── <wheel_name> │ └─── attrlist └─── ...
The file contains lines of this form: <attribute> = <value>
Example of a wheel attrlist file
UNITS=MM
comment=Mentor wheel
<wheel_name>/dcodes (Dcodes)
This file lists dcodes. A dcode is a Gerber dcode number or an Excellon tool number.
| dcodes | dcodes | |----------|------------------| | Type | Line Record Text |
| dcodes | dcodes | |-------------|----------------------------------------------------------| | Compression | None | | Path | <product_model_name>/wheels/<wheel_name>/dcodes | | UNITS | The UNITS directive is not relevant for the dcodes file. |
This file saves the wheel used during Gerber input for translation purposes. Once the file is processed, both the dcodes and Gerber file are no longer referenced.
└─── <product_model_name> ├─── ... ├─── wheels │ └─── <wheel_name> │ └─── dcodes └─── ...
Each line in the file has this format: dcode<n> <symbol_name> <angle> <mirror>
| Field | Explanation | |-------------|-------------------| | n | Dcode number. | | symbol_name | Symbol name. | | angle | Always 0. | | mirror | Always no_mirror. |
Example of a dcodes file
dcode10 r12 0 no_mirror dcode11 r50 0 no_mirror dcode12 r60 0 no_mirror dcode13 r10 0 no_mirror dcode14 r70 0 no_mirror dcode15 r80 0 no_mirror dcode17 r5 0 no_mirror
Chapter 4 Step Entities
Steps are multi-layer entities such as a single image, an assembly panel, a fabrication panel, or a fabrication coupon. Each step contains a collection of layers. Layers are two-dimensional sheets, containing graphics, attributes and annotation. Layers express physical board layers, mask layers, NC drill and rout layers and miscellaneous drawings. All steps in one product model have the same list of layers, even though the contents might be different.
A step is capable of referencing the content of another step, thereby graphically including its content. The referenced step must be within the product model. When this occurs, the layer content for the referenced step appears on the primary step. This process can be repeated any number of times. The most commonly used term for describing this capability is step and repeat, used to create fabrication and assembly panels. Within the primary step, feature display is first defined by the sequence within the referenced step's feature container, then the sequence the steps are added to the primary step, and finally the feature sequence as defined by the primary step's feature container. For more information about feature sequence, see 'Geometric Entities' on page 39.
This section describes each element of the step entity.
| <step_name>/attrlist (Step Attribute List) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 100 | |-------------------------------------------------------------------------------------------------------------------------------|-------| | <step_name>/boms (Bill of Materials). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 101 | | <bom_name>/bom (Bill Of Materials). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 101 | | <bom_name>/files (Source Files). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 106 | | <step_name>/eda (Electronic Design Automation) . . . . . . . . . . . . . . . . . . . . . . . . . . . | 108 | | eda/data (EDA Data). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 109 | | eda/shorts (Electrical Intention Short Net) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 120 | | eda/hdi_netlist (HDI Netlist) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 126 | | <step_name>/impedance.xml (Impedance) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 132 | | Structure of the Impedance File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 133 | | <step_name>/layers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 134 | | <step_name>/netlists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 135 | | cadnet/netlist (cadnet) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 135 | | refnet/netlist (Reference) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 141 | | <step_name>/profile (Outline Shape of Step) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 141 | | <step_name>/stephdr (Step Header) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 143 | | <step_name>/zones (Matrix Broken Into Sections) . . . . . . . . . . . . . . . . . . . . . . . . . . . | 145 |
<step_name>/attrlist (Step Attribute List)
This file contains the values for system attributes and user-defined attributes assigned to a step.
You can provide attrlist files at these levels: product model, symbol, wheel, step, layer.
| attrlist (Attribute List) | attrlist (Attribute List) | |-----------------------------|-------------------------------------------------| | Type | Structured Text | | Compression | None | | Path | <product_model_name>/steps/<step_name>/attrlist | | UNITS | The UNITS directive is required. |
System attributes that can be placed in this file are listed with Entity = Step in the attribute description. See 'System Attributes' on page 215.
└─── <product_model_name> ├─── ... ├─── steps │ └─── <step_name> │ └─── attrlist └─── ...
The file contains lines of this form: <attribute> = <value>
Example of the attrlist file
In the example, comment is a user-defined attribute, so it does not begin with a dot.
UNITS=MM .board_thickness=50 .out_drill_full = no .out_drill_optional = no .out_rout_optional = no .fs_direction_top = left2right .fs_direction_bottom = right2left comment = Production Step
<step_name>/boms (Bill of Materials)
The boms directory of the step contains a directory for each BOM associated with the step. The name of the directory is the name of the BOM.
The directory for each BOM contains a file named bom and a directory named files .
See 'Component Variants' on page 41.
| <bom_name>/bom (Bill Of Materials). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 101 | |-------------------------------------------------------------------------------------------------------------------------|-------| | <bom_name>/files (Source Files) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 106 |
<bom_name>/bom (Bill Of Materials)
The BOM file describes the Bill of Materials for a board. It is a list of the components that can be used in assembling the electronic product.
| bom | bom | |-------------|------------------------------------------------------------| | Type | Line Record Text | | Compression | None | | Path | <product_model_name>/steps/<step_name>/boms/<bom_name>/bom | | UNITS | The UNITS directive is not relevant for the bom file. |
Each component contains a list of attributes and its uses or locations in the electronic product being assembled.
└─── <product_model_name> ├─── ... ├─── steps │ └─── <step_name> │ └─── boms │ └─── <bom_name> │ └─── bom └─── ...
Each LNFILE line in the bom file indicates that source information for the preceding line is stored in the indicated file in the <bom_name>/files directory. The LNFILE line provides the line number and the file name. For example, LNFILE 5 Rev14.v1 indicates that information is stored in line 5 of file Rev14.v1 .
The file ends with a FILE_END record.
The bom file contains these sections: HEADER, DESC_ALIASES, RS_CPN, CPN_MPN, CP.
HEADER Section
The header section of the bom file contains these parameters:
| Parameter | Description | |-------------|------------------------------------------| | HEADER | Signals the start of the header section. | | BRD | Board number. | | REV | Revision. | | HEADER_END | Signals the end of the header section. |
DESC_ALIASES Section
The DESC_ALIASES section of the bom file provides aliases for CPN and MPN descriptions to enable terms to be displayed in the language of the product model creator.
| Parameter | Description | |-------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | DESC_ALIASES | Signals the start of the DESC_ALIASES section. | | LANG | The language code of the product model creator: • c -English. • ja -Japanese. • gb -Simplified Chinese. • big5 -Traditional Chinese. • ko -Korean. | | INDEX | Anumber that provides the link between an alias and a description in the CP section. The index starts at 1 and increases. For example, an alias with an index of 3 corresponds to the third description (DSC) of every CPN in the CP section. | | CPN or MPN | The alias for the CPN field or the MPN field in either English or a specified language. | | DESC_ALIASES_E ND | Signals the end of the DESC_ALIASES section. |
RD_CPN Section
The RD_CPN section of the bom file lists the Reference Designators and their matching Customer Part Numbers:
A LNFILE entry is saved for each REF and CPN.
| Parameter | Description | |-------------|-----------------------------------------| | RD_CPN | Signals the start of the RD_CPN section | | REF | Reference designator name. | | CPN | Customer part number. | | RD_CPN_END | Signals the end of the RD_CPN section. |
CPN_MPN Section
The CPN_MPN section of the bom file lists Customer Parts and their matching Manufacturer Parts
A LNFILE entry is saved for each CPN, MPN, and VND.
| Parameter | Description | |-------------|-----------------------------------------------------------------------------------------------------------------------------------| | CPN_MPN | Signals the start of the CPN_MPN section. | | CPN | Customer part number. | | VPL_MPN | MPN from an external vendor part library corresponding to the original MPN (as determined in BOMValidation). | | VPL_VND | Manufacturer from an external vendor part library corresponding to the original vendor (as determined in BOMValidation). | | MPN | Manufacturer part number. | | VND | Manufacturer (vendor) name. | | QLF | Indicates whether the part (MPN+VND) is qualified for production: -1 -Not qualified. 0 -Unknown. 1 -Qualified. | | CHS | Indicates whether this part is chosen from among the alternate parts for the CPN. Only one alternate can be designated as chosen. | | CPN_MN_END | Signals the end of the CPN_MPN section. |
CP Section
The CP section of the bom file lists Customer Part Numbers and their descriptions.
A LNFILE entry is saved for each CPN, IPN, DSC, and PKG.
| Parameter | Description | |-------------|--------------------------------------| | CP | Signals the start of the CP section. |
| Parameter | Description | |-------------|------------------------------------| | CPN | Customer part number. | | IPN | Internal part number. | | DSC | Unlimited number of descriptions. | | PKG | CAD package name. | | QNT | Reference designator quantity. | | ITEM | Item number. | | CP_END | Signals the end of the CP section. |
Example of a bom file
Header Parameters
HEADER
BRD
REV
HEADER_END
Description Aliases
DESC_ALIASES
LANG fr
INDEX 1
CPN Cout
CPN Cost
INDEX 1
MPN Benefice
MPN Profit Margin
DESC_ALIASES_END
Reference Descriptors and matching Customer Parts
RD_CPN
REF XTAL1
LNFILE 5 Rev14.v1
CPN 004-020-101
LNFILE 5 Rev14.v1
REF Y8 LNFILE 7 Rev14.v1 CPN 004-040-101
LNFILE 7 Rev14.v1
RD_CPN_END
Customer Parts and Matching Manufacturer Parts
CPN_MPN
CPN 004-020-101
LNFILE 5 Rev14.v1
VPL_MPN
VPL_VND TOYOCOM
MPN TQC-216C-6R
LNFILE 5 Rev14.v1
VND TOYOCOM
LNFILE 5 Rev14.v1
QLF 0
CHS 1
CPN 004-020-101
LNFILE 5 Rev14.v1
VPL_MPN
VPL_VND VF
MPN VM6S-20.0000-16PF
LNFILE 6 Rev14.v1
VND VALPEY-FISHER
LNFILE 6 Rev14.v1
QLF 0
CHS 0
CPN_MPN_END
# Customer Parts and Description CP CPN 004-020-101 LNFILE 5 Rev14.v1 IPN LNFILE 5 Rev14.v1 DSC 5 OHM LNFILE 5 Rev14.v1 DSC UL Listed LNFILE 5 Rev14.v1 DSC Weight 4 LNFILE 5 Rev14.v1 DSC Price 18 LNFILE 5 Rev14.v1 DSC LNFILE 10 OHM Rev14.v1 PKG LNFILE 5 Rev14.v1 QNT 1 ITEM 0 CPN 004-040-101 LNFILE 7 Rev14.v1 IPN LNFILE 7 Rev14.v1 DSC 5 OHM LNFILE 7 Rev14.v1 DSC Weight 3 LNFILE 7 Rev14.v1 DSC Price 24 LNFILE 7 Rev14.v1 DSC Height 0.05 LNFILE 7 Rev14.v1 DSC UL Listed LNFILE 7 Rev14.v1 PKG LNFILE 7 Rev14.v1 QNT 1 ITEM 0 CP_END FILE_END
<bom_name>/files (Source Files)
The files directory contains the source files that generated the bom entity (BOM and AVL).
<!-- image -->LNFILE lines in the bom file point to information stored in these files.
<step_name>/eda (Electronic Design Automation)
| Several files are stored in the eda directory. | | |---------------------------------------------------------------------------------------------------------------------------------|-----| | eda/data (EDA Data) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 109 | | eda/shorts (Electrical Intention Short Net) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 120 | | eda/hdi_netlist (HDI Netlist) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 126 |
eda/data (EDA Data)
This file contains information that is read from the EDA system directly.
| data | data | |-------------|-------------------------------------------------| | Type | Line Record Text | | Compression | Yes | | Path | <product_model_name>/steps/<step_name>/eda/data | | UNITS | The UNITS directive is required. |
It covers the library of CAD and user-defined component packages, their outlines and properties, and net connectivity information.
<!-- image -->This is an example of an eda data file:
# HDR Mentor Boardstation database UNITS=MM LYR sst sst+1 sigt sig2 sig3 sig4 sig7 sig8 sig9 sigb smt smb drill spt ssb spb ssb+1 pg6 pg5 # PRP MILLING_ORIGIN 'MILLING 0 0.0 0' 0 0 PRP DRILL_ORIGIN '' 0 0 PRP FIXED_COMPONENT_LOCATION 'M3,m1' 1 .... # #Net attribute names # #@0 .critical_net #@1 .diff_pair #@2 .net_type #@3 .electrical_class #@4 .dpair_gap #@5 .eclass_rise_time #@6 .eclass_max_stub_length # # #Net attribute text strings # #&0 DEFAULT #&1 clocks #&2 EC_PUA #&3 local ... # NET 0 NET /D_CL_TX_CLK ;0,2=1,3=2,5=1.500000;ID=1030 SNT TOP T 16 0 FID C 2 33 FID C 10 33 FID C 13 30 ... # PKG 1 PKG *PDXC-L10/HX-L127W51T97 0.1 -0.25 -0.145 0.25 0.145 RC -0.25 -0.1 0.5 0.2 PIN 1 T -0.2 -0.1105 0 E S ID=1034 RC -0.2125 -0.145 0.025 0.069 PIN 3 T -0.1 -0.1105 0 E S ID=1038 RC -0.1125 -0.145 0.025 0.069 PIN 5 T 0 -0.1105 0 E S ID=1041 RC -0.0125 -0.145 0.025 0.069 PIN 7 T 0.1 -0.1105 0 E S ID=1044 RC 0.0875 -0.145 0.025 0.069 PIN 9 T 0.2 -0.1105 0 E S ID=1049 RC 0.1875 -0.145 0.025 0.069 PIN 2 T -0.2 0.1105 0 E S ID=1053 RC -0.2125 0.076 0.025 0.069 PIN 4 T -0.1 0.1105 0 E S ID=1054 RC -0.1125 0.076 0.025 0.069 PIN 6 T 0 0.1105 0 E S ID=1059
RC -0.0125 0.076 0.025 0.069 PIN 8 T 0.1 0.1105 0 E S ID=1073 RC 0.0875 0.076 0.025 0.069 PIN 10 T 0.2 0.1105 0 E S ID=1075 RC 0.1875 0.076 0.025 0.069 # # PKG 2 PKG *MBCY-T2/XC-L80W80T115 0.1377953 -0.1574803 -0.1574803 0.1574803 0.1574803 CR 0 0 0.1574803 PIN P T 0.0688976 0 0 E T CR 0.0688976 0 0.011811 PIN N T -0.0688976 0 0 E T CR -0.0688976 0 0.011811 # FGR 1907 FGR TEXT PRP string '030' FID C 14 11018 FID C 14 11018
The file contains these types of records:
| HDR -File Header Record. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 111 | |-------------------------------------------------------------------------------------------------------------------------------|-------| | LYR -Layer Names Record. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 112 | | PRP -Property Record. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 112 | | @and &-NetAttribute Lookup Table Records. . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 112 | | NET -Electrical Net Record . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 114 | | SNT- Subnet Record . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 115 | | FID -Feature ID Record . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 116 | | PKG -Package Record. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 116 | | PIN -Pin Record . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 117 | | FGR -Feature Group Record . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 118 | | RC, CR, SQ, CT, OB, OS, OC, OE, CE -Outline Records. . . . . . . . . . . . . . . . . . . . . | 118 |
HDR - File Header Record
This record contains the name of the EDA system that was the source of the data. HDR <source>
| HDR Parameter | Explanation | |-----------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | source | A description of the EDA system from which the product model originated. For example: • Mentor Boardstation neutral file • Mentor Boardstation database • Cadence Allegro extract file • Zuken Redac CADIF file • Mentor PADS |
LYR - Layer Names Record
This record contains the names of the layers that are referenced in FID records.
See 'FID - Feature ID Record' on page 116.
LYR <name1>.... <namen>
| LYR Parameter | Explanation | |-------------------|--------------------------------------------------------| | name1, name2, ... | A legal layer name listed in the product model matrix. |
PRP - Property Record
A property is a value associated with EDA entities-board, net, package, feature-that specifies some of their characteristics.
PRP <property_name> '<property_value>' n1 n2 ...
| PRP Parameter | Explanation | |-----------------|-----------------------------------------------------------------------------| | property_name | Name of the property. The property name defines how to interpret the value. | | property_value | String of the property (between single quotes). | | n1,n2,... | Floating numbers to be kept in the property. |
@ and & - Net Attribute Lookup Table Records
This section of the file contains a table of net attribute names and a table of all net attribute values that are strings.
-
Net attribute names - Each record contains an at sign (@), an index, and an attribute name. For example, @0 .critical_net.
-
Net attribute text strings - Each record contains an ampersand (&), an index, and a text string that can be used as the value of an attribute of type TEXT. For example, &3 local.
System attributes that can be placed in this table are listed with Entity = Net in the attribute description. See 'System Attributes' on page 215
The lookup table must be placed before the first NET record in the file.
The NET records and PKG records in the file can assign net attributes by referencing the index of a net attribute and, for attributes of type TEXT, the index of the text string that is the value assigned to the attribute.
Note
- For backward compatibility, net attributes can be preceded by the number sign (#).
This is an example of a net attribute lookup table, and a NET record that assigns attributes.
#Net attribute names # @0 .critical_net @1 .diff_pair @2 .net_type @3 .electrical_class @4 .dpair_gap @5 .eclass_rise_time @6 .eclass_max_stub_length # #Net attribute text strings # &0 DEFAULT &1 clocks &2 EC_PUA &3 local ... # NET 0 NET /D_CL_TX_CLK ;0,2=1,3=2,5=1.500000;ID=1030
The NET record in the example should be interpreted as assigning these attributes to a net named /D_CL_TX_CLK:
| Assignment in the NET Record | Line in the Table of Attribute Names | Attribute Type | Line in the Table of Attribute Text Strings | Result | |--------------------------------|----------------------------------------|------------------|-----------------------------------------------|----------------------| | 0 | @0 .critical_net | BOOLEAN | - | .critical_net = TRUE | | 2=1 | @2 .net_type | TEXT | &1 clocks | .net_type = clocks |
| Assignment in the NET Record | Line in the Table of Attribute Names | Attribute Type | Line in the Table of Attribute Text Strings | Result | |--------------------------------|----------------------------------------|------------------|-----------------------------------------------|----------------------------| | 3=2 | @3 .electrical_class | TEXT | &2 EC_PUA | .electrical_class = EC_PUA | | 5=1.500000 | @5 .eclass_rise_time | FLOAT | - | .eclass_rise_time = 1.5 |
NET - Electrical Net Record
This record contains a start record of an electrical net. Each net consists of one NET line and 0 or more SNT records.
NET <net_name>; <attributes>;ID=<id> where:
| NET Parameter | Explanation | |-----------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | net_name | The same net_name found in the netlist file with which the following records are associated. Net names are for reference only. Every NET record is considered a different electrical net, and should be electrically isolated from all other NET records. Ideally, the <net_name> should be unique across all NET records. <net_name> may contain only printable ASCII characters, excluding the blank space and the semi-colon (;) character. When a feature does not have a net defined it is assigned to NET $NONE$. All un-assigned outer layer pads are defined as NET $NONE$. With more than one $NONE$ net, each is disconnected from the other. Any two points of a $NONE$ net can be connected or disconnected, depending on the design. | | attributes | A comma separated list of attribute assignments. The attribute is indicated by its index in the attribute name lookup table. • BOOLEAN -nindicating that attribute n is set. • OPTION -n=mindicating that attribute n has value m. • INTEGER -n=i indicating that attribute n has value i. • FLOAT -n=f indicating that attribute n has value f. • TEXT -n=s indicating that attribute n has the value associated with index s in the attribute text string lookup table. See '@ and &-Net Attribute Lookup Table Records' on page 112. | | ID=<id> | Assigns a unique identifier to the net. See 'Unique ID' on page 30. |
SNT- Subnet Record
This record defines a portion of a net. The portion can be one of these types of subnet:
- Toeprint - A connection of a component pin to the board.
- Via - A connectivity padstack between layers.
- Trace - A collection of lines or arcs leading from point to point.
- Plane - A surface used for connectivity purposes.
Each subnet record is followed by zero or more FID records mapped to the board features that are part of this subnet.
Structure for toeprint: SNT TOP <side> <comp_num> <toep_num>
| SNT TOP Field | Explanation | |-----------------|----------------------------------------------------------------------------------------------------------------------------| | TOP | Indicates that the subnet is a toeprint. | | side | T -Top side of the product model. B -Bottom side of the product model. | | comp_num | An index number (0...n-1) corresponding to the component record in the file comp_+top/components or comp+_bot/components | | toep_num | An index number (0...n-1) corresponding to a toeprint record of the referenced component. |
Structure for via: SNT VIA
| SNT VIA Field | Explanation | |-----------------|-------------------------------------| | VIA | Indicates that the subnet is a via. |
Structure for trace: SNT TRC
| SNT TRC Field | Explanation | |-----------------|---------------------------------------| | TRC | Indicates that the subnet is a trace. |
Structure for plane: SNT PLN <fill_type> <cutout_type> <fill_size>
| SNT PLN Field | Explanation | |-----------------|---------------------------------------| | PLN | Indicates that the subnet is a plane. | | fill_type | S -Solid. O -Outline. |
| SNT PLN Field | Explanation | |-----------------|-----------------------------------------------------------------------| | cutout_type | C -Circle. R -Rect. O -Octagon. E -Exact. | | fill_size | Size in inches or mmof fill brush. (For solid fill, use the value 0.) |
FID - Feature ID Record
This record contains a link to the feature file of layer number <lyr_num>. The record is used to connect subnets and feature groups to the board features that are part of them.
Structure: FID <type> <lyr_num> <f_num>
| FID Parameter | Explanation | |-----------------|-------------------------------------------------------------------------------------------------| | type | C -Copper. L -Laminate. H -Hole. | | lyr_num | A layer number (0 ... n-1) corresponding to the names of layers in the LYR record | | f_num | A feature number (0 ... n-1) corresponding to the feature record sequence in the features file. |
This is an example of the f_num sequence in a feature file:
# #Layer features # P 4.057087 4.5 6 P 0 0;1=6,3=0 #f_num = 0 P 4.057087 4.57874 6 P 0 0;1=6,3=0 #f_num = 1 P 4.057087 3.633858 6 P 0 0;1=6,3=0 #f_num = 2 P 4.057087 3.712598 6 P 0 0;1=6,3=0 #f_num = 3
PKG - Package Record
This record contains a definition of a package that is the generic shape of a component. Each component refers to a package.
Each PKG line must be followed immediately by one or more outline records, 0 or more property (PRP) records, and 0 or more pin records. See 'RC, CR, SQ, CT, OB, OS, OC, OE, CE - Outline Records' on page 118.
The order in which the PKG records occur is used by the CMP record (pkg_ref) of the component file to determine the desired package. The order is referenced starting from 0 and up. See 'CMP - Component Record' on page 157.
ODB++ requires closed geometries. That is, polygons must be closed and not intersect.
Structure: PKG <name> <pitch> <xmin> <ymin> <xmax> <ymax>; <attributes>;ID=<id>
| PKG Parameter | Explanation | |------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | name | Name of the package as defined in the EDA system | | pitch | Distance between center of closest pins, in inches or mm, based on the current unit of measure | | xmin, ymin, xmax, ymax | Bounding box of package, relating to package datum | | attributes | A comma separated list of attribute assignments. The attribute is indicated by its index in the attribute name lookup table. • BOOLEAN -nindicating that attribute n is set. • OPTION -n=mindicating that attribute n has value m. • INTEGER -n=i indicating that attribute n has value i. • FLOAT -n=f indicating that attribute n has value f. • TEXT -n=s indicating that attribute n has the value associated with index s in the attribute text string lookup table. See '@ and &-Net Attribute Lookup Table Records' on page 112. | | ID=<id> | Assigns a unique identifier the package. See 'Unique ID' on page 30. |
PIN - Pin Record
This record contains a definition of a pin that belongs to a package.
Each Pin record is followed by at least one outline record. See 'RC, CR, SQ, CT, OB, OS, OC, OE, CE - Outline Records' on page 118.
By default, pin #1 is determined by the first PIN record in the package. If the integer attribute .polarity_marker is assigned for the package, then that value overrides the default behavior by assigning pin #1 to the occurrence of the PIN record indicated by that integer.
Structure: PIN <name> <type> <xc> <yc> <fhs> <etype> <mtype> ID=<id>, where:
| PIN Parameter | Explanation | |-----------------|-----------------------------------------------| | name | Name of the pin as defined in the EDA system. |
| PIN Parameter | Explanation | |-----------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | type | T -Through-hole (top to bottom). B -Blind (top to inner or inner to bottom). S -Surface (top to top or bottom to bottom). | | xc, yc | Center of pin, relating to package datum. | | fhs | Finished hole size (currently not used-should be 0). | | etype | Pin electrical type: E -Electrical. M -Non-electrical (mechanical). U -Undefined (default). | | mtype | Pin mount type: S -SMT D -Recommended SMT pad (where the pin size is the recommended pad size and not the pin size). T -Through-hole. R -Through-hole where the pin size is the recommended hole size and not the pin size. P -Pressfit. N -Non-board, pins without contact area with the board. Used in components with lead forms of types: solder lug, high cable, or quick connect. H -Hole, for physical holes that appear without the physical pin U -Undefined (default). | | ID=<id> | Assigns a unique identifier to the pin. See 'Unique ID' on page 30. |
FGR - Feature Group Record
This record contains the definition of a group of related features-for example, the strokes of a text record. Each FGR line is followed by zero or more FID records mapped to the board features that are part of this subnet.
Structure: FGR <type>, where <type> is the string TEXT-the only value allowed.
RC, CR, SQ, CT, OB, OS, OC, OE, CE - Outline Records
Outline records must follow a PKG or PIN record. They describe the shape of the package or pin.
A PKG record must have an outline record as the immediate next entry (an outline record can be more than one line). A PIN record does require an outline record but not immediately after.
A shape can consist of a simple shape (rectangle, circle, square) or a complex contour.
- RC - Rectangle record.
RC <lower_left_x> <lower_left_y> <width> <height>
- CR - Circle record.
CR <xc> <yc> <radius>
- SQ - Square record.
- CT, OB ... CE - Contour record.
SQ <xc> <yc> <half side>
The structure of a contour record is the same as a surface feature in the features file and is restricted by the same limitations. A contour consists of one or more polygons.
- o Self-intersecting polygons (SIPs) are not allowed.
- o The polygons must form a closed shape, as described:
A polygon starts with an OB command, contains OS (segment) or OC (arc) commands, and ends with an OE command.
OB <start_x> <start_y> I/H (I=island, H=hole) OS <end_x> <end_y> OC <end_x> <end_y> <center_x> <center_y> <cw> (cw = y or n) OE
- o Holes must be graphically contained inside island polygons.
- o The arcs must be consistent (the start, end, and center point must construct a legal arc).
eda/shorts (Electrical Intention Short Net)
This file contains information that is read from the EDA system directly.
| shorts (Electrical Intention Short Net) | shorts (Electrical Intention Short Net) | |-------------------------------------------|---------------------------------------------------| | Type | Line Record Text | | Compression | Yes | | Path | <product_model_name>/steps/<step_name>/eda/shorts | | UNITS | The UNITS directive is required. |
The file contains a list of features that are known to create intentional net shorts within the product model.
<!-- formula-not-decoded -->If more than two nets are short together, each instance of the resulting net shorts must be defined separately. If the copper feature that caused the shorts has a net name, the number of shorts that must be defined is reduced.
Example of a shorts file:
# UNITS=MM LYR sst sigt sig2 sig3 sig4 sig7 sig8 sig9 sigb smt smb drill spt ssb spb pg6 pg5 # SRT 1 SRT 1 7;ID=20 FID C 4 2 FID C 4 3 # SRT 2 SRT 2 7;ID=21 FID C 4 4 FID C 4 3 # SRT 3 SRT 3 7;ID=22 FID C 4 6 FID C 4 3 # SRT 4 SRT 4 7;ID=23 FID C 4 8 FID C 4 3 # SRT 5 SRT 5 7;ID=24 FID C 4 10 FID C 4 3 # SRT 6 SRT 6 7;ID=25 FID C 4 12
FID C 4 3
The file contains records of type LYR, FID, and SRT.
| Record Type | Description | |--------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | LYR -Layer Names in the Shorts File | This record contains the names of the layers that are referenced in FID records. | | FID-Feature ID Record in the Shorts File | This record contains a link to the feature file of layer number <lyr_num>. The record is used to connect subnets and feature groups to the board features that are part of them. | | SRT -Electrical Intention Short Net Record | This record is a start record for defining an intentional short. |
LYR - Layer Names in the Shorts File
This record contains the names of the layers that are referenced in FID records.
This is the format of the LYR record:
LYR <name1>.... <namen>
| LYR Parameter | Explanation | |-------------------|--------------------------------------------------------| | name1, name2, ... | A legal layer name listed in the product model matrix. |
See 'FID-Feature ID Record in the Shorts File' on page 122.
FID-Feature ID Record in the Shorts File
This record contains a link to the feature file of layer number <lyr_num>. The record is used to connect subnets and feature groups to the board features that are part of them.
This is the format of the FID record:
FID <type> <lyr_num> <f_num>
| FID Parameter | Explanation | |-----------------|-------------------------------------------------------------------------------------------------| | type | FID records in a shorts file can only be of type C or H. C -Copper. H -Hole. | | lyr_num | A layer number (0 ... n-1) corresponding to the names of layers in the LYR record | | f_num | A feature number (0 ... n-1) corresponding to the feature record sequence in the features file. |
This is an example of the f_num sequence in a feature file:
# #Layer features # P 4.057087 4.5 6 P 0 0;1=6,3=0 #f_num = 0 P 4.057087 4.57874 6 P 0 0;1=6,3=0 #f_num = 1 P 4.057087 3.633858 6 P 0 0;1=6,3=0 #f_num = 2 P 4.057087 3.712598 6 P 0 0;1=6,3=0 #f_num = 3
SRT - Electrical Intention Short Net Record
This record is a start record for defining an intentional short.
Each short definition contains at least two FID records, or one from each net name. The need for multiple FID records that go through layers would result from a via or through hole location participating in a short.
If the same nets are shorted together in multiple locations for a single product model, then the multiple short locations should be recorded separately and each would contain its own FID related records. This also means that there might be more than one SRT record containing the same NET net_name IDs.
If more than two nets are short together, each instance of the resulting net shorts must be defined separately. For example, if there are three nets, net1, net2 and net3 that are shorted together, then the short of net1 to net2, net2 to net3 and net3 to net1 will need to be listed in the file.
This is the format of the SRT record:
SRT <net_name1_uid> <net_name2_uid> ID=<id>
| SRT Parameter | Explanation | |-----------------|---------------------------------------------------------------------------------------------------------------------------------------------| | net_name1_uid | The ID from the NET record from within the eda/data file referencing the first net shorted together. | | net_name2_uid | The ID from the NET record from within the eda/data file referencing the second net shorted together. | | ID=<id> | A fixed string to indicate the following value is a unique ID, and its numerical value within the legal range of 0 - 4294967295 (optional). |
Example of Multiple Nets Shorted with a Copper Feature With a Net Name
This is an example of multiple nets shorted together, where the copper feature is provided a net name.
<!-- image -->In this example, copper feature 13, which causes the short, has a net name with UID = 7. Six SRT sections are required. Each one describes a short between net 7 and one of the other six nets.Each SRT section has two FID lines. Each one identifies a feature involved in the short.
# SRT 1 SRT 1 7;ID=20 FID C 4 2 FID C 4 13 # SRT 2 SRT 2 7;ID=21 FID C 4 4 FID C 4 13 # SRT 3 SRT 3 7;ID=22 FID C 4 6 FID C 4 13 # SRT 4 SRT 4 7;ID=23 FID C 4 8 FID C 4 13 # SRT 5 SRT 5 7;ID=24 FID C 4 10 FID C 4 13 # SRT 6 SRT 6 7;ID=25 FID C 4 12 FID C 4 13
Example of Multiple Nets Shorted With a Copper Feature Without a Net Name
This is an example of multiple nets shorted together, where the copper feature is not provided a net name:
<!-- image -->In this example, copper feature 13, which causes the short, does not have a net name. Fifteen SRT sections are required-one for each possible pair of the six nets that are shorted together by copper feature 13:
1-2, 1-3, 1-4, 1-5, 1-6
2-3, 2-4, 2-5, 2-6
3-4, 3-5, 3-6
4-5, 4-6
5-6
Each SRT section has three FID lines to define the three features involved in the short.
# SRT 1 SRT 1 2;ID=20 FID C 4 2 FID C 4 13 FID C 4 4 # SRT 2 SRT 1 3;ID=21 FID C 4 2 FID C 4 13 FID C 4 6 # SRT 3 SRT 1 4;ID=22 FID C 4 2 FID C 4 13 FID C 4 8 # SRT 4 SRT 1 5;ID=23 FID C 4 2 FID C 4 13 FID C 4 10 # SRT 5 SRT 1 6;ID=24 FID C 4 2 FID C 4 13 FID C 4 12 # SRT 6 SRT 2 3;ID=25 FID C 4 4 FID C 4 13 FID C 4 6 # SRT 7 SRT 2 4;ID=26 FID C 4 4 FID C 4 13 FID C 4 8 # SRT 8 SRT 2 5;ID=27 FID C 4 4 FID C 4 13 FID C 4 10 # SRT 9 SRT 2 6;ID=28 FID C 4 4 FID C 4 13 FID C 4 12 ...
eda/hdi_netlist (HDI Netlist)
A netlist defining wire bond connection is defined in this file.
| hdi_netlist | hdi_netlist | |---------------|-----------------| | Type | Structured Text |
| hdi_netlist | hdi_netlist | |---------------|--------------------------------------------------------| | Compression | No | | Path | <product_model_name>/steps/<step_name>/eda/hdi_netlist | | UNITS | The UNITS directive is required. |
This netlist defines connections between pins of source and destination components for nets including wire bonds.
└─── <product_model_name> ├─── ... ├─── steps │ └─── <step_name> │ └─── eda │ └─── hdi_netlist └─── ...
Examples are given for each array structure.
The hdi_netlist file contains these array structures: HDI_NETLIST_DATABASE, HDI_PACKAGE, HDI_NET_POINT, HDI_NET_BRIDGE
HDI_NETLIST_DATABASE Array Structure
The file contains a single HDI_NETLIST_DATABASE record containing common information.
| Parameter | Explanation | |-------------|----------------------------------------------------------------------------| | units | Units of coordinates in the file. (INCH / MM) | | source | Application used to create ODB++, or input source if created by Valor NPI. | | version | Netlist version. |
Example of the HDI_NETLIST_DATABASE section:
HDI_NETLIST_DATABASE { units=MM source=ExpeditionPCB version=2.0 }
HDI_PACKAGE array structure
The file contains a HDI_PACKAGE records for each component involved in the netlist. These components are specified in the die parameter or the dest_comp parameter of the HDI_NET_POINT records.
| Parameter | Explanation | |-------------|------------------------------------------------------------------------------------------------------------| | name | Name of a component used in HDI_NET_POINT records. | | ref_des | Reference designator of the corresponding component in the design (usually the same as the value in name). | | type | DIE or SRC for a source component; BGA or DST for a destination component. |
Example of the HDI_PACKAGE section:
HDI_PACKAGE { name=U4 ref_des=U4 type=DIE }
HDI_NET_POINT Array Structure
The file contains multiple HDI_NET_POINT records for all pins of source and destination components connected by wire bonds. The records contains the same fields for both source and destinations but some fields are empty depending on the net point and connection type..
| Parameter | Explanation | Source and Destination | |-------------|--------------------------------------------------------------------------------------------------------------------------------|-----------------------------------| | net | Name of die bump net (should be the same as the value of .net attribute of corresponding pad in wire bond layer). | pin to pin pin to net pin to gate | | x, y | Die bump coordinates (the same-within a certain tolerance-as the coordinates of the corresponding pad in the wire bond layer). | pin to pin pin to net pin to gate | | sym | Similar to the symbol name of corresponding pad in wire bond layer. | pin to pin pin to net pin to gate | | die | Name of the source component. An HDI_PACKAGE record must exist for the component. | pin to pin pin to net pin to gate | | bump | Name of the source component pin. | pin to pin pin to net pin to gate |
| Parameter | Explanation | Source and Destination | |-------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------| | gate | Gate name. This is used as a key to find the corresponding destination gate record. See the examples. ODB++ does not contain a corresponding entity, feature, or attribute. | pin to gate | | dest_net | Name of the destination net. | pin to net destination net | | dest_comp | Name of the destination component. An HDI_PACKAGE record must exist for the component. | pin to pin pin to net destination net destination gate | | dest_pin | Name of destination component pin. | pin to pin destination net destination gate | | dest_gate | Name of the destination gate. The gate parameter in a pin to gate record points to a gate specified in the dest_gate parameter of a destination gate record. See the examples. | destination gate |
Example of the HDI_NET_POINT section for a source pin connected to a destination pin
HDI_NET_POINT { net=X_X_ATB1TL x=-6.430395 y=4.160125 sym=rect60x49 die=U1 bump=35 gate= dest_net= dest_comp=B1 dest_pin=B4 dest_gate= }
Example of the HDI_NET_POINT section for a source pin connected to a destination net
A record specifying a destination net instead of a destination pin is used for a net containing multiple pins of the same destination component (typically power / ground nets).
Each pin of the destination component connected to such a net should be represented by separate HDI_NET_POINT record for a destination net.
HDI_NET_POINT { net=X_X_ATB1TL x=-6.430395 y=4.160125 sym=rect60x49 die=U1 bump=35 gate= dest_net=X_X_ATB1TL dest_comp= dest_pin= dest_gate= }
Example of the HDI_NET_POINT section for a destination net
Multiple records with the same dest_net are allowed. Typically, the destination net and source net are the same, but different nets are also supported.
HDI_NET_POINT { net= x= y= sym= die= bump= gate= dest_net=X_X_ATB1TL dest_comp=B1 dest_pin=B4 dest_gate= }
Example of the HDI_NET_POINT section for a source pin connected to a destination gate
HDI_NET_POINT { net=X_X_ATB1TL x=-6.430395 y=4.160125 sym=rect60x49 die=U1 bump=35 gate=GATE23 dest_net= dest_comp= dest_pin= dest_gate= }
Example of the HDI_NET_POINT section for a destination gate
Multiple records with the same dest_gate are allowed. Source and destination net should be the same in the case of a connection to a gate.
HDI_NET_POINT { net= x= y= sym= die= bump= gate= dest_net= dest_comp=B1 dest_pin=B4 dest_gate=GATE23 }
HDI_NET_BRIDGE array structure
The netlist file can contain an optional section for a direct wire bond connection in the same copper layer. No component pins are involved in such a connection.
| Parameter | Explanation | |-------------|---------------------------------------------------------------------------------------------------------------------------------------------------| | net | Name of the net with a direct wire bond connection. | | x1, y1 | Coordinates of one of the connected points. The copper layer should contain pads with similar coordinates or lines / arcs with similar endpoints. | | x2, y2 | Coordinates of one of the connected points. The copper layer should contain pads with similar coordinates or lines / arcs with similar endpoints. |
Example of an HDI_NET_BRIDGE section
HDI_NET_BRIDGE { net=VCCEL_L 1=0.37 y1=0.54 x2=0.385 y2=0.544 }
<step_name>/impedance.xml (Impedance)
The optional impedance file contains data relevant to the calculation of copper impedance for the step.
| StackupFile (Stackup) | StackupFile (Stackup) | |-------------------------|-----------------------------------------------------| | Type | XML | | Compression | None | | Path | <product_model_name>/steps/<step_name>impedance.xml |
└─── <product_model_name> ├─── ... ├─── steps │ └─── <step_name> │ └─── impedance.xml └─── ...
Structure of the Impedance File. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
133
Structure of the Impedance File
The Impedances element contains instances of the Descriptor section.
Figure 4-1. Impedance File
<!-- image -->Descriptor
A list of impedance requirements for the trace features that bear the id attribute and reside in the layer having a specific name.
Child elements:
- RequiredImpedance - The required impedance values (0-1)
- OriginalTraceWidth - The original trace width for the required impedance (0-1)
- OriginalSpacing - The original spacing between copper for the required impedance (0-1)
- RefPlane - The list of layers that represent the reference planes in impedance calculation (0-2)
Example:
<Impedances Version="8.1" MaxImpIdValUsed="3"> <Descriptor Id="1" TraceLayerName="t10"> <RequiredImpedance ValOhms="50" PlusVal="5" MinusVal="5" ValPercent="true"/> <OriginalTraceWidth Val="0.5" Units="MIL"/> <OriginalSpacing Val="1" Units="MICRON"/> <RefPlane Val="g09"/> </Descriptor> </Impedances>
The schema is described in 'Impedances' on page 512.
<step_name>/layers
Layers express physical board layers, and also mask layers, NC drill and rout layers, and miscellaneous drawings.
See 'Layer Entities' on page 151 for a discussion of the files relating to the layers.
<step_name>/netlists
These files are related to the netlists entity.
| cadnet/netlist (cadnet) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 135 | |-------------------------------------------------------------------------------------------------------------------------------------|-------| | refnet/netlist (Reference). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 141 |
cadnet/netlist (cadnet)
This file represents a netlist as it was read from an external CAD system. A netlist is a collection of nets, each one referencing a group of points.
| cadnet/netlist (cadnet) | cadnet/netlist (cadnet) | |---------------------------|----------------------------------------------------------------| | Type | Line Record Text | | Compression | None | | Path | <product_model_name>/steps/<step_name>/netlists/cadnet/netlist | | UNITS | The UNITS directive is required. |
When a feature does not have a net defined, it is assigned to NET $NONE$. All non-assigned features are defined as NET $NONE$. See 'NET - Electrical Net Record' on page 114.
└─── <product_model_name> ├─── ... ├─── steps │ └─── <step_name> │ └─── netlists │ └─── cadnet │ └─── netlist └─── ...
The files consists of a header line, a list of nets, and a list of net points.
Header Line
The first line of the file is the header line. It has this syntax:
H optimize <y|n> [staggered <y|n>]
| Field | Explanation | |----------|----------------------------------------------------------------------------------------------------------------------------------------| | optimize | y -Netlist was optimized for bare board testing. n -Netlist was not optimized. For CAD netlists, the net will always be non-optimized. |
| Field | Explanation | |----------------------|-----------------------------------------------------------------------------------------------------------| | staggered (optional) | y -Netlist points have been staggered for testing. n -Netlist points have not been staggered for testing. |
List of Nets
The net section of the file contains lines with this syntax:
$<serial_num> <net_name>
| Field | Explanation | |------------|-----------------------------------------------------------------------------------------------------------------------------| | serial_num | The net serial number, starting with 0. | | net_name | A unique name representing the name or a net. A typical practice is to use the original net name used in the design system. |
Net names are for reference only. Every <serial_num> net is considered a different electrical net, and should be electrically isolated from all different <serial_num> nets. Ideally, every <serial_num> net should have a different <net_name>. There is no limit on the length of a <net_name>, but <net_name> may contain only printable ASCII characters, excluding the blank space and the semi-colon (;) character.
List of Net Points
The net point section of the file lists the net points. It contains lines of this syntax:
<net_num> <radius> <x> <y> <side> [<w> <h>] <epoint> <exp> [<"c">] ["staggered" <sx> <sy> <sr>] [<"v">] [<"f">] [<"t">] [<"m">] [<"x">] [<"e">] ["by="<by>] ["arsize_top="<arsize_top>] ["arsize_bot="<arsize_bot>] ["is_shrink="< is_shrink>] ["ld="<ld>]
In the syntax line, these conventions are used:
- < > - Angled brackets represent a single field or value.
- [ ] - Square brackets represent optional fields.
- " " - Quotation marks represent literal strings.
Positional parameters must be placed in the correct order on the line. Keyword parameters can be placed at any position on the line, after the positional parameters.
Fields are space delimited. There should be no spaces before or after an equals sign (=).
| Field | Explanation | |---------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | net_num | Index of the net as defined in the list of nets. For example, if the list of nets includes this line: $0 MYNET Then these net point lines refer to the net MYNETbecause the first value in these lines is a zero: 0 0.002 4.96 -2.64 T e e staggered 0 0 0 0 0.002 4.94 -2.4775 T e e staggered 0 0 0 0 0.002 4.945 -2.575 B e e staggered 0 0 0 A net index value of -1 can be used to represent tooling holes. When a feature is found with no reference to a net index, the net name $NONE$ should be assigned to the feature. | | radius | Drill radius (inches or mm). For SMD pads: • In cadnet -0.002 (independent of units) • In reference net -0inch. | | x, y | Point coordinates (inches or mm). |
| Field | Explanation | |---------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | side | The side from which the net point is accessible. • T (top) -Indicates net points accessible from the TOP side of the ODB++ product model. This includes net points placed on inner layers, but accessible from the TOP side through the use of a layer profile hole (cavity). The layer on which a net point resides is defined by the ld parameter. If the ld field is missing, the TOP layer UID is assumed. • D (down) -Indicates net points accessible from the BOTTOM side of the ODB++ product model. This includes net points placed on inner layers, but accessible from the BOTTOM side through the use of a profile hole (cavity). The layer on which a net point resides is defined by the ld parameter. If the ld field is missing, the BOTTOM layer UID is assumed. • B (both) -Indicates net points accessible from TOP and BOTTOM sides of the ODB++ product model. This includes net points placed on inner layers, but accessible from the TOP side and the BOTTOM side through the use of a profile hole (cavity). In this case the net points are accessible from both sides of the product model by means of plated through holes, and non_plated and via holes are excluded. The layers on which a net point resides is defined by the ld value of the drill/rout layer defining the hole location. The matrix information for the associated drill/rout layer provides the layer accessibility from the TOP and BOTTOM side. If the ld field is missing or does not represent a drill/rout layer, the TOP and BOTTOM layer UIDs are used to define the layer on which to place the net point. • I (inner) -Indicates net points that are not accessible from the TOP or BOTTOMside of the ODB++ product model. These are net points resulting from completely buried inner layer surface connections, not exposed by a profile hole (cavity). In this case the net points exclude all internal plated, non_plated and via holes. The layer on which the net point resides is based on the ld parameter. Previous format definitions included following the letter I by an integer representing the layer position within the matrix. This use is now obsolete. | | w, h | Width and height of non-drilled pads (only when radius = 0). | | epoint | e -Net end point. m-Net mid point. | | exp | e -Solder mask exposed point. c -Solder mask covered point. p -Solder mask covered point on top side of product model. s -Solder mask covered point on bottom side of product model. |
| Field | Explanation | |---------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | c | Comment point flag used to mark net points that are irrelevant to the product model. For example, these points can be ignored during the net comparison process. | | sx, sy | Coordinates of staggered point (where probe location is other than net point location). | | sr | Represents the radius of a probe to be used at this location. | | v | Via point. | | f | Fiducial point. | | t | Test point. | | m | Present when a netlist point is designated as a test point by assigning it the .critical_tp attribute. Normally this is applied to mid-points that need to be tested. If both .non_tp and .critical_tp are assigned to the same point, .critical_tp takes precedence and the mid point is tested. In case of a drilled pad, the attribute must be added to the drill hole. | | x | This indicates that there are extension records in the netlist file. Extension records contain the e keyword and have the same location. A net point description for an extended point does not have to be grouped together in the netlist file. 0 0.00675 0.8 3.3 B m e v x by=b 0 0 2.5 3.214393 T 0.04242 0.04242 e s staggered 0 0.01325 0 e by=c ld=111 | | e | This indicates that this is an extension record for a line containing the x keyword. A net point description for an extended point does not have to be grouped together in the netlist file. 0 0.00675 0.8 3.3 B m e v x by=b 0 0 2.5 3.214393 T 0.04242 0.04242 e s staggered 0 0.01325 0 e by=c ld=111 | | by | Defines how a test is executed: (c s b a n) c -Test from component side. s -Test from solder side. b -Test from both sides. a -Test from any one side. n -Side not defined (default). If <by> value not defined, n is assumed. |
| Field | Explanation | |------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | arsize_top | The annular ring size for top represents the minimum width of exposed copper (from solder mask) around a drill hole on the top outer layer. If the hole does not go through the top layer, arsize_top should not be defined or should be set to 0. Example: 4 0.023622 0.726 0.3351969 B m e arsize_top=0.016378 arsize_bot=0.0161873 4 0.015748 0.7460787 0.5300787 B e e by=a arsize_top=0.011752 arsize_bot=0.0116406 4 0.011811 0.0358425 0.1450394 B m c arsize_top=0 arsize_bot=0 | | arsize_bot | The annular ring size for bottom represents the minimum width of exposed copper (from solder mask) around a drill hole on the bottom outer layer. If the hole does not go through the bottom layer, arsize_bot should not be defined or should be set to 0. Example: 4 0.023622 0.726 0.3351969 B m e arsize_top=0.016378 arsize_bot=0.0161873 4 0.015748 0.7460787 0.5300787 B e e by=a arsize_top=0.011752 arsize_bot=0.0116406 4 0.011811 0.0358425 0.1450394 B m c arsize_top=0 arsize_bot=0 | | is_shrink | Indicates that the radius field, which should contain the diameter of the drill, was shrunk to fit the solder mask opening or pad size. (y[es]/[no]) y -Point size was shrunk to fit solder mask opening. n -Point size is limited only by pad size. | | ld | Defines to which layer a net point belongs. The layer is defined by its unique ID. See 'Unique ID' on page 30. Optional for top and bottom side, and obligatory for inner points. |
Example of a cadnet netlist file
UNITS=MM H optimize n staggered n $0 &1N1096 $1 &1N1526 $2 &1N289 $3 &1N312 $4 &1N338 $5 &1N340 $6 $NONE$ ... # #Netlist points # 0 0.002 4.96 -2.64 T e e staggered 0 0 0 0 0.002 4.94 -2.4775 T e e staggered 0 0 0 0 0.002 4.945 -2.575 B e e staggered 0 0 0 1 0.002 4.31 -4.045 T e e staggered 0 0 0 1 0.002 4.27 -3.893 T e e staggered 0 0 0
refnet/netlist (Reference)
This file describes the reference netlist for the step. A reference netlist describes net connectivity as it should be, derived from actual connectivity of the board. This netlist file should be generated and used as the source netlist of choice.
| refnet/netlist (Reference) | refnet/netlist (Reference) | |------------------------------|----------------------------------------------------------------| | Type | Line Record Text | | Compression | None | | Path | <product_model_name>/steps/<step_name>/netlists/refnet/netlist | | UNITS | The UNITS directive is required. |
The format of the file is identical to that of 'cadnet/netlist (cadnet)' on page 135.
└─── <product_model_name> ├─── ... ├─── steps │ └─── <step_name> │ └─── netlists │ └─── refnet │ └─── netlist └─── ...
<step_name>/profile (Outline Shape of Step)
The step profile defines the outline shape of the step. It is required by many operations.
| profile (Outline Shape of Step) | profile (Outline Shape of Step) | |-----------------------------------|------------------------------------------------| | Type | Structured Text | | Compression | None | | Path | <product_model_name>/steps/<step_name>/profile | | UNITS | The UNITS directive is required. |
A profile is created using a single surface feature representing the outline of the step with optional internal holes (cutouts). There can be only one island, but any number of holes inside the island. Holes cannot touch the island boundary or one another.
└─── <product_model_name> ├─── ... ├─── steps │ └─── <step_name> │ └─── profile └─── ...
The profile file is a features file defining a single surface feature. Surface features are defined as described in '<layer_name>/features (Graphic Features)' on page 170.
Example of a Step Profile File
UNITS=MM ID=58 # #Num features # F 1 # #Layer features # S P 0 OB -49.9341975 -64.2563075 I OS -49.9341975 -0.5988325 OS -0.518735 -0.5988325 OS -0.518735 -64.2563075 OS -49.9341975 -64.2563075 OE OB -44.3237075 -43.97223 H OS -15.839685 -43.97223 OS -15.839685 -13.7619025 OS -44.3237075 -13.7619025 OS -44.3237075 -43.97223 OE SE
<step_name>/stephdr (Step Header)
This file contains data that is common to the whole step. This includes the step and repeat array for nested steps.
| stephdr (Step Header) | stephdr (Step Header) | |-------------------------|------------------------------------------------| | Type | Structured Text | | Compression | None | | Path | <product_model_name>/steps/<step_name>/stephdr | | UNITS | The UNITS directive is required. |
The graphic order of precedence for features is as defined in 'Geometric Entities' on page 39. When using step repetitive format content within stephdr (DX, DY, NX, NY), the referenced step begins at location (X, Y). Subsequent reference steps are first shifted the distance of DXNX number of times-to complete the first row of reference steps. The format then returns to the previous (X, Y) location, shifts the distance of DY (new Y location), and begins the NX repeat again, completing the next row. This is completed NY number of times. The sequence in which the reference steps are added determines order of precedence for each repeated step, as defined also in 'Geometric Entities' on page 39.
└─── <product_model_name> ├─── ... ├─── steps │ └─── <step_name> │ └─── stephdr └─── ...
The file consists of general fields, and an array of STEP-REPEAT records that exists only if there are nested steps.
These are the general fields:
| Field | Explanation | |----------|-------------------------------------------------------------------------------------------------------| | X_DATUM | X datum point (used for step and repeat). | | Y_DATUM | Y datum point (used for step and repeat). | | ID | A unique ID (optional). See 'Unique ID' on page 30. | | X_ORIGIN | X origin point. Defines the location of the x-zero point (0, 0) in relation to the feature positions. | | Y_ORIGIN | Y origin point. Defines the location of the y-zero point (0, 0) in relation to the feature positions. |
| Field | Explanation | |---------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | TOP_ACTIVE BOTTOM_ACTIVE RIGHT_ACTIVE LEFT_ACTIVE | Active area is the area allowed for step and repeat of substeps. It is used to define the border width on the panel edges that should be kept free for placement of coupons and targets. These fields are used only when the step is a panel or array that is meant to contain other steps. (optional) | | AFFECTING_BOM | The product model can contain several relevant BOMs. Only one BOMdescribes the current state of the product model. This field contains the integer 0 to represent that BOM. | | AFFECTING_BOM_CHANGED | When a product model is modified to use a different BOM, but the necessary update processes have not been run (for example, package geometries have not been updated to the new BOM) then this field contains the integer 1 . | | ONLINE_<online_type> | Obsolete parameters maintained for backward compatibility that may be any number of the DRC_* or NET_* parameters (Obsolete) |
These are the fields in the STEP-REPEAT array:
| Field | Explanation | |---------|--------------------------------------------------------------------------------------------------------------------------------------------------| | NAME | Name of the step to be included in the current step. It must be a valid step in the same product model, without nesting or circular referencing. | | X | Start X coordinate for placement of the datum point of the nested step. See the X_DATUM field among the general fields. | | Y | Start Y coordinate for placement of the datum point of the nested step. See the Y_DATUM field among the general fields. | | DX | Horizontal distance between datum points (when ANGLE = 0). | | DY | Vertical distance between datum points (whenANGLE= 0). | | NX | Number of repetitions horizontally. | | NY | Number of repetitions vertically. | | ANGLE | Rotation angle of the steps (see 'Angles' on page 34). |
| Field | Explanation | |---------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | FLIP | When set to YES , all layers in the step instance are mirrored and the layer order is reversed. This can be done only with steps that have a symmetrical buildup (both layer polarities and layer types should be symmetrical). | | MIRROR | YES for mirror (around x-axis), NO for no mirror. |
Example of the stephdr file
The file consists of general fields, and an array of STEP-REPEAT records that exists only if there are nested steps.
UNITS=INCH X_DATUM=0 Y_DATUM=0 ID=123456 STEP-REPEAT { NAME=1UP X=1.5 Y=1.6 DX=1.2 DY=1.2 NX=6 NY=6 ANGLE=0 FLIP=NO MIRROR=NO } TOP_ACTIVE=1 BOTTOM_ACTIVE=1 RIGHT_ACTIVE=1 LEFT_ACTIVE=1 AFFECTING_BOM= AFFECTING_BOM_CHANGED=0
<step_name>/zones (Matrix Broken Into Sections)
The zones file is optional. When the file exists, the content provides a cross-sectional view of areas within the profile of a step that are the same.
| zones (Matrix Broken into Sections) | zones (Matrix Broken into Sections) | |---------------------------------------|----------------------------------------------| | Type | Structured Text | | Compression | None | | Path | <product_model_name>/steps/<step_name>/zones |
| UNITS | The UNITS directive is required. | |---------|------------------------------------|
The file is comprised of multiple regions, or zones, that are defined by surfaces where the board layer materials, including the base layer types of SIGNAL, POWER_GROUND, MIXED, DIELECTRIC, SOLDER_MASK, SOLDER_PASTE, MASK and CONDUCTIVE_PASTE and the associated subtype for each, through the matrix, are identical. An air gap between layers does not require the creation of an additional zone.
└─── <product_model_name> ├─── ... ├─── steps │ └─── <step_name> │ └─── zones └─── ...
For each zone, the zones file contains information about the zone, a list of layers in the zone, properties of each of the layers (optional), and a surface feature that describes the outline, islands, and holes of the zone.
This graphic illustrates a cross section of a board and the layers for which zones are defined.
<!-- image -->This graphic illustrates the surfaces defined for the zones. Zone 1 has an island and a hole. Zone 2 has an island.
<!-- image -->A zones file has several types of records: ZONE (start record), LYR (layer record), PRP (properties record), S (surface defining zone area)
ZONE - Start Record
Start zone record: ZONE <name>;zone_UID
Defines the start of a zone by providing a name by which the zone will be referenced.
| ZONE Record Parameter | Explanation | |-------------------------|-----------------------------------------------------------------------------------| | name | The name of each zone must be unique and follow ODB++ standard entity guidelines. | | zone_UID | A unique ID for this zone. |
LYR - Layer Record
Layer record: LYR <layer_UIDs>
Lists the layers that belong to the zone.
| LYR Record Parameter | Explanation | |------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | layer_UIDs | The list of layer_UIDs to which the ZONE applies. This includes dielectric UIDs. These layer UIDs must be defined in the matrix. See 'matrix (Product Model Matrix)' on page 51. |
PRP - Properties Records
Properties Record: PRP <name> <value> <units> <layer_UIDs>
Optional. Defines properties of specific layers, such as the enlargement factor or the copper area.
| PRP Record Parameter | Explanation | |------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | name | One of these names: • enlarge_zone -The amount by which the zone will be enlarged. This would apply in situations where the coverlay intrudes into the rigid region of the board (known as a bikini coverlay). • copper_area -The copper area for a layer within the zone. This would typically be used with a single layer_UID. |
| PRP Record Parameter | Explanation | |------------------------|--------------------------------------------------------------------------------------------------------------------------------------| | value | The values appropriate to the specified name. • name = enlarge_zone -The enlargement amount. • name = copper_area -The copper area. | | units | Units follow unit of measurements ODB++ format guidelines. | | layer_UIDs | The list of layer_UIDs to which the property is assigned. The layer_UIDs must be among those listed in the LYR record for this zone. |
S - Surface Defining the Zone Area
The records following the LYR record, and possibly the optional PRP records, define a zone as a single surface feature representing the outline of the zone with its optional internal holes (cutouts). Each zone can be constructed using multiple islands with any number of holes inside each island.
The zones follow the rules that apply to the ODB++ contour definition. These specific rules apply:
- An island must completely surround its holes.
- Holes must not touch one another or intersect within the island.
- No islands defined by two different zones enforced on single layer can intersect, but an island from one zone can be tangent to an island of another zone on a single layer.
- No features other than a surface are legal in the zones file.
- A zone may not exist outside of the area defined by the board profile.
- In order for a zone to be defined within a zone, a hole must first be created in the encompassing island.
A surface is defined in a zones file with the same syntax used in a features file. See 'S Surface Records' on page 185.
Example of a zones file
UNITS=INCH ID=2411100 # # Zone 1 # ZONE area1;UID=2411111 LYR 23 45 78 97 PRP copper_area 2.23 INCH 23 PRP copper_area 5.53 INCH 45 PRP copper_area 6.23 INCH 78 PRP copper_area 2.73 INCH 97 S P 0;;ID=2452187 OB -2 -2 I OS -2 4 OS 4 4 OS 4 -2 OS -2 -2 OE OB -1 -1 H OS 3 -1 OS 3 3 OS -1 3 OS -1 -1 OE SE # # Zone 2 # ZONE area2;UID=2411112 LYR 45 75 PRP copper_area 1.23 INCH 45 PRP copper_area 3.53 INCH 75 S P 0;;ID=2503253 OB 2 1 I OS 2 -1 OS 0 -1 OS 0 1 OS 2 1 OE SE
Chapter 5 Layer Entities
Product model layers can contain graphics, properties and annotation. Layers represent physical board layers, NC drills and rout layers, miscellaneous drawings, and dielectric separators. The order in which layers are arranged is based on the content in the matrix. Layers of type DIELECTRIC can only contain information representing material attributes, such as thickness.
For information on the matrix, see 'matrix (Product Model Matrix)' on page 51.
| <layer_name>/attrlist (Layer Attribute List) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 152 | |---------------------------------------------------------------------------------------------------------------------------------|-------| | <layer_name>/components (Components) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 153 | | @and &-Component Attribute Lookup Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 155 | | CMP -Component Record. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 157 | | PRP -Component Property Record . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 157 | | TOP -Component Toeprint Record. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 158 | | BOMDescription Records . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 158 | | <layer_name>/dimensions (Dimensions) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 161 | | Global Parameters for Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 164 | | PARAMETERS Array Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 165 | | DIMENSION Array Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 166 | | PAPER Array Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 167 | | TEXT Array Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 168 | | <layer_name>/features (Graphic Features) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 170 | | UNITS -Measurement Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 172 | | ID -Unique ID (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 173 | | F -Number of Features (Optional). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 174 | | $ -Feature Symbol Names Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 174 | | @and &-Feature Attribute Lookup Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 174 | | L -Line Records. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 176 | | P -Pad Records . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 176 | | A -Arc Records . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 179 | | T -Text Records. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 180 | | B -Barcode Records . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 183 | | S -Surface Records . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 185 | | <layer_name>/notes (Electronic Notes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 188 | | <layer_name>/profile (Outline Shape of Layer). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 188 | | <layer_name>/tools (Drill Tools) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 191 |
<layer_name>/attrlist (Layer Attribute List)
This file contains the values for system attributes and user-defined attributes of a layer.
You can provide attrlist files at these levels: product model, symbol, wheel, step, layer.
| attrlist (Attribute List) | attrlist (Attribute List) | |-----------------------------|---------------------------------------------------------------------| | Type | Structured Text | | Compression | None | | Path | <product_model_name>/steps/<step_name>/layers/<layer_name>/attrlist | | UNITS | The UNITS directive is required. |
System attributes that can be placed in this file are listed with Entity = Layer in the attribute description. See 'System Attributes' on page 215.
└─── <product_model_name> ├─── ... ├─── steps │ └─── <step_name> │ └─── layers │ └─── <layer_name> │ └─── attrlist └─── ...
The file contains lines of this form: <attribute> = <value>
Example of a layer attrlist file
UNITS=MM .out_mirror = no .inp_file = .eda_layers = "signal_2","signal","VIA" .out_angle = 0.0 .out_polarity = positive .out_x_scale = 1.000000 .out_y_scale = 1.000000 .out_comp = 0.000000
<layer_name>/components (Components)
Each layer of type component has a unique name: comp_+_top or comp_+_bot. There can be only one of each layer name within a product model-one for the top components and one for the bottom components.
| components | components | |--------------|-----------------------------------------------------------------------| | Type | Line Record Text | | Compression | Yes | | Path | <product_model_name>/steps/<step_name>/layers/<layer_name>/components | | UNITS | The UNITS directive is required. |
Each component layer has a components file that contains information about components placed on the layer. The components file contains references to the file <step_name>/eda/data . See '<step_name>/eda (Electronic Design Automation)' on page 108.
└─── <product_model_name> ├─── ... ├─── steps │ └─── <step_name> │ └─── layers │ └─── <layer_name> │ └─── components └─── ...
Example of a component file:
# UNITS=INCH # #Component attribute names # @0 .no_pop @1 .comp_ignore @2 .desc1 @3 .comp_mount_type @4 .comp_height # #Component attribute text strings # &0 Internally created connector &1 Socket &2 ball &3 gw # CMP 0 CMP 0 1.55 8.9 270.0 N J10 2300046 ;0,2=0,3=1 PRP PART_NUMBER '1000045' PRP VALUE 'FAN1654' PRP PART_NUMBER '1000045' TOP 0 6.568 5.2296 0.0 N 8 163 1 TOP 1 6.568 5.204 0.0 N 8 164 2 TOP 2 6.568 5.1784 0.0 N 13 66 3 TOP 3 6.568 5.1528 0.0 N 2 779 4 TOP 4 6.568 5.1272 0.0 N 2 780 5 TOP 5 6.568 5.1016 0.0 N 13 67 6 TOP 6 6.568 5.076 0.0 N 8 165 7 TOP 7 6.568 5.0504 0.0 N 2 781 8 TOP 8 6.798 5.0504 0.0 N 1494 0 9 TOP 9 6.798 5.076 0.0 N 13 68 10 TOP 10 6.798 5.1016 0.0 N 12 1 11 TOP 11 6.798 5.1272 0.0 N 1143 1 12 TOP 12 6.798 5.1528 0.0 N 2 782 13 TOP 13 6.798 5.1784 0.0 N 1144 1 14 TOP 14 6.798 5.204 0.0 N 8 166 15 TOP 15 6.798 5.2296 0.0 N 1495 0 16 TOP 16 6.683 5.14 0.0 N 2 783 17 # # BOM DATA CPN M62X971EL7 PKG IPN DSC 16-ETSSOP FAN1654 VPL_VND MOTOROLA VPL_MPN MC74HC259ADT #COMP_EXT_PTY 1 VND MOTOROLA INC. MPN 0 Y MC74HC259ADT # CMP 1 CMP 3 5.017 1.791 180.0 N C400 ??? ;3=1 PRP VOLTAGE '6.3V' PRP VALUE '22UF'
TOP 0 5.072 1.791 180.0 N 87 2 1 TOP 1 4.962 1.791 180.0 N 2 245 2 # # BOM DATA CPN IZZ5FH7FX7 PKG IPN DSC B3258 22UF 6.3V VPL_VND VPL_MPN #COMP_EXT_PTY 1 VND KOA MPN 0 Y TMC1AABA106K
| Component File Section | Description | |-----------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | @and &-Component Attribute Lookup Table | This section of the component file contains a table of component attribute names and a table of all component attribute values that are strings. | | CMP -Component Record | This record contains the definition of a component. Each CMP line is followed by 0 or more property (PRP) records, and 0 or more TOP records. The pkg_ref field of the CMP record references the sequential order of the PKG records in the eda/ data file. PKG order is referenced using numbers starting from 0 and up. | | PRP-ComponentProperty Record | This record represents a property of the component. A property consists of a name, a string value, and 0 or more floating numbers. | | TOP -Component Toeprint Record | This record contains a definition of a toeprint of a component. | | BOMDescription Records | The BOMDATAsection of a component file containsBOM information for components. |
@ and & - Component Attribute Lookup Table
This section of the component file contains a table of component attribute names and a table of all component attribute values that are strings.
- Component attribute names - Each record contains an at sign (@), and index, and an attribute name. For example, @1 .comp_ignore.
- Feature attribute text strings - Each record contains an ampersand (&), an index, and a text string that can be used as the value of an attribute of type TEXT. For example, &3 gw.
System attributes that can be placed in this table are listed with Entity = Comp. in the attribute description. See 'System Attributes' on page 215.
This section must be placed before the first CMP record of the file.
The CMP records in the file can assign component attributes by referencing the index of a component attribute and, for attributes of type TEXT, the index of the text string that is the value assigned to the attribute.
This is an example of a component attribute lookup table, and a CMP record that assigns attributes. The string 0,2=0,3=1 in the CMP record in the example should be interpreted as assigning these attributes to the component:
#Component attribute names # @0 .no_pop @1 .comp_ignore @2 .desc1 @3 .comp_mount_type @4 .comp_height # # &0 Internally created connector &1 Socket &2 ball &3 gw
#Component attribute text strings # CMP 0 CMP 0 1.55 8.9 270.0 N J10 2300046 ;0,2=0,3=1
| Assignment in theCMP Record | Line in the Table of Attribute Names | Attribute Type | Line in the Table of Attribute Text Strings | Result | |-------------------------------|----------------------------------------|------------------|-----------------------------------------------|-------------------------------------------------------------------------------------------------------------------------| | 0 | @0 .no_pop | BOOLEAN | - | .no_pop = TRUE | | 2=0 | @2 .desc1 | TEXT | &0Internally created connector | .desc1 = Internally created connector | | 3=1 | @3 .comp_mount_type | OPTION | - | .comp_mount_type = SMT Options for the .comp_mount_type attributes are: Other, SMT, THMT, PressFit, so 1 indicates SMT. |
CMP - Component Record
This record contains the definition of a component. Each CMP line is followed by 0 or more property (PRP) records, and 0 or more TOP records. The pkg_ref field of the CMP record references the sequential order of the PKG records in the eda/data file. PKG order is referenced using numbers starting from 0 and up.
See 'PKG - Package Record' on page 116.
This is the format of the CMP component record:
CMP <pkg_ref> <x> <y> <rot> <mirror> <comp_name> <part_name>; <attributes>;ID=<id>
| Field | Explanation | |------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | pkg_ref | Reference number of the package in the eda/data file. See '<step_name>/eda (Electronic Design Automation)' on page 108. | | x, y | Board location of the component in inches or mm. | | rot | Rotation of the component, in degrees, clockwise. | | mirror | N for not mirrored, M for mirrored. | | comp_name | Unique reference designator (component name); a single string of ASCII characters without spaces. Upper case and lower case characters are not equivalent. | | part_name | Part identification is a single string of ASCII characters without spaces. | | attributes | A comma separated list of attribute assignments. The attribute is indicated by its index in the attribute name lookup table. • BOOLEAN -nindicating that attribute n is set. • OPTION -n=mindicating that attribute n has value m. • INTEGER -n=i indicating that attribute n has value i. • FLOAT -n=f indicating that attribute n has value f. • TEXT -n=sindicating that attribute n has the value associated with index s in the attribute text string lookup table. See '@ and &-Component Attribute Lookup Table' on page 155. | | ID=<id> | Assigns a unique identifier to the component. See 'Unique ID' on page 30. |
PRP - Component Property Record
This record represents a property of the component. A property consists of a name, a string value, and 0 or more floating numbers.
The PRP file has this format:
PRP <name> '<value>' n1 n2 ...,
| Field | Explanation | |-----------|-----------------------------------------------------------| | name | Name of the property. | | value | String of the property (between quotes; no restrictions). | | n1,n2,... | Floating numbers to be kept in the property. |
TOP - Component Toeprint Record
This record contains a definition of a toeprint of a component.
This is the format of the TOP record:
TOP <pin_num> <x> <y> <rot> <mirror> <net_num> <subnet_num> <toeprint_name>,
| Field | Explanation | |---------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | pin_num | Pin number inside the package of the component. | | x, y | Board location of the pin in inches or mm. | | rot | Rotation of the component, in degrees, clockwise. | | mirror | N for not mirrored, Mfor mirrored. | | net_num | Number of net in the eda/data file. The net_num used in the TOP record corresponds to the sequence of the NET records in the eda/data file. The first NET record is net_num 0, the second is net_num 1 and so on. | | subnet_num | Number of subnet (SNT record) in the referenced net. | | toeprint_name | Name of the toeprint. |
BOM Description Records
The BOM DATA section of a component file contains BOM information for components.
| Parameter | Description | |-------------|-----------------------------------| | CPN | Customer part number. | | PKG | Package name. | | IPN | Internal part number. | | DSC | Unlimited number of descriptions. |
| Parameter | Description | |-------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | VPL_VND | Manufacturer from an external vendor part library corresponding to original vendor (as determined in BOMValidation). | | VPL_MPN | MPN from an external vendor part library corresponding to original MPN (as determined in BOMValidation). | | VND | Manufacturer (vendor) name. | | MPN | Manufacturer part number. The MPN lines contain these parameters separated by spaces: • qualify status -Whether the part (vendor+mpn) is qualified for production: • -1 -Not qualified. • 0 -Unknown. • 1 -Qualified. • chosen status -Whether the part is chosen from among the alternate parts for the CPN. Only one part can be a chosen part. • 0 -Not chosen. • 1 -Chosen. • MPN -The manufacturer part number. For example, MPN 0 Y 4N35S for a CPN component whose qualification is unknown (0), that is the chosen component (1), with a manufacturer part number of 4N35S. |
Example of Alternate Parts
This is an example of alternate parts defined for the same CPN. The first is chosen, and the third is not qualified. These sections repeat for all the alternate parts of the CPN: VPL_VND, VPL_MPN, VND, and MPN.
CPN 69K9KMH12B LNFILE 51 name_of_bom_file.txt VPL_MPN MAX5156ACEE VPL_VND MAXIM MPN MAX5156ACEE LNFILE 51 name_of_bom_file.txt VND MAXIM LNFILE 51 name_of_bom_file.txt QLF 0 CHS 1 PRIORITY 1
CPN 69K9KMH12B LNFILE 51 name_of_bom_file.txt VPL_MPN CY22150FC VPL_VND CYPRESS MPN CY22150FC LNFILE 52 name_of_bom_file.txt VND CYPRESS LNFILE 52 name_of_bom_file.txt QLF 0 CHS 0 PRIORITY 2
CPN 69K9KMH12B LNFILE 51 name_of_bom_file.txt VPL_MPN AT93C66-10SC VPL_VND ATMEL MPN AT93C66-10SC LNFILE 53 name_of_bom_file.txt VND ATMEL LNFILE 53 name_of_bom_file.txt QLF -1 CHS 0
PRIORITY 0
<layer_name>/dimensions (Dimensions)
Dimensions that have been added to a layer to indicate measurements of objects on the layer are stored with the product model.
| dimensions (Dimensions) | dimensions (Dimensions) | |---------------------------|------------------------------------------------------------------------| | Type | Structured Text | | Compression | Yes | | Path | <product_model_name>/steps/<step_name>/layers/<layer_name>/ dimensions | | UNITS | The UNITS directive is required. |
└─── <product_model_name> ├─── ... ├─── steps │ └─── <step_name> │ └─── layers │ └─── <layer_name> │ └─── dimensions └─── ...
Example of a Dimensions File:
VERSION=1 UNITS=INCH PARAMETERS { ID=0 LINE_WIDTH=0.01 POST_DECIMAL_DIST=3 POST_DECIMAL_POS=3 POST_DECIMAL_ANGLE=1 FONT=STANDARD FONT_WIDTH=0.07 FONT_HEIGHT=0.05 EXT_OVERLEN=0.02 EXT_OFFSET=0.01 CENTER_MARKER_LEN=0.05 BASELINE_SPACING=0.012 ORIGIN_X=0 ORIGIN_Y=0 SCALE=100 PAPER { ORIENTATION=PORTRAIT SIZE=A4 WIDTH=8.3 HEIGHT=11.7 X=0 Y=0 MARGIN { TOP=0.1 BOTTOM=0.1 LEFT=0.2 RIGHT=0.2 } ACTIVE { X00=1 Y00=1 X11=8 Y11=11 } COLOR { FEATURE=RED DIMENS=BLUE DIMENS_TEXT=GREEN PROFILE=BLACK TEMPLATE=GRAY } } DIMENSION { TYPE=HORIZONTAL PARAMETERS=0 REF1X=0.1 REF1Y=0.2 REF2X=1.2 REF2Y=0.3 REF3X=0 REF3Y=0 LINE_PT_X=1.2
LINE_PT_Y=0.7 OFFSET=0 ARROW_POS=AUTOMATIC MAGNIFY=1 TO_ARC_CENTER=NO TWO_SIDED_DIAM=NO TEXT { VALUE=27.94 PREFIX= SUFFIX= NOTE= UNITS=MM VIEW_UNITS=YES OUTSIDE=NO UNDERLINE=NO TOL_UP= TOL_DOWN= MERGE_TOL=NO X=0.65 Y=0.7 ANGLE=0 } DIMENSION { TYPE=VERTICAL PARAMETERS=0 REF1X=0.3 REF1Y=0.8 REF2X=0.3 REF2Y=0.1 REF3X=0 REF3Y=0 LINE_PT_X=-0.1 LINE_PT_Y=0.1 OFFSET=0 ARROW_POS=AUTOMATIC MAGNIFY=1 TO_ARC_CENTER=NO TWO_SIDED_DIAM=NO TEXT { VALUE=17.78 PREFIX= SUFFIX= NOTE= UNITS=MM VIEW_UNITS=YES OUTSIDE=YES UNDERLINE=NO TOL_UP= TOL_DOWN= MERGE_TOL=NO X=-0.1 Y=-0.15231 ANGLE=90 } DIMENSION { TYPE=PARALLEL PARAMETERS=0 REF1X=0.3
REF1Y=-0.2 REF2X=0.6 REF2Y=-0.5 REF3X=0 REF3Y=0 LINE_PT_X=0.7 LINE_PT_Y=-0.4 OFFSET=0 MAGNIFY=1 TO_ARC_CENTER=NO TWO_SIDED_DIAM=NO TEXT { VALUE=10.776 PREFIX= SUFFIX= NOTE= UNITS=MM VIEW_UNITS=YES OUTSIDE=YES UNDERLINE=NO TOL_UP= TOL_DOWN= MERGE_TOL=NO X=1.0021572 Y=-0.702157 ANGLE=45 }
| Global Parameters for Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 164 | |----------------------------------------------------------------------------------------------------------------------------|-------| | PARAMETERS Array Structure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 165 | | DIMENSION Array Structure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 166 | | PAPER Array Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 167 | | TEXT Array Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 168 |
ARROW_POS=AUTOMATIC Global Parameters for Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164 PARAMETERS Array Structure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165 DIMENSION Array Structure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166 PAPER Array Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167 TEXT Array Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168
Global Parameters for Dimensions
These are the global parameters.
| Field | Explanation | |---------|----------------------------------------------------------------------------------------| | VERSION | File version. <int>, >= 0 | | UNITS | Units of all coordinates and floating numbers. <string> Possible values: INCH |MM |
PARAMETERS Array Structure
This is the array structure of each parameter set.
| Field | Explanation | |---------------------|---------------------------------------------------------------------------------------------------------------------------------------------------| | ARROW_STYLE | Controls the appearance of the dimension arrow. Optional. <int>, >= 0 | | ID | The ID of this parameter set. DIMENSION records reference parameter sets by this number. See 'DIMENSION Array Structure' on page 166. <int>, >= 0 | | LINE_WIDTH | Dimension line width. <float>, 0 - 500 mil | | POST_DECIMAL_D IST | Number of decimal digits for size type dimensions. <int>, 0 - 6 | | POST_DECIMAL_P OS | Number of decimal digits for LOCATION type dimensions. <int>, 0 - 6 | | POST_DECIMAL_A NGLE | Number of decimal digits for ANGLE type dimensions. <int>, 0 - 6 | | FONT | Name of a font from the fonts folder of the product model. <string> | | FONT_WIDTH | Width of text letters. <float>, 0 - 5000 mil | | FONT_HEIGHT | Height of text letters. <float>, 0 - 5000 mil | | EXT_OVERLEN | Extension overlength for HORIZONTAL | VERTICAL | PARALLEL | ANGLE. <float>, -100 INCH - 100 INCH | | EXT_OFFSET | Extension offset for HORIZONTAL | VERTICAL | PARALLEL | ANGLE. <float>, -100 INCH - 100 INCH | | CENTER_MARKER _LEN | Cross size for CENTER dimension. <float>, 0 - 100 INCH | | BASELINE_SPACI NG | Spacing for HORIZONTAL, VERTICAL, PARALLEL. <float>, 0 - 100 INCH | | ORIGIN_X | <x coordinate>, -100 INCH - 100 INCH |
| Field | Explanation | |----------|-----------------------------------------------------------| | ORIGIN_Y | <y coordinate>, -100 INCH - 100 INCH | | SCALE | Frontline scaling percent. <float>, 0 - 100 | | PAPER | The PAPER array. See 'PAPER Array Structure' on page 167. |
DIMENSION Array Structure
This is the dimension array structure.
| Field | Explanation | |------------|-------------------------------------------------------------------------------------------------------------------------------------------------------| | TYPE | <string> Possible values:HORIZONTAL|VERTICAL|PARALLEL|RADIUS | DIAMETER | CHAMFER | CENTER | LOCATION | ANGLE | | PARAMETERS | The ID number of a parameter set. See 'PARAMETERS Array Structure' on page 165. <int> | | REF1X | <x coordinate>, -100 INCH - 100 INCH | | REF1Y | <y coordinate>, -100 INCH - 100 INCH | | REF2X | <x coordinate>, -100 INCH - 100 INCH Not relevant to CENTER. | | REF2Y | <y coordinate>, -100 INCH - 100 INCH Not relevant to CENTER. | | REF3X | <x coordinate>, -100 INCH - 100 INCH Relevant to RADIUS, DIAMETER, CHAMFER, LOCATION, ANGLE. | | REF3Y | <y coordinate>, -100 INCH - 100 INCH Relevant to RADIUS, DIAMETER, CHAMFER, LOCATION, ANGLE. | | LINE_PT_X | <x coordinate>, -100 INCH - 100 INCH Not relevant to CENTER. | | LINE_PT_Y | <y coordinate>, -100 INCH - 100 INCH Not relevant to CENTER. | | OFFSET | Offset for RADIUS, DIAMETER, CHAMFER, LOCATION. <float>, -100 INCH - 100 INCH |
| Field | Explanation | |-----------------|-----------------------------------------------------------------------| | ARROW_POS | <string> Possible values: AUTOMATIC | INSIDE | OUTSIDE | | MAGNIFY | Frontline magnifcation percent. <float>, 0 - 100 | | TEXT | The TEXT array. See 'TEXT Array Structure' on page 168. | | TO_ARC_CENTER | <string> Possible values: NO | YES Relevant to RADIUS, DIAMETER. | | TWO_SIDED_DIA M | <string> Possible values: NO | YES Relevant to RADIUS, DIAMETER. |
PAPER Array Structure
This is the array structure for the Frontline paper definitions. It is included in the PARAMETERS array.
| Field | Explanation | |-------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | ORIENTATION | <string> Possible values: NONE | PORTRAIT | LANDSCAPE | | SIZE | <string> Possible values for the Postscript paper size: A0 | A1 | A2 | A3 | A4 | A5 | B4 | B5 | LETTER | LIFE | CUSTOM | | WIDTH | <float> | | HEIGHT | <float> | | X | <float> | | Y | <float> | | MARGIN | The MARGIN array contains this information: TOP = <float> BOTTOM = <float> LEFT = <float> RIGHT = <float> |
| Field | Explanation | |---------|-----------------------------------------------------------------------------------------------------------------------------------------------| | ACTIVE | The ACTIVE array contains this information: X00 = <float> Y00 = <float> X11 = <float> Y11 = <float> | | COLOR | The COLOR array contains this information: FEATURE = <string> DIMENS = <string> DIMENS_TEXT = <string> PROFILE = <string> TEMPLATE = <string> |
TEXT Array Structure
The TEXT array structure is not relevant to the CENTER dimension. It is included in the DIMENSIONS array.
| Field | Explanation | |------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------| | PREFIX | <string>, 0-20 characters | | SUFFIX | <string>, 0-20 characters | | VALUE | <string>, 0-40 characters | | NOTE | <string>, 0-100 characters | | UNITS | <string> Possible values: INCH | MM| MIL | MICRON | DEGREE | RADIAN GRADIAN Options DEGREE, RADIAN, and GRADIAN are relevant to ANGLE only. | | VIEW_UNITS | <string> Possible values: NO | YES | | TOL_UP | <string>, 0-11 characters | | TOL_DOWN | <string>, 0-11 characters | | MERGE_TOL | <string> Possible values: NO | YES |
| Field | Explanation | |-----------|--------------------------------------------------------------------------------| | OUTSIDE | <string> Possible values: NO | YES Not relevant to LOCATION. | | UNDERLINE | <string> Possible values: NO | YES Relevant to RADIUS, DIAMETER, CHAMFER. | | X | <x coordinate>, -100 INCH - 100 INCH | | Y | <y coordinate>, -100 INCH - 100 INCH | | ANGLE | <float>, 0-360 degrees |
<layer_name>/features (Graphic Features)
The features file contains definitions of graphic features.
| features | features | |-------------|---------------------------------------------------------------------| | Type | Line Record Text | | Compression | Yes | | Path | <product_model_name>/steps/<step_name>/layers/<layer_name>/features | | UNITS | The UNITS directive is required. |
The features file contains most of the graphic information representing the physical board layers, NC drill and rout layers, and miscellaneous drawings. The features file should be present only for layers of these types.
<!-- image -->User-defined symbols have a features file to describe their shape. See 'symbols (User-Defined Symbols)' on page 94.
The files defining a step profile or a layer profile have the same format as a features file. The file defines a single surface feature:
- '<step_name>/profile (Outline Shape of Step)' on page 141
- '<layer_name>/profile (Outline Shape of Layer)' on page 188
Example of a features file:
UNITS=MM ID=216 # #Num Features # F 1406 # #Feature symbol names # $0 r120 $1 rect20x60 M $2 rect3x5 I $3 punch_target # #Feature attribute names # @0 .smd @1 .nomenclature @2 .test_point @3 .geometry @4 .pad_usage # #Feature attribute text strings # &0 9796334 &1 fid_0_0_0 &2 moire &3 p115_115_115_095 # #Layer features # P -0.198 1.62 16 P 0 3;3=2,4=0;ID=123456 P 0.118 1.62 16 P 0 3;3=25,4=0;ID=5678 L 3.834 -1.16 3.86728 -1.16 2 P 0 ;1,3=0 L 3.86728 -1.16 3.8782 -1.16485 2 P 0 ;1,3=0 ... S P 0;ID=123456 OB -0.013 2.427 I OS -0.013 2.218 OS -0.263 2.218 OS -0.263 2.427 OS -0.219 2.427 OS -0.219 2.262 OS -0.057 2.262 OS -0.057 2.427 OS -0.013 2.427 OE SE ...
The file consists of the UNITS, ID, and F records, a section that lists symbol names, an attribute lookup table, and lines or structures defining the various types of features.
| Section | Description | |---------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | UNITS -Measurement Units | Features and coordinates are saved in the units in which they were created, to avoid loss of precision due to rounding. | | ID -Unique ID (Optional) | This file can contain a unique ID. | | F -Number of Features (Optional) | An optional line of the features file indicates the actual number of feature records that there are in the file. If available, this information could be used to determine what actions to take when reading the features file content. | | $ -Feature Symbol Names Section | This section lists the symbols used to construct lines, pads, or arcs defined in the file. It contains the names of all the symbols used by the features in the file and corresponding serial numbers for reference by the feature records. | | @and &-Feature Attribute Lookup Table | This section of the file contains a table of feature attribute names and a table of all feature attribute values that are strings. The feature definition records can assign attributes by referencing the index of an attribute and, for attributes of type TEXT, the index of the text string that is the value assigned to the attribute. | | L -Line Records | These records define a line. | | P -Pad Records | These lines define a pad. | | A -Arc Records | These lines define an arc. | | T -Text Records | These lines define text. | | B -Barcode Records | These records define a barcode. | | S -Surface Records | A surface definition must have at least one polygon defined. The surface usually consists of multiple records. |
UNITS - Measurement Units
Features and coordinates are saved in the units in which they were created, to avoid loss of precision due to rounding.
In every features file, there must be a UNITS directive that indicates the units of measurement to be applied to the features in the file. See 'Units of Measurement' on page 23.
This is the format of the line: UNITS=<MM_or_INCH>.
- UNITS=MM - Indicates that metric units of measurement are used in the file.
- UNITS=INCH - Indicates that imperial units of measurement are used in the file.
If the UNITS directive does not exist in the features file, the units defined for the product model are assumed. If the misc/info file of the product model does not contain a UNITS directive, imperial units are assumed.
All coordinate values will be interpreted as inches or millimeters. Resize factors for userdefined symbols are interpreted as mils or microns. Exceptions are discussed where relevant.
This also applies to semi-standard symbols described in the features file. See '$ - Feature Symbol Names Section' on page 174.
The UNITS directive in the features file sets the units to be used for symbols that do not specify units. In the example, units of measurement are set to metric.
Example of Interpretation of Symbol Dimensions
# UNITS=MM # #Feature symbol names # $0 r120 $1 rect20x60 M $2 rect3x5 I $3 punch_target
...
In the example, the units of measurement are specified for the file and also for some of the symbols:
- r120 - Standard round symbol with units in microns.
- rect20x60 M - Standard rectangle symbol with units in microns. X is 20 microns and Y is 60 microns.
- rect3x5 I - Standard rectangle with units in mils. X is 3 mils and Y is 5 mils.
- punch_target - User-defined symbol. This must exist in the symbol directory of the product model.
ID - Unique ID (Optional)
This file can contain a unique ID.
This is the format of the line: ID=<id>.
See 'Unique ID' on page 30.
F - Number of Features (Optional)
An optional line of the features file indicates the actual number of feature records that there are in the file. If available, this information could be used to determine what actions to take when reading the features file content.
This is the format of the line: F <number_of_features>.
$ - Feature Symbol Names Section
This section lists the symbols used to construct lines, pads, or arcs defined in the file. It contains the names of all the symbols used by the features in the file and corresponding serial numbers for reference by the feature records.
This is the format of the line: $<serial_num> <symbol_name> [<I|M>]
The parameter I or M can be added at the end of the line to indicate that the dimensions in this symbol name are expressed in imperial units or metric units.
Each line, pad, or arc feature definition record lists the index of the symbol used to construct that feature.
For a list of standard symbol names, see 'Standard ODB++ Symbols' on page 195.
Example of the Feature Symbol Names Section
# #Feature symbol names # $0 r120 $1 rect20x60 M $2 rect3x5 I $3 punch_target
@ and & - Feature Attribute Lookup Table
This section of the file contains a table of feature attribute names and a table of all feature attribute values that are strings. The feature definition records can assign attributes by referencing the index of an attribute and, for attributes of type TEXT, the index of the text string that is the value assigned to the attribute.
- Feature attribute names - Each record contains an at sign (@), and index, and an attribute name. For example, @1 .nomenclature.
- Feature attribute text strings - Each record contains an ampersand (&), an index, and a text string that can be used as the value of an attribute of type TEXT. For example, &2 moire.
System attributes that can be placed in this table are listed with Entity = Feature in the attribute description. See 'System Attributes' on page 215
This section must be placed before the layer features section of the file.
The feature definition records in the file can assign feature attributes by referencing the index of a feature attribute and, for attributes of type TEXT, the index of the text string that is the value assigned to the attribute.
Example of a Feature Attribute Lookup Table
This is an example of a feature attribute lookup table, and a feature definition record that assigns attributes:
# #Feature attribute names # @0 .smd @1 .nomenclature @2 .test_point @3 .geometry @4 .pad_usage # #Feature attribute text strings # &0 9796334 &1 fid_0_0_0 &2 moire &3 p115_115_115_095 # #Layer features # P -0.198 1.62 16 P 0 3;3=2,4=0;ID=123456
The string 3=2,4=0 in the feature definition record in the example should be interpreted as assigning these attributes to the feature:
| Feature Definition Record Assignment | Line in the Table of Attribute Names | Attribute Type | Line in the Table of Attribute Text Strings | Result | |----------------------------------------|----------------------------------------|------------------|-----------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------| | 3=2 | @3 .geometry | TEXT | &2 moire | .geometry = moire | | 4=0 | @4 .pad_usage | OPTION | - | .pad_usage = toeprint Options for the .pad_usage attribute are: toeprint; via; g_fiducial; l_fiducial; tooling_hole, so 0 indicates toeprint. |
L - Line Records
These records define a line.
This is the format of a line record:
L <xs> <ys> <xe> <ye> <sym_num> <polarity> <dcode>;<atr>=<value>,...;ID=<id>
| Line Record Parameter | Explanation | |-------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | type | L | | xs, ys | Start point. | | xe, ye | End point. | | sym_num | The index of the feature used to construct the line, in the feature symbol names section. See '$ -Feature Symbol Names Section' on page 174. | | polarity | P -Positive. N -Negative. | | dcode | Gerber dcode number or Excellon tool number (0 if not defined). | | atr | An attribute number, referencing an attribute from the feature attribute names section. See '@ and &-Feature Attribute Lookup Table' on page 174. | | value | An attribute value that depends on the type of attribute: • BOOLEAN -Novalue is necessary. If the index of the attribute is listed, the attribute is set to TRUE. • FLOAT or INTEGER -Anumber. • OPTION -Anoption number. • TEXT -Anumber referencing the feature attribute text strings section. See '@ and &-Feature Attribute Lookup Table' on page 174. | | ID=<id> | Assigns a unique identifier to the feature. See 'Unique ID' on page 30. |
Example of a Line Record in a Features File
L 5.15 0.35 5.125 0.325 0 P 0
P - Pad Records
These lines define a pad.
This is the format of a line record:
P <x> <y> <apt_def> <polarity> <dcode> <orient_def>;<atr>=<value>,...;ID=<id>
| Pad Parameter | Explanation | |-----------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | x, y | Center point. | | apt_def | The index, in the feature symbol names section, of the symbol to be used to draw the pad. This value can be expressed in one of these ways: • <sym_num> -The symbol with index <sym_num> is used as is. • -1 <sym_num> <resize_factor> -The symbol with index <sym_num> is enlarged or shrunk by factor <resize_factor>. The resize factor is expressed in thousandths of the units being used (mils or microns). See '$ -Feature Symbol Names Section' on page 174. | | polarity | P -Positive. N -Negative. | | dcode | Gerber dcode number or Excellon tool number (0 if not defined). | | orient_def | Pad orientation. This value is expressed as: 0|1|2|3|4|5|6|7|8<rotation>|9<rotation> If the first number of orientation definition is an integer from 0 through 7 , it is legacy data and will be handled accordingly. These values are read from legacy data to maintain backward compatibility. 0 -0degrees rotation, no mirror. 1 -90 degrees rotation, no mirror. 2 -180 degrees rotation, no mirror. 3 -270 degrees rotation, no mirror. 4 -0degrees rotation, mirror in x-axis. 5 -90 degrees rotation, mirror in x-axis. 6 -180 degrees rotation, mirror in x-axis. 7 -270 degrees rotation, mirror in x-axis. If the first number is 8 or 9, it is a two number definition, with the following number representing rotation. 8 -Any angle rotation, no mirror. 9 -Any angle rotation, mirror in x-axis. When pads are both rotated and mirrored, they are rotated first, and then mirrored along the x-axis. |
| Pad Parameter | Explanation | |-----------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | atr | An attribute number, referencing an attribute from the feature attribute names section. See '@ and &-Feature Attribute Lookup Table' on page 174. | | value | An attribute value that depends on the type of attribute: • BOOLEAN -Novalue is necessary. If the index of the attribute is listed, the attribute is set to TRUE. • FLOAT or INTEGER -Anumber. • OPTION -Anoption number. • TEXT -Anumber referencing the feature attribute text strings section. See '@ and &-Feature Attribute Lookup Table' on page 174. | | ID=<id> | Assigns a unique identifier to the feature. See 'Unique ID' on page 30. |
Example of Pad Records in a Features File
Special pad const_1 at location x=1.0, y=2.0 positive, with dcode 4, is used as an example for different transformations:
# #Feature symbol names # $0 const_1 # #Feature attribute names # @0 .smd 1 .nomenclature 2 .test_point 3 .geometry 4 .pad_usage ..... # P 1.0 2.0 0 P 4 1;;ID=3948 P 1.0 2.0 0 P 4 8 30.0;;ID=7205 P 1.0 2.0 -1 0 0.02 P 4 1;;ID=7421 P 1.0 2.0 -1 0 0.02 P 4 8 30.0;;ID=9630
In the example,
P 1.0 2.0 0 P 4 1 is rotated by 90 degrees (orient_def = 1).
P 1.0 2.0 0 P 4 8 30.0 is rotated by 30 degrees (orient_def = 8 30.0).
P 1.0 2.0 -1 0 0.02 P 4 1 is rotated by 90 degrees, and resized by 0.02 mil (apt_def = -1 0 0.02 and orient_def = 1).
P 1.0 2.0 -1 0 0.02 P 4 8 30.0 is rotated by 30, and resized by 0.02 mil (apt_def = -1 0 0.02 and orient_def = 8 30.0).
A - Arc Records
These lines define an arc.
This is the format of an arc definition record:
A <xs> <ys> <xe> <ye> <xc> <yc> <sym_num> <polarity> <dcode> <cw>;<atr>=<value>,...;ID=<id>
| Arc Parameter | Explanation | |-----------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | xs, ys | Start point. When the start and end-point of an arc coincide, it is considered a 360 degree arc. There are no single-point arcs in ODB++ format. | | xe, ye | End point. When the start and end-point of an arc coincide, it is considered a 360 degree arc. There are no single-point arcs in ODB++ format. | | xc, yc | Center point. | | sym_num | The index, in the feature symbol names section, of the symbol to be used to draw the arc. See '$ -Feature Symbol Names Section' on page 174. | | polarity | P for positive, N for negative. | | dcode | Gerber dcode number or Excellon tool number (0 if not defined). | | cw | Y for clockwise, N for counter clockwise. | | atr | An attribute number, referencing an attribute from the feature attribute names section. See '@ and &-Feature Attribute Lookup Table' on page 174. | | value | An attribute value that depends on the type of attribute: • BOOLEAN -Novalue is necessary. If the index of the attribute is listed, the attribute is set to TRUE. • FLOAT or INTEGER -Anumber. • OPTION -Anoption number. • TEXT -Anumber referencing the feature attribute text strings section. See '@ and &-Feature Attribute Lookup Table' on page 174. | | ID=<id> | Assigns a unique identifier to the feature. See 'Unique ID' on page 30. |
Example of an Arc Record in a Features File
A 1.49401033 2.53683297 0.8389936 2.48563819 1.17858858 2.35659203 2 P 0 Y
T - Text Records
These lines define text.
This is the format of a text definition record:
T <x> <y> <font> <polarity> <orient_def> <xsize> <ysize> <width_factor> <text> <version>;<atr>=<value>,...;ID=<id>
| Text Parameter | Explanation | |------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | x, y | Text location (bottom left of first character for 0 orientation). | | font | Font name. | | polarity | P for positive, N for negative. | | orient_def | Text orientation. This value is expressed as: 0|1|2|3|4|5|6|7|8<rotation>|9<rotation> If the first number of orientation definition is an integer from 0 through 7 , it is legacy data and will be handled accordingly. These values are read from legacy data to maintain backward compatibility. 0 -0degrees rotation, no mirror. 1 -90 degrees rotation, no mirror. 2 -180 degrees rotation, no mirror. 3 -270 degrees rotation, no mirror. 4 -0degrees rotation, mirror in x-axis. 5 -90 degrees rotation, mirror in x-axis. 6 -180 degrees rotation, mirror in x-axis. 7 -270 degrees rotation, mirror in x-axis. If the first number is 8 or 9, it is a two number definition, with the following number representing rotation. 8 -Any angle rotation, no mirror. 9 -Any angle rotation, mirror in x-axis. When pads are both rotated and mirrored, they are rotated first, and then mirrored along the x-axis. | | xsize, ysize | Character size. xsize -Character width including the following space. ysize -Height of a capital character |
<!-- image -->| Text Parameter | Explanation | |------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | width_factor | The width of character segment (in units of 12 mils); that is, 1 = 12 mils, 0.5 = 6 mils | | text | Text string enclosed in single quotes. The text string can contain dynamic text variables such as $$DATE. | | version | Defines how the first character of a text string is to be placed relative to the insertion point. 0 -Lower left corner of the text limit box coincides with the insertion point. 1 -Lower left corner of the widest character coincides with the insertion point. (The widest character is usually an Mor a W, by which smaller letters are centered.) The first row of text has this parameter set to 0. The second row has it set to 1. | | atr | An attribute number, referencing an attribute from the feature attribute names section. See '@ and &-Feature Attribute Lookup Table' on page 174. | | value | An attribute value that depends on the type of attribute: • BOOLEAN -Novalue is necessary. If the index of the attribute is listed, the attribute is set to TRUE. • FLOAT or INTEGER -Anumber. • OPTION -Anoption number. • TEXT -Anumber referencing the feature attribute text strings section. See '@ and &-Feature Attribute Lookup Table' on page 174. | | ID=<id> | A unique identifier for the feature. See 'Unique ID' on page 30. |
Dynamic Text Variables
A text string can include dynamic text variables that change textual value according to status or condition. For example, a variable for the date always displays the current date, as set by the system. Dynamic text variables can be located anywhere within a text string. They are distinguished by the prefix $$, as in $$DATE for the current date.
An example of a dynamic text record would be:
T 11.890963 13.697185 standard P 8 0 5.08 5.08 2.00000 '$$DATE-MMDDYY' 1
Where the variable $$DATE-MMDDYY displays the date as 05/30/17.
The ODB++ format supports these dynamic text variables:
| Variable | Descriptions | |---------------|----------------------------------------------------------| | DATE-MMDDYY | Date expressed as month/day/year (short). | | DATE-DDMMYY | Date expressed as day/month/year (short). | | DATE-MMDDYYYY | Date expressed as month/day/year. | | DATE-DDMMYYYY | Date expressed as day/month/year. | | DD | Day of month (01-31). | | WEEK-DAY | Day of week (Sunday-Saturday). | | MM | Month of year (01-14). | | YY | Year (14). | | YYYY | Year (2014). | | WW | Week of year (01-52). | | TIME | Current time. | | JOB | Name of current product module. | | STEP | Name of step where text is placed. | | LAYER | Name of layer where text is placed. | | X | Bottom left x-coordinate of where text is placed (inch). | | Y | Bottom left y-coordinate of where text is placed (inch). | | X_MM | Bottom left x-coordinate of where text is placed (mm). | | Y_MM | Bottom left y-coordinate of where text is placed (mm). |
Example of a Text Record in a Features File
#Feature attribute names # #Layer features # T 4.033375 6.377506 standard P 8 0 0.2 0.2 2.00000 '$$DATE-DDMMYY - Coupon STD500CV' 1
The fields of the example record indicate this information:
| Parameter | Value in Example | Explanation | |--------------|----------------------------------|------------------------------------------------------------------------------------| | Record type | T | The record is text. | | Location | 4.033375 6.377506 | The x, y coordinates at the bottom left of the first character of the text string. | | Font | standard | The font is standard | | Polarity | P | The polarity is positive. | | Orientation | 8 0 | The text is rotated but not mirrored (8) with 0 degrees of rotation. | | Size | 0.2 0.2 | The x, y size of text string (by layer units). | | Width factor | 2.00000 | The width of character segment is 24 mils. | | Text string | '$$DATE- DDMMYY-Coupon STD500CV' | This text string contains a dynamic text variable. It contains a space. | | Version | 1 | The lower left corner of the widest character coincides with the insertion point. |
B - Barcode Records
These records define a barcode.
This is the format of the barcode definition line:
B <x> <y> <barcode> <font> <polarity> <orient_def> E <w> <h> <fasc> <cs> <bg> <astr> <astr_pos> <text>;<atr>=<value>,...;ID=<id>
| Barcode Parameter | Explanation | |---------------------|------------------------------------------------------------------| | x, y | Text location (bottom left of first character for 0 orientation. | | barcode | Barcode name (currently must be UPC39). | | font | Font name. | | polarity | P for positive, N for negative. |
<!-- image -->| Barcode Parameter | Explanation | |---------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | orient_def | Text orientation. This value is expressed as: 0|1|2|3|4|5|6|7|8<rotation>|9<rotation> If the first number of orientation definition is an integer from 0 through 7 , it is legacy data and will be handled accordingly. These values are read from legacy data to maintain backward compatibility. 0 -0degrees rotation, no mirror. 1 -90 degrees rotation, no mirror. 2 -180 degrees rotation, no mirror. 3 -270 degrees rotation, no mirror. 4 -0degrees rotation, mirror in x-axis. 5 -90 degrees rotation, mirror in x-axis. 6 -180 degrees rotation, mirror in x-axis. 7 -270 degrees rotation, mirror in x-axis. If the first number is 8 or 9, it is a two number definition, with the following number representing rotation. 8 -Any angle rotation, no mirror. 9 -Any angle rotation, mirror in x-axis. When pads are both rotated and mirrored, they are rotated first, and then mirrored along the x-axis. | | E | A constant value (reserved for future use). | | w | Element width (inches or mm). | | h | Barcode height (inches or mm). | | fasc | Y for full ASCII, N for partial ASCII. | | cs | Y for checksum, N for no checksum. | | bg | Y for inverted background, N for no background. | | astr | Y for an addition of a text string; N for only the barcode The first barcode with Iver=0 text has this parameter set to Y; the second has this parameter set to N. |
| Barcode Parameter | Explanation | |---------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | astr_pos | T for adding the string on top, B for adding the string on the bottom. | | text | Text string, enclosed in single quotes, centered on top or bottom of the barcode. The text string can contain dynamic values listed in 'T -Text Records' on page 180. | | atr | An attribute number, referencing an attribute from the feature attribute names section. See '@ and &-Feature Attribute Lookup Table' on page 174. | | value | An attribute value that depends on the type of attribute: • BOOLEAN -Novalue is necessary. If the index of the attribute is listed, the attribute is set to TRUE. • FLOAT or INTEGER -Anumber. • OPTION -Anoption number. • TEXT -Anumber referencing the feature attribute text strings section. See '@ and &-Feature Attribute Lookup Table' on page 174. | | ID=<id> | Assigns a unique identifier to the feature. See 'Unique ID' on page 30. |
Example of a Barcode Record in the Features File
UNITS=INCH # #Feature attribute names # @0 .nomenclature # #Layer features # B -1.73493967 0.25060236 UPC39 standard P 8 0 E 0.008 0.2 Y N Y Y T 'Barcode 1234567890';0
S - Surface Records
A surface definition must have at least one polygon defined. The surface usually consists of multiple records.
This is the format of the surface definition:
S <polarity> <dcode>;<atr>=<value>,...;ID=<id> <polygon 1> <polygon n> SE
The S line is followed by polygon definitions. Each polygon is a collection of segments (lines without width) and curves (arcs without width). The polygons must meet the restrictions described in 'Surfaces' on page 38.
It is recommended that each polygon be represented as a single island, because a multi-island polygon is electrically disconnected. As a single feature, it should be connected to a single net.
A polygon begins with an OB command, contains OS (segment) or OC (arc) commands, and ends with an OE command:
OB <xbs> <ybs> <poly_type> OS <x> <y> ... OC <xe> <ye> <xc> <yc> <cw> ... OE
The last OS or OC coordinate should be the same as the OB coordinate.
S Records
These are the parameters for the S line:
| S Parameter | Explanation | |---------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | polarity | P -Positive. N -Negative. | | dcode | Gerber dcode number or Excellon tool number (0 if not defined). | | atr | An attribute number, referencing an attribute from the feature attribute names section of the lookup table. See '@ and &-Feature Attribute Lookup Table' on page 174. | | value | An attribute value that depends on the type of attribute: • BOOLEAN -Novalue is necessary. If the index of the attribute is listed, the attribute is set to TRUE. • FLOAT or INTEGER -Anumber. • OPTION -Anoption number. • TEXT -Anumber referencing the feature attribute text strings section of the lookup table. See '@ and &-Feature Attribute Lookup Table' on page 174. | | ID=<id> | Assigns a unique identifier to the feature. See 'Unique ID' on page 30. |
OB Records
These are the parameters of the OB (begin) line:
| OB Parameter | Explanation | |----------------|---------------------------------| | xbs, ybs | Beginning point of the polygon. | | poly_type | I for island, H for hole. |
OS Records
These are the parameters of the OS (segment) lines:
| OS Parameter | Explanation | |----------------|-------------------------------------------------------------------| | x, y | Segment end point. The previous polygon point is the start point. | | cw | Y for clockwise, N for counter-clockwise. |
OC Records
These are the parameters of the OC (arc) lines:
| OC Parameter | Explanation | |----------------|-----------------------------------------------------------------| | xe, ye | Curve end point. The previous polygon point is the start point. | | xc, yc | Curve center point. | | cw | Y for clockwise, N for counter-clockwise. |
Example of Surface Records in the Feature File
S P 0 OB 5.36 3.525 I OS 5.36 3.809 OS 5.501 3.809 OS 5.501 3.735 OS 5.431 3.735 OS 5.431 3.525 OS 5.36 3.525 OE OB 5.593 3.525 I OS 5.593 3.73 OS 5.75 3.73 OS 5.75 3.525 OS 5.593 3.525 OE SE
<layer_name>/notes (Electronic Notes)
The notes file contains notes added by the user.
| notes (Electronic Notes) | notes (Electronic Notes) | |----------------------------|------------------------------------------------------------------| | Type | Line Record Text | | Compression | None | | Path | <product_model_name>/steps/<step_name>/layers/<layer_name>/notes | | UNITS | The UNITS directive is not relevant for the notes file. |
This file contains all the notes added by the user to the graphic layer.
<!-- image -->Example of a notes file
866467418,moshik,2.03807,-1.22818,,,,,,First line\nSecond line
Each line in the notes file has this format:
<time>,<user>,<x>,<y>,,,,,,<note>
| Field | Explanation | |---------|----------------------------------------------------------------------------------------------------------------------------------| | time | Last date updated. Uses a standard UNIX time code method that is the number of seconds that have passed since January 1st, 1970. | | user | User who most recently updated the note. | | x, y | Graphic location expressed in accordance with UNITS=MM|INCH. | | note | Up to four lines of text where the \n character describes the line break |
<layer_name>/profile (Outline Shape of Layer)
The layer profile is defined as a multi-island contour according to ODB++ contour definition.
See 'Geometric Entities' on page 39. Every island can contain several holes. The island must completely surround its holes, and the holes must not touch one another or intersect within the island. No other features are considered legal for the layer profile.
| profile | profile | |-------------|--------------------------------------------------------------------| | Type | Line Record Text | | Compression | Yes | | Path | <product_model_name>/steps/<step_name>/layers/<layer_name>/profile | | UNITS | The UNITS directive is required. |
The layer profile is optional. A layer can contain one profile or no profile. The layer profile contains information relating to a single layer profile-the outline of the layer profile and its related attributes. All are optional.
└─── <product_model_name> ├─── ... ├─── steps │ └─── <step_name> │ └─── layers │ └─── <layer_name> │ └─── profile └─── ...
The layer profile is primarily used for rigid-flex boards, where the rigid and flex parts of the board might have different physical limits. A layer profile is used to define these physical limits.
If a step profile hole is found within a layer profile island or if it intersects a layer profile island, the step profile hole is considered to exist along with the layer profile holes. It is not necessary to create the step profile holes in the layer profile. If the step profile hole intersects the layer profile island, the layer profile island shape-with the overlapping hole area of the step removed-defines a reduced layer island polygon shape that becomes the final layer island profile shape.
<!-- image -->If no layer profile is defined, the layer profile is assumed to be equal to the step profile of the step in which the layer is defined. It is not necessary to define a layer profile if the step profile defines the shape of each layer. See '<step_name>/profile (Outline Shape of Step)' on page 141.
The profile file is a features file defining a single surface feature. Surface features are defined as described in '<layer_name>/features (Graphic Features)' on page 170.
Example of a Layer Profile File
UNITS=INCH ID=58 # #Num features # F 1 # #Layer features # S P 0 OB 5.688950787402 7.475950787402 I OS 5.688950787402 7.122049212598 OS 4.936950787402 7.122049212598 OS 4.936950787402 3.838950787402 OS 5.530950787402 3.838950787402 OS 5.530950787402 3.759950787402 OS 5.786950787402 3.759950787402 OS 5.786950787402 2.303049212598 OS 5.668950787402 2.303049212598 OS 5.668950787402 0.885950787402 OS 5.786950787402 0.885950787402 OS 5.786950787402 -0.290950787402 OS 4.566950787402 -0.290950787402 OS 4.566950787402 -0.554950787402 OS 4.173049212598 -0.554950787402 OS 4.173049212598 -0.290950787402 OS 1.731950787402 -0.290950787402 OS 1.731950787402 -0.633950787402 OS -0.542950787402 -0.633950787402 OS -0.542950787402 2.456950787402 OS 0.957049212598 2.456950787402 OS 0.957049212598 2.834950787402 OS 1.035049212598 2.834950787402 OS 1.035049212598 3.898049212598 OS 0.957049212598 3.898049212598 OS 0.957049212598 5.511950787402 OS 1.035049212598 5.511950787402 OS 1.035049212598 5.984049212598 OS 0.957049212598 5.984049212598 OS 0.957049212598 6.311049212598 OS -1.113950787402 6.311049212598 OS -1.113950787402 7.475950787402 OS 5.688950787402 7.475950787402 OE SE
<layer_name>/tools (Drill Tools)
This file contains the tools table of a drill layer, initially created during input.
| tools (Drill Tools) | tools (Drill Tools) | |-----------------------|-----------------------| | Type | Structured Text |
| tools (Drill Tools) | tools (Drill Tools) | |-----------------------|------------------------------------------------------------------| | Compression | None | | Path | <product_model_name>/steps/<step_name>/layers/<layer_name>/tools | | UNITS | The UNITS directive is required. |
The file contains global parameters and a TOOLS array structure.
<!-- image -->Global Parameters for Drill Tools
These are the global parameters.
| Field | Explanation | |-------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | THICKNESS | Board thickness (mils or mm) (Obsolete). Where it is necessary to describe board thickness, it is derived from the step attribute .board_thickness. See 'ODB++ System Attributes - Alphabetical List' on page 215. | | USER_PARAMS | Free text. |
Tools array structure
This is the tools array structure.
| Field | Explanation | |------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------| | NUM | Tool number. | | TYPE | One of these values: PLATED, NON_PLATED, VIA. | | TYPE2 | Legal values depend on the value of TYPE: • TYPE=PLATED -STANDARD or PRESS_FIT • TYPE=NON_PLATED -STANDARD • TYPE=VIA -STANDARD, PHOTO, or LASER (Default=STANDARD). | | MIN_TOL, MAX_TOL | Allowed tolerances (mils or microns). | | BIT | Drill bit string. |
| Field | Explanation | |-------------|-----------------------------------------------------------------------------------------------------------------------------------------------------| | FINISH_SIZE | Required drill size in the finished board. (mils or microns). If this value was not set, the value should be -1. | | DRILL_SIZE | Drill tool size used by the drilling machine to achieve the required finished hole size after production of the board (mils or microns) (optional). |
Example of a tools file
UNITS=INCH THICKNESS=62.5 USER_PARAMS=method25 TOOLS { NUM=1 TYPE=VIA TYPE2=STANDARD MIN_TOL=0 MAX_TOL=0 BIT= FINISH_SIZE=11.5 DRILL_SIZE=13.5 } TOOLS { NUM=2 TYPE=PLATED TYPE2=STANDARD MIN_TOL=0 MAX_TOL=0 BIT= FINISH_SIZE=15 DRILL_SIZE=19 }
Appendix A Standard ODB++ Symbols
A symbol is one of the geometric primitives supported by ODB++ described here, or a combination of them. They are defined by the parameters: width, height, radius, diameter, spokes, gap, angle, size and corner. The corners of rounded or chamfered rectangles or thermals are specified in ascending order-moving counter-clockwise-starting from the top-right corner.
For an example of a symbol with chamfered corners, see 'Rounded/Chamfered Rectangles' on page 212.
All symbols described in this section are standard (system) symbols. User defined symbols are defined as described in 'symbols (User-Defined Symbols)' on page 94.
| Basic Standard Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 195 | |-----------------------------------------------------------------------------------------------------------------------------------|-------| | Symbols Suitable for Solder Stencil Design. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 210 | | Other Symbol Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 212 | | Rotated Standard Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 212 | | Rounded/Chamfered Rectangles. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 212 | | Corner Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 213 | | Obsolete Symbols. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 213 |
Basic Standard Symbols
These are the basic standard symbols.
<!-- image -->| Symbol Name | Example | Parameters | |---------------|-----------|-------------------------| | Round | | r<d> d -Circle diameter |
<!-- image --> <!-- image --> <!-- image --> <!-- image --> <!-- image --> <!-- image --> <!-- image -->| Symbol Name | Example | Parameters | |-------------------------------|-----------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Square Thermal (Open Corners) | | s_tho<od>x<id>x<angle>x<num_s pokes>x<gap> od -Outer diameter id -Inner diameter angle -Gapangle from 0 degrees in increments of 45 degrees num_spokes -Number of spokes: 1, 2, or 4 gap -Size of spoke gap od and id control the air gap (size of laminate separation). | | Line Thermal | | s_thr<os>x<is>x<angle>x<num_sp okes>x<gap> os -Outer size is -Inner size angle -Gap angle always 45 degrees num_spoke -number of spokes always 4 gap -Size of spoke gap Ends of lines are rounded with diameter (os-is)/2. |
<!-- image -->| Symbol Name | Example | Parameters | |----------------------|-----------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Square-Round Thermal | | sr_ths<os>x<id>x<angle>x<num_s pokes>x<gap> os -Outer size id -Inner diameter angle -Gap angle from 0 degrees num_spokes -Number of spokes gap -Size of spoke gap os and id control the air gap (size of laminate separation). | | Rectangular Thermal | | rc_ths<w>x<h>x<angle>x<num_sp okes>x<gap>x<air_gap> w -Outer width h -Outer height angle -Gap angle from 0 degrees; in multiples of 45 degrees num_spokes -Number of spokes gap -Size of spoke gap air_gap -Size of laminate separation |
<!-- image --> <!-- image --> <!-- image -->| Symbol Name | Example | Parameters | |---------------------|-----------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Oval Thermal | | o_ths<ow>x<oh>x<angle>x<num_ spokes>x<gap>x<lw> ow -Outer width oh -Outer height angle -Gap angle from 0 degrees num_spokes -Number of spokes gap -Size of spoke gap lw -Line width | | Oblong Thermal | | oblong_ths<ow>x<oh>x<angle>x< num_spokes>x<gap>x<lw>x<r|s> ow -Outer width oh -Outer height angle -For 2 spokes, angle can be 0 or 90 degrees; for 4 spokes, angle can be 0, 45, or 90 degrees. num_spokes -Number of spokes gap -Size of spoke gap lw -Line width r|s -Support for rounded or straight corners | | Home Plate (hplate) | | hplate<w>x<h>x<c> hplate<w>x<h>x<c>x<ra>x<ro> w -Horizontal side h -Vertical side c -Cut size (c<=w) ra -Corner radius (acute angle) (optional) ro -Corner radius (obtuse angle) (optional) ra and ro must meet the restrictions in 'Symbols Suitable for Solder Stencil Design' on page 210. |
<!-- image -->| Symbol Name | Example | Parameters | |------------------------------------------|-----------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Inverted Home Plate (rhplate) | | rhplate<w>x<h>x<c> rhplate<w>x<h>x<c>x<ra>x<ro> w -Horizontal side h -Vertical side c -Cut size (c<w) ra -Corner radius (acute angle) (optional) ro -Corner radius (obtuse angle) (optional) ra and ro must meet the restrictions in 'Symbols Suitable for Solder Stencil Design' on page 210. | | Flat Home Plate (fhplate) | | fhplate<w>x<h>x<vc>x<hc> fhplate<w>x<h>x<vc>x<hc>x<ra> x<ro> w -Horizontal side h -Vertical side hc -Horizontal cut size (hc<w) vc -Vertical cut size (vc<h/2) ra -Corner radius (acute angle) (optional) ro -Corner radius (obtuse angle) (optional) ra and ro must meet the restrictions in 'Symbols Suitable for Solder Stencil Design' on page 210. | | Radiused Inverted Home Plate (radhplate) | | radhplate<w>x<h>x<ms> radhplate<w>x<h>x<ms>x<ra> w -Horizontal side h -Vertical side (h>(ms + (w-ms)/ 2)/2) ms -Middle curve size (ms <w) ra -Corner radius (optional) ra and ro must meet the restrictions in 'Symbols Suitable for Solder Stencil Design' on page 210. |
<!-- image -->| Symbol Name | Example | Parameters | |------------------------------|----------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Radiused Home Plate (dshape) | | dshape<w>x<h>x<r> dshape<w>x<h>x<r>x<ra> w -Horizontal side h -Vertical side r -Relief (r<=w or (r=w and h=2*w)) ra -Corner radius (optional) ra and ro must meet the restrictions in 'Symbols Suitable for Solder Stencil Design' on page 210. | | Cross (crossx[r|s]) | Variations: If the cross point is located outside the skeleton of the segment, the resulting indentation is ignored. | The cross symbol consists of two intersecting orthogonal line segments. The cross point is at the intersection of their respective skeletons. cross<w>x<h>x<hs>x<vs>x<hc>x< vc>x[r|s] cross<w>x<h>x<hs>x<vs>x<hc>x< vc>x[r|s]<ra> w -Horizontal side h -Vertical side hs -Horizontal line width (hs<h) vs -Vertical line width (vs<w) hc -Horizontal cross point vc -Vertical cross point r|s -Line style (round or square) ra -Inside corner radius (limited by the lengths of the line segments) |
<!-- image -->| Symbol Name | Example | Parameters | |------------------------------|------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Dogbone (dogbonex[r|s]) | Variation: | dogbone<w>x<h>x<hs>x<vs>x<hc >x[r|s] dogbone<w>x<h>x<hs>x<vs>x<hc >x[r|s]x<ra> w -Horizontal side h -Vertical side hs -Horizontal line width (hs<h/2) vs -Vertical line width (vs<w) hc -Horizontal cross point r|s -Line style (round/square) ra -Corner radius (must be less than the whichever value is smaller: hs or vs/2) | | D-Pack (dpack) | | The individual pads of dpack can be straight or rounded, depending on the corner radius (ra) parameter. dpack<w>x<h>x<hg>x<vg>x<hn> x<vn> dpack<w>x<h>x<hg>x<vg>x<hn> x<<vn>x<ra> w -Horizontal side h -Vertical side hg -Horizontal gap (hg<h) vg -Vertical gap (vg<v) vn -Columns number hn -Rows number ra -Corner radius (ra<=[the smaller of hs and vs]/2) The horizontal and vertical sides of an individual pad within the D-Pack are calculated. They are not user- defined. They must be greater than zero. • hs=w-hg·(hn-1)/hn • vs=h-(vg·(vn-1))/vn |
<!-- image -->Symbols Suitable for Solder Stencil Design
Several symbols were added to fulfill the requirements for effective stencil design manufacture.
These symbols are suitable for solder stencil design:
- Home Plate (hplate)
- Inverted Home Plate (rhplate)
- Flat Home Plate (fhplate)
- Radiused Inverted Home Plate (radhplate)
- Radiused Home Plate (dshape)
- Cross (cross...[r|s])
- Dogbone (dogbone...r|s)
- D-Pack (dpack)
Most of these symbols can be created with either straight or rounded corners. If you specify a corner radius to be used for rounding the symbol, corners can be rounded only if the rounded part of one corner would not meet the rounded part of an adjacent corner.
<!-- image -->The diagram shows how two corners of a symbol are to be rounded:
Ra - Perpendicular radius of corner a.
Rb - Perpendicular radius of corner b.
C - Distance from perpendicular radius to corner a.
D - Distance from perpendicular radius to corner b.
L - Length of the side connecting the two corners.
Aa, Ab - Angles at corners a and b.
If L > C + D, the symbol can be created with rounded corners.
This restriction can be expressed as: L > Ra/tan(Aa/2) + Rb/tan(Ab/2).
Other Symbol Information
| Symbol topics are discussed. | | |-----------------------------------------------------------------------------------------------------------------------------------------|-----| | Rotated Standard Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 212 | | Rounded/Chamfered Rectangles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 212 | | Corner Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 213 |
Rotated Standard Symbols
Prior to ODB++ version 7.0, pads and text could be rotated only in increments of 90 degrees. Angles other than 0, 90, 180 or 270 were considered user-defined symbols; and that increased the amount of feature data stored in the product model.
Rotation of pads and text at any angle is now allowed.
Note
- [ ] Rotation is clockwise.
Rounded/Chamfered Rectangles
The corners of rounded/chamfered rectangles are specified in ascending order counterclockwise, starting from the top-right corner. If all corners are to be rounded/chamfered, there is no need to specify corners after the corner radius parameter. A rectangle with all corners chamfered is indicated by: rect100x50xc8-100=width, 50=height, 8=corner radius.
<!-- image -->A rectangle with only the top right corner chamfered is indicated by: rect100x50xc8x12 ( 12 indicates top right and top left corners).
<!-- image -->These are the standard symbols whose corners can be rounded or chamfered:
- Rounded Rectangle
- Chamfered Rectangle
- Rounded Square Donut
- Rounded Rectangle Donut
- Rounded Square Thermal
- Rounded Square Thermal (Open Corners)
- Rounded Rectangle Thermal
Corner Size
The standard Octagon symbol corner size is the distance between the bounding box corner and the vertex.
<!-- image -->Obsolete Symbols
These symbols are obsolete.
<!-- image -->Appendix B System Attributes
Attributes are user-defined properties that add intelligence to the ODB++ data and facilitate automation.
See 'ODB++ Attributes' on page 27.
All measurable values are interpreted according to the UNITS directive in the corresponding attribute definition file. See 'Units of Measurement' on page 23.
For information on the sysattr file to which each attribute belongs, see 'ODB++ System Attributes by Class' on page 271.
For an attribute that requires a units of measurement definition, this is indicated in the description. Attributes without a units of measurement definition are expressed using the units of measurement of the product model.
| ODB++ System Attributes - Alphabetical List . . . . . . . . . . . . . . . . . . . . . | 215 | |--------------------------------------------------------------------------------------------------------------|-------| | ODB++ System Attributes by Class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 271 | | Product (sysattr) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 271 | | DFM (sysattr.dfm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 276 | | Fabrication (sysattr.fab) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 279 | | Assembly (sysattr.assy) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 281 | | Test (sysattr.test). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 283 | | Generic (sysattr.gen). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 284 |
ODB++ System Attributes - Alphabetical List
These are the system attributes.
| Attribute | Type | Entity | Description | Display Name | |------------------------------------------|---------|----------|-------------------------------------------------------------------------------------------------------------------|--------------------------------------| | .all_eda_layers | Text | Step | (0 to 1000 characters) This attribute consists of a list of all the layers in the current EDA design (not ODB++). | All EDA Layers | | .allowed_to_rem ove_non_functio nal_pads | Boolean | Step | Indicates whether it is allowed to remove nonfunctional pads. | Allowed to Remove nonfunctional Pads |
| Attribute | Type | Entity | Description | Display Name | |---------------------------|---------|----------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| | .aoi_cpbm | Integer | Feature | (0 to 255) (Obsolete) | .aoi_cpbm | | .aoi_cpcu | Integer | Feature | (0 to 255) (Obsolete) | .aoi_cpcu | | .aoi_drbm | Integer | Feature | (0 to 255) (Obsolete) | .aoi_drbm | | .aoi_drcu | Integer | Feature | (0 to 255) (Obsolete) | .aoi_drcu | | .aoi_value | Integer | Feature | (0 to 255) (Obsolete) | .aoi_value | | .ar_pad_drill_bottom max | Float | Feature | (-10 to 1000) Assigned to a drill to define the maximum annular ring size between the drill and the copper of the bottom layer of the drill span. (UNITS=MIL_MICRON) | Max Pad AR Drill Bottom | | .ar_pad_drill_bottom min | Float | Feature | (-10 to 1000) Assigned to a drill to define the minimum annular ring size between the drill and the copper of the bottom layer of the drill span. (UNITS=MIL_MICRON) | Min Pad AR Drill Bottom | | .ar_pad_drill_inner max | Float | Feature | (-10 to 1000) Assigned to a drill to define the maximum annular ring size between the drill and the copper of an inner layer in the drill span. (UNITS=MIL_MICRON) | Max Pad AR Drill Inner | | .ar_pad_drill_inner min | Float | Feature | (-10 to 1000) Assigned to a drill to define the minimum annular ring size between the drill and the copper of an inner layer in the drill span. (UNITS=MIL_MICRON) | Min Pad AR Drill Inner |
| Attribute | Type | Entity | Description | Display Name | |--------------------------|--------|----------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------| | .ar_pad_drill_top_m ax | Float | Feature | (-10 to 1000) Assigned to a drill to define the maximum annular ring size between the drill and the copper of the top layer of the drill span. (UNITS=MIL_MICRON) | Max Pad AR Drill Top | | .ar_pad_drill_top_mi n | Float | Feature | (-10 to 1000) Assigned to a drill to define the minimum annular ring size between the drill and the copper of the top layer of the drill span. (UNITS=MIL_MICRON) | Min Pad AR Drill Top | | .ar_sm_drill_bottom _max | Float | Feature | (-10 to 1000) Assigned to a drill piercing the bottom layer, to define the maximum annular ring size between the drill and the soldermask on the bottom layer. (UNITS=MIL_MICRON) | Max SM AR Drill Bottom | | .ar_sm_drill_bottom _min | Float | Feature | (-10 to 1000) Assigned to a drill piercing the bottom layer, to define the minimum annular ring size between the drill and the soldermask on the bottom layer. (UNITS=MIL_MICRON) | Min SM AR Drill Bottom | | .ar_sm_drill_top_ma x | Float | Feature | (-10 to 1000) Assigned to a drill piercing the top layer, to define the maximum annular ring size between the drill and the soldermask on the top layer. (UNITS=MIL_MICRON) | Max SM AR Drill Top |
| Attribute | Type | Entity | Description | Display Name | |------------------------|--------|----------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------| | .ar_sm_drill_top_mi n | Float | Feature | (-10 to 1000) Assigned to a drill piercing the top layer, to define the minimum annular ring size between the drill and the soldermask on the top layer. (UNITS=MIL_MICRON) | Min SM AR Drill Top | | .ar_sm_pad_bottom_ max | Float | Feature | (-10 to 1000) Assigned to a drill piercing the bottom layer, to define the maximum annular ring size between the drilled pad of the bottom layer and the soldermask above. (UNITS=MIL_MICRON) | Max SM AR Bottom | | .ar_sm_pad_bottom_ min | Float | Feature | (-10 to 1000) Assigned to a drill piercing the bottom layer, to define the minimum annular ring size between the drilled pad of the bottom layer and the soldermask above. (UNITS=MIL_MICRON) | Min SM AR Bottom | | .ar_sm_pad_top_ma x | Float | Feature | (-10 to 1000) Assigned to a drill piercing the top layer, to define the maximum annular ring size in between the drilled pad of the top layer and the soldermask above. (UNITS=MIL_MICRON) | Max SM AR Top | | .ar_sm_pad_top_min | Float | Feature | (-10 to 1000) Assigned to a drill piercing the top layer, to define the minimum annular ring size in between the drilled pad of the top layer and the solder mask above. (UNITS=MIL_MICRON) | Min SM AR Top |
| Attribute | Type | Entity | Description | Display Name | |------------------------|---------|----------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------| | .area_name | Text | Feature | (0 to 64) Assigned to surface features that are drawn in a process map layer. A process map layer is used in assembly analysis for determining the process type used in the location at which a measurement is found. | DFx Area Name | | .array_with_rotation | Boolean | Step | (YES, NO) (default=NO) If YES, this step is a multi- panel array, with the same panel possibly appearing in 180-degree rotation to itself | Array with Rotation | | .artwork | Text | Feature | (0-1000) Indicating to which entity the feature belongs (component, package, net, board) | Feature Source | | .assembly_proc_bott om | Text | Step | (0 to 20) Default assembly process for the bottom side, to be used when there is no specific area defined in the process map layer (or no process map layer at all) | Assembly Process (Bottom) | | .assembly_proc_top | Text | Step | (0 to 20) Default assembly process for the top side, to be used when there is no specific area defined in the process map layer (or no process map layer at all). | Assembly Process (Top) | | .axi_direction | Option | Step | (Left2Right; Top2Bottom; Right2Left; Bottom2Top) Defines the angle at which a board is inserted into a 5DX machine. Values are translated as 0, 90, 180, 270 degrees. | Assembly X-Ray Inspection Direction |
| Attribute | Type | Entity | Description | Display Name | |----------------------------------|--------|---------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------| | .backdrill_penetrate_ stop_layer | Text | Layer | (0-64) Used by Backdrill Analysis to indicate the layer not to be penetrated during the backdrill process. | Backdrill not Penetrate Layer Name | | .bit | Text | Feature | (0-64) Contains the drill designator that is to be used for each tool. | Drill Designator | | .board_mark | Option | Feature | (bbm, gpm) In Vi-Technology output, this controls whether a step or a panel needs to be inspected: bbm -this feature is a bad board mark. Skip inspection of the step. gpm -this feature is a good panel mark. The panel can be accepted for printing without scanning its steps for bad board marks. | VI Tech. Board Mark | | .board_thickness | Float | Product Model | (0.0 to 10.0; default=0.0) Total thickness of the board. (UNITS=MIL_MICRON) | Board Thickness | | .bond_name | Text | Feature | Name of the wire bond. | Name of Wire Bond | | .bonding_profile | Text | Feature | Name of the bonding profile. | Bonding profile |
| Attribute | Type | Entity | Description | Display Name | |------------------------------|---------|-------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------| | .break_away | Boolean | Symbol | (Default=NO) Assigned to a symbol that represents a break-away that can be inserted into any line or arc of the rout path. When adding a break_away symbol through dimensions, it automatically adjusts to the line or arc angle, breaks that feature (in the breaking points defined in that symbol with the .brk_pnt attribute), and adds all the necessary connections and dimensions. | Break Away | | .brk_point | Boolean | Feature | (YES, NO) Assigned to a pad or a dpoint in a break-away symbol (that was given the attribute .break_away ).Whenadding the break-away to the line/ arc in the layer, through dimensions, the line/arc is broken at the connection point with the dpoint that has the .brk_point attribute. In each break-away symbol there should be two points with this attribute. | Rout Break Point | | .bulk_resistivity | Float | Layer | (0-10000; Default-0) The nano-ohmic resistance of the semiconductor material. (UNITS=NANO_OHM) | Bulk Resistivity (nano-ohm-m) | | .cad_local_footprint _change | Boolean | Comp.; Pkg. | (Default=NO) Indicates whether there has been a local change to a pad code in the local design. | CADStar Pad Change |
| Attribute | Type | Entity | Description | Display Name | |-------------------------|---------|-------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------| | .cad_package_name | Text | Comp. | (0-10000) Contains the full CAD package name of a Cadstar component. This name can be longer than the Valor package name which is limited to 64 characters. | CADStar Package Name | | .cad_part_override | Text | Comp.; Pkg. | (0-64) Assigns component properties in accordance with data received from the ASSY_PN_OVERRIDE property. | CAD Part Varient Support | | .center_fiducial | Boolean | Comp.; Pkg. | (Default=NO) Specifies component is expected to have a fiducial at its center. | Center Fiducial Required | | .centroid_correction _x | float | Comp; Pkg | (-100 to 100) Specifies the x-offset from the CAD centroid to the calculated package centroid. | Centroid Correction X | | .centroid_correction _y | float | Comp; Pkg | (-100 to 100) Specifies the y-offset from the CAD centroid to the calculated package centroid. | Centroid Correction Y |
| Attribute | Type | Entity | Description | Display Name | |--------------|--------|----------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------| | .color | Text | Feature; Comp. | (0 to 1000 for each color) Can be attached to any feature or component to define the color to be used in plotting a layer in HPGL-1 or 2. The format is rrggbb (where r =red, g =green, b =blue). White -.color= ' 999999' Black -.color= ' 000000' Red -.color= ' 990000' Green -.color= ' 009900' Yellow -.color= ' 009999' Blue -.color= ' 000099' Magenta -.color= ' 990099' Cyan -.color= ' 999900' | HPGL Output Color | | .comment | Text | Product Model; Step; Layer; Wheel; Symbol; Buildup | (0 to 500) Used for general textual comments. | Comment | | .comp | Option | Feature | (none; right; left) For a chained feature, this attribute sets the offset of the cutting tool from the rout path. Three options: • None-in center of the rout path • Left-to the left of the rout path in the direction of cutting • Right-to the right of the path | Rout Compensate | | .comp_height | Float | Feature; Comp.; Pkg | (0.0 to 10.0) Stores the height of the component above the board surface. (UNITS=INCH_MM) | Height |
| Attribute | Type | Entity | Description | Display Name | |-------------------|---------|----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------| | .comp_height_area | Integer | Feature; Comp. | (0.0 to 1000000.0; default=0) This attribute is used to assign the same ID to a component under which there is an area with space for a shorter component, and to the feature that defines the area. | Allegro Height ID | | .comp_height_max | Float | Comp.; Pkg. | (0.0-10.0) The height of the tallest package (in the CPN package of alternate MPNs) above the board surface. (UNITS=INCH_MM) | Maximal Height | | .comp_htol_minus | Float | Comp.; Pkg. | (0.0-10.0) Contains the minus tolerance for component height, used for calculation of plug-in boards. (UNITS=INCH_MM) | Height Tolerance Minus | | .comp_htol_plus | Float | Comp.; Pkg. | (0.0-10.0) Contains the plus tolerance for component height, used for calculation of plug-in boards. (UNITS=INCH_MM) | Height Tolerance Plus | | .comp_ign_spacing | Boolean | Comp.; Pkg. | (Default=NO) This attribute, when set, disables spacing checks on a component during assembly analysis. It is used for printed components that have no actual body | Ignore during Spacing Analysis | | .comp_ignore | Boolean | Comp.; Pkg. | (Default=NO) Determines whether the component is to be ignored when calculating statistics, or during certain operations, such as analysis. | Ignore |
| Attribute | Type | Entity | Description | Display Name | |------------------|--------|-------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------| | .comp_mount_type | Option | Comp.; Pkg. | (Other; SMT; THMT; PressFit) Indicates whether the component is a surface mount, through-hole mount, press-fit or other. (SMT;THMT;PRESSFIT) | Mount Type | | .comp_name | Text | Comp. | Name of the die component on the HDI technology layer. | Name of Die Component | | .comp_polarity | Option | Comp.; Pkg. | • POLARIZED, has a specific pin designated as pin #1. • NON_POLARIZED has no specific pin #1. | Polarity | | .comp_type | Option | Comp.; Pkg. | This attribute represents the type of the component. Options are: axial; bga; cbga; cob; dip; discrete; discrete402; discrete603; label; pga; pihconn; pihmisc; plcc; pqfp; printed; qfp; radial; sip; smtconn; smtmisc; socket; soic; soj; sop; sot; tab; tqfp; tsoic; tsop | Type I | | .comp_type2 | Option | Comp.; Pkg. | Options are: axial; axial-large; bga; cbga; cob; csp; dip; dip300; dip600; discrete; discrete201; discrete402; discrete603; electro-mech; flipchip; label; lcc; lqfp; pfconn; pga; pihconn-inline; pihconn-rt-angle; pihmisc; pih-polar; plcc; pqfp; printed; qfp; radial; radial- tall; sip; smtconn; smtelect- mech; smtmisc; smtmixedconn; smtpolar; socket; soic; soj; solderable-mech; sop-ssop; sot; tab; tqfp; tsoic; tsop; tsop-tssop | Type II |
| Attribute | Type | Entity | Description | Display Name | |--------------------|---------|--------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------| | .comp_variant_list | Text | Comp.; Pkg. | (0-1000) Consists of a list of variants where a component is used. The list contains variant names separated by a colon (:). See 'Component Variants' on page 41. | Variant List | | .comp_weight | Float | Comp.; Pkg. | (0.0-1000.0) Stores the weight of the component (in accordance to its Units of Measurement) for the purpose of the total weight calculation. | Weight | | .copper_weight | Float | Layer | (0.0 to 1000.0; default=1.0) The weight of copper according to its Units of Measurement. | Copper Weight | | .critical_net | Boolean | Feature; Net | (YES, NO) Specifies critical nets. | SQA Critical Net | | .critical_tp | Boolean | Feature | (YES, NO) Assigned to the mid-point of a netlist to force it to become a testpoint. If both .non_tp and .critical_tp are assigned to the same point, .critical_tp takes precedence and the mid point is tested. In case of a drilled feature the attribute must be added to the drill hole. | Netlist Critical Midpoint Output | | .cu_base | Boolean | Layer | (Default=NO) (Obsolete) Indicates whether the via holes created by a drill layer are filled (rather than plated). This attribute is only suitable for drill layers. | Vias Need Cu |
| Attribute | Type | Entity | Description | Display Name | |------------------|---------|---------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------| | .current_variant | Text | Step | (0-100) Consists of the name of the current variant for a step. See 'Component Variants' on page 41. | Current Variant | | .customer | Text | Product Model | (0-100) This attribute can store the name of the customer for whom the product model was created. | Customer | | .cut_line | Integer | Feature | (0-100000; default=0) Assigned to lines added in the creation of film layers by the film optimization algorithm. The attribute is given to three kinds of lines: • frame of the film • cutting lines inside the film • frame of each layer inside the film. | Film Optimization Cut Line | | .data_source | Text | Product Model; Step | (0-100) The source of the data. For example, Cadence, Mentor. | Data Source | | .desc1....10 | Text | Comp.; Pkg. | (0-1000) Storage for tenBOM description fields into corresponding ten description attributes. | General Description 1....10 | | .design_center | Text | Product Model; Step | (0-100) The design center from which the product model originated. | Design Center | | .design_origin_x | Integer | Product Model | (-254000000 to 254000000) Defines the design origin x coordinate. | Design X Origin | | .design_origin_y | Integer | Product Model | (-254000000 to 254000000) Defines the design origin y coordinate. | Design Y Origin |
| Attribute | Type | Entity | Description | Display Name | |----------------------|--------|-------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------| | .device_style | Text | Comp.; Pkg. | (0-64) This attribute is an enhancement of .device_type and is used to store the style of the component as defined in GenCAD (such as, NPN, PNP, NFET, PFET, NJFET, PJFET, TTL, CMOS and ECL). | Device Style | | .device_type | Text | Comp.; Pkg. | (0-64) Stores the type of the component as defined in the device (such as,RES,VRES, DIODE, ZENER, LOGIC, SWITCH, CONN, etc.). | Device Type | | .device_value | Text | Comp.; Pkg. | (0-64) Stores the electrical value of a component. | Device Electrical Value | | .device_value_ntol | Float | Comp.; Pkg. | 0-1000000; default=0.0) This is a real value expressing the percent of the value to use as a tolerance (negative tolerance). This is used for all devices. Range of characters: all floating point numbers. | Device Value Negative Tolerance | | .device_value_ptol | Float | Comp.; Pkg. | (0-1000000; default=0.0) This is a real value expressing the percent of the value to use as a tolerance (positive tolerance). This is used for all devices. | Device Value Positive Tolerance | | .dielectric_constant | Float | Layer | (0.0 to 1000.0; default=0.0) The ratio of the field without dielectric (Eo) to the net field (E) with dielectric. It is unitless and has a range value of 1 for metals. Typical values are 4 and 5. | Dielectric Constant (ER) |
| Attribute | Type | Entity | Description | Display Name | |-----------------------|---------|---------------|---------------------------------------------------------------------------------------------------------------------|---------------------------------| | .diff_pair | Text | Net | (0 to 64) Differential pair name associating two nets that must be routed together. | Differential Pair | | .dpair_gap | Float | Net | (0.0 to 10.0) Spacing gap value specifying the spacing between differential pair nets. (UNITS=INCH_MM) | Differential Pair Spacing | | .drc_add_rad | Integer | Mania_ AOI | (0 to 100; default=2) (Obsolete) | Enlarge By | | .drc_assembly_lyrs | Option | Feature | (Top; Bottom; Both) Specifies whether the keepout/keepin area applies to Top, Bottom, or Both component layers. | Assigned Area to Component Side | | .drc_bend_keepout | Boolean | Feature | NOT USED | FLEX Bend Keepout Area | | .drc_board | Boolean | Feature | (YES, NO) Assigned to a DRC area defined for the whole board. | Analysis Board Area | | .drc_comp_height | Boolean | Feature | (YES, NO) Assigns component height restriction to a keepin/ keepout area. | Component Height for Area | | .drc_comp_height_l yr | Text | Product Model | (0 to 64) Stores name of document layer in which all component height restriction keepin/ keepout areas are stored. | Comp. Height Restriction Layer | | .drc_comp_keepin | Boolean | Feature | (YES, NO) Defines an area as the board's component placement keepin boundary. | Component Keep In | | .drc_comp_keepin_l yr | Text | Product Model | (0 to 64) Stores name of document layer in which all component keepin areas are stored. | Component Keep In Layer |
| Attribute | Type | Entity | Description | Display Name | |------------------------|---------|---------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------| | .drc_comp_keepout | Boolean | Feature | (YES, NO) Defines an area as the board's component placement keepout boundary. | Component Keep Out | | .drc_comp_keepout_ lyr | Text | Product Model | (0 to 64) Stores name of document layer in which all component keepout areas are stored. | Component Keep Out Layer | | .drc_etch_lyrs | Text | Feature | (0 to 1000) Value=layer names separated by semi-colons (;). User-defined attribute for user to specify name of layers in which to activate keepin/keepout areas. For example, when .drc_etch_lyrs=pg1;pg2 , this enables you to select/ highlight (on the relevant document layer) keepin/ keepout areas that are active in layers pg1 , pg2 . The attributes: .drc_etch_lyrs_bit and .drc_etch_lyrs must both specify the same layers. If there is a discrepancy between the two, then .drc_etch_lyrs_bit is the determining attribute. | DFx Area Layers by Name | | .drc_etch_lyrs_all | Boolean | Feature | (YES, NO) Defines a keepin/keepout area as effective on all layers. | DFx Area All Layers |
| Attribute | Type | Entity | Description | Display Name | |-----------------------|---------|---------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------| | .drc_etch_lyrs_bit | Text | Feature | (0 to 64) Values=string consisting of '0' and '1' characters. Allows the keepin/keepout area to apply only to specified board layers. The attribute's length is equal to the number of board layers. 0=ignore layer, 1=activate areas in that layer | DFx Area Selected Layers | | .drc_max_height | Float | Feature | (0.0 to 10.0) Stores the maximum height of components to be allowed in a height restriction area (area with .drc_comp_height attribute). (UNITS=INCH_MM) | Maximum Height for Component | | .drc_mech | Boolean | Feature | (Obsolete) | Analysis Mechanical Area | | .drc_min_height | Float | Feature | (0.0 to 10.0) Stores the minimum height of components to be allowed in a height restriction area (area with .drc_comp_height attribute). (UNITS=INCH_MM) | Minimum Height for Component | | .drc_min_space | Integer | Mania_ AOI | (1 to 100; default=5) (Obsolete) | Min Spacing | | .drc_min_width | Integer | Mania_ AOI | (1 to 100; default=7) (Obsolete) | Min Track Width | | .drc_pad_keepout | Boolean | Feature | (YES, NO) Specifies area to be used as pads keepout boundary. | Pad Keep Out | | .drc_pad_keepout_ly r | Text | Product Model | (0 to 64) Stores name of document layer in which all pad keepout areas are stored. Default as defined in the drc_pad_keepout configuration parameter. | Pad Keep Out Layer |
| Attribute | Type | Entity | Description | Display Name | |-------------------------|---------|---------------|--------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| | .drc_plane_keepout | Boolean | Feature | (YES, NO) Specifies area to be used as planes keepout boundary | Plane Keep Out | | .drc_plane_keepout_ lyr | Text | Product Model | (0 to 64) Stores name of document layer in which all plane keepout areas are stored. | Plane Keep Out Layer | | .drc_ref_des | Text | Feature | (0 to 100) Assigned to DRC areas defined for components. | Reference Designator | | .drc_route_keepin | Boolean | Feature | (YES, NO) Specifies areas to be used as the rout keepin boundary (rout=lines, arcs, vias, pads and surfaces on signal and/or power and ground layers). | Route Keep In | | .drc_route_keepin_l yr | Text | Product Model | (0 to 64) Stores name of document layer in which all rout keepin areas are stored. | Route Keep In Layer | | .drc_route_keepout | Boolean | Feature | Specifies areas to be used as the rout keepout boundary (rout=lines, arcs, vias, pads and surfaces on signal and/or power and ground layers). | Route Keep Out | | .drc_route_keepout_ lyr | Text | Product Model | (0 to 64) Stores name of document layer in which all rout keepout areas are stored. | Route Keep Out Layer | | .drc_tp_keepin | Boolean | Feature | Defines areas to be used as testpoint keepin area boundaries. | Testpoint Keep In | | .drc_tp_keepin_lyr | Text | Product Model | (0 to 64) Stores name of document layer in which all testpoint keepin areas are stored. | Testpoint Keep In Layer | | .drc_tp_keepout | Boolean | Feature | Specifies areas to be used as the testpoint keepout boundary. | Testpoint Keep Out |
| Attribute | Type | Entity | Description | Display Name | |-------------------------|---------|---------------|------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------| | .drc_tp_keepout_lyr | Text | Product Model | (0 to 64) Stores name of document layer in which all testpoint keepout areas are stored. | TestpointKeepOut Layer | | .drc_trace_keepout | Boolean | Feature | (YES, NO) Defines areas to be used as trace keepout boundaries (traces=lines and arcs on signal and/or power and ground layers). | Trace Keep Out | | .drc_trace_keepout_l yr | Text | Product Model | (0 to 64) Stores name of document layer in which all traces keepout areas are stored. | Trace Keep Out Layer | | .drc_via_keepout | Boolean | Feature | (YES, NO) Defines areas to be used as vias keepout boundaries. | Via Keep Out | | .drc_via_keepout_ly r | Text | Product Model | (0 to 64) Stores name of document layer in which all vias keepout areas are stored. | Via Keep Out Layer | | .drill | Option | Feature | (plated; non_plated; via) Assigned to hole features in drill layers. It defines the type of the drill and is used extensively during fabrication analysis. | Drill Type | | .drill_flag | Integer | Feature | (0 to 100000; default=0) (Obsolete) | Auto Drill Mgr Flag |
| Attribute | Type | Entity | Description | Display Name | |-------------------------------------------------|---------|----------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------| | .drill_layer_direction | Option | Layer | (top2bottom, bottom2top, any; default=top2bottom) Specifies the drill direction for all drills on a given layer. This information impacts on analysis and potentially on the generation of production tooling information. See START_NAME and END_NAME in 'Fields in the LAYER Array of a Matrix File' on page 65. | Drill Layer Direction | | .drill_noopt | Boolean | Feature | (Obsolete) | Auto Drill No Opt. | | .drill_sr_zero | Option | Feature | (1; 2; 3) (Obsolete) | Auto Drill S and R Offset | | .drill_stage | Option | Feature | (1; 2; 3) (Obsolete) | Auto Drill Mgr Stage | | .dxf_dimension | Boolean | Feature | (YES, NO) Assigned during DXF file input to mark its features as part of a DXF dimension entity. | DXF Dimension | | .eclass_accumulative _parallel_dist_list | Text | Net | (0-255) List of electrical class rules (blank-separated) defining the maximum distance between the two traces of nets considered parallel. | Accum. Parallel Dist. List | | .eclass_accumulative _parallel_max_lengt h_list | Text | Net | (0-255) List of electrical class rules (blank-separated) defining the maximum distance between the two traces of nets considered parallel. | Accum. Parallel Max. Len. List | | .eclass_impedance | Float | Net | (0.0 to 1000.0) Electrical class rule | Impedance |
| Attribute | Type | Entity | Description | Display Name | |-----------------------------------------------|---------|----------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------| | .eclass_individual_p arallel_dist_list | Text | Net | (0-255) List of blank-separated electrical class rules. Defines the separation distance within which two traces are considered parallel. | Individ. Parallel Dist. List | | .eclass_individual_p arallel_max_length_l ist | Text | Net | (0-255) List of electrical class rules (blank-separated). Defines the maximum length that two nets can run parallel to each other. | Individ. Parallel Max. Len. List | | .eclass_individual_p arallel_min_jog_list | Text | Net | (0-255) List of electrical class rules (blank-separated). Defines the distance parallel traces that deviate must maintain the deviation before it is considered a break in parallelism. | Individ. Parallel Min. Jog List | | .eclass_max_stub_le ngth | Float | Net | (0.0 to 100.0) Electrical class rule-high limit of the stub length. (UNITS=MIL_MICRON) | Max. Stub Length | | .eclass_max_via_co unt | Integer | Net | (0 to 1000) Maximal number of vias on the nets. | Max. Via Count | | .eclass_min_stub_le ngth | Float | Net | (0.0 to 100.0) Electrical class rule-low limit of the stub length. (UNITS=MIL_MICRON) | Min. Stub Length | | .eclass_rise_time | Float | Net | (0.0 to 100.0) Electrical class rule specifying the interval of a rising signal transition (low to high) | Rise Time | | .eclass_voltage_swin g | Float | Net | (0.0 to 100.0) Electrical class rule | Voltage Swing |
| Attribute | Type | Entity | Description | Display Name | |-----------------------|---------|----------|-----------------------------------------------------------------------------------------------------|--------------------------------| | .ecmp_layer_tech | Option | Layer | (none, additive, subtractive) Assigns a technology type attribute to an embedded components layer. | Embedded Passive Technology | | .ecmp_max_value | Float | Feature | (0.0 to 1000000.0) Maximum nominal value received at input (its value plus a tolerance). | Embedded Passive Max. Value | | .ecmp_min_value | Float | Feature | (0.0 to 1000000.0) Minimum value received at input (its value minus a tolerance). | Embedded Passive Min. Value | | .ecmp_name | Text | Feature | (0 to 64 characters) Name assigned to an embedded passive feature. | Embedded Passive Name | | .ecmp_type | Option | Feature | (resistor; capacitor) Assigns a component type to an embedded component. | Embedded Passive Type | | .ecmp_value | Float | Feature | (0.0 to 1000000.0) Embedded passive nominal value. For resistors it is the resistance in ohms. | Embedded Passive Nominal Value | | .eco | Text | Step | (0 to 100 characters) The engineering change list. | Engineering Change List | | .eda_define_imp_lin e | Boolean | Feature | Defines lines controlled by impedance. Lines assigned this attribute are not re- routed nor shaved. | Impedance Line- No Edits | | .eda_dimension_id | Integer | Feature | (0 to 100000; default=0) Assigns system-generatedID to dimensions | Embedded Passive Nominal Value |
| Attribute | Type | Entity | Description | Display Name | |-------------------|---------|----------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------| | .eda_layers | Text | Layer | (0 to 1000) Contains the EDA system layer names that compose a physical layer. It is loaded during the direct EDA translation and is used for graphic synchronization with the EDA system. | EDA Layers | | .electrical_class | Text | Net | (0 to 64) Electrical class name associating a net with a set of electrical call rules. Electrical class rules include physical and electrical limitations required to assure and analyze the signal integrity of a high speed net. | Electrical Class | | .et_adjacency | Float | Layer | (0.0 to 1000.0; default=20.0) A distance value (per layer) to use in netlist adjacency calculation for moving probe testers (currently BSL and PROBOT). (UNITS=MIL_MICRON) | Adjacency Distance (ET) | | .et_align | Boolean | Feature | (YES, NO) Determines that a feature will be used as an alignment target for PROBOT output | Probot Alignment Targets |
| Attribute | Type | Entity | Description | Display Name | |-----------------|---------|----------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------| | .extended | Integer | Feature | (-1 to 100000; default=0) Assigned to construction features (lines and pads) added to assist in the generation of a rout path. These features have zero width and are not output to the rout machine as regular features. They are used, for example, as source elements from which to create actual features by dimensions. If the attribute value is not zero then the feature is an extended feature and the decimal value is its serial value in the layer (to be referenced in dimension creation). | Dimension Feature | | .fab_drc | Text | Step | (0 to 20) Stores the default DRC area name. This name is applied when no specific area is defined in the DRC map layer, or no such map layer at all. | Fab DRC | | .feature_ignore | Boolean | Feature | (YES, NO) Copper features with this attribute are ignored in analysis actions. (Currently implemented for rout tests only.) | Copper Feature Ignore | | .feed | Integer | Feature | (0 to 100000; default=0) For a chained feature, this attribute sets the table feed rate when routing. | Rout Feed Rate | | .fiducial_name | Text | Feature | (0 to 64) (Obsolete) | Etec Fiducial Output |
| Attribute | Type | Entity | Description | Display Name | |----------------------|---------|----------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------| | .fiducial_rdlist | Text | Feature | (0-1000) This attribute is assigned local fiducial features. It can consist of a list of REFDES (separated by semicolons); a list of the component/s using this local fiducial. | Local Fiducial Ref.Des. List | | .fill_dx | Float | Symbol | (0.000001 to 50.0; default=0.1) This attribute is used as the default horizontal distance between symbols when the symbol is used for pattern filling. (UNITS=INCH_MM) | Fill Dx | | .fill_dy | Float | Symbol | (0.000001 to 50.0; default=0.1) This attribute is used as the default vertical distance between symbols when the symbol is used for pattern filling. (UNITS=INCH_MM) | Fill Dy | | .foot_down | Boolean | Feature | (Default=NO) (Obsolete) | Auto Rout Footdown | | .fs_direction_bottom | Option | Step | (Right2Left; Left2Right; Top2Bottom; Bottom2Top). Indicates the manufacturing direction the PCB will be going through during the flow solder process. | Flow Solder Direction (Bottom) | | .fs_direction_top | Option | Step | (Left2Right; Right2Left; Top2Bottom; Bottom2Top) Indicates the manufacturing direction the PCB will be going through during the flow solder process. | Flow Solder Direction (Top) | | .full_plane | Boolean | Feature | NOT USED | |
| Attribute | Type | Entity | Description | Display Name | |------------------------|--------|---------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------| | .gencad_device_ntol | Float | Comp.; Pkg. | 0-1000000; default=0.0) This is a real value expressing the percent of the value to use as a tolerance (negative tolerance). This is used for all devices: Range of characters: all floating point numbers. | GENCAD Negative Tolerance | | .gencad_device_ptol | Float | Comp.; Pkg. | (0-1000000; default=0.0) This is a real value expressing the percent of the value to use as a tolerance (positive tolerance). This is used for all devices: | GENCADPositive Tolerance | | .gencad_device_styl e | Text | Comp.; Pkg. | (0-64) This attribute is an enhancement of .gencad_device_type and is used to store the style of the component as defined in GenCAD (such as, NPN, PNP, NFET, PFET, NJFET, PJFET, TTL, CMOS and ECL) | GENCAD Device Style | | .gencad_device_type | Text | Comp.; Pkg. | (0-64) Stores the type of the component as defined in GenCAD (such as, RES, VRES, DIODE, ZENER, LOGIC, SWITCH, CONN, | GENCAD Device Type | | .gencad_device_valu e | Text | Comp.; Pkg. | (0-64) Stores the electrical value of a component. | GENCAD Device Value | | .geometry | Text | Feature | (0 to 500) Contains the name of the padstack that created this feature. | Geometry | | .global_camtek_aois et | Text | Product Model | (0-80) (Obsolete) | Global CAMTEK aoi-set |
| Attribute | Type | Entity | Description | Display Name | |---------------------------|---------|-------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| | .gold_plating | Boolean | Feature | Used during auto- panelization to orient the gold plated area toward the extreme side of the panel. | Gold Plating | | .gold_plating_def ined_by | Option | Step | (GoldMask; SolderMask; N/ A; default=GoldMask). Type of gold plating used. | Gold Plating Defined by | | .guard_comp | Boolean | Comp.; Pkg. | (Default=NO) Assigned to a component that 'guards' other components. If TRUE, this component is considered a 'guard component' (that is, not likely to be knocked off the board accidentally. To be used in future actions.) | Component Guard | | .hatch | Boolean | Feature | (YES, NO) Assigned to hatched planes (filled with lines-hatches- or cross lines-cross- hatch-instead of solid copper). The lines that make up the border and fill the surface are hatches. | Hatch | | .hatch_border | Boolean | Feature | (YES, NO) The lines making up the border of a surface. | Hatch Border | | .hatch_serrated_bord er | Boolean | Feature | (YES, NO) Assigned to features that are added for partial hatch. The difference between regular hatch and partial hatch is that in partial hatch the cells along the border that intersect the border line are filled; the feature(s) that fill these cells are assigned this attribute. | Hatch Serrated Border |
| Attribute | Type | Entity | Description | Display Name | |-----------------------|---------|----------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------| | .hdi_assembly_tech | Option | Layer | (None, WireBond, FlipChip, Hybrid) The attribute defines the type of HDI assembly technology identified in the product model. If None, the special layer is not created. | HDI assembly technology | | .hdi_drc | Text | Step | (0 to 20) Default area name applied to all HDI actions. | HDI Assembly Technology | | .hp3070_comment | Text | Comp.; Pkg. | (0-64) (Obsolete) | HP 3070 Comment | | .hp3070_common_p in | Text | Comp.; Pkg. | (0 to16). (Obsolete) | HP 3070 Common Pin | | .hp3070_contact_pin | Text | Comp.; Pkg. | (0 to16). (Obsolete) | HP 3070 Contact Pin | | .hp3070_device | Text | Comp.; Pkg. | (0 to 16) (Obsolete) | HP 3070 Contact Pin | | .hp3070_fail_msg | Text | Comp.; Pkg. | (0-64) (Obsolete) | HP 3070 Fail Message | | .hp3070_hi_value | Float | Comp.; Pkg. | (0-100000.0; default=0.0) (Obsolete) | HP 3070 High Value | | .hp3070_lo_value | Float | Comp.; Pkg. | (0-100000.0; default=0.0) (Obsolete) | HP 3070 Low Value | | .hp3070_probe_acce ss | Text | Feature; Comp. | (0-64) (Obsolete) | HP 3070 Contact Pin | | .hp3070_seriesr | Float | Comp.; Pkg. | (0-100000.0; default=0.0) (Obsolete) | HP 3070 Series | | .hp3070_test | Boolean | Comp.; Pkg. | (Default=NO) (Obsolete) | HP 3070 Test | | .hp3070_tol_neg | Float | Comp.; Pkg. | (0-100; default=0.0) (Obsolete) | HP 3070 Negative Tolerance | | .hp3070_tol_pos | Float | Comp.; Pkg. | (0-100; default=0.0) (Obsolete) | HP 3070 Positive Tolerance |
| Attribute | Type | Entity | Description | Display Name | |---------------------|---------|-------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------| | .hp3070_type | Text | Comp.; Pkg. | (0-8) (Obsolete) | HP 3070 Type | | .hp3070_value | Text | Comp.; Pkg. | (0-16) (Obsolete) | HP 3070 Value | | .ignore_net | Boolean | Net | (YES, NO) When this attribute is assigned to a net, it is ignored during Testpoint Allocation Analysis. No potential testpoints are assigned, they are not reported in the Nets without Potential TPs category, the Testpoints Allocation Report, or in Total Number of Nets. | Ignore Net During Allocation | | .image_dx .image_dy | Float | Symbol | (-1.0 to 50.0; default=-1.0) These values are set when inputting Image files into the system. They contain the datum point of an Image user-defined symbol entity used to set the datum when performing output back into Image format. These values should not be changed by the user as this can cause data corruption. (UNITS=INCH_MM) | Image Dx Image Dy | | .imp_constraint_id | Integer | Feature | (0 to 2 32 ) For each impedance line bearing this attribute, the system refers to the constraint with the given ID in the impedance constraints table. | Impedance Constraint ID | | .imp_line | Boolean | Feature | Assigned to lines that are impedance-controlled.When set, it prevents the lines from being rerouted or thinned during signal layer optimization. | Impedance Line |
| Attribute | Type | Entity | Description | Display Name | |------------------------|---------|---------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------| | .imp_polyline_id | Integer | Feature | (0 to 2 32 ) Defines a unique ID for all trace segments that are part of the same impedance polyline. | Impedance Polyline ID | | .impedance_test_wid th | Float | Layer | (0 to 1000) Test width of routes used for the provided impedance (UNITS=MIL_ MICRON) | Impedance Test Width | | .ind_orient_req | Boolean | Comp.; Pkg. | (Default=NO) Indicates that the component requires silkscreen orientation indication. (To be used in future actions.) | Orientation Indication Required | | .inp_file | Text | Layer | (0 to 500) Contains the name of the file (Gerber, Drill) from which the data was input into the layer. | Input File | | .ipc_class | Option | Product Model | (Class1; Class2; Class3; default=Class1) Defines the end-product class according to IPC-7351. | IPC Performance Class | | .ipc_via_type_botto m | Text | Feature | (0-100; default=0) Assigned to a via drill to indicate one of the IPC-4761 Via types for via tenting, covering, plugging and capping. Refers to the bottom side of the via drill. | IPC-4761 Bottom Via Type | | .ipc_via_type_top | Text | Feature | (0-100; default=0) Assigned to a via drill to indicate one of the IPC-4761 Via types for via tenting, covering, plugging and capping. Refers to the top side of the via drill. | IPC-4761 Top Via Type |
| Attribute | Type | Entity | Description | Display Name | |-------------------|---------|-------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------| | .is_buried | Boolean | Comp.; Pkg. | (Default=NO) Assigned to buried components. | Buried Component | | .is_capped | Boolean | Feature | (Obsolete) Used on via pads on top and bottom signal layers to indicate that the via is capped on this side. | Capped Via | | .is_shadowed | Boolean | Comp.; Pkg. | (Default=NO) Components with this attribute are considered vunerable to component shadowing. | Check for Shadowing | | .is_shield | Boolean | Comp.; Pkg. | (Default=NO) Components with this attribute assigned are designated as a shield. | Shield | | .is_wirebonded | Boolean | Comp.; Pkg. | (Default=NO) Defines a component to be wire-bonded. | Wirebonded Component | | .label_clearance | Boolean | Comp.; Pkg. | (Default=NO) Assigned to components that are not allowed to be too close to a glued label (e.g. fine pitch SOIC components). | Label Clearance | | .layer_class | Text | Layer | (0 to 1000 characters) Used to differentiate between layers. | Layer Class | | .layer_dielectric | Float | Layer | (0.0) Applies to layers of type DIELECTRIC or SOLDERMASK in the layer matrix that contains the thickness of material according to its specified Units of Measurement. (UNITS=INCH_MM) | Thickness of Material |
| Attribute | Type | Entity | Description | Display Name | |----------------------|--------|-------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------| | .layer_hdi_type | Option | Layer | (Buildup; Core) An attribute added to a copper layer-not a dielectric layer-to distinguish buildup layers from core layers in HDI product models. | HDI Layer Type | | .layer_side | Option | Layer | (Top, Bottom, Inner, None) Used to identify the location of a layer in the board stackup. For layers not in the board (such as documentation layers), 'None' is used. | Layer Side | | .lead_form | Text | Comp. | Used to classify components by lead type. Options: gw-small; gw; j-bend; l-bend; c-bend-wrap; side-concave; corner-concave; end-cap; other; flat-insulated; qfn; lcc; capae; m-column; lga; ball; axial; radial; inline; wire; pin; pressfit; mixed | Lead Form | | .local_fiducial_dist | Float | Comp.; Pkg. | (0.0 to 100.0) Defines the allowed distance of fiducials from the outline of the components that require local fiducials (See the attribute .num_local_fiducial.) If set to 0, the fiducials must be included INSIDE the outline. (UNITS=INCH_MM) | Search Distance for Local Fiducial | | .loss_tangent | Float | Layer | (0-100; Default=0) The parameter of a dielectric material that quantifies its inherent dissipation of electromagnetic energy. | Loss Tangent |
| Attribute | Type | Entity | Description | Display Name | |------------------|---------|-------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------| | .lpol_done | Boolean | Layer | (Default=NO) Reflects the state of the product model in whether or not the polarity sort according to a format has already been performed. | Polarity Order was Done | | .lpol_surf | Boolean | Feature | (Default=NO) Indicates surface modified by layer polarity reduction algorithm. | Polarity Optimization | | .lyr_prf_ref | Integer | Feature | (0-100000; Default=0) | Layer Profile Reference Number | | .machine_pkg | Text | Comp.; Pkg. | (0-100) Assigned to a component to indicate the name of a corresponding package in the assembly machine libraries. | Package Name for ALE | | .mechanical | Boolean | Comp | (YES, NO) Components with this attribute are considered part of the MECHNICAL section of a GenCAD file. | GENCAD Mechanical | | .merge_processes | Text | Step | (0-64) A list of the last three merge actions in the order in which they were run. The list is updated each time a merge (bom_merge, library_merge, board_merge) is run. It is for informational purposes and does not have to be changed by the user. | Assembly Merge Processes |
| Attribute | Type | Entity | Description | Display Name | |-----------------|---------|-------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------| | .min_line_width | Float | Net. | (0.0-100.0) Assigned to nets that should have a minimum trace width, i.e. each line of the net should have a width of at least this value. If such nets have a split (the net traces split and then meet again) the sum of the split traces should be at least this value. (UNITS=MIL_MICRON) | Min. Line Width | | .moat | Boolean | Feature | (YES, NO) Assigned to a moat feature added to a line or arc of the rout path. | Moat Feature | | .mount_hole | Boolean | Feature | (YES, NO) Used on drill features to indicate that they are mounting holes. | Mounting Hole | | .mount_stage | Integer | Comp.; Pkg. | (0-255; default=0) User-defined integer used to assign machine number in the assembly line where component is to be placed. | Placement Machine Number | | .n_electric | Boolean | Feature | (YES, NO) Assigned to a feature, defines it as non-electric (it is not considered for the current netlist for the step). | Non Electrical Feature | | .needs_guarding | Boolean | Comp.; Pkg. | (YES, NO) (Default=NO) YES-this component needs to be protected by guard components (see the attribute .guard_comp) else it is likely to be knocked off the board accidentally. | Require Guards | | .net_length_max | Float | Net | (0.0 to 100.0) High limit of net length. (UNITS=INCH_MM) | Net Max. Length |
| Attribute | Type | Entity | Description | Display Name | |--------------------|---------|----------------|-----------------------------------------------------------------------------------------------------------------|--------------------| | .net_length_min | Float | Net | (0.0 to 100.0) Lower limit of net length. (UNITS=INCH_MM) | Net Min. Length | | .net_name | Text | Feature; Layer | (0 to 10000) Set by the netlist layer. Contains the net name. | Net Name | | .net_physical_type | Text | Feature | (0 to 64) Physical type of constraint area used for search in table that contains physical parameters of nets. | Net Physical Type | | .net_point | Boolean | Feature | (YES, NO) When assigned to a pad in an inner layer, defines the pad as an internal test point. | Internal Net Point | | .net_spacing_type | Text | Feature | (0 to 64) SQA area name of an SQA area map. | Net Spacing Type | | .net_test_current | Float | Net | (0 to 100000) Nominal current associated with the corresponding net. | | | .net_test_type | Option | Net | (signal; power; ground) Classification type of an electrical net: Signal, Power, or Ground. | | | .net_test_voltage | Float | Net | (-100000 to 100000) Nominal voltage associated with the corresponding net. | | | .net_type | Text | Net | (0 to 64) A name for the type of net. The .net_type attribute can reference the set of routing rules for a net. | Net Type |
| Attribute | Type | Entity | Description | Display Name | |----------------------------|---------|-------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------| | .neutralization_angle | Float | Comp.; Pkg. | (0.0 to 360.0) An attribute attached to each component stating the angle of rotation counter- clockwise from ODB++ standard orientation. Consideration of this value provides a rotation neutralized component. | Rotation Neutralization | | .neutralization_info | Text | Step | (0 to 200) An attribute attached to a step indicating component rotation neutralization has occurred. This attribute contains the information <CPL|CAD>;<DataCenter>; Site. where Site is a name representing the location at which the correction was performed. | Neutralization Information | | .neutralization_ reviewed | Boolean | Comp.; Pkg. | (YES, NO) Attached to each component in a package reviewed for confirming component orientation correction conforms to ODB++ standard orientation. | Rotation Reviewed | | .neutralization_ss_ layers | Text | Step | (0 to 200) Attached to the step where component orientations have been validated to ODB++ standard rotations through the use of the .neutralization_angle attribute. This attribute designates which layers are to be considered the silkscreen layers. | Neutralization Silkscreen |
| Attribute | Type | Entity | Description | Display Name | |-------------------------|---------|-------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------| | .no_copper_shape_ under | Boolean | Comp.; Pkg. | (Default=NO) This attribute indicates that the component should not have copper pads or surfaces underneath it. See also the attribute .no_trace_under. | No Shape Under | | .no_fiducial_check | Boolean | Comp.; Pkg. | (Default=NO) Components with this attribute do not require fiducials. | No Fiducial Check | | .no_hole_under | Boolean | Comp.; Pkg. | (Default=NO) Indicates that no drill holes are allowed under the component. | No Hole Under | | .no_pop | Boolean | Comp.; Pkg. | (YES, NO) Designates a component as being not populated for the current version of the BOM. | Not Populated per BOM | | .no_protrude_board | Boolean | Comp | (YES, NO) Indicates that toeprint length (as defined by attribute .pin_length) should be less than the board thickness so that the pins do not protrude from the other side of the board. | Pins Cannot Protrude | | .no_text_under | Boolean | Comp.; Pkg. | (Default=NO) Assigned to a component, does not allow silk screen text to be placed under the component outline. Printed components (e.g. edge connectors) may not have this attribute. | No Silkscreen Under |
| Attribute | Type | Entity | Description | Display Name | |-----------------------|---------|-------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------| | .no_tp_under | Boolean | Comp.; Pkg. | (Default=NO) Assigned to a component, does not allow testpoints to be placed under the component outline. Printed components (e.g. edge connectors) may not have this attribute. | No Test Point Under | | .no_trace_under | Boolean | Comp.; Pkg. | (YES, NO) (Default=NO) YES-traces are NOT allowed under the component except for those that touch the component's toeprint pads and exit the component on that toeprint's side. | No Trace Under | | .no_uncap_via_unde r | Boolean | Comp.; Pkg. | (YES, NO) (Default=NO) YES-uncapped vias are NOT allowed under this component. | No Uncapped Vias Under | | .nomenclature | Boolean | Feature | (YES, NO) Defines a feature as a nomenclature (legend) feature. | Copper Text | | .non_tp | Boolean | Feature | (YES, NO) Assigned to a feature causes it NOT to be considered as a net testpoint. It is used for connectivity calculation but is not used as a test point (bare board testing). | Non Test Point | | .num_local_fiducials | Integer | Comp.; Pkg. | (0 to 20; default=0) Defines how many local fiducials are expected to be inside or near a component. | Number Local Fiducials Required | | .orbotech_plot_stam p | Boolean | Feature | NOT USED | Orbotech Plot Stamp | | .orig_surf | Integer | Feature | (0-2147483647; default=0) Identifies original surface that will be rebuilt. | Original Contour Index |
| Attribute | Type | Entity | Description | Display Name | |--------------------|---------|-----------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------| | .otherside_keepout | Option | Comp.; Pkg. | (full_area; pins_only; pads_only) Defines for components whether the other side of the board may also contain components in the same area. | NoComponents on Other Side | | .out_angle | Option | Layer | (0.0; 90.0; 180.0; 270.0; default=0.0) Contains the output angle to be used when generating manufacturing data. | Output Angle | | .out_break | Boolean | Feature; Symbol | (Default=NO) Indicates that upon output generation standard symbols and user-defined symbols should be replaced with basic primitive round and square symbols representing the intended shapes. | Output Break | | .out_comp | Float | Layer | (-100.0 to 100.0; default=0.0) Layer entity attributes with default values that are used by the output translator. | Output Compensation | | .out_drill_full | Boolean | Step | (Default=NO) This attribute can be used for a drill coupon that needs to be fully drilled before continuing to the next step and repeat entity. | Output Drill Full |
| Attribute | Type | Entity | Description | Display Name | |---------------------|---------|---------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------| | .out_drill_optional | Boolean | Feature; Step | (Default=NO) If a drill feature is set with this attribute it will have the ' / ' command prefix in the final output file, indicating that the drill is optional. If a step entity attribute is set, then all the commands that are part of that step will have the ' / ' command prefixed. Thus, the whole step is optional. | Output Drill Optional | | .out_drill_order | Integer | Step | (-10000 to 10000; default=0) The attribute controls the order in which the steps are drilled. That is, who is first, second, etc. The attribute has the following valid values: 0-no special order for that step 1-first 2-second 3-and above, order from the beginning -1-last -2-one before last -3-and on (drill order from the end) | Output Drill Order | | .out_flag | Integer | Feature | (-1 to 1000000; default=-1) (Obsolete) Used for Excellon translation. | Excellon Unknown | | .out_mirror | Boolean | Layer | (Default=NO) Indicates the output could be mirrored along the X- axis when generating manufacturing data. | Output Mirror | | .out_name | Text | Step | (Obsolete) | Output Name |
| Attribute | Type | Entity | Description | Display Name | |--------------------|---------|---------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------| | .out_orig | Boolean | Feature | (Obsolete) | Rout Output Origin | | .out_polarity | Option | Layer | (Positive; Negative) Contains the output polarity to be used when generating manufacturing data. | Output Polarity | | .out_rout_optional | Boolean | Feature; Step | (Default=NO) If drill feature is set with this attribute it will have the '/' command in front of it in the final output file. This means that the drill is optional. If a step entity attribute is set then all the commands that are part of that step will have the '/' command at the beginning. Thus, the whole step is optional. | Output Rout Optional | | .out_rout_order | Integer | Step | (-10000 to 10000; default=0) The attribute controls the order in which the steps will be drilled. Thus, who is first, second, etc. The attribute has the following valid values: 0 -no special order for that step 1-first 2-second 3 and above-order from the beginning -1-last -3 and on-drill order from the end | Output Rout Order |
| Attribute | Type | Entity | Description | Display Name | |---------------|---------|-----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------| | .out_scale | Boolean | Feature; Symbol | (Default=NO) During the generation of manufacturing data, it may be required to specify whether certain features can be scaled or not. This is important in cases where special registration targets would not be scaled together with all the other features. This special output option applies only to features that have this attribute set. In the case of a user-defined symbol, setting the attribute enables you to control the scaling of all features using the symbol. | Output Scale | | .out_x_scale | Float | Layer | (0.000001 to 5.0; default=1.0) Contains the output scale along the X-axis to be used when generating manufacturing data. | Output X Scale | | .out_y_scale | Float | Layer | (0.000001 to 5.0; default=1.0) Contains the output scale along the Y-axis to be used when generating manufacturing data. | Output Y Scale | | .output_dcode | Integer | Feature | (0 -1000000) Assigned to features to provide action codes for an assembly machine, such as the GSI Lumonics laser cutter. | GSI Lumonics Output Dcode |
| Attribute | Type | Entity | Description | Display Name | |------------------|---------|-------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------| | .package_type | Text | Comp. | (1 to 64 characters) Used to classify components by package type. Options: melf; axial; radial; cyl-tall; cc; chip; connector; fp; ga; sip-dip; smt-misc; so; thru- misc | Package Type | | .package_version | Text | Comp.; Pkg. | (0 to 50) Used for Zuken Board Designer translation. | Zuken Package Info | | .pad_usage | Option | Feature | (toeprint; via; g_fiducial; l_fiducial; tooling_hole) This attribute defines the specific usage of a pad. | Pad Usage | | .padstack_id | Integer | Feature | (0 to 2 32 ) Defines an ID for all pads attached to the same drill. The value should be unique in the context of the board. | Padstack ID | | .part_desc1...10 | Text | Comp.; Pkg. | (0 to 1000) Ten BOMdescription fields. | Part Description 1 ... Part Description 10 | | .patch | Boolean | Feature | (YES, NO) Assigned to features added to eliminate pin holes. | Copper Patch | | .pattern_fill | Boolean | Feature | (YES, NO) Assigned to features that represent a pattern fill, typically used for copper balancing. Best practice in copper balancing is to use zero length lines where X/Y start is the same as X/Y end (rather than pads) to support manufacturing that requires data preparation. | Copper Balancing |
| Attribute | Type | Entity | Description | Display Name | |------------------|---------|-------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------| | .pf_optimized | Boolean | Feature | (YES, NO) This attribute describes the state of the product model. It is attached to a padstack that has had non-functional pads removed. | Optimized Pad Stack | | .physical_type | Text | Net | (0 to 64) Physical type of net. | Physical Type | | .pilot_hole | Integer | Feature | (0 to 100000; default=0) Attribute assigned to pads that are pilot holes in a chain (holes that are drilled in each tool down in the chain rout path before routing the chain). The value of the attribute is the serial chain number to which the pilot hole belongs. When merging or inserting chains, the pilot holes are updated automatically. (UNITS=MIL_MICRON) | Rout Pilot Hole | | .pin_length | Float | Comp. | (0.0-10.0) The length of THcomponent pins. (UNITS=INCH_MM) | Pin Length | | .pin_name | Text | Comp. | Name of the die bump. | Name of Die Bump | | .pitch | Float | Feature | NOT USED | | | .placement_layer | Text | Comp.; Pkg. | (0 - 64) Receives the value of the EMBEDDED_LAYER parameter from the Cadence Allegro file pins_<product model>.out . | Placement Layer | | .plated_type | Option | Feature | (Standard, Press_fit) Defines plated hole type for drill tools. | Through Hole Type | | .plug_vias | Boolean | Step | (Obsolete) Indicates whether vias should be plugged. | Plug Vias |
| Attribute | Type | Entity | Description | Display Name | |----------------------|---------|---------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| | .polarity_marker | Integer | Comp.; Pkg. | (1-10000; default=1) Anattribute indicating which pin of the component is Pin 1. | Polarity Indicator Pin | | .primary_side | Option | Product Model | (Top; Bottom) Indicates the primary side for this product model. | Primary Side | | .producibility_level | Option | Product Model | (levela; levelb; levelc; default=levelb) Defines the design density level according to IPC-7351: • levela -Maximum (most) land protrusion • levelb -Medium (nominal) land protrusion • levelc -Minimum (least) land protrusion | IPC-7531 Density Level | | .rf | Option | Feature | (original; fixed) Defines the status of a radio frequency surface-whether or not they it has been enlarged by 10 pixels. original - indicates it has not been enlarged. fixed - indicates that it has been enlarged. | Radio Frequency Surface | | .rot_correction | Integer | Comp.; Pkg. | (0-359) Componentmachine rotation correction to apply. | Rotation Correction | | .rout_chain | Integer | Feature | (0 to 100000; default=0) Contains the serial number of the chain to which the feature belongs. Features belonging to that chain are rearranged in the features file according to their order inside the chain. Additional attributes that are added to a chained feature: .feed, .speed, .rout_flag, .comp. | Rout Chain |
| Attribute | Type | Entity | Description | Display Name | |------------------------|---------|----------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------| | .rout_flag | Integer | Feature | (0 to 100000; default=0). For each chained feature this attribute represents a numeric value supplied to a chain. | Rout Flag | | .rout_plated | Boolean | Feature | Indicates that a feature on a rout layer is plated. The .drill attribute is still used in rout layers, but the .rout_plated attribute takes precedence on rout layers, if both exist. | Plated Rout | | .shave | Boolean | Feature | (Default=NO) Assigned to negative features used to optimize layer content for manufacturing purposes. | Silkscreen Shaved | | .sip | Option | Feature | (Detected / Repaired). Indicates the presence of a SIP (self-intersecting polygon). | Self Intersecting Polygon | | .sliver_fill | Boolean | Feature | (YES, NO) Assigned to all features added to eliminate slivers. | Sliver Fill Patch | | .smd | Boolean | Feature | (YES, NO) Assigned to outer layer pads designated as toeprints that are lands for SMD components. | SMD | | .smt_direction_botto m | Option | Step | (Left2Right; Top2Bottom; Right2Left; Bottom2Top) Defines the direction of the SMT process flow on the bottom side. | SMT Direction (Bottom) | | .smt_direction_top | Option | Step | (Left2Right; Top2Bottom; Right2Left; Bottom2Top) Defines the direction of the SMTprocess flow on the top side. | SMT Direction (Top) |
| Attribute | Type | Entity | Description | Display Name | |------------------------------|---------|----------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------| | .soldermask_define_ no_edits | Boolean | Feature | Defines the exposed copper region. Outer layer features and soldermask features assigned this attribute define the region. | Soldermask Defined Pad-No Edits | | .source_llayer | Text | Feature | (0-64) This attribute identifies the Source Logical Layer of features (traces) appearing on signal or mixed layers. | Source Layer | | .spacing_req | Float | Feature | (0.0 to 100.0) (UNITS=MILS_ MICRONS) | Spacing Required | | .speed | Integer | Feature | (0 to 100000; default=0) For a chained feature this attribute sets the spindle speed (in revolutions per minute) when routing. | Rout Spindle Speed | | .spo_h_fact | Float | Feature; Comp. | (0.3 <-> 2.0; default=0.8) When .spo_h_mode = Factor, .spo_h_fact specifies the factor by which paste pad heights are sized relative to their SMD pads. For example, 0.9 means height is 90% of SMD pad. | Solderpaste Height Factor Value | | .spo_h_mode | Option | Feature; Comp. | (Distance, Factor, Value) Defines how heights of paste pads are sized: by distance, factor or value. | Create Solderpaste Height Mode |
| Attribute | Type | Entity | Description | Display Name | |------------------|--------|----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------| | .spo_h_val | Float | Feature; Comp. | (-500 to +500; default=5) When .spo_h_mode=Distance, .spo_h_val is the reduction/ expansion in mils or microns of the paste pad width relative to the SMD pad width. For example, .sp_h_val=5.0 mils shrinks paste pad by 5.0 mils (2.5 mils on each side) relative to SMD pad width. Positive number results in smaller paste pad, negative number in larger paste pad. When .spo_h_mode=Value, .spo_h_val becomes the absolute width of the paste pad (for example, 5.0 mils becomes the actual width of the paste pad). (UNITS=MIL_ MICRON) | Solderpaste Height Relative Value | | .spo_move_center | Float | Feature; Comp. | (range: -500 to 500, default=0) To move the paste pad from the SMD pad center. A positive value will move the paste from the component center out. A negative value will move the paste towards the component center. (UNITS=MIL_MICRON) | Shift Solderpaste Symbol | | .spo_p_fact | Float | Feature; Comp. | (0.3 <-> 2.0; default=0.8) When .spo_p_mode=Factor, .spo_p_fact specifies the factor by which paste pad heights are sized relative to their SMD pads. For example, 0.9 means area is 90% of SMD pad. | Solderpaste Nonstandard Factor Value |
| Attribute | Type | Entity | Description | Display Name | |-------------|--------|----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------| | .spo_p_mode | Option | Feature; Comp. | (Distance, Area) Defines how paste pads for non-standard symbol SMD pads are sized: by distance, or area. | Create Solderpaste Nonstandard Mode | | .spo_p_val | Float | Feature; Comp. | (-500 to 500; default=5) When .spo_p_mode=Distance, .spo_p_val is the reduction/ expansion of the paste pad width relative to the SMD pad width expressed in mils or microns. For example, .sp_p_val=5.0 mils shrinks paste pad by 5.0 mils (2.5 mils on each side) relative to SMD pad width. Positive number results in smaller paste pad, negative number in larger paste pad. (UNITS=MIL_MICRON) | Create Solderpaste Nonstandard Mode | | .spo_s_fact | Float | Feature; Comp. | (0.3 <-> 2.0; default=0.8) When .spo_s_mode=Factor, .spo_s_fact specifies the factor by which paste pad heights are sized relative to their non-standard SMD pads. For example, 0.9 means height is 90% of SMD pad. | Solderpaste Symmetric Factor Value | | .spo_s_mode | Option | Feature; Comp. | (Distance, Factor, Value, Area) Defines how heights of paste pads for symmetric SMD pads are sized: by distance, factor, value, area. | Create Solderpaste Symmetric Mode |
| Attribute | Type | Entity | Description | Display Name | |-------------------|--------|----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------| | .spo_s_val | Float | Feature; Comp. | (-500 to 500; default=5) When .spo_s_mode=Distance, .spo_s_val is the reduction/ expansion expressed in mils or microns of the paste pad width relative to their non- standard SMD pad width. When .spo_h_mode=Value, .spo_h_val becomes the absolute size of the paste pad. (UNITS=MIL_MICRON) | Solderpaste Symmetric Relative Value | | .spo_shape | Text | Feature; Comp. | Specifies the symbol to be used as the solder paste pad applied to a feature (smd pad) or to the toeprints of a component. The initial orientation of the symbol is also affected by the .spo_shape_rotate attribute when defined. | Apply Solderpaste Symbol | | .spo_shape_rotate | Float | Feature; Comp. | (0 to 360; default=0) Specifies the initial rotation of the symbol defined in the .spo_shape attribute. Both .spo_shape_rotate and .spo_shape should appear as a pair at the level at which they are activated (component or feature). This means, for example, that an .spo_shape_rotate defined without a corresponding .spo_shape in the feature level is ignored. | Apply Solderpaste Rotation |
| Attribute | Type | Entity | Description | Display Name | |--------------------|---------|----------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------| | .spo_shape_stretch | Boolean | Feature; Comp. | (Default=NO) Specifies that the symbol defined in .spo_shape is to be stretched to fit the copper pad dimensions. The stretch limits are determined by applying the SPO width and height parameters (pp_w_, pp_h_) or attributes (.spo_w_, .spo_h_) on the copper pad bounding box. Both .spo_shape_stretch and .spo_shape should appear as a pair at the level at which they are activated (component or feature). This means, for example, that an .spo_shape_stretch defined without a corresponding .spo_shape in the feature level is ignored. | Extend Solderpaste Symbol | | .spo_w_fact | Float | Feature, Comp. | (0.3 <-> 2.0; default=0.8) When.spo_w_mode=Factor, .spo_w_fact specifies the factor by which paste pad widths are sized relative to their SMD pads. For example, .spo_w_fact=0.9 width of paste pad is 90% of width of SMD pad. | Solderpaste Width Factor Value | | .spo_w_mode | Option | Feature, Comp. | (Distance; Factor; Value; Area) Defines how widths of paste pads are sized: by distance, factor or value. | Create Solderpaste Wide Mode |
| Attribute | Type | Entity | Description | Display Name | |------------------|---------|----------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------| | .spo_w_val | Float | Feature, Comp. | (-500 to 500; default=5) When .spo_w_mode=Distance, .spo_w_val is the reduction/ expansion expressed in mils or microns of the paste pad width relative to the SMD pad width. For example, .sp_w_val=5.0 mils shrinks paste pad by 5.0 mils (2.5 mils on each side) relative to SMD pad width. Positive number results in smaller paste pad, negative number in larger paste pad. When .spo_w_mode=Value, .spo_w_val becomes the absolute width of the paste pad (for example, 5.0 mils becomes the actual width of the paste pad). (UNITS=MIL_MICRON) | Solderpaste Width Relative Value | | .src_orientation | Integer | Comp. | (-1 to 3; default=-1) Defines the zero orientation of this component relative to its orientation in the packages database. That is, the orientation of the component on the automated assembly tape, or (for manually inserted components) the orientation in which pin #1 is 'in the same position' for all similar components. | Source Orientation | | .station | Text | Comp.; Pkg. | NOT USED (Min_len= 0, Max_len=255) | ALE Station |
| Attribute | Type | Entity | Description | Display Name | |--------------------------------------|---------|----------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------| | .string | Text | Feature | (0 to 1000) For nomenclature features, the value of this attribute is the original text string of which the feature is a part. See 'TEXT Attribute Definition' on page 88. | Copper Text String | | .string_angle | Float | Feature | (0 to 360) For nomenclature features, the value of this attribute is the original (in the input file) text rotation angle of which the feature is a part. | String Angle | | .string_font | Text | Feature | (1 to 100 characters) For nomenclature features, the value of this attribute is the font of the original text string of which this feature is a part. | String Font | | .string_justification | Option | Feature | String justification: tl, tc, tr, cl, cc, cr, bl, bc, br tl, tc, tr -top-left, top- center, top-right cl, cc, cr -center-left, center-center, center-right bl, bc, br -bottom-left, bottom-center, bottom-right (Default= bl ) | String Justification | | .string_mirrored | Boolean | Feature | (YES, NO) Assigned to mirrored strings. | String Mirror | | .tear_drop | Boolean | Feature | (YES, NO) Assigned to features representing a tear drop. | Tear Drop Feature | | .teardrop_additio n_allowed_on_inner | Boolean | Step | Indicates whether it is allowed to add teardrops on inner copper layers. | Teardrop Addition Allowed on Inner | | .teardrop_additio n_allowed_on_outer | Boolean | Step | Indicates whether it is allowed to add teardrops on outer copper layers. | Teardrop Addition Allowed on Outer |
| Attribute | Type | Entity | Description | Display Name | |------------------|---------|---------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------| | .technology | Text | Product Model | (0-100) Defines the technology used in creating the product model. | Technology | | .test_point | Boolean | Feature | (YES, NO) Assigned to features that are used for In-Circuit Testing operations. | ICT Test Point | | .test_potential | Option | Feature | An attribute attached to features being considered as testpoints (potential testpoints) for In-Circuit Testing operations. potential_tp_by_analysis-a feature meeting all criteria of the Testpoint Allocation Action. potential_tp_manually-a feature to be used as a testpoint though it does not meet all criteria. not_potential_tp_manually -a feature not to be used as a testpoint even though it meets all criteria. | Test Point Potential | | .testpoint_count | Integer | Net | (-1 to 10000) Specifies the number of testpoints expected on this net. If this variable is not defined, or its value is -1 , the number of expected testpoints in unlimited. A value of -1 is given to a net that does not require a specific number of test points. | Expected Test Point Count | | .testpoint_name | Text | Feature | (0 to 64) Name of the testpoint. | Testpoint Name |
| Attribute | Type | Entity | Description | Display Name | |---------------------|---------|---------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------| | .testprobe_diameter | Float | Feature | (10 to 10000; default=30) Used to provide information on the size of test probes. (UNITS=MIL_MICRON) | Test Probe Diameter | | .thickness_over_cu | Float | Step | (1.0 to 1000.0; default=1.0) (UNITS=MIL_MICRON) | Total Thickness over Copper | | .thickness_over_sm | Float | Step | (1.0 to 1000.0; default=1.0) (UNITS=MIL_MICRON) | Total Thickness over Soldermask | | .thvpad_required | Boolean | Comp.; Pkg. | (Default=NO) Assigned to components that require thieving pads (such as fine pitch SOIC). | Thieving Pad Required | | .toep_nochk_o_side | Boolean | Comp.; Pkg. | (Default=NO) Assigned to components so that their toeprints on the opposite side will not be taken into account. | Toeprint Spacing on Placement Side | | .toep_spacing_req | Float | Comp.; Pkg. | (1 to 500; default=5) Defines for components the maximum pad to pad spacing measurements. (UNITS=MIL_MICRON) | Required Toeprint Spacing | | .tooling_hole | Boolean | Feature | (YES, NO) Used on drill features to indicate that they are tooling holes. | Tooling Hole | | .user_bom_rev | Text | Comp.; Pkg. | (0-1000) Used to describe user modified component extensions. | User Define Extension | | .variant_list | Text | Product Model | (0-1000) Consists of a list of all possible variants of a product model. The list contains variant names separated by a colon (:). See 'Component Variants' on page 41. | Product Model Variant List |
| Attribute | Type | Entity | Description | Display Name | |----------------|---------|----------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------| | .vcut | Boolean | Feature | (YES, NO) Assigned to rout features that are cut in a V-shape. | V-Score Edge | | .via_in_pad | Boolean | Feature | (YES, NO) Assigned to via drills located in copper surfaces or pads. To define a via drill as filled and plated over (VIPPO), set this attribute in combination with .ipc_via_type_top=7 and .ipc_via_type_bottom=7. | Via in Pad | | .via_tenting | bool | Step | (Obsolete) Indicates whether there are tented vias. | Via Tenting | | .via_type | Option | Feature | (Drilled; Laser; Photo) Assigned to via drills for further classification. | Via Type | | .viacap_layer | Option | Step | (Obsolete) (Top; Bottom; Both; None; default=None) Defines on which layer via capping can occur, if any. | Via Capping on Layer | | .vpl1_pkg_name | Text | Comp. | (0 to 100 characters) The old name of the package of this component, in VPL1. | VPL Package Name (BVPL1) | | .wheel_type | Option | Wheel | (Gerber; Tools) Specifies for a wheel whether it is used for Gerber files translation or for drill file translation. | Wheel Type | | .z0impedance | Float | Layer | (0.0 to 10000.0; default=0.0) The typical characteristic impedance (in ohms) required for a layer. | Z0/Impedance |
ODB++ System Attributes by Class
ODB++ system attributes are listed here by class. For each class, the name of the sysattr file is indicated, in which attribute definitions are stored for the class.
For a description of attributes, see 'ODB++ System Attributes - Alphabetical List' on page 215.
See 'Attribute Classes' on page 27.
Attributes are listed for these classes:
| Product (sysattr) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 271 | |---------------------------------------------------------------------------------------------------------------------------------------|-------| | DFM(sysattr.dfm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 276 | | Fabrication (sysattr.fab) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 279 | | Assembly (sysattr.assy) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 281 | | Test (sysattr.test) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 283 | | Generic (sysattr.gen) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 284 |
Product (sysattr)
These attributes support the product.
Table B-1. ODB++ Product Attributes
| ODB++ Product Attributes | |----------------------------------------| | .all_eda_layers | | .allowed_to_remove_non_functional_pads | | .artwork | | .board_thickness | | .break_away | | .brk_point | | .bulk_resistivity | | .cad_local_footprint_change | | .cad_package_name | | .cad_part_override | | .centroid_correction_x | | .centroid_correction_y | | .comment |
Table B-1. ODB++ Product Attributes (cont.)
| ODB++ Product Attributes | |----------------------------| | .comp_height | | .comp_height_area | | .comp_height_max | | .comp_htol_minus | | .comp_htol_plus | | .comp_polarity | | .comp_variant_list | | .comp_weight | | .copper_weight | | .critical_net | | .critical_tp | | .cu_base | | .current_variant | | .customer | | .data_source | | .desc1....10 | | .design_center | | .design_origin_x | | .design_origin_y | | .dielectric_constant | | .diff_pair | | .drill | | .drill_layer_direction | | .ecmp_layer_tech | | .ecmp_max_value | | .ecmp_min_value | | .ecmp_name | | .ecmp_value | | .eco | | .eda_define_imp_line |
Table B-1. ODB++ Product Attributes (cont.)
| ODB++ Product Attributes | |----------------------------| | .eda_dimension_id | | .eda_layers | | .fiducial_rdlist | | .geometry | | .gold_plating | | .gold_plating_defined_by | | .hatch | | .hatch_border | | .hatch_serrated_border | | .ignore_net | | .imp_constraint_id | | .imp_line | | .imp_polyline_id | | .impedance_test_width | | .inp_file | | .ipc_class | | .ipc_via_type_bottom | | .ipc_via_type_top | | .is_buried | | .is_capped | | .is_shield | | .is_wirebonded | | .layer_dielectric | | .layer_hdi_type | | .loss_tangent | | .lyr_prf_ref | | .mechanical | | .merge_processes | | .moat | | .mount_hole |
Table B-1. ODB++ Product Attributes (cont.)
| ODB++ Product Attributes | |----------------------------| | .n_electric | | .net_name | | .net_physical_type | | .net_point | | .net_spacing_type | | .net_type | | .neutralization_angle | | .neutralization_info | | .neutralization_reviewed | | .neutralization_ss_layers | | .no_pop | | .nomenclature | | .non_tp | | .package_version | | .pad_usage | | .padstack_id | | .part_desc1...10 | | .patch | | .pattern_fill | | .pf_optimized | | .pitch | | .plated_type | | .plug_vias | | .polarity_marker | | .primary_side | | .producibility_level | | .rout_plated | | .shave | | .sip | | .sliver_fill |
Table B-1. ODB++ Product Attributes (cont.)
| ODB++ Product Attributes | |-------------------------------------| | .smd | | .soldermask_define_no_edits | | .source_llayer | | .string | | .string_angle | | .string_justification | | .string_mirrored | | .tear_drop | | .teardrop_addition_allowed_on_inner | | .teardrop_addition_allowed_on_outer | | .technology | | .test_point | | .test_potential | | .testpoint_name | | .testprobe_diameter | | .thickness_over_cu | | .thickness_over_sm | | .tooling_hole | | .user_bom_rev | | .variant_list | | .vcut | | .via_in_pad | | .via_tenting | | .via_type | | .viacap_layer | | .wheel_type | | .z0impedance |
DFM (sysattr.dfm)
These attributes support Design For Manufacture (DFM).
Table B-2. ODB++ DFM Attributes
| ODB++ DFMAttributes | |--------------------------| | .ar_pad_drill_bottom_max | | .ar_pad_drill_bottom_min | | .ar_pad_drill_inner_max | | .ar_pad_drill_inner_min | | .ar_pad_drill_top_max | | .ar_pad_drill_top_min | | .ar_sm_drill_bottom_max | | .ar_sm_drill_bottom_min | | .ar_sm_drill_top_max | | .ar_sm_drill_top_min | | .ar_sm_pad_bottom_max | | .ar_sm_pad_bottom_min | | .ar_sm_pad_top_max | | .ar_sm_pad_top_min | | .area_name | | .center_fiducial | | .comp_ign_spacing | | .comp_ignore | | .comp_mount_type | | .comp_type | | .comp_type2 | | .dpair_gap | | .drc_assembly_lyrs | | .drc_bend_keepout | | .drc_board | | .drc_comp_height | | .drc_comp_height_lyr |
Table B-2. ODB++ DFM Attributes (cont.)
| ODB++ DFMAttributes | |-----------------------------------------------| | .drc_comp_keepin | | .drc_comp_keepin_lyr | | .drc_comp_keepout | | .drc_comp_keepout_lyr | | .drc_etch_lyrs | | .drc_etch_lyrs_all | | .drc_etch_lyrs_bit | | .drc_max_height | | .drc_mech | | .drc_min_height | | .drc_pad_keepout | | .drc_pad_keepout_lyr | | .drc_plane_keepout | | .drc_plane_keepout_lyr | | .drc_ref_des | | .drc_route_keepin | | .drc_route_keepin_lyr | | .drc_route_keepout | | .drc_route_keepout_lyr | | .drc_tp_keepin | | .drc_tp_keepin_lyr | | .drc_tp_keepout | | .drc_tp_keepout_lyr | | .drc_trace_keepout | | .drc_trace_keepout_lyr | | .drc_via_keepout | | .drc_via_keepout_lyr | | .eclass_accumulative_parallel_dist_list | | .eclass_accumulative_parallel_max_length_list | | .eclass_impedance |
Table B-2. ODB++ DFM Attributes (cont.)
| ODB++ DFMAttributes | |---------------------------------------------| | .eclass_individual_parallel_dist_list | | .eclass_individual_parallel_max_length_list | | .eclass_individual_parallel_min_jog_list | | .eclass_max_stub_length | | .eclass_max_via_count | | .eclass_min_stub_length | | .eclass_rise_time | | .eclass_voltage_swing | | .electrical_class | | .fab_drc | | .feature_ignore | | .guard_comp | | .hdi_assembly_tech | | .hdi_drc | | .ind_orient_req | | .is_shadowed | | .label_clearance | | .layer_class | | .layer_side | | .lead_form | | .local_fiducial_dist | | .min_line_width | | .needs_guarding | | .net_length_max | | .net_length_min | | .no_copper_shape_under | | .no_fiducial_check | | .no_hole_under | | .no_protrude_board | | .no_text_under |
Table B-2. ODB++ DFM Attributes (cont.)
| ODB++ DFMAttributes | |-----------------------| | .no_tp_under | | .no_trace_under | | .no_uncap_via_under | | .num_local_fiducials | | .otherside_keepout | | .package_type | | .physical_type | | .pin_length | | .placement_layer | | .rf | | .spacing_req | | .src_orientation | | .string_font | | .testpoint_count | | .thvpad_required | | .toep_nochk_o_side | | .toep_spacing_req |
Fabrication (sysattr.fab)
These attributes support fabrication.
Table B-3. ODB++ Fabrication Attributes
| ODB++ Fabrication Attributes | |---------------------------------| | .aoi_cpbm | | .aoi_cpcu | | .aoi_drbm | | .aoi_drcu | | .aoi_value | | .array_with_rotation | | .backdrill_penetrate_stop_layer |
Table B-3. ODB++ Fabrication Attributes (cont.)
| ODB++ Fabrication Attributes | |--------------------------------| | .bit | | .comp | | .cut_line | | .drc_add_rad | | .drc_min_space | | .drc_min_width | | .drill_flag | | .drill_noopt | | .drill_sr_zero | | .drill_stage | | .et_adjacency | | .et_align | | .extended | | .feed | | .fiducial_name | | .fill_dx | | .fill_dy | | .foot_down | | .full_plane | | .global_camtek_aoiset | | .image_dx | | .image_dy | | .lpol_done | | .lpol_surf | | .orbotech_plot_stamp | | .out_angle | | .out_break | | .out_comp | | .out_drill_full | | .out_drill_optional |
Table B-3. ODB++ Fabrication Attributes (cont.)
| ODB++ Fabrication Attributes | |--------------------------------| | .out_drill_order | | .out_flag | | .out_mirror | | .out_name | | .out_orig | | .out_polarity | | .out_rout_optional | | .out_rout_order | | .out_scale | | .out_x_scale | | .out_y_scale | | .pilot_hole | | .rout_chain | | .rout_flag | | .speed |
Assembly (sysattr.assy)
These attributes support assembly.
Table B-4. ODB++ Assembly Attributes
| ODB++ Assembly Attributes | |-----------------------------| | .assembly_proc_bottom | | .assembly_proc_top | | .axi_direction | | .bond_name | | .bonding_profile | | .comp_name | | .device_style | | .device_type | | .device_value |
Table B-4. ODB++ Assembly Attributes (cont.)
| ODB++ Assembly Attributes | |-----------------------------| | .device_value_ntol | | .device_value_ptol | | .ecmp_type | | .fs_direction_bottom | | .fs_direction_top | | .gencad_device_ntol | | .gencad_device_ptol | | .gencad_device_style | | .gencad_device_type | | .gencad_device_value | | .machine_pkg | | .mount_stage | | .pin_name | | .rot_correction | | .smt_direction_bottom | | .smt_direction_top | | .spo_h_fact | | .spo_h_mode | | .spo_h_val | | .spo_move_center | | .spo_p_fact | | .spo_p_mode | | .spo_p_val | | .spo_s_fact | | .spo_s_mode | | .spo_s_val | | .spo_shape | | .spo_shape_rotate | | .spo_shape_stretch | | .spo_w_fact |
Table B-4. ODB++ Assembly Attributes (cont.)
| ODB++ Assembly Attributes | |-----------------------------| | .spo_w_mode | | .spo_w_val | | .station | | .vpl1_pkg_name |
Test (sysattr.test)
These attributes support testing.
Table B-5. ODB++ Test Attributes
| ODB++ Test Attributes | |-------------------------| | .board_mark | | .hp3070_comment | | .hp3070_common_pin | | .hp3070_contact_pin | | .hp3070_device | | .hp3070_fail_msg | | .hp3070_hi_value | | .hp3070_lo_value | | .hp3070_probe_access | | .hp3070_seriesr | | .hp3070_test | | .hp3070_tol_neg | | .hp3070_tol_pos | | .hp3070_type | | .hp3070_value | | .net_test_current | | .net_test_type | | .net_test_voltage |
Generic (sysattr.gen)
These are generic attributes.
Table B-6. ODB++ Generic Attributes
| ODB++ Generic Attributes | |----------------------------| | .color | | .dxf_dimension | | .orig_surf | | .output_dcode |
Appendix C Standard Font
This section contains the font definition for the font Standard used for ODB++ text. The file is not part of the ODB++ format, but the geometry of character and letter representations is part of the ODB++ format.
The format of a fonts file is described in 'fonts (Fonts Used in Product Model)' on page 48.
XSIZE 0.302000 YSIZE 0.302000 OFFSET 0.000000 CHAR ! LINE 0.000000 0.000000 0.000000 0.200000 P R 0.012000 LINE 0.000000 -0.100000 0.000000 -0.100000 P R 0.012000 ECHAR CHAR " LINE -0.050000 0.100000 -0.050000 0.200000 P R 0.012000 LINE 0.050000 0.100000 0.050000 0.200000 P R 0.012000 ECHAR CHAR # LINE -0.050000 -0.100000 -0.050000 0.200000 P R 0.012000 LINE 0.050000 -0.100000 0.050000 0.200000 P R 0.012000 LINE -0.100000 0.000000 0.100000 0.000000 P R 0.012000 LINE -0.100000 0.100000 0.100000 0.100000 P R 0.012000 ECHAR CHAR $ LINE 0.000000 -0.100000 0.000000 0.200000 P R 0.012000 LINE -0.100000 -0.050000 0.050000 -0.050000 P R 0.012000 LINE 0.050000 -0.050000 0.100000 0.000000 P R 0.012000 LINE 0.100000 0.000000 0.050000 0.050000 P R 0.012000 LINE 0.050000 0.050000 -0.050000 0.050000 P R 0.012000 LINE -0.050000 0.050000 -0.100000 0.100000 P R 0.012000 LINE -0.100000 0.100000 -0.050000 0.150000 P R 0.012000 LINE -0.050000 0.150000 0.100000 0.150000 P R 0.012000 ECHAR CHAR % LINE -0.100000 -0.100000 0.100000 0.200000 P R 0.012000 LINE -0.075000 0.175000 -0.075000 0.175000 P R 0.012000 LINE 0.075000 -0.075000 0.075000 -0.075000 P R 0.012000 ECHAR CHAR & LINE 0.100000 -0.100000 -0.100000 0.100000 P R 0.012000 LINE -0.100000 0.100000 -0.100000 0.150000 P R 0.012000 LINE -0.100000 0.150000 -0.050000 0.200000 P R 0.012000 LINE -0.050000 0.200000 0.000000 0.150000 P R 0.012000 LINE 0.000000 0.150000 0.000000 0.100000 P R 0.012000 LINE 0.000000 0.100000 -0.100000 0.000000 P R 0.012000 LINE -0.100000 0.000000 -0.100000 -0.050000 P R 0.012000 LINE -0.100000 -0.050000 -0.050000 -0.100000 P R 0.012000 LINE -0.050000 -0.100000 0.000000 -0.100000 P R 0.012000 LINE 0.000000 -0.100000 0.100000 0.000000 P R 0.012000 ECHAR CHAR ' LINE 0.000000 0.050000 0.050000 0.150000 P R 0.012000 LINE 0.025000 0.175000 0.025000 0.175000 P R 0.012000 ECHAR CHAR (
LINE 0.050000 -0.100000 -0.050000 0.000000 P R 0.012000 LINE -0.050000 0.000000 -0.050000 0.100000 P R 0.012000 LINE -0.050000 0.100000 0.050000 0.200000 P R 0.012000 ECHAR CHAR ) LINE -0.050000 -0.100000 0.050000 0.000000 P R 0.012000 LINE 0.050000 0.000000 0.050000 0.100000 P R 0.012000 LINE 0.050000 0.100000 -0.050000 0.200000 P R 0.012000 ECHAR CHAR * LINE -0.100000 -0.050000 0.100000 0.150000 P R 0.012000 LINE -0.100000 0.150000 0.100000 -0.050000 P R 0.012000 LINE 0.000000 -0.100000 0.000000 0.200000 P R 0.012000 ECHAR CHAR + LINE -0.100000 0.050000 0.100000 0.050000 P R 0.012000 LINE 0.000000 -0.050000 0.000000 0.150000 P R 0.012000 ECHAR CHAR , LINE 0.000000 -0.100000 0.050000 0.000000 P R 0.012000 LINE 0.025000 0.025000 0.025000 0.025000 P R 0.012000 ECHAR CHAR LINE -0.100000 0.050000 0.100000 0.050000 P R 0.012000 ECHAR CHAR . LINE 0.025000 -0.075000 0.025000 -0.075000 P R 0.012000 ECHAR CHAR / LINE -0.100000 -0.050000 0.100000 0.150000 P R 0.012000 ECHAR CHAR 0 LINE -0.100000 -0.050000 -0.050000 -0.100000 P R 0.012000 LINE -0.050000 -0.100000 0.050000 -0.100000 P R 0.012000 LINE 0.050000 -0.100000 0.100000 -0.050000 P R 0.012000 LINE 0.100000 -0.050000 0.100000 0.150000 P R 0.012000 LINE 0.100000 0.150000 0.050000 0.200000 P R 0.012000 LINE 0.050000 0.200000 -0.050000 0.200000 P R 0.012000 LINE -0.050000 0.200000 -0.100000 0.150000 P R 0.012000 LINE -0.100000 0.150000 -0.100000 -0.050000 P R 0.012000 LINE -0.100000 -0.050000 0.100000 0.150000 P R 0.012000 ECHAR CHAR 1 LINE -0.050000 0.150000 0.000000 0.200000 P R 0.012000 LINE 0.000000 0.200000 0.000000 -0.100000 P R 0.012000 LINE -0.050000 -0.100000 0.050000 -0.100000 P R 0.012000 ECHAR
CHAR 2
LINE -0.100000 0.150000 -0.050000 0.200000 P R 0.012000 LINE -0.050000 0.200000 0.050000 0.200000 P R 0.012000 LINE 0.050000 0.200000 0.100000 0.150000 P R 0.012000 LINE 0.100000 0.150000 0.100000 0.100000 P R 0.012000 LINE 0.100000 0.100000 0.050000 0.050000 P R 0.012000 LINE 0.050000 0.050000 0.000000 0.050000 P R 0.012000 LINE 0.000000 0.050000 -0.100000 -0.100000 P R 0.012000 LINE -0.100000 -0.100000 0.100000 -0.100000 P R 0.012000 ECHAR CHAR 3 LINE -0.100000 0.200000 0.100000 0.200000 P R 0.012000 LINE 0.100000 0.200000 0.100000 0.100000 P R 0.012000 LINE 0.100000 0.100000 0.050000 0.050000 P R 0.012000 LINE 0.050000 0.050000 0.000000 0.050000 P R 0.012000 LINE 0.050000 0.050000 0.100000 0.000000 P R 0.012000 LINE 0.100000 0.000000 0.100000 -0.050000 P R 0.012000 LINE 0.100000 -0.050000 0.050000 -0.100000 P R 0.012000 LINE 0.050000 -0.100000 -0.050000 -0.100000 P R 0.012000 LINE -0.050000 -0.100000 -0.100000 -0.050000 P R 0.012000 ECHAR CHAR 4 LINE 0.050000 -0.100000 0.050000 0.200000 P R 0.012000 LINE 0.050000 0.200000 -0.100000 0.000000 P R 0.012000 LINE -0.100000 0.000000 0.100000 0.000000 P R 0.012000 ECHAR CHAR 5 LINE 0.100000 0.200000 -0.100000 0.200000 P R 0.012000 LINE -0.100000 0.200000 -0.100000 0.100000 P R 0.012000 LINE -0.100000 0.100000 0.050000 0.100000 P R 0.012000 LINE 0.050000 0.100000 0.100000 0.050000 P R 0.012000 LINE 0.100000 0.050000 0.100000 -0.050000 P R 0.012000 LINE 0.100000 -0.050000 0.050000 -0.100000 P R 0.012000 LINE 0.050000 -0.100000 -0.050000 -0.100000 P R 0.012000 LINE -0.050000 -0.100000 -0.100000 -0.050000 P R 0.012000 ECHAR CHAR 6 LINE 0.100000 0.200000 0.000000 0.200000 P R 0.012000 LINE 0.000000 0.200000 -0.100000 0.100000 P R 0.012000 LINE -0.100000 0.100000 -0.100000 -0.050000 P R 0.012000 LINE -0.100000 -0.050000 -0.050000 -0.100000 P R 0.012000 LINE -0.050000 -0.100000 0.050000 -0.100000 P R 0.012000 LINE 0.050000 -0.100000 0.100000 -0.050000 P R 0.012000 LINE 0.100000 -0.050000 0.100000 0.000000 P R 0.012000 LINE 0.100000 0.000000 0.050000 0.050000 P R 0.012000 LINE 0.050000 0.050000 -0.100000 0.050000 P R 0.012000 ECHAR CHAR 7 LINE -0.100000 0.200000 0.100000 0.200000 P R 0.012000 LINE 0.100000 0.200000 -0.050000 -0.100000 P R 0.012000 ECHAR CHAR 8 LINE -0.050000 0.200000 0.050000 0.200000 P R 0.012000
LINE -0.050000 0.050000 0.050000 0.050000 P R 0.012000 LINE -0.050000 -0.100000 0.050000 -0.100000 P R 0.012000 LINE -0.100000 0.150000 -0.100000 0.100000 P R 0.012000 LINE 0.100000 0.150000 0.100000 0.100000 P R 0.012000 LINE -0.100000 0.000000 -0.100000 -0.050000 P R 0.012000 LINE 0.100000 0.000000 0.100000 -0.050000 P R 0.012000 LINE 0.050000 0.200000 0.100000 0.150000 P R 0.012000 LINE -0.050000 0.200000 -0.100000 0.150000 P R 0.012000 LINE 0.050000 0.050000 0.100000 0.100000 P R 0.012000 LINE -0.050000 0.050000 -0.100000 0.100000 P R 0.012000 LINE 0.050000 0.050000 0.100000 0.000000 P R 0.012000 LINE -0.050000 0.050000 -0.100000 0.000000 P R 0.012000 LINE 0.050000 -0.100000 0.100000 -0.050000 P R 0.012000 LINE -0.050000 -0.100000 -0.100000 -0.050000 P R 0.012000 ECHAR CHAR 9 LINE -0.100000 -0.100000 0.000000 -0.100000 P R 0.012000 LINE 0.000000 -0.100000 0.100000 0.000000 P R 0.012000 LINE 0.100000 0.000000 0.100000 0.150000 P R 0.012000 LINE 0.100000 0.150000 0.050000 0.200000 P R 0.012000 LINE 0.050000 0.200000 -0.050000 0.200000 P R 0.012000 LINE -0.050000 0.200000 -0.100000 0.150000 P R 0.012000 LINE -0.100000 0.150000 -0.100000 0.100000 P R 0.012000 LINE -0.100000 0.100000 -0.050000 0.050000 P R 0.012000 LINE -0.050000 0.050000 0.100000 0.050000 P R 0.012000 ECHAR CHAR : LINE 0.000000 -0.05000 0.000000 -0.05000 P R 0.012000 LINE 0.000000 0.15000 0.000000 0.15000 P R 0.012000 ECHAR CHAR ; LINE 0.000000 0.025000 -0.050000 -0.100000 P R 0.012000 LINE 0.000000 0.025000 0.000000 0.025000 P R 0.012000 LINE 0.000000 0.175000 0.000000 0.175000 P R 0.012000 ECHAR CHAR < LINE 0.100000 0.200000 -0.050000 0.050000 P R 0.012000 LINE -0.050000 0.050000 0.100000 -0.100000 P R 0.012000 ECHAR CHAR = LINE -0.100000 0.100000 0.100000 0.100000 P R 0.012000 LINE -0.100000 0.000000 0.100000 0.000000 P R 0.012000 ECHAR CHAR > LINE -0.100000 0.200000 0.050000 0.050000 P R 0.012000 LINE 0.050000 0.050000 -0.100000 -0.100000 P R 0.012000 ECHAR CHAR ? LINE -0.100000 0.150000 -0.050000 0.200000 P R 0.012000 LINE -0.050000 0.200000 0.050000 0.200000 P R 0.012000 LINE 0.050000 0.200000 0.100000 0.150000 P R 0.012000
LINE 0.100000 0.150000 0.000000 0.050000 P R 0.012000 LINE 0.000000 0.050000 0.000000 0.000000 P R 0.012000 LINE 0.000000 -0.100000 0.000000 -0.100000 P R 0.012000 ECHAR CHAR @ LINE 0.050000 -0.100000 -0.050000 -0.100000 P R 0.012000 LINE -0.050000 -0.100000 -0.100000 -0.050000 P R 0.012000 LINE -0.100000 -0.050000 -0.100000 0.150000 P R 0.012000 LINE -0.100000 0.150000 -0.050000 0.200000 P R 0.012000 LINE -0.050000 0.200000 0.050000 0.200000 P R 0.012000 LINE 0.050000 0.200000 0.100000 0.150000 P R 0.012000 LINE 0.100000 0.150000 0.100000 0.000000 P R 0.012000 LINE 0.100000 0.000000 0.000000 0.000000 P R 0.012000 LINE 0.000000 0.000000 0.000000 0.100000 P R 0.012000 LINE 0.000000 0.100000 0.100000 0.100000 P R 0.012000 ECHAR CHAR A LINE -0.100000 -0.100000 -0.100000 0.150000 P R 0.012000 LINE -0.100000 0.150000 -0.050000 0.200000 P R 0.012000 LINE -0.050000 0.200000 0.050000 0.200000 P R 0.012000 LINE 0.050000 0.200000 0.100000 0.150000 P R 0.012000 LINE 0.100000 0.150000 0.100000 -0.100000 P R 0.012000 LINE -0.100000 0.050000 0.100000 0.050000 P R 0.012000 ECHAR CHAR B LINE -0.100000 0.200000 0.050000 0.200000 P R 0.012000 LINE 0.050000 0.200000 0.100000 0.150000 P R 0.012000 LINE 0.100000 0.150000 0.100000 0.100000 P R 0.012000 LINE 0.100000 0.100000 0.050000 0.050000 P R 0.012000 LINE 0.050000 0.050000 0.100000 0.000000 P R 0.012000 LINE 0.100000 0.000000 0.100000 -0.050000 P R 0.012000 LINE 0.100000 -0.050000 0.050000 -0.100000 P R 0.012000 LINE 0.050000 -0.100000 -0.100000 -0.100000 P R 0.012000 LINE -0.050000 -0.100000 -0.050000 0.200000 P R 0.012000 LINE -0.050000 0.050000 0.050000 0.050000 P R 0.012000 ECHAR CHAR C LINE 0.100000 -0.050000 0.050000 -0.100000 P R 0.012000 LINE 0.050000 -0.100000 -0.050000 -0.100000 P R 0.012000 LINE -0.050000 -0.100000 -0.100000 -0.050000 P R 0.012000 LINE -0.100000 -0.050000 -0.100000 0.150000 P R 0.012000 LINE -0.100000 0.150000 -0.050000 0.200000 P R 0.012000 LINE -0.050000 0.200000 0.050000 0.200000 P R 0.012000 LINE 0.050000 0.200000 0.100000 0.150000 P R 0.012000 ECHAR CHAR D LINE -0.100000 0.200000 0.050000 0.200000 P R 0.012000 LINE 0.050000 0.200000 0.100000 0.150000 P R 0.012000 LINE 0.100000 0.150000 0.100000 -0.050000 P R 0.012000 LINE 0.100000 -0.050000 0.050000 -0.100000 P R 0.012000 LINE 0.050000 -0.100000 -0.100000 -0.100000 P R 0.012000 LINE -0.050000 -0.100000 -0.050000 0.200000 P R 0.012000 ECHAR
CHAR E
LINE -0.100000 0.200000 0.100000 0.200000 P R 0.012000
LINE -0.100000 -0.100000 0.100000 -0.100000 P R 0.012000 LINE -0.100000 0.050000 0.050000 0.050000 P R 0.012000 LINE -0.100000 0.200000 -0.100000 -0.100000 P R 0.012000 ECHAR CHAR F LINE -0.100000 0.200000 0.100000 0.200000 P R 0.012000 LINE -0.100000 0.050000 0.050000 0.050000 P R 0.012000 LINE -0.100000 0.200000 -0.100000 -0.100000 P R 0.012000 ECHAR CHAR G LINE -0.050000 0.200000 0.100000 0.200000 P R 0.012000 LINE -0.050000 0.200000 -0.100000 0.150000 P R 0.012000 LINE -0.100000 0.150000 -0.100000 -0.050000 P R 0.012000 LINE -0.100000 -0.050000 -0.050000 -0.100000 P R 0.012000 LINE -0.050000 -0.100000 0.100000 -0.100000 P R 0.012000 LINE 0.100000 -0.100000 0.100000 0.050000 P R 0.012000 LINE 0.100000 0.050000 0.050000 0.050000 P R 0.012000 ECHAR CHAR H LINE -0.100000 0.200000 -0.100000 -0.100000 P R 0.012000 LINE 0.100000 0.200000 0.100000 -0.100000 P R 0.012000 LINE -0.100000 0.050000 0.100000 0.050000 P R 0.012000 ECHAR CHAR I LINE -0.050000 0.200000 0.050000 0.200000 P R 0.012000 LINE -0.050000 -0.100000 0.050000 -0.100000 P R 0.012000 LINE 0.000000 0.200000 0.000000 -0.100000 P R 0.012000 ECHAR CHAR J LINE 0.100000 0.200000 0.100000 -0.050000 P R 0.012000 LINE 0.100000 -0.050000 0.050000 -0.100000 P R 0.012000 LINE 0.050000 -0.100000 -0.050000 -0.100000 P R 0.012000 LINE -0.050000 -0.100000 -0.100000 -0.050000 P R 0.012000 ECHAR CHAR K LINE -0.100000 0.200000 -0.100000 -0.100000 P R 0.012000 LINE 0.100000 0.200000 -0.100000 0.050000 P R 0.012000 LINE -0.100000 0.050000 0.100000 -0.100000 P R 0.012000 ECHAR CHAR L LINE -0.100000 0.200000 -0.100000 -0.100000 P R 0.012000 LINE -0.100000 -0.100000 0.100000 -0.100000 P R 0.012000 ECHAR CHAR M LINE -0.100000 -0.100000 -0.100000 0.200000 P R 0.012000 LINE -0.100000 0.200000 0.000000 0.050000 P R 0.012000 LINE 0.000000 0.050000 0.100000 0.200000 P R 0.012000
LINE 0.100000 0.200000 0.100000 -0.100000 P R 0.012000 ECHAR CHAR N LINE -0.100000 -0.100000 -0.100000 0.200000 P R 0.012000 LINE -0.100000 0.200000 0.100000 -0.100000 P R 0.012000 LINE 0.100000 -0.100000 0.100000 0.200000 P R 0.012000 ECHAR CHAR O LINE -0.100000 -0.050000 -0.100000 0.150000 P R 0.012000 LINE -0.100000 0.150000 -0.050000 0.200000 P R 0.012000 LINE -0.050000 0.200000 0.050000 0.200000 P R 0.012000 LINE 0.050000 0.200000 0.100000 0.150000 P R 0.012000 LINE 0.100000 0.150000 0.100000 -0.050000 P R 0.012000 LINE 0.100000 -0.050000 0.050000 -0.100000 P R 0.012000 LINE 0.050000 -0.100000 -0.050000 -0.100000 P R 0.012000 LINE -0.050000 -0.100000 -0.100000 -0.050000 P R 0.012000 ECHAR CHAR P LINE -0.100000 -0.100000 -0.100000 0.200000 P R 0.012000 LINE -0.100000 0.200000 0.050000 0.200000 P R 0.012000 LINE 0.050000 0.200000 0.100000 0.150000 P R 0.012000 LINE 0.100000 0.150000 0.100000 0.100000 P R 0.012000 LINE 0.100000 0.100000 0.050000 0.050000 P R 0.012000 LINE 0.050000 0.050000 -0.100000 0.050000 P R 0.012000 ECHAR CHAR Q LINE -0.100000 -0.050000 -0.100000 0.150000 P R 0.012000 LINE -0.100000 0.150000 -0.050000 0.200000 P R 0.012000 LINE -0.050000 0.200000 0.050000 0.200000 P R 0.012000 LINE 0.050000 0.200000 0.100000 0.150000 P R 0.012000 LINE 0.100000 0.150000 0.100000 0.000000 P R 0.012000 LINE 0.100000 0.000000 0.000000 -0.100000 P R 0.012000 LINE 0.000000 -0.100000 -0.050000 -0.100000 P R 0.012000 LINE -0.050000 -0.100000 -0.100000 -0.050000 P R 0.012000 LINE 0.000000 0.000000 0.100000 -0.100000 P R 0.012000 ECHAR CHAR R LINE -0.100000 -0.100000 -0.100000 0.200000 P R 0.012000 LINE -0.100000 0.200000 0.050000 0.200000 P R 0.012000 LINE 0.050000 0.200000 0.100000 0.150000 P R 0.012000 LINE 0.100000 0.150000 0.100000 0.100000 P R 0.012000 LINE 0.100000 0.100000 0.050000 0.050000 P R 0.012000 LINE 0.050000 0.050000 -0.100000 0.050000 P R 0.012000 LINE -0.050000 0.050000 0.100000 -0.100000 P R 0.012000 ECHAR CHAR S LINE -0.100000 -0.050000 -0.050000 -0.100000 P R 0.012000 LINE -0.050000 -0.100000 0.050000 -0.100000 P R 0.012000 LINE 0.050000 -0.100000 0.100000 -0.050000 P R 0.012000 LINE 0.100000 -0.050000 0.100000 0.000000 P R 0.012000 LINE 0.100000 0.000000 0.050000 0.050000 P R 0.012000 LINE 0.050000 0.050000 -0.050000 0.050000 P R 0.012000
LINE -0.050000 0.050000 -0.100000 0.100000 P R 0.012000 LINE -0.100000 0.100000 -0.100000 0.150000 P R 0.012000 LINE -0.100000 0.150000 -0.050000 0.200000 P R 0.012000 LINE -0.050000 0.200000 0.050000 0.200000 P R 0.012000 LINE 0.050000 0.200000 0.100000 0.150000 P R 0.012000 ECHAR CHAR T LINE -0.100000 0.200000 0.100000 0.200000 P R 0.012000 LINE 0.000000 0.200000 0.000000 -0.100000 P R 0.012000 ECHAR CHAR U LINE -0.100000 0.200000 -0.100000 -0.050000 P R 0.012000 LINE -0.100000 -0.050000 -0.050000 -0.100000 P R 0.012000 LINE -0.050000 -0.100000 0.050000 -0.100000 P R 0.012000 LINE 0.050000 -0.100000 0.100000 -0.050000 P R 0.012000 LINE 0.100000 -0.050000 0.100000 0.200000 P R 0.012000 ECHAR CHAR V LINE -0.100000 0.200000 0.000000 -0.100000 P R 0.012000 LINE 0.000000 -0.100000 0.100000 0.200000 P R 0.012000 ECHAR CHAR W LINE -0.100000 0.200000 -0.100000 -0.100000 P R 0.012000 LINE -0.100000 -0.100000 0.000000 0.050000 P R 0.012000 LINE 0.000000 0.050000 0.100000 -0.100000 P R 0.012000 LINE 0.100000 -0.100000 0.100000 0.200000 P R 0.012000 ECHAR CHAR X LINE -0.100000 0.200000 0.100000 -0.100000 P R 0.012000 LINE -0.100000 -0.100000 0.100000 0.200000 P R 0.012000 ECHAR CHAR Y LINE -0.100000 0.200000 0.000000 0.050000 P R 0.012000 LINE 0.000000 0.050000 0.100000 0.200000 P R 0.012000 LINE 0.000000 0.050000 0.000000 -0.100000 P R 0.012000 ECHAR CHAR Z LINE -0.100000 0.200000 0.100000 0.200000 P R 0.012000 LINE 0.100000 0.200000 -0.100000 -0.100000 P R 0.012000 LINE -0.100000 -0.100000 0.100000 -0.100000 P R 0.012000 ECHAR CHAR [ LINE 0.050000 0.200000 -0.050000 0.200000 P R 0.012000 LINE -0.050000 0.200000 -0.050000 -0.100000 P R 0.012000 LINE -0.050000 -0.100000 0.050000 -0.100000 P R 0.012000 ECHAR CHAR \ LINE -0.100000 0.200000 0.100000 -0.100000 P R 0.012000 ECHAR
CHAR ] LINE -0.050000 0.200000 0.050000 0.200000 P R 0.012000 LINE 0.050000 0.200000 0.050000 -0.100000 P R 0.012000 LINE 0.050000 -0.100000 -0.050000 -0.100000 P R 0.012000 ECHAR CHAR ^ LINE -0.100000 0.100000 0.000000 0.200000 P R 0.012000 LINE 0.000000 0.200000 0.100000 0.100000 P R 0.012000 ECHAR CHAR _ LINE -0.100000 -0.100000 0.100000 -0.100000 P R 0.012000 ECHAR CHAR ` LINE -0.050000 0.200000 0.000000 0.050000 P R 0.012000 ECHAR CHAR a LINE -0.050000 0.100000 0.050000 0.100000 P R 0.012000 LINE 0.050000 0.100000 0.100000 0.050000 P R 0.012000 LINE 0.100000 0.050000 0.100000 -0.100000 P R 0.012000 LINE 0.100000 -0.100000 -0.050000 -0.100000 P R 0.012000 LINE -0.050000 -0.100000 -0.100000 -0.050000 P R 0.012000 LINE -0.100000 -0.050000 -0.050000 0.000000 P R 0.012000 LINE -0.050000 0.000000 0.100000 0.000000 P R 0.012000 ECHAR CHAR b LINE -0.100000 0.200000 -0.100000 -0.100000 P R 0.012000 LINE -0.100000 -0.100000 0.050000 -0.100000 P R 0.012000 LINE 0.050000 -0.100000 0.100000 -0.050000 P R 0.012000 LINE 0.100000 -0.050000 0.100000 0.050000 P R 0.012000 LINE 0.100000 0.050000 0.050000 0.100000 P R 0.012000 LINE 0.050000 0.100000 0.000000 0.100000 P R 0.012000 LINE 0.000000 0.100000 -0.100000 0.050000 P R 0.012000 ECHAR CHAR c LINE 0.100000 0.100000 -0.050000 0.100000 P R 0.012000 LINE -0.050000 0.100000 -0.100000 0.050000 P R 0.012000 LINE -0.100000 0.050000 -0.100000 -0.050000 P R 0.012000 LINE -0.100000 -0.050000 -0.050000 -0.100000 P R 0.012000 LINE -0.050000 -0.100000 0.100000 -0.100000 P R 0.012000 ECHAR CHAR d LINE 0.100000 0.200000 0.100000 -0.100000 P R 0.012000 LINE 0.100000 -0.100000 -0.050000 -0.100000 P R 0.012000 LINE -0.050000 -0.100000 -0.100000 -0.050000 P R 0.012000 LINE -0.100000 -0.050000 -0.100000 0.050000 P R 0.012000 LINE -0.100000 0.050000 -0.050000 0.100000 P R 0.012000 LINE -0.050000 0.100000 0.000000 0.100000 P R 0.012000 LINE 0.000000 0.100000 0.100000 0.050000 P R 0.012000 ECHAR
CHAR e LINE 0.050000 -0.100000 -0.050000 -0.100000 P R 0.012000 LINE -0.050000 -0.100000 -0.100000 -0.050000 P R 0.012000 LINE -0.100000 -0.050000 -0.100000 0.050000 P R 0.012000 LINE -0.100000 0.050000 -0.050000 0.100000 P R 0.012000 LINE -0.050000 0.100000 0.050000 0.100000 P R 0.012000 LINE 0.050000 0.100000 0.100000 0.050000 P R 0.012000 LINE 0.100000 0.050000 0.050000 0.000000 P R 0.012000 LINE 0.050000 0.000000 -0.100000 0.000000 P R 0.012000 ECHAR CHAR f LINE -0.050000 -0.100000 -0.050000 0.150000 P R 0.012000 LINE -0.050000 0.150000 0.000000 0.200000 P R 0.012000 LINE 0.000000 0.200000 0.050000 0.200000 P R 0.012000 LINE 0.050000 0.200000 0.100000 0.150000 P R 0.012000 LINE -0.100000 0.050000 0.000000 0.050000 P R 0.012000 ECHAR CHAR g LINE -0.050000 -0.150000 0.050000 -0.150000 P R 0.012000 LINE 0.050000 -0.150000 0.100000 -0.100000 P R 0.012000 LINE 0.100000 -0.100000 0.100000 0.050000 P R 0.012000 LINE 0.100000 0.050000 0.050000 0.100000 P R 0.012000 LINE 0.050000 0.100000 -0.050000 0.100000 P R 0.012000 LINE -0.050000 0.100000 -0.100000 0.050000 P R 0.012000 LINE -0.100000 0.050000 -0.100000 0.000000 P R 0.012000 LINE -0.100000 0.000000 -0.050000 -0.050000 P R 0.012000 LINE -0.050000 -0.050000 0.100000 -0.050000 P R 0.012000 ECHAR CHAR h LINE -0.100000 0.200000 -0.100000 -0.100000 P R 0.012000 LINE -0.100000 0.050000 0.000000 0.100000 P R 0.012000 LINE 0.000000 0.100000 0.050000 0.100000 P R 0.012000 LINE 0.050000 0.100000 0.100000 0.050000 P R 0.012000 LINE 0.100000 0.050000 0.100000 -0.100000 P R 0.012000 ECHAR CHAR i LINE 0.000000 0.100000 0.000000 -0.050000 P R 0.012000 LINE 0.000000 -0.050000 0.050000 -0.100000 P R 0.012000 LINE 0.000000 0.200000 0.000000 0.200000 P R 0.012000 ECHAR CHAR j LINE 0.050000 0.100000 0.050000 -0.100000 P R 0.012000 LINE 0.050000 -0.100000 0.000000 -0.150000 P R 0.012000 LINE 0.000000 -0.150000 -0.050000 -0.150000 P R 0.012000 LINE -0.050000 -0.150000 -0.100000 -0.100000 P R 0.012000 LINE 0.050000 0.200000 0.050000 0.200000 P R 0.012000 ECHAR CHAR k LINE -0.100000 0.200000 -0.100000 -0.100000 P R 0.012000 LINE -0.100000 0.000000 0.000000 0.000000 P R 0.012000 LINE 0.000000 0.000000 0.100000 -0.100000 P R 0.012000 LINE -0.050000 0.000000 0.050000 0.100000 P R 0.012000
ECHAR
CHAR l LINE -0.050000 0.200000 0.000000 0.200000 P R 0.012000 LINE 0.000000 0.200000 0.000000 -0.050000 P R 0.012000 LINE 0.000000 -0.050000 0.050000 -0.100000 P R 0.012000 ECHAR CHAR m LINE -0.100000 -0.100000 -0.100000 0.050000 P R 0.012000 LINE -0.100000 0.050000 -0.050000 0.100000 P R 0.012000 LINE -0.050000 0.100000 0.000000 0.050000 P R 0.012000 LINE 0.000000 0.050000 0.000000 0.000000 P R 0.012000 LINE 0.000000 0.050000 0.050000 0.100000 P R 0.012000 LINE 0.050000 0.100000 0.100000 0.050000 P R 0.012000 LINE 0.100000 0.050000 0.100000 -0.100000 P R 0.012000 ECHAR CHAR n LINE -0.100000 0.100000 -0.100000 -0.100000 P R 0.012000 LINE -0.100000 0.000000 0.000000 0.100000 P R 0.012000 LINE 0.000000 0.100000 0.050000 0.100000 P R 0.012000 LINE 0.050000 0.100000 0.100000 0.050000 P R 0.012000 LINE 0.100000 0.050000 0.100000 -0.100000 P R 0.012000 ECHAR CHAR o LINE -0.100000 -0.050000 -0.100000 0.050000 P R 0.012000 LINE -0.100000 0.050000 -0.050000 0.100000 P R 0.012000 LINE -0.050000 0.100000 0.050000 0.100000 P R 0.012000 LINE 0.050000 0.100000 0.100000 0.050000 P R 0.012000 LINE 0.100000 0.050000 0.100000 -0.050000 P R 0.012000 LINE 0.100000 -0.050000 0.050000 -0.100000 P R 0.012000 LINE 0.050000 -0.100000 -0.050000 -0.100000 P R 0.012000 LINE -0.050000 -0.100000 -0.100000 -0.050000 P R 0.012000 ECHAR CHAR p LINE -0.100000 -0.150000 -0.100000 0.050000 P R 0.012000 LINE -0.100000 0.050000 -0.050000 0.100000 P R 0.012000 LINE -0.050000 0.100000 0.050000 0.100000 P R 0.012000 LINE 0.050000 0.100000 0.100000 0.050000 P R 0.012000 LINE 0.100000 0.050000 0.100000 0.000000 P R 0.012000 LINE 0.100000 0.000000 0.050000 -0.050000 P R 0.012000 LINE 0.050000 -0.050000 -0.100000 -0.050000 P R 0.012000 ECHAR CHAR q LINE 0.100000 -0.150000 0.100000 0.050000 P R 0.012000 LINE 0.100000 0.050000 0.050000 0.100000 P R 0.012000 LINE 0.050000 0.100000 -0.050000 0.100000 P R 0.012000 LINE -0.050000 0.100000 -0.100000 0.050000 P R 0.012000 LINE -0.100000 0.050000 -0.100000 0.000000 P R 0.012000 LINE -0.100000 0.000000 -0.050000 -0.050000 P R 0.012000 LINE -0.050000 -0.050000 0.100000 -0.050000 P R 0.012000 ECHAR
CHAR r
LINE -0.100000 0.100000 -0.100000 -0.100000 P R 0.012000 LINE -0.100000 0.000000 0.000000 0.100000 P R 0.012000 LINE 0.000000 0.100000 0.050000 0.050000 P R 0.012000 ECHAR CHAR s LINE -0.100000 -0.100000 0.050000 -0.100000 P R 0.012000 LINE 0.050000 -0.100000 0.100000 -0.050000 P R 0.012000 LINE 0.100000 -0.050000 0.050000 0.000000 P R 0.012000 LINE 0.050000 0.000000 -0.050000 0.000000 P R 0.012000 LINE -0.050000 0.000000 -0.100000 0.050000 P R 0.012000 LINE -0.100000 0.050000 -0.050000 0.100000 P R 0.012000 LINE -0.050000 0.100000 0.100000 0.100000 P R 0.012000 ECHAR CHAR t LINE -0.050000 0.200000 -0.050000 -0.050000 P R 0.012000 LINE -0.050000 -0.050000 0.000000 -0.100000 P R 0.012000 LINE 0.000000 -0.100000 0.050000 -0.100000 P R 0.012000 LINE 0.050000 -0.100000 0.100000 -0.050000 P R 0.012000 LINE -0.100000 0.100000 0.050000 0.100000 P R 0.012000 ECHAR CHAR u LINE -0.100000 0.100000 -0.100000 -0.050000 P R 0.012000 LINE -0.100000 -0.050000 -0.050000 -0.100000 P R 0.012000 LINE -0.050000 -0.100000 0.000000 -0.100000 P R 0.012000 LINE 0.000000 -0.100000 0.100000 0.000000 P R 0.012000 LINE 0.100000 -0.100000 0.100000 0.100000 P R 0.012000 ECHAR CHAR v LINE -0.100000 0.100000 0.000000 -0.100000 P R 0.012000 LINE 0.000000 -0.100000 0.100000 0.100000 P R 0.012000 ECHAR CHAR w LINE -0.100000 0.100000 -0.050000 -0.100000 P R 0.012000 LINE -0.050000 -0.100000 0.000000 0.000000 P R 0.012000 LINE 0.000000 0.000000 0.050000 -0.100000 P R 0.012000 LINE 0.050000 -0.100000 0.100000 0.100000 P R 0.012000 ECHAR CHAR x LINE -0.100000 0.100000 0.100000 -0.100000 P R 0.012000 LINE -0.100000 -0.100000 0.100000 0.100000 P R 0.012000 ECHAR CHAR y LINE -0.100000 0.100000 -0.100000 0.000000 P R 0.012000 LINE -0.100000 0.000000 -0.050000 -0.050000 P R 0.012000 LINE -0.050000 -0.050000 0.100000 -0.050000 P R 0.012000 LINE 0.100000 0.100000 0.100000 -0.100000 P R 0.012000 LINE 0.100000 -0.100000 0.050000 -0.150000 P R 0.012000 LINE 0.050000 -0.150000 -0.050000 -0.150000 P R 0.012000 ECHAR
CHAR z
LINE -0.100000 0.100000 0.100000 0.100000 P R 0.012000 LINE 0.100000 0.100000 -0.100000 -0.100000 P R 0.012000 LINE -0.100000 -0.100000 0.100000 -0.100000 P R 0.012000 ECHAR CHAR { LINE 0.050000 0.200000 0.000000 0.200000 P R 0.012000 LINE 0.000000 0.200000 -0.050000 0.150000 P R 0.012000 LINE -0.050000 0.150000 -0.050000 0.100000 P R 0.012000 LINE -0.050000 0.100000 -0.100000 0.050000 P R 0.012000 LINE -0.100000 0.050000 -0.050000 0.000000 P R 0.012000 LINE -0.050000 0.000000 -0.050000 -0.050000 P R 0.012000 LINE -0.050000 -0.050000 0.000000 -0.100000 P R 0.012000 LINE 0.000000 -0.100000 0.050000 -0.100000 P R 0.012000 ECHAR CHAR | LINE 0.000000 0.200000 0.000000 -0.100000 P R 0.012000 ECHAR CHAR } LINE -0.050000 0.200000 0.000000 0.200000 P R 0.012000 LINE 0.000000 0.200000 0.050000 0.150000 P R 0.012000 LINE 0.050000 0.150000 0.050000 0.100000 P R 0.012000 LINE 0.050000 0.100000 0.100000 0.050000 P R 0.012000 LINE 0.100000 0.050000 0.050000 0.000000 P R 0.012000 LINE 0.050000 0.000000 0.050000 -0.050000 P R 0.012000 LINE 0.050000 -0.050000 0.000000 -0.100000 P R 0.012000 LINE 0.000000 -0.100000 -0.050000 -0.100000 P R 0.012000 ECHAR CHAR ~ LINE -0.100000 0.150000 -0.050000 0.200000 P R 0.012000 LINE -0.050000 0.200000 0.050000 0.100000 P R 0.012000 LINE 0.050000 0.100000 0.100000 0.150000 P R 0.012000 ECHAR
Appendix D Metadata Content, Example, and Schema
Product model metadata can be supplied in a metadata.xml file.
See 'misc/metadata.xml (Metadata)' on page 79.
| Metadata Content . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 300 | |--------------------------------------------------------------------------------------------------------------------------|-------| | Header Metadata Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 300 | | Requirements Metadata Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 301 | | Manufacturing Metadata Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 306 | | Assembly Metadata Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 310 | | Final Metadata Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 311 | | Metadata Example. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 312 | | Metadata Schema. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 316 |
Metadata Content
These node tags are supported by ODB++, and cannot be modified by a user. The tags are placed in the appropriate section of the metadata.xml file.
| Header Metadata Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 300 | |------------------------------------------------------------------------------------------------------------------------------|-------| | Requirements Metadata Section. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 301 | | Manufacturing Metadata Section. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 306 | | Assembly Metadata Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 310 | | Final Metadata Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 311 |
Header Metadata Section
These are the tags in the header section.
Table D-1. Metadata Content - Header Section
| Name | Description | Display Name | Type | Entity Level | |--------------------------|----------------------------------------------------------|-------------------------|---------|----------------| | buried_capacitor | Indicates whether this board contains buried capacitors. | Buried Capacitor | Boolean | product model | | buried_resistor | Indicates whether this board contains buried resistors. | Buried Resistor | Boolean | product model | | company_address | Company address. | Company Address | Text | product model | | company_name | Company name. | Company Name | Text | product model | | counter_bore | Indicates whether the board contains counter bore holes. | Counter Bore | Boolean | product model | | countersink | Indicates whether the board contains countersink holes. | Counter Sink | Boolean | product model | | customer_control_n umber | Revision control number assigned by the customer. | Customer Control Number | Text | product model | | designer_email | Email address of designer. | Designer Email | Text | product model | | designer_name | Name of designer. | Designer Name | Text | product model | | designer_phone_nu mber | Phone number of the designer. | Phone Number | Text | product model |
Table D-1. Metadata Content - Header Section (cont.)
| Name | Description | Display Name | Type | Entity Level | |-----------------------------|-------------------------------------------------------------------------------|------------------------------------------------|------------------|----------------| | direct_connections_ present | Indicates that direct connections to plans are known to exist. | Direct Connections Present | Boolean | step | | edge_connectors | Indicates whether this board contains edge connectors. | Edge Connectors | Boolean | product model | | layer_count | Number of copper layers in the board/panel. | Layer Count | Integer | product model | | layout_name | Layout name. | Layout Name | Text | product model | | part_x_size | Part size in the Xdirection. | Part X Size | Float (Distance) | step | | part_y_size | Part size in the Ydirection. | Part Y Size | Float (Distance) | step | | pcb_part_number | Part number assigned to the PCB. | PCB Part Number | Text | product model | | rohs_compliant | Indicates whether the process to produce the board or panel is ROHS compliant | RoHS Compliant | Boolean | product model | | ruling_ipc_spec | (Class 1, Class 2, Class 3, ...) IPC classification | Ruling IPC Specification (Class 1, 2, 3, etc.) | Option | product model | | stacked_vias_presen t | (yes/no) Indicates whether stacked vias are present. | Stacked Vias Present | Boolean | step | | revision | (0-64 characters) Revision of this part. | Revision | Text | product model |
Requirements Metadata Section
These are the tags in the requirements section.
Table D-2. Metadata Content - Requirements
| Name | Description | Display Name | Type | Entity Level | |--------------------------------|-------------------------------------------------------------------------------------------------------------------|--------------------------------------|-------------------|----------------| | additional_copper_ly r_require | Other requirements. | Additional Copper Layer Requirements | Text | step | | additional_requirem ents | Other requirements. | Additional Requirements | Text | product model | | board_outline_tolera nce_minus | Minus tolerance for board outline. | Board Outline Tolerance Minus | Float (Distance) | product model | | board_outline_tolera nce_plus | Plus tolerance for board outline. | Board Outline Tolerance Plus | Float (Distance) | product model | | board_thickness | Thickness of board. | Board Thickness | Float (Distance) | product model | | board_thickness_tol _minus | Minus tolerance for board thickness. | Board Thickness Tol Minus | Float (Distance) | product model | | board_thickness_tol plus | Plus tolerance for board thickness. | Board Thickness Tol Plus | Float (Distance) | product model | | board_thickness_typ e | (on foil, laminate, plated copper, mask on plated copper) Defines how the board thickness is measured/ specified. | Board Thickness Type | Text With Options | product model | | bottom_legend_colo r | (white, yellow) Color of the silkscreen or legend on the bottom side of the design. | Bottom Legend Color | Text With Options | product model | | bottom_soldermask color | (green, red, blue) Color of the soldermask on the bottom side of the design. | Bottom Soldermask Color | Text With Options | product model |
Table D-2. Metadata Content - Requirements (cont.)
| Name | Description | Display Name | Type | Entity Level | |------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------|---------------------|----------------| | flammability_rating_ standard | (UL 94, UL 94V-O) Materials used in the fabrication of a printed circuit board design should have one of these flammability ratings. | Flammability Rating Standard | Option | product model | | general_pcb_standar d | General PCB standard. | General PCB Standard | Text | product model | | glass_transition_tem perature_tg | Degree fahrenheit / Celsius | Glass Transition Temperature (Tg) | Float (Temperature) | product model | | gold_plating_thickne ss_max | Required Max gold plating thickness. | Gold Plating Thickness Max | Float (Distance) | step | | gold_plating_thickne ss_min | Required minimum gold plating thickness. | Gold Plating Thickness Min | Float (Distance) | step | | hole_position_minus _tolerance | Minus tolerance for hole positions. | Hole Position Min Tolerance | Float (Distance) | step | | hole_position_plus_t olerance | Plus tolerance for hole positions. | Hole Position Plus Tolerance | Float (Distance) | step | | identify_soldermask _define_pads_that_n eed_to_remain_unto uched | Defines whether the open area of soldermask defining a pad should remain unedited. | Identify Soldermask Defined Pads to Remain Untouched | Boolean | step | | legend_clearance_fr om_component_pad s | Minimum spacing between legend and edge of copper component pads. | Legend Clearance from Component Pads | Float (Distance) | step | | legend_clearance_fr om_soldermask_clea rance | Minimum spacing between legend and edge of soldermask clearances. | Legend Clearance from Soldermask Clearance | Float (Distance) | step |
Table D-2. Metadata Content - Requirements (cont.)
| Name | Description | Display Name | Type | Entity Level | |-----------------------------------------|----------------------------------------------------------------------------------------|-------------------------------------------|---------------------|----------------| | legend_clearance_fr om_test_points | Minimum spacing between legend and edge of copper test pads. | Legend Clearance from Test Points | Float (Distance) | step | | legend_sides | (none, top, bottom, both) Sides of the board on which legend printing must be applied. | Legend Sides | Option | product model | | lyr_to_lyr_reg_max_ tolerance | Maximum tolerance for layer to layer registration of copper layers. | Layer to Layer Registration Max Tolerance | Float (Distance) | step | | max_bow_and_twist _of_the_pcb | Maximum bow and twist requirement for this part. | Max Bow and Twist of PCB | Float (Distance) | step | | max_operating_temp erature | Maximum operating temperature. | MaxOperating Temperature | Float (Temperature) | product model | | min_ar_blind_via | Minimum AR requirement for blind via holes. | Min AR Blind Via | Float (Distance) | step | | min_ar_buried_via | Minimum AR requirement for buried via holes. | Min AR Buried Via | Float (Distance) | step | | min_ar_pressfit_pth | Minimum AR requirement for Pressfit PTH. | Min AR Pressfit PTH | Float (Distance) | step | | min_ar_pth | Minimum AR requirement for PTH. | Min AR PTH | Float (Distance) | step | | min_ar_via | Minimum AR requirement for Via holes. | Min AR Via | Float (Distance) | step | | min_copper_to_boar d_edge | Minimum spacing between copper and board edge. | Min Copper to Board Edge | Float (Distance) | step | | min_hole_to_edge | Minimum hole to board edge spacing. | Min Hole To Edge | Float (Distance) | step | | min_hole_to_hole | Minimum hole to hole spacing. | Min Hole To Hole | Float (Distance) | step | | min_soldermask_cle arance_for_bga_pad s | Minimum soldermask clearance for BGA pads. | Min Soldermask Clearance for BGA Pads | Float (Distance) | step |
Table D-2. Metadata Content - Requirements (cont.)
| Name | Description | Display Name | Type | Entity Level | |-----------------------------------------|-------------------------------------------------------------------------------------------------------------------------|----------------------------------------|------------------|----------------| | min_soldermask_cle arance_for_npth | Minimum soldermask clearance for NPTH drills. | Min Soldermask Clearance for NPTH | Float (Distance) | step | | min_soldermask_cle arance_for_pth_pads | Minimum soldermask clearance for plated TH pads. | Min Soldermask Clearance for PTH Pads | Float (Distance) | step | | min_soldermask_cle arance_for_smd_pad s | Minimum soldermask clearance for SMD pads. | Min Soldermask Clearance for SMD Pads | Float (Distance) | step | | pcb_acceptability_st andard | Standard for tolerances in the board. | PCB Acceptability Standard | Text | product model | | peelable_mask_side | (none, top, bottom, both) Indicates whether peelable mask needs to be applied on this board, and if so, on which sides. | Peelable Mask Side | Option | product model | | plated_edge | Indicates whether this job contains plated edges. | Plated Edge | Boolean | product model | | plated_slots | Indicates whether this job contains plated slots. | Plated Slots | Boolean | product model | | qualification_perfor mance_std | Qualification and performance standard (free text). | Qualification and Performance Standard | Text | product model | | soldermask_sides | (none, top, bottom, both) Indicates on which sides of the board soldermask must be applied. | Soldermask Sides | Option | product model | | thermal_stress_requi rement | Thermal stress requirements for the board. | Thermal Stress Requirement | Text | product model | | tolerance_standard | Standard for tolerances in the board. | Tolerance Standard | Text | product model |
Table D-2. Metadata Content - Requirements (cont.)
| Name | Description | Display Name | Type | Entity Level | |-----------------------|-------------------------------------------------------------------------------------------------------|----------------------|-------------------|----------------| | top_legend_color | (white, yellow) Color of the silkscreen or legend on the top side of the design. | Top Legend Color | Text With Options | product model | | top_soldermask_col or | (none, green, white, yellow, black, blue, red) Color of the soldermask on the top side of the design. | Top Soldermask Color | Text With Options | product model |
Manufacturing Metadata Section
These are the tags in the manufacturing section.
Table D-3. Metadata Content - Manufacturing
| Name | Description | Display Name | Type | Entity Level | |-----------------------------------|-----------------------------------------------------------------|----------------------------------------|------------------|----------------| | allowed_remove_nfp | Indicates whether it is allowed to remove non- functional pads. | Allowed To Remove Non- functional Pads | Boolean | step | | barrel_cu_thickness_ blind_via | Required copper thickness in the barrel of blind via holes. | Barrel Cu Thickness Blind Via | Float (Distance) | step | | barrel_cu_thickness_ buried_via | Required copper thickness in the barrel of buried via holes. | Barrel Cu Thickness Buried Via | Float (Distance) | step | | barrel_cu_thickness_ pressfit_pth | Required copper thickness in the barrel of Pressfit holes. | Barrel Cu Thickness Pressfit PTH | Float (Distance) | step | | barrel_cu_thickness_ pth | Required copper thickness in the barrel of PTH. | Barrel Cu Thickness PTH | Float (Distance) | step | | barrel_cu_thickness_ via | Required copper thickness in the barrel of Via holes. | Barrel Cu Thickness Via | Float (Distance) | step |
Table D-3. Metadata Content - Manufacturing (cont.)
| Name | Description | Display Name | Type | Entity Level | |---------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------|-------------------|----------------| | circuit_copper_repai rs_allowed | (yes, only after approval, no) Indicates whether copper repairs, in order to resolve spacing problems, are allowed on the board. | PCB Circuit Copper Repairs Allowed | Text With Options | step | | contour_processing_ type | (rout, V-score, laser cutting) Indicates how the board can be cut from the panel. | Contour Processing Type | Text With Options | step | | copper_area_percent | Percentage of copper. | Copper Area Percent | Float | step | | date_stamp_format | (WWYY, YYWW, YYMM, MMYY, LLMMYY, WWYY-LLL, YYWW-LLL, WW-YY-LLL, WWYYLL) Format of the date stamp. W=Week, Y = Year,M= Month, D = Day, L = Lot | Date Stamp Format | TextWith Options | step | | date_stamp_required | Indicates whether a date stamp should be added on the board. | Date Stamp Required | Boolean | step | | electrical_test_requir ed | Indicates whether Electrical testing of this board is required. | Electrical Test Required | Boolean | step | | fiducial_soldermask _clearance | Indicates the minimum soldermask clearance for fiducial pads. | Fiducial Soldermask Clearance | Float (Distance) | step | | gold_plating_define d_by | (Gold Mask, Soldermask, NA) Type of gold plating used. | Gold Plating Defined by | Option | step | | high_voltage_board | Indicates whether this board needs to be tested for high voltage. | High Voltage Board | Boolean | step | | hole_breakout_allow ed | Indicates whether a hole can break out of the copper pad. | Hole Breakout Allowed | Boolean | step |
Table D-3. Metadata Content - Manufacturing (cont.)
| Name | Description | Display Name | Type | Entity Level | |-------------------------------|-----------------------------------------------------------------------------------------------------------|-----------------------------------|------------------|----------------| | legend_clipping_allo wed | Indicates whether clipping of the legend to clear exposed copper from being covered by legend is allowed. | Legend Clipping Allowed | Boolean | step | | lot | Production lot number for a board. | Production Lot Number | Text | step | | mfg_id_stamp | Indicates whether a manufacturer identification stamp should be added on the board. | Manufacturer Identification Stamp | Boolean | step | | min_conductor_widt h_inner | Minimum conductor width on inner layers. | MinConductor Width Inner | Float (Size) | step | | min_conductor_widt h_outer | Minimum conductor width on outer layers. | MinConductor Width Outer | Float (Size) | step | | min_copper_spacing inner | Minimum copper spacing on inner layers. | Min Copper Spacing Inner | Float (Distance) | step | | min_copper_spacing outer | Minimum copper spacing on outer layers. | Min Copper Spacing Outer | Float (Distance) | step | | number_of_drill_hol es | Number of drill holes. | Number of Drill Holes | Integer | step | | number_of_thru_pad s | Number of thru pads. | Number of Thru Pads | Integer | step | | number_of_tooling holes | Number of tooling holes. | Number of Tooling Holes | Integer | step | | number_of_unique drill_sizes | Number of unique drill sizes. | Number of Unique Drill Sizes | Integer | step | | number_of_vias | Number of vias. | Number of Vias | Integer | step | | part_number_stamp | Indicates whether a Part number stamp should be added on the board. | Part Number Stamp | Boolean | step | | plug_vias | Indicates whether vias should be plugged. | Plug Vias | Boolean | step |
Table D-3. Metadata Content - Manufacturing (cont.)
| Name | Description | Display Name | Type | Entity Level | |---------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------|-------------------|----------------| | print_et_test_stamp_ on_board | Indicates whether it is required to print an ET stamp on the board. | Print ET Test Stamp on Board | Boolean | step | | smallest_drill_size | Smallest drill size. | Smallest Drill Size | Float (Size) | step | | smallest_trace_width | Smallest trace width. | Smallest Trace Width | Float (Size) | step | | smallest_via_diamet er | Smallest via diameter. | Smallest Via Diameter | Float (Size) | step | | surface_finish_conta ct_fingers | (HASL, Lead-Free HASL, OSP (Intek), ENIG, Deep Gold, Wirebondable Gold, Bare Cu, Immersion Silver, White Tim, Other) Surface finish for contact fingers. | Surface Finish Contact Fingers | Text With Options | step | | surface_finish_pads | (HASL, Lead-Free HASL, OSP (Intek), ENIG, Deep Gold, Wirebondable Gold, Bare Cu, Immersion Silver, White Tim, Other) Surface finish for exposed pads. | Surface Finish Pads | Text With Options | step | | teardrop_allowed_on _inner | Indicates whether it is allowed to add teardrops on inner copper layers. | Teardrop Addition Allowed on Inner | Boolean | step | | teardrop_allowed_on _outer | Indicates whether it is allowed to add teardrops on outer copper layers. | Teardrop Addition Allowed on Outer | Boolean | step | | thieving_restrictions _on_inner | Restrictions for thieving patterns on inner layers (free text). | Thieving Restrictions on Inner | Text | step | | thieving_restrictions _on_outer | Restrictions for thieving patterns on inner layers (free text). | Thieving Restrictions on Outer | Text | step |
Table D-3. Metadata Content - Manufacturing (cont.)
| Name | Description | Display Name | Type | Entity Level | |-------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------|-------------------|----------------| | ul_code_stamp | Indicates whether a UL Code stamp should be added on the board. | UL Code Stamp | Boolean | step | | unique_serial_nr_sta mp | Indicates whether a unique serial number stamp should be added on the board. | Unique Serial nr Stamp | Boolean | step | | via_tenting | Indicates whether there are tented vias. | Via Tenting | Boolean | step | | via_treatments | (Via Fill - Conductive, Via Fill - Non-conductive, Via Fill - Copper Plated, Via Fill - Soldermask Hole Filled, Via Capped, Clearance - Standard Soldermask Clearance, Dry Film Via Tenting, Soldermask Defined - Soldermask over Via) The via treatment that should be applied. | Via Treatments | Text With Options | step |
Assembly Metadata Section
These are the tags in the requirements section.
Table D-4. Metadata Content - Assembly
| Name | Description | Display Name | Data Type | Entity Level | |-------------------------|----------------------------------------------------------------------------------------------------------|------------------------|-------------|----------------| | cad_package_analys is | CAD package analysis: Number of unique cells per side and total with associated pin count and pin pitch. | CAD Package Analysis | Integer | step | | complete_test_requir ed | Indicates whether a test including barrel testing is required. | Complete Test Required | Boolean | step | | component_count | Component count on board or panel. | Components per Step | Integer | step |
Table D-4. Metadata Content - Assembly (cont.)
| Name | Description | Display Name | Data Type | Entity Level | |------------------------------|--------------------------------------------------------------------------------------|----------------------------|------------------|----------------| | number_of_accessib le_nets | Number of accessible nets. | Number of Accessible Nets | | step | | number_of_fiducials | Number of fiducials. | Number of Fiducials | Integer | step | | number_of_multi_pi n_nets | Number of multi-pin nets. | Number of Multi-pin Nets | Integer | step | | number_of_nets | Number of nets. | Number of Nets | Integer | step | | number_of_nets_wit h_probes | Number of nets with probes. | Number of Nets with Probes | Integer | step | | number_of_single_p in_nets | Number of single pin nets. | Number of Single Pin Nets | Integer | step | | number_of_test_poi nts | Number of test points (net ends) on the board or panel. | Number of Test Points | Integer | step | | number_of_un-conn ected_nets | Number of unconnected nets. | Number of Unconnected Nets | Integer | step | | pressfit_technology | Indicates whether pressfit technology should be used on this board. | Pressfit Technology | Boolean | step | | smallest_pin_pitch | Smallest pin pitch. | Smallest Pin Pitch | Float (Distance) | step | | smd_technology | (single sided, double sided, none) The sides in the design that have SMD technology. | SMD Technology | Option | step | | total_number_of_sm d_pads | Total number of SMD pads. | Total Number of SMD Pads | Integer | step |
Final Metadata Section
These are the tags in the final section.
Table D-5. Metadata Content - Final
| Name | Description | Display Name | Data Type | Entity Type | |---------------------------------|--------------------------------------------------------------|-------------------------------------|-------------|---------------| | qual_coupon_crosss ection_rpt | Type of quality coupon cross section report (free text). | Quality Coupon Cross Section Report | Boolean | step | | ship_as | (Single board, assembly panel) How the product is delivered. | Ship as | Option | step | | solder_resist_adhesi on_tst_rpt | Type of solder resist adhesion test report (free text). | Solder Resist Adhesion Test Report | Boolean | step | | solderability_test_re port | Type of solderability test report (free text). | Solderability Test Report | Boolean | step |
Metadata Example
This is an example of a metedata.xml file.
<metadata> <Header description="General Information" > <node display="Buried Resistor" value="no" name="buried_resistor" /> <node display="Buried Capacitor" value="no" name="buried_capacitor" /> <node display="Company Address" value="Smallville" name="company_address" /> <node display="Company Name" value="OurCo" name="company_name" /> <node display="Counter Bore" value="no" name="counter_bore" /> <node display="Counter Sink" value="yes" name="countersink" /> ... </Header> <Requirements description="Board Requirements" > <node display="Additional Requirements" value="" name="additional_requirements" /> <node display="Board Outline Tolerance Plus" units="MM" value="" name="board_outline_tolerance_plus" /> <node display="Board Outline Tolerance Minus" units="MM" value="" name="board_outline_tolerance_minus" /> <node display="Board Thickness" units="MM" value="1.71603" name="board_thickness" /> <node display="Board Thickness Tol Plus" units="MM" value="" name="board_thickness_tol_plus" /> <node display="Board Thickness Tol Minus" units="MM" value="" name="board_thickness_tol_minus" /> ... </Requirements> <Steps description="Steps" > <Step name="cad" > <Header description="General Information" > <node display="Direct Connections Present" value="" name="direct_connections_present" /> <node display="Part X Size" units="MM" value="235.6" name="part_x_size" /> <node display="Part Y Size" units="MM" value="447.68" name="part_y_size" / > <node display="Stacked Vias Present" value="" name="stacked_vias_present" /> </Header> <Requirements description="Board Requirements" > <node display="Additional Copper Layer Requirements" value="" name="additional_copper_lyr_require" /> <node display="Gold Plating Thickness Min" units="MM" value="" name="gold_plating_thickness_min" /> <node display="Gold Plating Thickness Max" units="MM" value=""
name="gold_plating_thickness_max" /> <node display="Hole Position Plus Tolerance" units="MM" value="" name="hole_position_plus_tolerance" /> <node display="Hole Position Minus Tolerance" units="MM" value="" name="hole_position_minus_tolerance" /> <node display="Idenitfy Soldermask Define Pads that Need to Remain Untouched" value="" name="identify_soldermask_define_pads_that_need_to_remain_untouched" /> ... </Requirements> <Manufacturing description="Manufacturing Process" > <node display="Allowed to Remove non-functional Pads" value="" name="allowed_remove_nfp" /> <node display="Barrel Cu Thickness Blind Via" units="MM" value="" name="barrel_cu_thickness_blind_via" /> <node display="Barrel Cu Thickness Buried Via" units="MM" value="" name="barrel_cu_thickness_buried_via" /> <node display="Barrel Cu Thickness Pressfit PTH" units="MM" value="" name="barrel_cu_thickness_pressfit_pth" /> <node display="Barrel Cu Thickness PTH" units="MM" value="" name="barrel_cu_thickness_pth" /> <node display="Barrel Cu Thickness Via" units="MM" value="" name="barrel_cu_thickness_via" /> ... </Manufacturing> <Assembly description="Assembly" > <node display="Cad Package Analysis" value="53" name="cad_package_analysis" > <classify_by display="CAD Packages on Top Layer" value="36" name="Top" > <classify_by display="CAD Package" value="13" name="EB020A0" > <classify_by display="Pin Count" value="20" name="pin_count" /> <classify_by display="Pitch" units="MM" value="1.27" name="pitch" /> </classify_by> <classify_by display="CAD Package" value="1" name="EG064A3" > <classify_by display="Pin Count" value="65" name="pin_count" /> <classify_by display="Pitch" units="MM" value="0.5" name="pitch" /> </classify_by> ... </classify_by> <classify_by display="CAD Packages on Bottom Layer" value="17" name="Bottom" > <classify_by display="CAD Package" value="2" name="EB048A0" > <classify_by display="Pin Count" value="50" name="pin_count" />
<classify_by display="Pitch" units="MM" value="0.5" name="pitch" /> </classify_by> <classify_by display="CAD Package" value="11" name="EUF03S0" > <classify_by display="Pin Count" value="3" name="pin_count" /> <classify_by display="Pitch" units="MM" value="1.8999975" name="pitch" /> </classify_by> ... </classify_by> </node> <node display="Complete Test Required" value="" name="complete_test_required" /> <node display="Components per Step" value="2436" name="component_count" > <classify_by display="Components in Top Layer" value="677" name="Top" /> <classify_by display="Components in Bottom Layer" value="1759" name="Bottom" /> </node> <node display="Number of Fiducials" value="16" name="number_of_fiducials" > <classify_by display="Fiducials in Top Layer" value="8" name="Top" /> <classify_by display="Fiducials in Bottom Layer" value="8" name="Bottom" /> </node> <node display="Number of Nets" value="1870" name="number_of_nets" /> <node display="Number of Accessible Nets" value="" name="number_of_accessible_nets" /> <node display="Number of Multi-pin Nets" value="2" name="number_of_multi_pin_nets" > <classify_by display="Nets with Multiple Test Points in Top Layer" value="0" name="Top" /> <classify_by display="Nets with Multiple Test Points in Bottom Layer" value="2" name="Bottom" /> </node> <node display="Number of nets with probes" value="" name="number_of_nets_with_probes" /> <node display="Number of single pin nets" value="929" name="number_of_single_pin_nets" > <classify_by display="Nets with a Single Test Point in Top Layer" value="0" name="Top" /> <classify_by display="Nets with a Single Test Point in Bottom Layer" value="929" name="Bottom" /> </node> <node display="Number of unconnected nets" value="939" name="number_of_un-connected_nets" > <classify_by display="Nets with No Test Points in Top Layer" value="937" name="Top" />
<classify_by display="Nets with No Test Points in Bottom Layer" value="2" name="Bottom" /> </node> <node display="Number of Test Points" value="933" name="number_of_test_points" > <classify_by display="Test Points in Top Layer" value="0" name="Top" /> <classify_by display="Test Points in Bottom Layer" value="933" name="Bottom" /> </node> <node display="Pressfit Technology" value="N/A" name="pressfit_technology" /> <node display="Smallest Pin Pitch" units="MM" value="N/A" name="smallest_pin_pitch" /> <node display="SMD Technology" value="None" name="smd_technology" /> <node display="Total Number of SMD Pads" value="0" name="total_number_of_smd_pads" > <classify_by display="SMD Pads in Top Layer" value="0" name="Top" /> <classify_by display="SMD Pads in Bottom Layer" value="0" name="Bottom" /> </node> </Assembly> <Final description="Final QC" > <node display="Quality Coupon Cross Section Report" value="" name="qual_coupon_crosssection_rpt" /> <node display="Ship as" value="Single board" name="ship_as" /> <node display="Solder Resist Adhesion Test Report" value="" name="solder_resist_adhesion_tst_rpt" /> <node display="Solderability Test Report" value="" name="solderability_test_report" /> </Final> </Step> </Steps> </metadata>
Metadata Schema
This is the metadata schema.
<?xml version="1.0" encoding="utf-8" ?> <metadataSchema description=""> <metadataSection internalName="Header" description="General Information"> <metadataAttr internalName="buried_resistor" displayName="Buried Resistor" entityLevel="JOB" type="Boolean" callback="ODBAttr" description="Defines whether board contains buried resistors"/> <metadataAttr internalName="buried_capacitor" displayName="Buried Capacitor" entityLevel="JOB" type="Boolean" callback="ODBAttr" description="Defines whether board contains buried capacitors"/> <metadataAttr internalName="company_address" displayName="Company Address" entityLevel="JOB" type="Text" callback="ODBAttr" description="Defines company address"/> <metadataAttr internalName="company_name" displayName="Company Name" entityLevel="JOB" type="Text" callback="ODBAttr" description="Defines designer company name"/> <metadataAttr internalName="counter_bore" displayName="Counter Bore" entityLevel="JOB" type="Boolean" callback="ODBAttr" description="Defines whether job requires counter bore"/> <metadataAttr internalName="countersink" displayName="Counter Sink" entityLevel="JOB" type="Boolean" callback="ODBAttr" description="Defines whether job requires counter sink drilling"/> <metadataAttr internalName="customer_control_number" displayName="Customer Control Number" entityLevel="JOB" type="Text" callback="ODBAttr" description="Defines revision control number if avaliable"/> <metadataAttr internalName="designer_email" displayName="Designer Email" entityLevel="JOB" type="Text" callback="ODBAttr" description="Defines designer email address"/> <metadataAttr internalName="designer_name" displayName="Designer Name" entityLevel="JOB" type="Text" callback="ODBAttr" description="Defines designer name"/> <metadataAttr internalName="designer_phone_number" displayName="Designer Phone Number" entityLevel="JOB" type="Text" callback="ODBAttr" description="Defines designer phone number"/> <metadataAttr internalName="direct_connections_present" displayName="Direct Connections Present" entityLevel="STEP" type="Boolean" callback="ODBAttr" description="Indicates that direct connections to planes are known to exist."/> <metadataAttr internalName="edge_connectors" displayName="Edge Connectors" entityLevel="JOB" type="Boolean" callback="ODBAttr" description="Defines whether board contains edge connectors"/> <metadataAttr internalName="layer_count" displayName="Layer Count" entityLevel="JOB" type="Integer" callback="Function" description="Defines number of copper layers in board"/> <metadataAttr internalName="layout_name" displayName="Layout Name" entityLevel="JOB" type="Text" callback="ODBAttr" description="Defines layout name of design"/> <metadataAttr internalName="part_x_size" displayName="Part X Size" entityLevel="STEP" type="float" unitsType="Distance" unitsSize="INCH_MM" callback="Function" description="Defines part X dimension"/> <metadataAttr internalName="part_y_size" displayName="Part Y Size" entityLevel="STEP" type="float" unitsType="Distance" unitsSize="INCH_MM" callback="Function" description="Defines part Y dimension"/> <metadataAttr internalName="pcb_part_number" displayName="PCB Part Number" entityLevel="JOB" type="Text" callback="ODBAttr"
description="Defines part number of job"/> <metadataAttr internalName="revision" displayName="Revision" entityLevel="JOB" type="Text" callback="ODBAttr" description="Defines part revision"/> <metadataAttr internalName="rohs_compliant" displayName="RoHS Compliant" entityLevel="JOB" type="Boolean" callback="ODBAttr" description="Defines whether board needs RoHS compliance"/> <metadataAttr internalName="ruling_ipc_spec" displayName="Ruling IPC Spec (Class 1, 2, 3 etc.)" entityLevel="JOB" type="Option" callback="ODBAttr" description="IPC Classification" options="Class 1, Class 2, Class 3, ?"/> <metadataAttr internalName="stacked_vias_present" displayName="Stacked Vias Present" entityLevel="STEP" type="Boolean" callback="ODBAttr" description="Indicates if stacked vias are present"/> </metadataSection> <metadataSection internalName="Requirements" description="Board Requirements"> <metadataAttr internalName="additional_requirements" displayName="Additional Requirements" entityLevel="JOB" type="Text" callback="ODBAttr" description="Free text - up to 20000 characters"/> <metadataAttr internalName="additional_copper_lyr_require" displayName="Additional Copper Layer Requirements" entityLevel="STEP" type="Text" callback="ODBAttr" description="Other Requirements"/> <metadataAttr internalName="board_outline_tolerance_plus" displayName="Board Outline Tolerance Plus" entityLevel="JOB" type="float" unitsType="Distance" unitsSize="MIL_MICRON" callback="ODBAttr" description="Defines +tolerance of board size"/> <metadataAttr internalName="board_outline_tolerance_minus" displayName="Board Outline Tolerance Minus" entityLevel="JOB" type="float" unitsType="Distance" unitsSize="MIL_MICRON" callback="ODBAttr" description="Defines -tolerance of board size"/> <metadataAttr internalName="board_thickness" displayName="Board Thickness" entityLevel="JOB" type="float" unitsType="Distance" unitsSize="MIL_MICRON" callback="Function" description="Defines board thickness"/> <metadataAttr internalName="board_thickness_tol_plus" displayName="Board Thickness Tol Plus" entityLevel="JOB" type="float" unitsType="Distance" unitsSize="MIL_MICRON" callback="ODBAttr" description="Defines +tolerance of board thickness"/> <metadataAttr internalName="board_thickness_tol_minus" displayName="Board Thickness Tol Minus" entityLevel="JOB" type="float" unitsType="Distance" unitsSize="MIL_MICRON" callback="ODBAttr" description="Defines -tolerance of board thickness"/> <metadataAttr internalName="board_thickness_type" displayName="Board Thickness Type" entityLevel="JOB" type="TextWithOptions" callback="ODBAttr" description="Defines how board thickness is measured/ specified" options="over foil, over laminate, over plated copper, over mask on plated copper"/> <metadataAttr internalName="bottom_legend_color" displayName="Bottom Legend Color" entityLevel="JOB" type="TextWithOptions" callback="ODBAttr" description="Defines color of bottom legend" options="none , green , white , yellow , black , blue , red"/> <metadataAttr internalName="bottom_soldermask_color" displayName="Bottom Soldermask Color" entityLevel="JOB" type="TextWithOptions" callback="ODBAttr" description="Defines color of bottom soldermask" options="none , green , white , yellow , black , blue ,
red"/> <metadataAttr internalName="flammability_rating_standard" displayName="Flammability Rating Standard" entityLevel="JOB" type="Text" callback="ODBAttr" description="Defines Flammability Rating Standard (free text)"/> <metadataAttr internalName="general_pcb_standard" displayName="General PCB Standard" entityLevel="JOB" type="Text" callback="ODBAttr" description="Defines general PCB Standard (free text)"/> <metadataAttr internalName="glass_transition_temperature_tg" displayName="Glass Transition Temperature (Tg)" entityLevel="JOB" type="Float" unitsType="Temperature" callback="ODBAttr" description="Degree Fahrenheit/Celcius"/> <metadataAttr internalName="gold_plating_thickness_min" displayName="Gold Plating Thickness Min" entityLevel="STEP" type="float" unitsType="Distance" unitsSize="MIL_MICRON" callback="ODBAttr" description="Defines minimum gold plating thickness"/> <metadataAttr internalName="gold_plating_thickness_max" displayName="Gold Plating Thickness Max" entityLevel="STEP" type="float" unitsType="Distance" unitsSize="MIL_MICRON" callback="ODBAttr" description="Defines maximum gold plating thickness"/> <metadataAttr internalName="hole_position_plus_tolerance" displayName="Hole Position Plus Tolerance" entityLevel="STEP" type="float" unitsType="Distance" unitsSize="MIL_MICRON" callback="ODBAttr" description="Defines +tolerance for hole positions"/> <metadataAttr internalName="hole_position_minus_tolerance" displayName="Hole Position Minus Tolerance" entityLevel="STEP" type="float" unitsType="Distance" unitsSize="MIL_MICRON" callback="ODBAttr" description="Defines -tolerance for hole positions"/> <metadataAttr internalName="identify_soldermask_define_pads_that_need_to_remain_untouch ed" displayName="Idenitfy Soldermask Define Pads that Need to Remain Untouched" entityLevel="STEP" type="Boolean" callback="ODBAttr" description="Attribute indicates soldermask pads that are to remain untouched"/> <metadataAttr internalName="legend_clearance_from_component_pads" displayName="Legend Clearance from Component Pads" entityLevel="STEP" type="float" unitsType="Distance" unitsSize="MIL_MICRON" callback="Function" description="Defines minimum spacing between legend and edge of copper component pads"/> <metadataAttr internalName="legend_clearance_from_soldermask_clearance" displayName="Legend Clearance from Soldermask Clearance" entityLevel="STEP" type="float" unitsType="Distance" unitsSize="MIL_MICRON" callback="ResultAttr" description="Defines minimum spacing between legend and edge of soldermask clearances" arguments="min, sm"/> <metadataAttr internalName="legend_clearance_from_test_points" displayName="Legend Clearance from Test Points" entityLevel="STEP" type="float" unitsType="Distance" unitsSize="MIL_MICRON" callback="Function" description="Defines minimum spacing between legend and edge of copper test pads"/> <metadataAttr internalName="legend_sides" displayName="Legend Sides" entityLevel="JOB" type="Option" callback="ODBAttr" description="Defines sides on which legend printing is to be applied" options="none,Top,Bottom,Both"/> <metadataAttr internalName="lyr_to_lyr_reg_max_tolerance" displayName="Layer to Layer Registration Max Tolerance" entityLevel="STEP" type="float" unitsType="Distance" unitsSize="MIL_MICRON"
callback="ODBAttr" description="Defines maximum tolerance for layer to layer registration of copper layers"/> <metadataAttr internalName="max_bow_and_twist_of_the_pcb" displayName="Max Bow and Twist of the PCB" entityLevel="STEP" type="float" unitsType="Distance" unitsSize="MIL_MICRON" callback="ODBAttr" description="Defines maximim bow&twist requirement for this part"/> <metadataAttr internalName="max_operating_temperature" displayName="Max Operating Temperature" entityLevel="JOB" type="Float" unitsType="Temperature" callback="ODBAttr" description="Degree Fahrenheit/Celcius"/> <metadataAttr internalName="min_ar_blind_via" displayName="Min AR Blind Via" entityLevel="STEP" type="float" unitsType="Distance" unitsSize="MIL_MICRON" callback="ResultAttr" description="Defines the AR requirement for blind via holes" arguments="min, blind_via_ar"/> <metadataAttr internalName="min_ar_buried_via" displayName="Min AR Buried Via" entityLevel="STEP" type="float" unitsType="Distance" unitsSize="MIL_MICRON" callback="ResultAttr" description="Defines min AR requirement for buried via holes" arguments="min, buried_via_ar"/> <metadataAttr internalName="min_ar_pressfit_pth" displayName="Min AR Pressfit PTH" entityLevel="STEP" type="float" unitsType="Distance" unitsSize="MIL_MICRON" callback="Function" description="Defines min AR requirement for Pressfit PTH"/> <metadataAttr internalName="min_ar_pth" displayName="Min AR PTH" entityLevel="STEP" type="float" unitsType="Distance" unitsSize="MIL_MICRON" callback="ResultAttr" description="Defines min AR requirement for PTH" arguments="min, pth_ar"/> <metadataAttr internalName="min_ar_via" displayName="Min AR Via" entityLevel="STEP" type="float" unitsType="Distance" unitsSize="MIL_MICRON" callback="ResultAttr" description="Defines min AR requirement for via holes" arguments="min, via_ar"/> <metadataAttr internalName="min_copper_to_board_edge" displayName="Min Copper to Board Edge" entityLevel="STEP" type="float" unitsType="Distance" unitsSize="MIL_MICRON" callback="ResultAttr" description="Defines minimum spacing between copper and board edge" arguments="min, r2c"/> <metadataAttr internalName="min_hole_to_edge" displayName="Min Hole to Edge" entityLevel="STEP" type="float" unitsType="Distance" unitsSize="MIL_MICRON" callback="Function" description="Defines minimum hole to board edge spacing"/> <metadataAttr internalName="min_hole_to_hole" displayName="Min Hole to Hole" entityLevel="STEP" type="float" unitsType="Distance" unitsSize="MIL_MICRON" callback="ResultAttr" description="Defines minimum hole to hole spacing" arguments="min, closeh"/> <metadataAttr internalName="min_soldermask_clearance_for_bga_pads" displayName="Min Soldermask Clearance for BGA Pads" entityLevel="STEP" type="float" unitsType="Distance" unitsSize="MIL_MICRON" callback="Function" description="Defines minimum soldermask clearance for BGA pads"/> <metadataAttr internalName="min_soldermask_clearance_for_npth" displayName="Min Soldermask Clearance for NPTH" entityLevel="STEP" type="float" unitsType="Distance" unitsSize="MIL_MICRON" callback="ResultAttr" description="Defines minimum soldermask clearance for NPTH drills" arguments="min, ar_npth"/> <metadataAttr internalName="min_soldermask_clearance_for_pth_pads" displayName="Min Soldermask Clearance for PTH Pads" entityLevel="STEP" type="float" unitsType="Distance" unitsSize="MIL_MICRON" callback="ResultAttr" description="Defines minimum soldermask clearance for plated TH pads" arguments="min, ar_pth"/> <metadataAttr internalName="min_soldermask_clearance_for_smd_pads"
displayName="Min Soldermask Clearance for SMD Pads" entityLevel="STEP" type="float" unitsType="Distance" unitsSize="MIL_MICRON" callback="ResultAttr" description="Defines minimum soldermask clearance for SMD pads" arguments="min, ar_smd"/> <metadataAttr internalName="pcb_acceptability_standard" displayName="PCB Acceptability Standard" entityLevel="JOB" type="Text" callback="ODBAttr" description="Defines PCB Acceptability Standard (free text)"/> <metadataAttr internalName="peelable_mask_side" displayName="Peelable Mask Side" entityLevel="JOB" type="Option" callback="ODBAttr" description="Defines whether peelable mask is to be applied, and if yes, on which sides" options="none,Top,Bottom,Both"/> <metadataAttr internalName="plated_edge" displayName="Plated Edge" entityLevel="JOB" type="Boolean" callback="ODBAttr" description="Defines whether plating on the board edge is required"/> <metadataAttr internalName="plated_slots" displayName="Plated Slots" entityLevel="JOB" type="Boolean" callback="ODBAttr" description="Defines whether job contains plated slots"/> <metadataAttr internalName="qualification_performance_std" displayName="Qualification and Performance Standard" entityLevel="JOB" type="Text" callback="ODBAttr" description="Defines Qualification and Performance Standard (free text)"/> <metadataAttr internalName="soldermask_sides" displayName="Soldermask Sides" entityLevel="JOB" type="Option" callback="ODBAttr" description="Defines sides on which sides soldermask is to be applied" options="None,Top,Bottom,Both"/> <metadataAttr internalName="thermal_stress_requirement" displayName="Thermal Stress Requirement" entityLevel="JOB" type="Text" callback="ODBAttr" description="Defines thermal stress requirements for board (free text)"/> <metadataAttr internalName="tolerance_standard" displayName="Tolerance Standard" entityLevel="JOB" type="Text" callback="ODBAttr" description="Defines standard for tolerances in board (free text)"/> <metadataAttr internalName="top_legend_color" displayName="Top Legend Color" entityLevel="JOB" type="TextWithOptions" callback="ODBAttr" description="Defines color of top legend" options="none , green , white , yellow , black , blue , red"/> <metadataAttr internalName="top_soldermask_color" displayName="Top Soldermask Color" entityLevel="JOB" type="TextWithOptions" callback="ODBAttr" description="Defines color of top soldermask" options="none , green , white , yellow , black , blue , red"/> </metadataSection> <metadataSection internalName="Manufacturing" description="Manufacturing Process"> <metadataAttr internalName="allowed_remove_nfp" displayName="Allowed to Remove non-functional Pads" entityLevel="STEP" type="Boolean" callback="ODBAttr" description="Defines whether removing non-functional pads is allowed"/> <metadataAttr internalName="barrel_cu_thickness_blind_via" displayName="Barrel Cu Thickness Blind Via" entityLevel="STEP" type="float" unitsType="Distance" unitsSize="MIL_MICRON" callback="ODBAttr" description="Defines required Cu thickness in barrel of blind via holes"/> <metadataAttr internalName="barrel_cu_thickness_buried_via" displayName="Barrel Cu Thickness Buried Via" entityLevel="STEP" type="float" unitsType="Distance" unitsSize="MIL_MICRON"
callback="ODBAttr" description="Defines required Cu thickness in barrel of buried via holes"/> <metadataAttr internalName="barrel_cu_thickness_pressfit_pth" displayName="Barrel Cu Thickness Pressfit PTH" entityLevel="STEP" type="float" unitsType="Distance" unitsSize="MIL_MICRON" callback="ODBAttr" description="Defines required Cu thickness in barrel of Pressfit holes"/> <metadataAttr internalName="barrel_cu_thickness_pth" displayName="Barrel Cu Thickness PTH" entityLevel="STEP" type="float" unitsType="Distance" unitsSize="MIL_MICRON" callback="ODBAttr" description="Defines required Cu thickness in barrel of PTH"/> <metadataAttr internalName="barrel_cu_thickness_via" displayName="Barrel Cu Thickness Via" entityLevel="STEP" type="float" unitsType="Distance" unitsSize="MIL_MICRON" callback="ODBAttr" description="Defines required Cu thickness in barrel of via holes"/> <metadataAttr internalName="circuit_copper_repairs_allowed" displayName="PCB Circuit Copper Repairs Allowed" entityLevel="STEP" type="TextWithOptions" callback="ODBAttr" description="Defines whether copper repairs, to resolve spacing problems, are allowed on board" options="Yes , Only after approval , No"/> <metadataAttr internalName="contour_processing_type" displayName="Contour Processing Type" entityLevel="STEP" type="TextWithOptions" callback="ODBAttr" description="Defines how to cut board from panel" options="Route , V-score , Laser cutting"/> <metadataAttr internalName="copper_area_percent" displayName="Copper Area Percent" entityLevel="STEP" type="float" callback="ODBAttr" description="Percentage of copper"/> <metadataAttr internalName="date_stamp_format" displayName="Date Stamp Format" entityLevel="STEP" type="text" callback="ODBAttr" description="Defines format of date stamp"/> <metadataAttr internalName="date_stamp_required" displayName="Date Stamp Required" entityLevel="STEP" type="Boolean" callback="ODBAttr" description="Defines whether date stamp should be added on board"/> <metadataAttr internalName="electrical_test_required" displayName="Electrical Test Required" entityLevel="STEP" type="Boolean" callback="ODBAttr" description="Defines whether electrical testing of board is required"/> <metadataAttr internalName="fiducial_soldermask_clearance" displayName="Fiducial Soldermask Clearance" entityLevel="STEP" type="float" unitsType="Distance" unitsSize="MIL_MICRON" callback="Function" description="Defines the minimum soldermask clearance for fiducial pads"/> <metadataAttr internalName="gold_plating_defined_by" displayName="Gold Plating Defined by" entityLevel="STEP" type="Option" callback="ODBAttr" description="Gold mask/Soldermask/NA" options="Gold mask, Solder mask, N/ A"/> <metadataAttr internalName="high_voltage_board" displayName="High Voltage Board" entityLevel="STEP" type="Boolean" callback="ODBAttr" description="Defines whether board needs to be tested for high voltage"/> <metadataAttr internalName="hole_breakout_allowed" displayName="Hole Breakout Allowed" entityLevel="STEP" type="Boolean" callback="ODBAttr" description="Defines whether hole can break out of copper pad"/> <metadataAttr internalName="legend_clipping_allowed" displayName="Legend Clipping Allowed" entityLevel="STEP" type="Boolean" callback="ODBAttr" description="Defines whether clipping of legend to clear exposed copper from being covered by legend is allowed"/> <metadataAttr internalName="lot" displayName="Production Lot Number" entityLevel="STEP" type="text" callback="ODBAttr" description="Defines
the production lot number for a board"/> <metadataAttr internalName="mfg_id_stamp" displayName="Manufacturer Identification Stamp" entityLevel="STEP" type="Boolean" callback="ODBAttr" description="Defines whether a manufacturer identification stamp should be added on the board"/> <metadataAttr internalName="min_conductor_width_inner" displayName="Min Conductor Width Inner" entityLevel="STEP" type="float" unitsType="Distance" unitsSize="MIL_MICRON" callback="Function" description="Defines minimum conductor width on inner layers"/> <metadataAttr internalName="min_conductor_width_outer" displayName="Min Conductor Width Outer" entityLevel="STEP" type="float" unitsType="Distance" unitsSize="MIL_MICRON" callback="Function" description="Defines minimum conductor width on outer layers"/> <metadataAttr internalName="min_copper_spacing_inner" displayName="Min Copper Spacing Inner" entityLevel="STEP" type="float" unitsType="Distance" unitsSize="MIL_MICRON" callback="Function" description="Defines minimum copper spacing on inner layers"/> <metadataAttr internalName="min_copper_spacing_outer" displayName="Min Copper Spacing Outer" entityLevel="STEP" type="float" unitsType="Distance" unitsSize="MIL_MICRON" callback="Function" description="Defines minimum copper spacing on outer layers"/> <metadataAttr internalName="number_of_drill_holes" displayName="Number of Drill Holes" entityLevel="STEP" type="Integer" callback="Function" description="Number of drill holes"/> <metadataAttr internalName="number_of_thru_pads" displayName="Number of Thru Pads" entityLevel="STEP" type="Integer" callback="ResultAttr" description="Number of through pads" arguments="num, pth"/> <metadataAttr internalName="number_of_tooling_holes" displayName="Number of Tooling Holes" entityLevel="STEP" type="Integer" callback="ResultAttr" description="Number of tooling holes" arguments="num, tooling_holes"/> <metadataAttr internalName="number_of_unique_drill_sizes" displayName="Number of Unique Drill Sizes" entityLevel="STEP" type="Integer" callback="ResultAttr" description="Number of unique drill sizes" arguments="num, unique_drill_size"/> <metadataAttr internalName="number_of_vias" displayName="Number of Vias" entityLevel="STEP" type="Integer" callback="ResultAttr" description="Number of vias" arguments="num, via"/> <metadataAttr internalName="part_number_stamp" displayName="Part Number Stamp" entityLevel="STEP" type="Boolean" callback="ODBAttr" description="Defines whether part number stamp should be added on board"/> <metadataAttr internalName="plug_vias" displayName="Plug Vias" entityLevel="STEP" type="Boolean" callback="ODBAttr" description="Defines whether vias should be plugged"/> <metadataAttr internalName="print_et_test_stamp_on_board" displayName="Print ET Test Stamp on Board" entityLevel="STEP" type="Boolean" callback="ODBAttr" description="Defines whether required to print ET stamp on the board"/> <metadataAttr internalName="smallest_drill_size" displayName="Smallest Drill Size" entityLevel="STEP" type="Float" unitsType="Distance" unitsSize="MIL_MICRON" callback="Function" description="Smallest drill size"/> <metadataAttr internalName="smallest_trace_width" displayName="Smallest Trace Width" entityLevel="STEP" type="Float" unitsType="Distance" unitsSize="MIL_MICRON" callback="Function" description="Smallest trace width"/> <metadataAttr internalName="smallest_via_diameter" displayName="Smallest Via Diameter" entityLevel="STEP" type="Float"
unitsType="Distance" unitsSize="MIL_MICRON" callback="Function" description="Smallest via diameter"/> <metadataAttr internalName="surface_finish_contact_fingers" displayName="Surface Finish Contact Fingers" entityLevel="STEP" type="TextWithOptions" callback="ODBAttr" description="Defines surface finish for contact fingers" options="HASL , Lead-Free HASL , OSP (Entek) , ENIG , Deep Gold , Wirebondable Gold , Bare Cu , Immersion Silver , White Tin , Other"/> <metadataAttr internalName="surface_finish_pads" displayName="Surface Finish Pads" entityLevel="STEP" type="TextWithOptions" callback="ODBAttr" description="Defines surface finish for exposed pads" options="HASL , Lead-Free HASL , OSP (Entek) , ENIG , Deep Gold , Wirebondable Gold , Bare Cu , Immersion Silver , White Tin , Other"/> <metadataAttr internalName="teardrop_allowed_on_inner" displayName="Teardrop Addition Allowed on Inner" entityLevel="STEP" type="Boolean" callback="ODBAttr" description="Defines whether adding teardrops on inner copper layers is allowed"/> <metadataAttr internalName="teardrop_allowed_on_outer" displayName="Teardrop Addition Allowed on Outer" entityLevel="STEP" type="Boolean" callback="ODBAttr" description="Defines whether adding teardrops on outer copper layers is allowed"/> <metadataAttr internalName="thieving_restrictions_on_inner" displayName="Thieving Restrictions on Inner" entityLevel="STEP" type="Text" callback="ODBAttr" description="Defines restrictions for thieving patterns on inner layers (free text)"/> <metadataAttr internalName="thieving_restrictions_on_outer" displayName="Thieving Restrictions on Outer" entityLevel="STEP" type="Text" callback="ODBAttr" description="Defines restrictions for thieving patterns on outer layers (free text)"/> <metadataAttr internalName="ul_code_stamp" displayName="UL Code Stamp" entityLevel="STEP" type="Boolean" callback="ODBAttr" description="Defines whether UL Code stamp should be added on board"/> <metadataAttr internalName="unique_serial_nr_stamp" displayName="Unique Serial NR Stamp" entityLevel="STEP" type="Boolean" callback="ODBAttr" description="Defines whether a unique serial nr stamp should be added on board"/> <metadataAttr internalName="via_tenting" displayName="Via Tenting" entityLevel="STEP" type="Boolean" callback="ODBAttr" description="Defines whether via tenting can be used"/> <metadataAttr internalName="via_treatments" displayName="Via Treatments" entityLevel="STEP" type="TextWithOptions" callback="ODBAttr" description="Determine which via treatment should be applied" options="Via Fill - Conductive, Via Fill - Non-conductive, Via Fill - Copper Plated, Via Fill - Soldermask Hole Filled, Via Capped, Clearance - Standard Soldermask Clearance, Dry Film Via Tenting, Soldermask Defined Soldermask over Via"/> </metadataSection> <metadataSection internalName="Assembly" description="Assembly"> <metadataAttr internalName="cad_package_analysis" displayName="Cad Package Analysis" entityLevel="STEP" type="Integer" callback="Collective" description="CAD package analysis: Number of unique cells per side and total associated pin count and pin pitch"/> <metadataAttr internalName="complete_test_required" displayName="Complete Test Required" entityLevel="STEP" type="Boolean" callback="ODBAttr" description="Defines whether a test including barrel testing is required"/>
<metadataAttr internalName="component_count" displayName="Components per Step" entityLevel="STEP" type="Integer" callback="Collective" description="Total component count
Classified by layer (top, bottom, etc),
Then classified by technology (SMD, Thru, etc)"/> <metadataAttr internalName="number_of_fiducials" displayName="Number of Fiducials" entityLevel="STEP" type="Integer" callback="Collective" description="Number of top and bottom fiducials"/> <metadataAttr internalName="number_of_nets" displayName="Number of Nets" entityLevel="STEP" type="Integer" callback="Function" description="Number of nets"/> <metadataAttr internalName="number_of_accessible_nets" displayName="Number of Accessible Nets" entityLevel="STEP" type="Integer" callback="ODBAttr" description="Number of accessible nets"/> <metadataAttr internalName="number_of_multi_pin_nets" displayName="Number of Multi-pin Nets" entityLevel="STEP" type="Integer" callback="Collective" description="Number of multi-pin nets"/> <metadataAttr internalName="number_of_nets_with_probes" displayName="Number of nets with probes" entityLevel="STEP" type="Integer" callback="ODBAttr" description="Number of nets with probes"/> <metadataAttr internalName="number_of_single_pin_nets" displayName="Number of single pin nets" entityLevel="STEP" type="Integer" callback="Collective" description="Number of single pin nets"/> <metadataAttr internalName="number_of_un-connected_nets" displayName="Number of unconnected nets" entityLevel="STEP" type="Integer" callback="Collective" description="Number of unconnected nets"/> <metadataAttr internalName="number_of_test_points" displayName="Number of Test Points" entityLevel="STEP" type="Integer" callback="Collective" description="Defines the number of test points (net ends) on top and bottom sides"/> <metadataAttr internalName="pressfit_technology" displayName="Pressfit Technology" entityLevel="STEP" type="Boolean" callback="Function" description="Defines whether Pressfit technology should be used on this board."/> <metadataAttr internalName="smallest_pin_pitch" displayName="Smallest Pin Pitch" entityLevel="STEP" type="Float" unitsType="Distance" unitsSize="MIL_MICRON" callback="ResultAttr" description="Smallest pin pitch" arguments="min, c_pitch"/> <metadataAttr internalName="smd_technology" displayName="SMD Technology" entityLevel="STEP" type="Option" callback="Function" description="Defines number of sides that have SMD technology." options="Single sided, Double sided, None"/> <metadataAttr internalName="total_number_of_smd_pads" displayName="Total Number of SMD Pads" entityLevel="STEP" type="Integer" callback="Collective" description="Total number of SMD pads, classified by side"/> </metadataSection> <metadataSection internalName="Final" description="Final QC"> <metadataAttr internalName="qual_coupon_crosssection_rpt" displayName="Quality Coupon Cross Section Report" entityLevel="STEP" type="Text" callback="ODBAttr" description="Defines type of quality coupon cross section report (free text)"/> <metadataAttr internalName="ship_as" displayName="Ship as" entityLevel="STEP" type="Option" callback="ODBAttr" description="Single board / assembly panel" options="Single board, Assembly panel"/> <metadataAttr internalName="solder_resist_adhesion_tst_rpt" displayName="Solder Resist Adhesion Test Report" entityLevel="STEP"
type="Text" callback="ODBAttr" description="Defines type of solder resist adhesion test report (free text)"/> <metadataAttr internalName="solderability_test_report" displayName="Solderability Test Report" entityLevel="STEP" type="Text" callback="ODBAttr" description="Defines type of solderability test report (free text)"/> </metadataSection> </metadataSchema>
Appendix E Stackup Schema
This appendix describes the elements, their related sub-elements, and the relevant attributes of the stackup file. Each element's description contains the following sections: parent element, hierarchical diagram, minimum and maximum numbers of occurrences, description of the attributes, and a list of sub-elements known as children. The full schema file is provided.
Elements or attributes enclosed in solid lines are mandatory. Those enclosed in dotted lines are optional. Plus or minus indicate the collapsed or expanded state of the element or attribute. The display of a numerical range under an element or attribute indicates its accepted range of values. Some elements are designated as simpleType-they specify constraints and information about the values of attributes or text-only elements. Other elements are complexType-an XML element that contains other elements or attributes.
| StackupFile. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 331 | |-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------| | StackupFile/EdaData. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 332 | | StackupFile/EdaData/Specs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 334 | | StackupFile/EdaData/Specs/Spec. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 335 | | StackupFile/EdaData/Specs/Spec/Material. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 336 | | StackupFile/EdaData/Specs/Spec/Material/Dielectric . . . . . . . . . . . . . . . . . . . . . . . . . | 337 | | StackupFile/EdaData/Specs/Spec/Material/Dielectric/Properties. . . . . . . . . . . . . . . . | 339 | | StackupFile/EdaData/Specs/Spec/Material/Dielectric/Properties/Property . . . . . . . | 340 | | StackupFile/EdaData/Specs/Spec/Material/Conductor . . . . . . . . . . . . . . . . . . . . . . . . | 342 | | StackupFile/EdaData/Specs/Spec/Material/Conductor/Properties. . . . . . . . . . . . . . . | 344 | | StackupFile/EdaData/Specs/Spec/Material/Conductor/Properties/Property . . . . . . | 345 | | StackupFile/EdaData/Specs/Spec/Material/Default_Thickness . . . . . . . . . . . . . . . . . | 347 | | StackupFile/EdaData/Specs/Spec/Impedance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 348 | | StackupFile/EdaData/Specs/Spec/Impedance/Single_Ended . . . . . . . . . . . . . . . . . . . | 351 | | StackupFile/EdaData/Specs/Spec/Impedance/Single_Ended/TraceWidth . . . . . . . . | 353 | | StackupFile/EdaData/Specs/Spec/Impedance/Single_Ended/RefPlane . . . . . . . . . . . | 355 | | StackupFile/EdaData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide. . | 356 | | StackupFile/EdaData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide/ TraceWidth. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 358 | | StackupFile/EdaData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide/Spacing 360 | StackupFile/EdaData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide/Spacing 360 | | StackupFile/EdaData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide/ | StackupFile/EdaData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide/ |
| CoplanarSpacing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 361 | |--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------| | StackupFile/EdaData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide/ CoplanarTraceWidth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 362 | | StackupFile/EdaData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide/ RefPlane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 364 | | StackupFile/EdaData/Specs/Spec/Impedance/Differential_Edge_Coupled. . . . . . . . . . | 365 | | StackupFile/EdaData/Specs/Spec/Impedance/Differential_Edge_Coupled/TraceWidth367 | | | StackupFile/EdaData/Specs/Spec/Impedance/Differential_Edge_Coupled/Spacing . . | 369 | | StackupFile/EdaData/Specs/Spec/Impedance/Differential_Edge_Coupled/RefPlane . | 370 | | StackupFile/EdaData/Specs/Spec/Impedance/Single_Ended_Coplanar_Waveguide. . | 371 | | StackupFile/EdaData/Specs/Spec/Impedance/Single_Ended_Coplanar_Waveguide/ TraceWidth. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 373 | | StackupFile/EdaData/Specs/Spec/Impedance/Single_Ended_Coplanar_Waveguide/ CoplanarSpacing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 375 | | StackupFile/EdaData/Specs/Spec/Impedance/Single_Ended_Coplanar_Waveguide/ CoplanarTraceWidth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 376 | | StackupFile/EdaData/Specs/Spec/Impedance/Single_Ended_Coplanar_Waveguide/ RefPlane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 378 | | StackupFile/EdaData/Specs/Spec/Impedance/Differential_Broadside_Coupled . . . . . | 379 | | StackupFile/EdaData/Specs/Spec/Impedance/Differential_Broadside_Coupled/ TraceWidth. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 381 | | StackupFile/EdaData/Specs/Spec/Impedance/Differential_Broadside_Coupled/ TraceSeparation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 383 | | StackupFile/EdaData/Specs/Spec/Impedance/Differential_Broadside_Coupled/RefPlane 384 StackupFile/EdaData/Stackup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 385 | | StackupFile/EdaData/Stackup/Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 387 | | StackupFile/EdaData/Stackup/Group/Layer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 389 | | StackupFile/EdaData/Stackup/Group/Layer/SpecRef. . . . . . . . . . . . . . . . . . . . . . . . . . . | 391 | | StackupFile/EdaData/Stackup/Group/Layer/SpecRef/Material. . . . . . . . . . . . . . . . . . . | 392 | | StackupFile/EdaData/Stackup/Group/Layer/SpecRef/Impedance. . . . . . . . . . . . . . . . . | 394 | | StackupFile/SupplierData. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 395 | | StackupFile/SupplierData/Specs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 397 | | StackupFile/SupplierData/Specs/Spec . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 398 | | StackupFile/SupplierData/Specs/Spec/Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 399 | | StackupFile/SupplierData/Specs/Spec/Material/Dielectric . . . . . . . . . . . . . . . . . . . . . . . | 400 |
| StackupFile/SupplierData/Specs/Spec/Material/Dielectric/Properties/Property . . . . . | 403 | |--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------| | StackupFile/SupplierData/Specs/Spec/Material/Conductor . . . . . . . . . . . . . . . . . . . . . . | 405 | | StackupFile/SupplierData/Specs/Spec/Material/Conductor/Properties. . . . . . . . . . . . . | 407 | | StackupFile/SupplierData/Specs/Spec/Material/Conductor/Properties/PropertyName | 408 | | StackupFile/SupplierData/Specs/Spec/Material/Default_Thickness . . . . . . . . . . . . . . . | 410 | | StackupFile/SupplierData/Specs/Spec/Impedance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 411 | | StackupFile/SupplierData/Specs/Spec/Impedance/Single_Ended. . . . . . . . . . . . . . . . . . | 413 | | StackupFile/SupplierData/Specs/Spec/Impedance/Single_Ended/TraceWidth. . . . . . . | 415 | | StackupFile/SupplierData/Specs/Spec/Impedance/Single_Ended/RefPlane . . . . . . . . . | 417 | | StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide | 418 | | StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide/ TraceWidth. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 420 | | StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide/ Spacing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 422 | | StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide/ CoplanarSpacing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 423 | | StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide/ CoplanarTraceWidth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 424 | | StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide/ RefPlane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 426 | | StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Edge_Coupled . . . . . . | 427 | | StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Edge_Coupled/ TraceWidth. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 429 | | StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Edge_Coupled/Spacing 431 | | | StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Edge_Coupled/RefPlane 432 | | | StackupFile/SupplierData/Specs/Spec/Impedance/Single_Ended_Coplanar_Waveguide/ TraceWidth. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 435 | | StackupFile/SupplierData/Specs/Spec/Impedance/Single_Ended_Coplanar_Waveguide/ CoplanarSpacing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 437 | | StackupFile/SupplierData/Specs/Spec/Impedance/Single_Ended_Coplanar_Waveguide/ CoplanarTraceWidth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 438 | | StackupFile/SupplierData/Specs/Spec/Impedance/Single_Ended_Coplanar_Waveguide/ RefPlane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 440 | | StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Broadside_Coupled. . | 441 |
| StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Broadside_Coupled/ TraceWidth. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 443 | |----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------| | StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Broadside_Coupled/ TraceSeparation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 445 | | StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Broadside_Coupled/ RefPlane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 446 | | StackupFile/SupplierData/Stackup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 447 | | StackupFile/SupplierData/Stackup/Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 449 | | StackupFile/SupplierData/Stackup/Group/Layer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 451 | | StackupFile/SupplierData/Stackup/Group/Layer/SpecRef. . . . . . . . . . . . . . . . . . . . . . | 453 | | StackupFile/SupplierData/Stackup/Group/Layer/SpecRef/Material. . . . . . . . . . . . . . | 454 | | Stackup Schema File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 455 |
StackupFile
The base of ODB++ stackup content that includes material, impedance, and a design-based stackup requirement, followed by any number of suppler-based stackup solutions.
Diagram
Attributes
| Name | Type | Use | Default | Description | |--------------|-----------|----------|-----------|---------------------------------------------------------------------| | Version | xs:string | required | | Defines the ODB++ Version of the stackup.xml file | | DefaultUnits | UnitsType | optional | MIL | Carries the dimension Units value whenever referenced by the schema |
Children
- 'StackupFile/EdaData' on page 332
- 'StackupFile/SupplierData' on page 395
StackupFile/EdaData
Contains all the stackup-required content as delivered by the design source. This may be a generic section containing basic material requirements and impedance definition, or a full set of stackup definitions provided by a stackup software solution. This section is the basis for all stackup definitions and must not be altered in any way by stackup suppliers.
Parent
'StackupFile' on page 331
Diagram
Occurrence
0-1
Attributes
| Name | Type | Use | Default | Description | |-------------|-----------|----------|-----------|---------------------------------------------------------------------| | CompanyName | xs:string | required | | The name of the design company of the originating stackup | | ContactName | xs:string | optional | | The name of the contact of the originating stackup | | Address | xs:string | optional | | The postal address of the design company of the originating stackup |
<!-- image -->| Name | Type | Use | Default | Description | |-------------|-----------|----------|-----------|-------------------------------------------------------------------| | PnoneNumber | xs:string | optional | | The phone number of the design company of the originating stackup | | Comment | xs:string | optional | | Open comment from the design company of the originating stackup |
Children
- 'StackupFile/EdaData/Specs' on page 334
- 'StackupFile/EdaData/Stackup' on page 385
StackupFile/EdaData/Specs
Contains a list of material specifications and impedance requirements for the stack design. Each specification is represented by an instance of the Spec element.
Parent
'StackupFile/EdaData' on page 332
Diagram
Occurrence
1
Children
'StackupFile/EdaData/Specs/Spec' on page 335
<!-- image -->StackupFile/EdaData/Specs/Spec
An individual specification defining the collection of materials and impedance requirements. The Spec is selected through the use of the SpecName attribute.
Parent
'StackupFile/EdaData/Specs' on page 334
Diagram
Occurrence
1-n
Attributes
| Name | Type | Use | Default | Description | |----------|-----------|----------|-----------|-------------------------------------| | SpecName | xs:string | required | | The name referencing the given Spec |
Children
- 'StackupFile/EdaData/Specs/Spec/Material' on page 336
- 'StackupFile/EdaData/Specs/Spec/Impedance' on page 348
StackupFile/EdaData/Specs/Spec/Material
A Material specification defining a specific material, dielectric or conductor. The Material is selected through the use of the MaterialName attribute.
Parent
'StackupFile/EdaData/Specs/Spec' on page 335
Diagram
Occurrence
0-n
Attributes
| Name | Type | Use | Default | Description | |--------------|-----------|----------|-----------|-----------------------------------------| | MaterialName | xs:string | required | | The name referencing the given Material |
Children
- 'StackupFile/EdaData/Specs/Spec/Material/Dielectric' on page 337
- 'StackupFile/EdaData/Specs/Spec/Material/Conductor' on page 342
- 'StackupFile/EdaData/Specs/Spec/Material/Default_Thickness' on page 347
StackupFile/EdaData/Specs/Spec/Material/ Dielectric
The definition of a specific piece of dielectric material.
Parent
'StackupFile/EdaData/Specs/Spec/Material' on page 336
Diagram
Occurrence
0-1
Attributes
| Name | Type | Use | Default | Description | |--------------------|-----------------|----------|-----------|--------------------------------------------------------------------------------------| | DielectricType | DielectricTyp e | required | | Defines the generic type of dielectric materials as prepreg, core, or other | | OtherSubType | OtherType | optional | | A list of material definitions that are most often used when DielectricType is OTHER | | MaterialRefere nce | xs:string | optional | | Free text providing the material supplier's reference name |
<!-- image -->| Name | Type | Use | Default | Description | |--------------------------|-----------|----------|-----------|-------------------------------------------------------------| | GlassStyle_Co nstruction | xs:string | optional | | Free text describing the Prepreg glass or Core construction | | ResinContent_ Percent | xs:double | optional | | The percentage of resin in the dielectric material | | Description | xs:string | optional | | Open description of the dielectric material | | Comment | xs:string | optional | | Open comment on the dielectric material |
Children
'StackupFile/EdaData/Specs/Spec/Material/Dielectric/Properties' on page 339
StackupFile/EdaData/Specs/Spec/Material/ Dielectric/Properties
Contains a list of Properties related to the material behavior. Material's electrical characteristics are influenced by the frequency of the impedance net. The Property is selected through the use of the PropertyName attribute.
Parent
'StackupFile/EdaData/Specs/Spec/Material/Dielectric' on page 337
Diagram
Occurrence
0-n
Attributes
| Name | Type | Use | Default | Description | |--------------|-----------|----------|-----------|--------------------------------------------------| | PropertyName | xs:string | required | | The name referencing the given set of Properties |
Children
'StackupFile/EdaData/Specs/Spec/Material/Dielectric/Properties/Property' on page 340
<!-- image -->StackupFile/EdaData/Specs/Spec/Material/ Dielectric/Properties/Property
A specific property and the related material characteristics.
Parent
'StackupFile/EdaData/Specs/Spec/Material/Dielectric/Properties' on page 339
Diagram
Occurrence
1-n
Attributes
| Name | Type | Use | Default | Description | |------------------------|-----------|----------|-----------|-----------------------------------------------------------------------| | FrequencyVal | xs:double | optional | | The value of the single frequency. | | Units | UnitsType | optional | GHz | The unit of the FrequenceVal frequency. | | DielectricConst ant_Dk | xs:double | optional | | The Dielectric Constant (DK) at the specified FrequencyVal frequency. | | LossTangent_ Df | xs:double | optional | | The Loss Tangent (Df) at the specified FrequencyVal frequency. |
<!-- image -->| Name | Type | Use | Default | Description | |---------------------|-----------|----------|-----------|--------------------------------------------------------------------------------------------------------------------------------------------------------| | Thickness | xs:double | optional | | The overriding thickness of the dielectric material. The unit of measure is governed by StackupFile -> DefaultUnits, which is by default MIL. | | Finished_Thick ness | xs:double | optional | | The overriding finished thickness of the dielectric material. The unit of measure is governed by StackupFile- > DefaultUnits, which is by default MIL. | | Units_Thicknes s | UnitsType | optional | MIL | The unit of measure used by the Thickness and Finished_Thickness attributes. This unit is governed by StackupFile -> DefaultUnits. |
StackupFile/EdaData/Specs/Spec/Material/ Conductor
The definition of a specific piece of conductive material.
Parent
'StackupFile/EdaData/Specs/Spec/Material' on page 336
Diagram
Occurrence
0-1
Attributes
| Name | Type | Use | Default | Description | |----------------------|----------------|----------|-----------|------------------------------------------------------------------------------------------------------------------------------| | ConductorType | ConductorTyp e | required | | The type of conductor (COPPER or OTHER). | | CopperWeight _oz_ft2 | xs:double | optional | | Mainly, a historical means to specify copper thickness by using the value of the Thickness attribute located under Material. | | Description | xs:string | optional | | Open description of the conductive material. | | Comment | xs:string | optional | | Open comment on the conductive material. |
<!-- image -->Children
'StackupFile/EdaData/Specs/Spec/Material/Conductor/Properties' on page 344
StackupFile/EdaData/Specs/Spec/Material/ Conductor/Properties
Contains a list of Properties related to the material behavior. The Property is selected through the use of the PropertyName attribute.
Parent
'StackupFile/EdaData/Specs/Spec/Material/Conductor' on page 342
Diagram
Occurrence
0-n
Attributes
| Name | Type | Use | Default | Description | |--------------|-----------|----------|-----------|--------------------------------------------------| | PropertyName | xs:string | required | | The name referencing the given set of Properties |
Children
'StackupFile/EdaData/Specs/Spec/Material/Conductor/Properties/Property' on page 345
<!-- image -->StackupFile/EdaData/Specs/Spec/Material/ Conductor/Properties/Property
A specific property and the related material characteristics.
Parent
'StackupFile/EdaData/Specs/Spec/Material/Conductor/Properties' on page 344
Diagram
Occurrence
1
Attributes
| Name | Type | Use | Default | Description | |------------------------------------|-----------|----------|-----------|---------------------------------------------------------------------| | Conductivity_ mho_cm | xs:double | optional | | The Conductivity of copper measured in MHO/CM. | | SurfaceRoughn essFacingCore _Rz | xs:double | optional | | The surface roughness of copper facing the core, measured in Rz. | | SurfaceRoughn essFacingPrepr eg_Rz | xs:double | optional | | The surface roughness of copper facing the prepreg, measured in Rz. |
<!-- image -->| Name | Type | Use | Default | Description | |--------------------------|-----------|----------|-----------|-------------------------------------------------------------------------------------------------------------------------------------------------------| | SurfaceRoughn essFoil_Rz | xs:double | optional | | The surface roughness of the copper foil or sheet materials measured in Rz. | | DielectricConst ant_Dk | xs:double | optional | | The Dielectric Constant (DK) contributed to the resin during the lamination process. | | LossTangent_ Df | xs:double | optional | | The Loss Tangent (Df) contributed to the resin during the lamination process. | | Thickness | xs:double | optional | | The overriding thickness of the conductor material. The unit of measure is governed by StackupFile -> DefaultUnits, which is by default MIL. | | Finished_Thick ness | xs:double | optional | | The overriding finished thickness of the conductor material. The unit of measure is governed by StackupFile -> DefaultUnits, which is by default MIL. | | Units_Thicknes s | UnitsType | optional | ML | The unit of measure used by the Thickness and Finished_Thickness attributes. This unit is governed by StackupFile -> DefaultUnits. |
StackupFile/EdaData/Specs/Spec/Material/ Default_Thickness
The thickness definition for the supplier-delivered dielectric or conductor material.
Parent
'StackupFile/SupplierData/Specs/Spec/Material' on page 399
Diagram
Occurrence
1
Attributes
| Name | Type | Use | Default | Description | |---------------------|-----------|----------|-----------|------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Thickness | xs:double | required | | The default thickness of the dielectric or conductor material. The unit of measure is governed by StackupFile -> DefaultUnits, which is by default MIL. | | Finished_Thick ness | xs:double | optional | | The default finished thickness of the dielectric or conductor material. The unit of measure is governed by StackupFile -> DefaultUnits, which is by default MIL. | | Units | xs:double | optional | MIL | The unit of measure used by the Thickness and Finished_Thickness attributes. This unit is governed by StackupFile -> DefaultUnits. |
<!-- image -->StackupFile/EdaData/Specs/Spec/Impedance
An Impedance specification defining the general impedance goal and physical characteristics. The Impedance is selected through the use of the ImplName attribute.
Parent
'StackupFile/EdaData/Specs/Spec' on page 335
Diagram
Occurrence
0-n
<!-- image -->Attributes
| Name | Type | Use | Default | Description | |---------------|------------|----------|-----------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | ImpName | xs:string | required | | The name referencing the given Impedance. | | ZoValOhms | xs:double | optional | | Single-ended impedance target value in Ohms. | | ZoPlusVal | xs:double | optional | | A positive value representing the plus value to add to the target single-ended impedance value ZoValOhms (tolerance). The use of ZoPlusVal is determined by the ZoValPercent value. | | ZoMinusVal | xs:double | optional | | A positive value representing the plus value to subtract from the target single-ended impedance value ZoValOhms (tolerance). The use of ZoPMinusVal is determined by the ZoValPercent value. | | ZoValPercent | xs:boolean | optional | true | Single-ended tolerance definition: true -apercentage of ZoValOhms false -an absolute value to add or subtract from ZoValOhms | | ZDiffValOhms | xs:double | optional | | Differential impedance target value in Ohms. | | ZDiffPlusVal | xs:double | optional | | A positive value representing the plus value to add to the target differential impedance value ZDiffValOhms (tolerance). The use of ZDiffPlusVal is determined by the ZDiffValPercent value. | | ZDiffMinusVal | xs:double | optional | | A positive value representing the plus value to subtract from the target differential impedance value ZDiffValOhms (tolerance). The use of ZDiffMinusVal is determined by the ZDiffValPercent value. |
| Name | Type | Use | Default | Description | |------------------|------------|----------|-----------|------------------------------------------------------------------------------------------------------------------------------------| | ZDiffValPerce nt | xs:boolean | optional | true | Differential tolerance definition: true -apercentage of ZDiffValOhms false -an absolute value to add or subtract from ZDiffValOhms |
Children
- 'StackupFile/EdaData/Specs/Spec/Impedance/Single_Ended' on page 351
- 'StackupFile/EdaData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide' on page 356
- 'StackupFile/EdaData/Specs/Spec/Impedance/Differential_Edge_Coupled' on page 365
- 'StackupFile/EdaData/Specs/Spec/Impedance/Single_Ended_Coplanar_Waveguide' on page 371
- 'StackupFile/EdaData/Specs/Spec/Impedance/Differential_Broadside_Coupled' on page 379
StackupFile/EdaData/Specs/Spec/Impedance/ Single_Ended
A representation of the single-ended impedance requirement.
Parent
'StackupFile/EdaData/Specs/Spec/Impedance' on page 348
Diagram
Occurrence
0-n
Attributes
| Name | Type | Use | Default | Description | |-------------------|-----------|----------|-----------|-----------------------------------------------------------------------------------------------------------------------------------------------| | LayerName | xs:string | required | | The Layer name referencing the given Impedance Type. | | Structure | Structure | optional | | The impedance structure definition in the areas of stripline, microstrip, or Coplanar waveguide. | | ZoCalculatedO hms | xs:double | optional | | If the design source has an impedance simulator, this attribute contains the calculated result for the given single-ended impedance instance. |
<!-- image -->Children
- 'StackupFile/EdaData/Specs/Spec/Impedance/Single_Ended/TraceWidth' on page 353
- 'StackupFile/EdaData/Specs/Spec/Impedance/Single_Ended/RefPlane' on page 355
StackupFile/EdaData/Specs/Spec/Impedance/ Single_Ended/TraceWidth
Contains the desired trace width to use for the target impedance.
Parent
'StackupFile/EdaData/Specs/Spec/Impedance/Single_Ended' on page 351
Diagram
Occurrence
1
Attributes
| Name | Type | Use | Default | Description | |----------|-----------|----------|-----------|--------------------------------------------------------------------------------------------------------------------------| | Val | xs:double | required | | The target trace width of the related conductor. | | Units | UnitsType | optional | MIL | The unit of measure used by the Val attribute. | | PlusVal | xs:double | optional | | A positive value representing the plus tolerance value to add to the target trace value in the Val attribute. | | MinusVal | xs:double | optional | | A positive value representing the negative tolerance value to subtract from the target trace value in the Val attribute. |
<!-- image -->| Name | Type | Use | Default | Description | |------------|------------|----------|-----------|---------------------------------------------------------------------------------------------------------------------------------------------------------| | TolPercent | xs:boolean | optional | false | Trace width tolerance definition: true -apercentage of the Val attribute value false -an absolute value to add or subtract from the Val attribute value |
StackupFile/EdaData/Specs/Spec/Impedance/ Single_Ended/RefPlane
Contains the list of layers that represent the reference planes in impedance calculation.
Parent
'StackupFile/EdaData/Specs/Spec/Impedance/Single_Ended' on page 351
Diagram
Occurrence
0-2
Attributes
| Name | Type | Use | Default | Description | |--------------|-----------|----------|-----------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | RefLayerName | xs:string | required | | The LayerName value of the layer found under StackupFile -> EdaData -> Stackup -> Group -> Layer. This value represents a reference plane used during the impedance calculation. |
<!-- image -->StackupFile/EdaData/Specs/Spec/Impedance/ Differential_Coplanar_Waveguide
A representation of the differential Coplanar waveguide impedance requirement.
Parent
'StackupFile/EdaData/Specs/Spec/Impedance' on page 348
Diagram
Occurrence
0-n
Attributes
| Name | Type | Use | Default | Description | |-----------|-----------|----------|-----------|------------------------------------------------------| | LayerName | xs:string | required | | The Layer name referencing the given Impedance Type. |
<!-- image -->| Name | Type | Use | Default | Description | |----------------------|-----------|----------|-----------|-----------------------------------------------------------------------------------------------------------------------------------------------| | Structure | Structure | optional | | The impedance structure definition in the areas of stripline, microstrip, or Coplanar waveguide. | | ZoCalculatedO hms | xs:double | optional | | If the design source has an impedance simulator, this attribute contains the calculated result for the given single-ended impedance instance. | | ZDiffCalculate dOhms | xs:double | optional | | If the design source has an impedance simulator, this attribute contains the calculated result for the given differential impedance instance. | | InsertionLoss | xs:double | optional | | The resulting loss of single power. | | InsertionLossU nits | UnitsType | optional | DB/INCH | Units for InsertionLoss. |
Children
- 'StackupFile/EdaData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide/ TraceWidth' on page 358
- 'StackupFile/EdaData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide/ Spacing' on page 360
- 'StackupFile/EdaData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide/ CoplanarSpacing' on page 361
- 'StackupFile/EdaData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide/ CoplanarTraceWidth' on page 362
- 'StackupFile/EdaData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide/ RefPlane' on page 364
StackupFile/EdaData/Specs/Spec/Impedance/ Differential_Coplanar_Waveguide/TraceWidth
Contains the desired trace width to use for the target impedance.
Parent
'StackupFile/EdaData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide' on page 356
Diagram
Occurrence
1
Attributes
| Name | Type | Use | Default | Description | |----------|-----------|----------|-----------|--------------------------------------------------------------------------------------------------------------------------------| | Val | xs:double | required | | The target trace width of the related conductor. | | Units | UnitsType | optional | MIL | The unit of measure used by the Val attribute. | | PlusVal | xs:double | optional | | A positive value representing the plus tolerance value to add to the target trace width value in the Val attribute. | | MinusVal | xs:double | optional | | A positive value representing the negative tolerance value to subtract from the target trace width value in the Val attribute. |
<!-- image -->| Name | Type | Use | Default | Description | |------------|------------|----------|-----------|---------------------------------------------------------------------------------------------------------------------------------------------------------| | TolPercent | xs:boolean | optional | false | Trace width tolerance definition: true -apercentage of the Val attribute value false -an absolute value to add or subtract from the Val attribute value |
StackupFile/EdaData/Specs/Spec/Impedance/ Differential_Coplanar_Waveguide/Spacing
Contains the desired spacing between copper for the target impedance.
Parent
'StackupFile/EdaData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide' on page 356
Diagram
Occurrence
1
Attributes
| Name | Type | Use | Default | Description | |--------|-----------|----------|-----------|-----------------------------------------------| | Val | xs:double | required | | The target spacing for the related conductor | | Units | UnitsType | optional | MIL | The unit of measure used by the Val attribute |
<!-- image -->StackupFile/EdaData/Specs/Spec/Impedance/ Differential_Coplanar_Waveguide/ CoplanarSpacing
Contains the desired Coplanar spacing to use for the target impedance.
Parent
'StackupFile/EdaData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide' on page 356
Diagram
Occurrence
1
Attributes
| Name | Type | Use | Default | Description | |--------|-----------|----------|-----------|-------------------------------------------------------| | Val | xs:double | required | | The target Coplanar spacing for the related conductor | | Units | UnitsType | optional | MIL | The unit of measure used by the Val attribute |
<!-- image -->StackupFile/EdaData/Specs/Spec/Impedance/ Differential_Coplanar_Waveguide/ CoplanarTraceWidth
Contains the desired Coplanar trace width to use for the target impedance. When using reference planes, this element is not to be defined.
Parent
'StackupFile/EdaData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide' on page 356
Diagram
Occurrence
0-1
Attributes
| Name | Type | Use | Default | Description | |---------|-----------|----------|-----------|------------------------------------------------------------------------------------------------------------------------------| | Val | xs:double | required | | The target Coplanar trace width of the related conductor. | | Units | UnitsType | optional | MIL | The unit of measure used by the Val attribute. | | PlusVal | xs:double | optional | | A positive value representing the plus tolerance value to add to the target Coplanar trace width value in the Val attribute. |
<!-- image -->| Name | Type | Use | Default | Description | |------------|------------|----------|-----------|---------------------------------------------------------------------------------------------------------------------------------------------------------| | MinusVal | xs:double | optional | | A positive value representing the negative tolerance value to subtract from the target Coplanar trace width value in the Val attribute. | | TolPercent | xs:boolean | optional | false | Trace width tolerance definition: true -apercentage of the Val attribute value false -an absolute value to add or subtract from the Val attribute value |
StackupFile/EdaData/Specs/Spec/Impedance/ Differential_Coplanar_Waveguide/RefPlane
Contains the list of layers that represent the reference planes in impedance calculation.
Parent
'StackupFile/EdaData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide' on page 356
Diagram
Occurrence
0-2
Attributes
| Name | Type | Use | Default | Description | |--------------|-----------|----------|-----------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | RefLayerName | xs:string | required | | The LayerName value of the layer found under StackupFile -> EdaData -> Stackup -> Group -> Layer. This value represents a reference plane used during the impedance calculation. |
<!-- image -->StackupFile/EdaData/Specs/Spec/Impedance/ Differential_Edge_Coupled
A representation of the edge-coupled differential impedance requirement.
Parent
'StackupFile/EdaData/Specs/Spec/Impedance' on page 348
Diagram
Occurrence
0-n
Attributes
| Name | Type | Use | Default | Description | |-----------|-----------|----------|-----------|--------------------------------------------------------------------------------------------------| | LayerName | xs:string | required | | The Layer name referencing the given Impedance Type. | | Structure | Structure | optional | | The impedance structure definition in the areas of stripline, microstrip, or Coplanar waveguide. |
<!-- image -->| Name | Type | Use | Default | Description | |----------------------|--------------------|----------|-----------|-----------------------------------------------------------------------------------------------------------------------------------------------| | ZoCalculatedO hms | xs:double | optional | | If the design source has an impedance simulator, this attribute contains the calculated result for the given single-ended impedance instance. | | ZDiffCalculate dOhms | xs:double | optional | | If the design source has an impedance simulator, this attribute contains the calculated result for the given differential impedance instance. | | InsertionLoss | xs:double | optional | | The resulting loss of single power. | | InsertionLossU nits | InsertionLoss Type | optional | DB/INCH | Units for InsertionLoss. |
Children
- 'StackupFile/EdaData/Specs/Spec/Impedance/Differential_Edge_Coupled/ TraceWidth' on page 367
- 'StackupFile/EdaData/Specs/Spec/Impedance/Differential_Edge_Coupled/Spacing' on page 369
- 'StackupFile/EdaData/Specs/Spec/Impedance/Differential_Edge_Coupled/RefPlane' on page 370
StackupFile/EdaData/Specs/Spec/Impedance/ Differential_Edge_Coupled/TraceWidth
Contains the desired trace width to use for the target impedance.
Parent
'StackupFile/EdaData/Specs/Spec/Impedance/Differential_Edge_Coupled' on page 365
Diagram
Occurrence
1
Attributes
| Name | Type | Use | Default | Description | |----------|-----------|----------|-----------|--------------------------------------------------------------------------------------------------------------------------------| | Val | xs:double | required | | The target trace width of the related conductor. | | Units | UnitsType | optional | MIL | The unit of measure used by the Val attribute. | | PlusVal | xs:double | optional | | A positive value representing the plus tolerance value to add to the target trace width value in the Val attribute. | | MinusVal | xs:double | optional | | A positive value representing the negative tolerance value to subtract from the target trace width value in the Val attribute. |
<!-- image -->| Name | Type | Use | Default | Description | |------------|------------|----------|-----------|---------------------------------------------------------------------------------------------------------------------------------------------------------| | TolPercent | xs:boolean | optional | false | Trace width tolerance definition: true -apercentage of the Val attribute value false -an absolute value to add or subtract from the Val attribute value |
StackupFile/EdaData/Specs/Spec/Impedance/ Differential_Edge_Coupled/Spacing
Contains the desired spacing between copper for the target impedance.
Parent
'StackupFile/EdaData/Specs/Spec/Impedance/Differential_Edge_Coupled' on page 365
Diagram
Occurrence
1
Attributes
| Name | Type | Use | Default | Description | |--------|-----------|----------|-----------|------------------------------------------------| | Val | xs:double | required | | The target spacing for the related conductor. | | Units | UnitsType | optional | MIL | The unit of measure used by the Val attribute. |
<!-- image -->StackupFile/EdaData/Specs/Spec/Impedance/ Differential_Edge_Coupled/RefPlane
Contains the list of layers that represent the reference planes in impedance calculation.
Parent
'StackupFile/EdaData/Specs/Spec/Impedance/Differential_Edge_Coupled' on page 365
Diagram
Occurrence
0-2
Attributes
| Name | Type | Use | Default | Description | |--------------|-----------|----------|-----------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | RefLayerName | xs:string | required | | The LayerName value of the layer found under StackupFile -> EdaData -> Stackup -> Group -> Layer. This value represents a reference plane used during the impedance calculation. |
<!-- image -->StackupFile/EdaData/Specs/Spec/Impedance/ Single_Ended_Coplanar_Waveguide
A representation of the Coplanar single-ended waveguide impedance requirement.
Parent
'StackupFile/EdaData/Specs/Spec/Impedance' on page 348
Diagram
Occurrence
0-n
Attributes
| Name | Type | Use | Default | Description | |-----------|-----------|----------|-----------|--------------------------------------------------------------------------------------------------| | LayerName | xs:string | required | | The Layer name referencing the given Impedance Type. | | Structure | Structure | optional | | The impedance structure definition in the areas of stripline, microstrip, or Coplanar waveguide. |
<!-- image -->| Name | Type | Use | Default | Description | |----------------------|-----------|----------|-----------|-----------------------------------------------------------------------------------------------------------------------------------------------| | ZoCalculatedO hms | xs:double | optional | | If the design source has an impedance simulator, this attribute contains the calculated result for the given single-ended impedance instance. | | ZDiffCalculate dOhms | xs:double | optional | | If the design source has an impedance simulator, this attribute contains the calculated result for the given differential impedance instance. |
Children
- 'StackupFile/EdaData/Specs/Spec/Impedance/Single_Ended_Coplanar_Waveguide/ CoplanarTraceWidth' on page 376
- 'StackupFile/EdaData/Specs/Spec/Impedance/Single_Ended_Coplanar_Waveguide/ CoplanarSpacing' on page 375
- 'StackupFile/EdaData/Specs/Spec/Impedance/Single_Ended_Coplanar_Waveguide/ TraceWidth' on page 373
- 'StackupFile/EdaData/Specs/Spec/Impedance/Single_Ended_Coplanar_Waveguide/ RefPlane' on page 378
StackupFile/EdaData/Specs/Spec/Impedance/ Single_Ended_Coplanar_Waveguide/ TraceWidth
Contains the desired trace width to use for the target impedance.
Parent
'StackupFile/EdaData/Specs/Spec/Impedance/Single_Ended_Coplanar_Waveguide' on page 371
Diagram
Occurrence
1
Attributes
| Name | Type | Use | Default | Description | |----------|-----------|----------|-----------|--------------------------------------------------------------------------------------------------------------------------| | Val | xs:double | required | | The target trace width of the related conductor. | | Units | UnitsType | optional | MIL | The unit of measure used by the Val attribute. | | PlusVal | xs:double | optional | | A positive value representing the plus tolerance value to add to the target trace value in the Val attribute. | | MinusVal | xs:double | optional | | A positive value representing the negative tolerance value to subtract from the target trace value in the Val attribute. |
<!-- image -->| Name | Type | Use | Default | Description | |------------|------------|----------|-----------|---------------------------------------------------------------------------------------------------------------------------------------------------------| | TolPercent | xs:boolean | optional | false | Trace width tolerance definition: true -apercentage of the Val attribute value false -an absolute value to add or subtract from the Val attribute value |
StackupFile/EdaData/Specs/Spec/Impedance/ Single_Ended_Coplanar_Waveguide/ CoplanarSpacing
Contains the desired spacing between copper for the target impedance.
Parent
'StackupFile/EdaData/Specs/Spec/Impedance/Single_Ended_Coplanar_Waveguide' on page 371
Diagram
Occurrence
1
Attributes
| Name | Type | Use | Default | Description | |--------|-----------|----------|-----------|--------------------------------------------------------| | Val | xs:double | required | | The target Coplanar spacing for the related conductor. | | Units | UnitsType | optional | MIL | The unit of measure used by the Val attribute. |
<!-- image -->StackupFile/EdaData/Specs/Spec/Impedance/ Single_Ended_Coplanar_Waveguide/ CoplanarTraceWidth
Contains the desired coplanar trace width to use for the target impedance. When using reference planes, this element is not to be defined.
Parent
'StackupFile/EdaData/Specs/Spec/Impedance/Single_Ended_Coplanar_Waveguide' on page 371
Diagram
Occurrence
0-1
Attributes
| Name | Type | Use | Default | Description | |---------|-----------|----------|-----------|------------------------------------------------------------------------------------------------------------------------------| | Val | xs:double | required | | The target Coplanar trace width of the related conductor. | | Units | UnitsType | optional | MIL | The unit of measure used by the Val attribute. | | PlusVal | xs:double | optional | | A positive value representing the plus tolerance value to add to the target Coplanar trace width value in the Val attribute. |
<!-- image -->| Name | Type | Use | Default | Description | |------------|------------|----------|-----------|---------------------------------------------------------------------------------------------------------------------------------------------------------| | MinusVal | xs:double | optional | | A positive value representing the negative tolerance value to subtract from the target Coplanar trace width value in the Val attribute. | | TolPercent | xs:boolean | optional | false | Trace width tolerance definition: true -apercentage of the Val attribute value false -an absolute value to add or subtract from the Val attribute value |
StackupFile/EdaData/Specs/Spec/Impedance/ Single_Ended_Coplanar_Waveguide/RefPlane
Contains the list of layers that represent the reference planes in impedance calculation.
Parent
'StackupFile/EdaData/Specs/Spec/Impedance/Single_Ended_Coplanar_Waveguide' on page 371
Diagram
Occurrence
0-2
Attributes
| Name | Type | Use | Default | Description | |--------------|-----------|----------|-----------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | RefLayerName | xs:string | required | | The LayerName value of the layer found under StackupFile -> EdaData -> Stackup -> Group -> Layer. This value represents a reference plane used during the impedance calculation. |
<!-- image -->StackupFile/EdaData/Specs/Spec/Impedance/ Differential_Broadside_Coupled
A representation of the broadside-coupled differential impedance requirement.
Parent
'StackupFile/EdaData/Specs/Spec/Impedance' on page 348
Diagram
Occurrence
0-n
Attributes
| Name | Type | Use | Default | Description | |-----------|-----------|----------|-----------|-------------------------------------------------------------------------------------------------| | LayerName | xs:string | required | | The Layer name referencing the given Impedance Type | | Structure | Structure | optional | | The impedance structure definition in the areas of stripline, microstrip, or Coplanar waveguide |
<!-- image -->| Name | Type | Use | Default | Description | |----------------------|--------------------|----------|-----------|----------------------------------------------------------------| | ZoCalculatedO hm | xs:double | optional | | The calculated result for this single-ended impedance instance | | ZDiffCalculate dOhms | xs:double | optional | | The calculated result for this differential impedance instance | | InsertionLoss | xs:double | optional | | The resulting loss of single power | | InsertionLossU nits | InsertionLoss Type | optional | DB/INCH | Units for InsertionLoss |
Children
- 'StackupFile/EdaData/Specs/Spec/Impedance/Differential_Broadside_Coupled/ TraceWidth' on page 381
- 'StackupFile/EdaData/Specs/Spec/Impedance/Differential_Broadside_Coupled/ TraceSeparation' on page 383
- 'StackupFile/EdaData/Specs/Spec/Impedance/Differential_Broadside_Coupled/ RefPlane' on page 384
StackupFile/EdaData/Specs/Spec/Impedance/ Differential_Broadside_Coupled/TraceWidth
Contains the desired trace width to use for the target impedance.
Parent
'StackupFile/EdaData/Specs/Spec/Impedance/Differential_Broadside_Coupled' on page 379
Diagram
Occurrence
1
Attributes
| Name | Type | Use | Default | Description | |----------|-----------|----------|-----------|--------------------------------------------------------------------------------------------------------------------------------| | Val | xs:double | required | | The target trace width of the related conductor. | | Units | UnitsType | optional | MIL | The unit of measure used by the Val attribute. | | PlusVal | xs:double | optional | | A positive value representing the plus tolerance value to add to the target trace width value in the Val attribute. | | MinusVal | xs:double | optional | | A positive value representing the negative tolerance value to subtract from the target trace width value in the Val attribute. |
<!-- image -->| Name | Type | Use | Default | Description | |------------|------------|----------|-----------|---------------------------------------------------------------------------------------------------------------------------------------------------------| | TolPercent | xs:boolean | optional | false | Trace width tolerance definition: true -apercentage of the Val attribute value false -an absolute value to add or subtract from the Val attribute value |
StackupFile/EdaData/Specs/Spec/Impedance/ Differential_Broadside_Coupled/ TraceSeparation
Contains the desired distance between the related conductors.
Parent
'StackupFile/EdaData/Specs/Spec/Impedance/Differential_Broadside_Coupled' on page 379
Diagram
Occurrence
1
Attributes
| Name | Type | Use | Default | Description | |---------|------------|----------|-----------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Val | xs:double | required | | The target copper separation value for the related conductors | | Units | UnitsType | optional | MIL | The unit of measure used by the Val attribute | | IsPitch | xs:boolean | optional | true | Trace Separation definition: true -the spacing between the conductors is measured from center line to center line, or pitch false -the spacing between the conductors is measured from edge to edge |
<!-- image -->StackupFile/EdaData/Specs/Spec/Impedance/ Differential_Broadside_Coupled/RefPlane
Contains the list of layers that represent the reference planes in impedance calculation.
Parent
'StackupFile/EdaData/Specs/Spec/Impedance/Differential_Broadside_Coupled' on page 379
Diagram
Occurrence
0-2
Attributes
| Name | Type | Use | Default | Description | |--------------|-----------|----------|-----------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | RefLayerName | xs:string | required | | The LayerName value of the layer found under StackupFile -> EdaData -> Stackup -> Group -> Layer. This value represents a reference plane used during the impedance calculation. |
<!-- image -->StackupFile/EdaData/Stackup
Contains the stackup representation as delivered by the design source.
Parent
'StackupFile/EdaData' on page 332
Diagram
Occurrence
1
Attributes
| Name | Type | Use | Default | Description | |-------------------|-----------|----------|-----------|-----------------------------------------------------------------------------------------------------------| | StackupName | xs:string | required | | The name referencing the given Stackup. | | StackupThickn ess | xs:double | required | | The target board thickness in units defined in the Units attribute. | | PlusTol | xs:double | optional | | A positive value representing the plus value to add to the target stackup thickness the StackupThickness. |
<!-- image -->| Name | Type | Use | Default | Description | |------------------------|----------------|----------|-----------|------------------------------------------------------------------------------------------------------------------------------------------------------| | MinusTol | xs:double | optional | | A positive value representing the negative value to subtract from the target stackup thickness StackupThickness. | | Units | UnitsType | optional | MIL | The unit of measure used by the StackupThickness, PlusTol, and MinusTol attributes. This unit of measure is governed by StackupFile -> DefaultUnits. | | WhereMeasure d | WhereMeasur ed | optional | METAL | An enumerated value indicating where to measure the StackupThickness value. | | TotalLaminatio nCycles | xs:integer | optional | | The total number of lamination cycles required to complete the booking process. |
Children
'StackupFile/EdaData/Stackup/Group' on page 387
StackupFile/EdaData/Stackup/Group
A stackup is created from Groups. A Group is a collection of Materials in which conductor materials are tied to copper layers of the design. Each series is represented from the top of the stack to the bottom.
Parent
'StackupFile/EdaData/Stackup' on page 385
Diagram
Occurrence
1-n
Attributes
| Name | Type | Use | Default | Description | |-------------------------|------------|----------|-----------|-------------------------------------------------------------------------------------------------------------------------| | GroupName | xs:string | required | | The name referencing the given Group. | | GroupThicknes s | xs:double | optional | | The total thickness for the group of layers, in units defined in the Units attribute. | | Units | UnitsType | optional | MIL | The unit of measure used by the GroupThickness attribute. This unit is governed by StackupFile -> DefaultUnits. | | NumberOfLam inateCycles | xs:integer | optional | | The total number of lamination cycles to subject the layer group, from the beginning to the end of the booking process. |
<!-- image -->Children
'StackupFile/EdaData/Stackup/Group/Layer' on page 389
StackupFile/EdaData/Stackup/Group/Layer
A Layer definition within the Group.
Parent
'StackupFile/EdaData/Stackup/Group' on page 387
Diagram
Occurrence
1-n
Attributes
| Name | Type | Use | Default | Description | |-----------|-----------|----------|-----------|--------------------------------------------------------------------------| | LayerName | xs:string | required | | The name of layer used within the design. | | LayerType | LayerType | optional | DOCUME NT | An enumerated list of layer types representing the purpose of the layer. |
<!-- image -->| Name | Type | Use | Default | Description | |---------------------|-----------|----------|-----------|---------------------------------------------------------------------------------------------------------------------------------------------------| | LayerSubType | SideType | optional | | An enumerated list of layer subtypes that refine the LayerType value. For example, a LayerType DRILL with a SubType BACKDRILL. | | MechStartLaye rName | xs:string | optional | | If LayerType has the value of DRILL or ROUT, this attribute contains the name of the initial layer where the material is mechanically penetrated. | | MechEndLayer Name | xs:string | optional | | If LayerType has the value of DRILL or ROUT, this attribute contains the name of the final layer where the material is mechanically penetrated. | | Side | SideType | optional | NONE | An enumerated list of a values declaring the relative position of the layer within the stackup. | | Description | xs:string | optional | | Open description from the design company of the originating layer. | | Comment | xs:string | optional | | Open comment from the design company of the originating layer. |
Children
'StackupFile/EdaData/Stackup/Group/Layer/SpecRef' on page 391
StackupFile/EdaData/Stackup/Group/Layer/ SpecRef
The list of Material and Impedance Specs, and conductor requirements for a layer.
Parent
'StackupFile/EdaData/Stackup/Group/Layer' on page 389
Diagram
Occurrence
0-n
Attributes
| Name | Type | Use | Default | Description | |-------------------|-----------|----------|-----------|--------------------------------------------------| | MaterialSpecN ame | xs:string | required | | The name referencing the selected Material Spec | | ImpSpecName | xs:string | optional | | The name referencing the selected Impedance Spec |
Children
- 'StackupFile/EdaData/Stackup/Group/Layer/SpecRef/Material' on page 392
- 'StackupFile/EdaData/Stackup/Group/Layer/SpecRef/Impedance' on page 394
StackupFile/EdaData/Stackup/Group/Layer/ SpecRef/Material
Defines the Material requirements for a layer.
Parent
'StackupFile/EdaData/Stackup/Group/Layer/SpecRef' on page 391
Diagram
Occurrence
0-1
Attributes
| Name | Type | Use | Default | Description | |--------------|-----------|----------|-----------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | MaterialName | xs:string | required | | The name referencing the designated Material within the referenced SpecName. | | PropertyName | xs:string | optional | | The name referencing the designated Properties within the referenced Material. If only one Property is defined, then this Property is considered the default, and the existence of the attribute FrequencyVal is not required. |
<!-- image -->| Name | Type | Use | Default | Description | |--------------------|-----------|----------|-----------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | FrequencyVal | xs:double | optional | | The frequency of the signal on the net. This attribute can reference additional material content when referenced into PropertyName. If only one Property is defined, then it is considered the default, and the existence of this attribute is not required. | | CopperAreaPre cent | xs:double | optional | | Percentage calculated by dividing the copper area of the layer by the total area of the layer laminate. | | TraceWidthTo p | xs:double | optional | | After the etching process, traces have a trapezoidal shape, with the top of the copper narrower than the bottom. This attribute contains the width of the top of a trace located on the design. If not present, then the value of TraceWidthBottom is used. The unit of measure is governed by StackupFile -> DefaultUnits, which is by default MIL. | | TraceWidthBot tom | xs:double | optional | | After the etching process, traces have a trapezoidal shape, with the top of the copper narrower than the bottom. This attribute contains the width of the bottom of a trace located on the design. For conductor layer types, this value is required. The unit of measure is governed by StackupFile -> DefaultUnits, which is by default MIL. | | Units_TraceWi dth | UnitsType | optional | MIL | The unit of measure used by the the TraceWidthTop and TraceWidthBottom attributes. |
StackupFile/EdaData/Stackup/Group/Layer/ SpecRef/Impedance
Defines the impedance requirements for a layer.
Parent
'StackupFile/EdaData/Stackup/Group/Layer/SpecRef' on page 391
Diagram
Occurrence
0-1
Attributes
| Name | Type | Use | Default | Description | |-------------|----------------|----------|-----------|--------------------------------------------------------------| | ImpName | xs:string | required | | The name referencing the designated Impedance | | ImpTypeName | ImpedanceTy pe | required | | The type of impedance to use within the designated Impedance |
<!-- image -->StackupFile/SupplierData
Represents instances of the manufacturing stackup, each with the required content determined by the supplier. This section should contain a full stackup defining the final materials and impedance calculation based on the material of use.
Parent
'StackupFile' on page 331
Diagram
Occurrence
0-n
Attributes
| Name | Type | Use | Default | Description | |-------------|-----------|----------|-----------|-----------------------------------------------------------------| | CompanyName | xs:string | required | | The name of the supplier of the manufacturing stackup | | ContactName | xs:string | optional | | The name of the contact of the originating stackup | | Address | xs:string | optional | | The postal address of the supplier of the manufacturing stackup | | PnoneNumber | xs:string | optional | | The phone number of the supplier of the manufacturing stackup | | Comment | xs:string | optional | | Open comment from the supplier of the manufacturing stackup |
<!-- image -->Children
- 'StackupFile/SupplierData/Specs' on page 397
- 'StackupFile/SupplierData/Stackup' on page 447
StackupFile/SupplierData/Specs
Contains a list of material specifications and impedance requirements for the stack design. Each specification is represented by an instance of the Spec element.
Parent
'StackupFile/SupplierData' on page 395
Diagram
Occurrence
1
Children
'StackupFile/SupplierData/Specs/Spec' on page 398
<!-- image -->StackupFile/SupplierData/Specs/Spec
An individual specification defining the collection of materials and impedance requirements. The Spec is selected through the use of the SpecName attribute.
Parent
'StackupFile/SupplierData/Specs' on page 397
Diagram
Occurrence
1-n
Attributes
| Name | Type | Use | Default | Description | |----------|-----------|----------|-----------|-------------------------------------| | SpecName | xs:string | required | | The name referencing the given Spec |
Children
- 'StackupFile/SupplierData/Specs/Spec/Material' on page 399
- 'StackupFile/SupplierData/Specs/Spec/Impedance' on page 411
StackupFile/SupplierData/Specs/Spec/Material
A Material specification defining a specific material, dielectric or conductor. The Material is selected through the use of the MaterialName attribute.
Parent
'StackupFile/SupplierData/Specs/Spec' on page 398
Diagram
Occurrence
0-n
Attributes
| Name | Type | Use | Default | Description | |--------------|-----------|----------|-----------|-----------------------------------------| | MaterialName | xs:string | required | | The name referencing the given Material |
Children
- 'StackupFile/SupplierData/Specs/Spec/Material/Dielectric' on page 400
- 'StackupFile/SupplierData/Specs/Spec/Material/Conductor' on page 405
- 'StackupFile/SupplierData/Specs/Spec/Material/Default_Thickness' on page 410
StackupFile/SupplierData/Specs/Spec/Material/ Dielectric
The definition of a specific piece of dielectric material.
Parent
'StackupFile/SupplierData/Specs/Spec/Material' on page 399
Diagram
Occurrence
0-1
Attributes
| Name | Type | Use | Default | Description | |--------------------|-----------------|----------|-----------|--------------------------------------------------------------------------------------| | DielectricType | DielectricTyp e | required | | Defines the generic type of dielectric materials as prepreg, core, or other | | OtherSubType | OtherType | optional | | A list of material definitions that are most often used when DielectricType is OTHER | | MaterialRefere nce | xs:string | optional | | Free text providing the material supplier's reference name |
<!-- image -->| Name | Type | Use | Default | Description | |--------------------------|-----------|----------|-----------|-------------------------------------------------------------| | GlassStyle_Co nstruction | xs:string | optional | | Free text describing the Prepreg glass or Core construction | | ResinContent_ Percent | xs:double | optional | | The percentage of resin in the dielectric material | | Description | xs:string | optional | | Open description of the dielectric material | | Comment | xs:string | optional | | Open comment on the dielectric material |
Children
'StackupFile/SupplierData/Specs/Spec/Material/Dielectric/Properties' on page 402
StackupFile/SupplierData/Specs/Spec/Material/ Dielectric/Properties
Contains a list of Frequencies related to the material behavior. Material's electrical characteristics are influenced by the frequency of the impedance net. The Frequency is selected through the use of the FrequencyName attribute.
Parent
'StackupFile/SupplierData/Specs/Spec/Material/Dielectric' on page 400
Diagram
Occurrence
0-n
Attributes
| Name | Type | Use | Default | Description | |--------------|-----------|----------|-----------|------------------------------------------| | PropertyName | xs:string | required | | The name referencing the given Frequency |
Children
'StackupFile/SupplierData/Specs/Spec/Material/Dielectric/Properties/Property' on page 403
<!-- image -->StackupFile/SupplierData/Specs/Spec/Material/ Dielectric/Properties/Property
A specific frequency and the related material characteristics.
Parent
'StackupFile/SupplierData/Specs/Spec/Material/Dielectric/Properties' on page 402
Diagram
Occurrence
1-n
Attributes
| Name | Type | Use | Default | Description | |------------------------|-----------|----------|-----------|-----------------------------------------------------------------------| | FrequencyVal | xs:double | optional | | The value of the single frequency. | | Units | UnitsType | optional | GHz | The unit of the FrequenceVal frequency. | | DielectricConst ant_Dk | xs:double | optional | | The Dielectric Constant (DK) at the specified FrequencyVal frequency. | | LossTangent_ Df | xs:double | optional | | The Loss Tangent (Df) at the specified FrequencyVal frequency. |
<!-- image -->| Name | Type | Use | Default | Description | |---------------------|-----------|----------|-----------|--------------------------------------------------------------------------------------------------------------------------------------------------------| | Thickness | xs:double | optional | | The overriding thickness of the dielectric material. The unit of measure is governed by StackupFile -> DefaultUnits, which is by default MIL. | | Finished_Thick ness | xs:double | optional | | The overriding finished thickness of the dielectric material. The unit of measure is governed by StackupFile- > DefaultUnits, which is by default MIL. | | Units_Thicknes s | UnitsType | optional | MIL | The unit of measure used by the Thickness and Finished_Thickness attributes. This unit is governed by StackupFile -> DefaultUnits. |
StackupFile/SupplierData/Specs/Spec/Material/ Conductor
The definition of a specific piece of conductive material.
Parent
'StackupFile/SupplierData/Specs/Spec/Material' on page 399
Diagram
Occurrence
0-1
Attributes
| Name | Type | Use | Default | Description | |----------------------|----------------|----------|-----------|------------------------------------------------------------------------------------------------------------------------------| | ConductorType | ConductorTyp e | required | | The type of conductor (COPPER or OTHER). | | CopperWeight _oz_ft2 | xs:double | optional | | Mainly, a historical means to specify copper thickness by using the value of the Thickness attribute located under Material. | | Description | xs:string | optional | | Open description of the conductive material. | | Comment | xs:string | optional | | Open comment on the conductive material. |
<!-- image -->Children
'StackupFile/SupplierData/Specs/Spec/Material/Conductor/Properties' on page 407
StackupFile/SupplierData/Specs/Spec/Material/ Conductor/Properties
Contains a list of Properties related to the material behavior. The Property is selected through the use of the PropertyName attribute.
Parent
'StackupFile/SupplierData/Specs/Spec/Material/Conductor' on page 405
Diagram
Occurrence
0-n
Attributes
| Name | Type | Use | Default | Description | |--------------|-----------|----------|-----------|--------------------------------------------------| | PropertyName | xs:string | required | | The name referencing the given set of Properties |
Children
'StackupFile/SupplierData/Specs/Spec/Material/Conductor/Properties/PropertyName' on page 408
<!-- image -->StackupFile/SupplierData/Specs/Spec/Material/ Conductor/Properties/PropertyName
A specific property and the related material characteristics.
Parent
'StackupFile/SupplierData/Specs/Spec/Material/Conductor/Properties' on page 407
Diagram
Occurrence
1
Attributes
| Name | Type | Use | Default | Description | |------------------------------------|-----------|----------|-----------|---------------------------------------------------------------------| | Conductivity_ mho_cm | xs:double | optional | | The Conductivity of copper measured in MHO/CM. | | SurfaceRoughn essFacingCore _Rz | xs:double | optional | | The surface roughness of copper facing the core, measured in Rz. | | SurfaceRoughn essFacingPrepr eg_Rz | xs:double | optional | | The surface roughness of copper facing the prepreg, measured in Rz. |
<!-- image -->| Name | Type | Use | Default | Description | |--------------------------|-----------|----------|-----------|-------------------------------------------------------------------------------------------------------------------------------------------------------| | SurfaceRoughn essFoil_Rz | xs:double | optional | | The surface roughness of the copper foil or sheet materials measured in Rz. | | DielectricConst ant_Dk | xs:double | optional | | The Dielectric Constant (DK) contributed to the resin during the lamination process. | | LossTangent_ Df | xs:double | optional | | The Loss Tangent (Df) contributed to the resin during the lamination process. | | Thickness | xs:double | optional | | The overriding thickness of the conductor material. The unit of measure is governed by StackupFile -> DefaultUnits, which is by default MIL. | | Finished_Thick ness | xs:double | optional | | The overriding finished thickness of the conductor material. The unit of measure is governed by StackupFile -> DefaultUnits, which is by default MIL. | | Units_Thicknes s | UnitsType | optional | ML | The unit of measure used by the Thickness and Finished_Thickness attributes. This unit is governed by StackupFile -> DefaultUnits. |
StackupFile/SupplierData/Specs/Spec/Material/ Default_Thickness
The thickness definition for the supplier-delivered dielectric or conductor material.
Parent
'StackupFile/EdaData/Specs/Spec/Material' on page 336
Diagram
Occurrence
1
Attributes
| Name | Type | Use | Default | Description | |---------------------|-----------|----------|-----------|------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Thickness | xs:double | required | | The default thickness of the dielectric or conductor material. The unit of measure is governed by StackupFile -> DefaultUnits, which is by default MIL. | | Finished_Thick ness | xs:double | optional | | The default finished thickness of the dielectric or conductor material. The unit of measure is governed by StackupFile -> DefaultUnits, which is by default MIL. | | Units | xs:double | optional | MIL | The unit value of measure used by the Thickness and Finished_Thickness attributes. This unit is governed by StackupFile -> DefaultUnits. |
<!-- image -->StackupFile/SupplierData/Specs/Spec/ Impedance
An Impedance specification defining the general impedance goal and physical characteristics. The Impedance is selected through the use of the ImplName attribute.
Parent
'StackupFile/SupplierData/Specs/Spec' on page 398
Diagram
Occurrence
0-n
Attributes
| Name | Type | Use | Default | Description | |---------|-----------|----------|-----------|-------------------------------------------| | ImpName | xs:string | required | | The name referencing the given Impedance. |
Children
- 'StackupFile/SupplierData/Specs/Spec/Impedance/Single_Ended' on page 413
- 'StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide' on page 418
- 'StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Edge_Coupled' on page 427
- 'StackupFile/SupplierData/Specs/Spec/Impedance/ Single_Ended_Coplanar_Waveguide' on page 433
- 'StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Broadside_Coupled' on page 441
StackupFile/SupplierData/Specs/Spec/ Impedance/Single_Ended
A representation of the single-ended impedance requirement.
Parent
'StackupFile/SupplierData/Specs/Spec/Impedance' on page 411
Diagram
Occurrence
0-n
Attributes
| Name | Type | Use | Default | Description | |-------------------|-----------|----------|-----------|--------------------------------------------------------------------------------------------------| | LayerName | xs:string | required | | The Layer name referencing the given Impedance Type. | | Structure | Structure | optional | | The impedance structure definition in the areas of stripline, microstrip, or Coplanar waveguide. | | ZoCalculatedO hms | xs:double | optional | | The calculated result for the given single-ended impedance instance. |
Children
- 'StackupFile/SupplierData/Specs/Spec/Impedance/Single_Ended/TraceWidth' on page 415
- 'StackupFile/SupplierData/Specs/Spec/Impedance/Single_Ended/RefPlane' on page 417
StackupFile/SupplierData/Specs/Spec/ Impedance/Single_Ended/TraceWidth
Contains the required trace width for the calculated impedance.
Parent
'StackupFile/SupplierData/Specs/Spec/Impedance/Single_Ended' on page 413
Diagram
Occurrence
1
Attributes
| Name | Type | Use | Default | Description | |-------------------|-----------|----------|-----------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | TraceWidthBot tom | xs:double | required | | After the etching process, traces have a trapezoidal shape, with the top of the copper narrower than the bottom. This attribute contains the width of the bottom of a trace located on the design. For conductor layer types, this value is required. The unit of measure is governed by StackupFile -> DefaultUnits, which is by default MIL. |
<!-- image -->| Name | Type | Use | Default | Description | |-------------------|-----------|----------|-----------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | TraceWidthTo p | xs:double | optional | | After the etching process, traces have a trapezoidal shape, with the top of the copper narrower than the bottom. This attribute contains the width of the top of a trace located on the design. If not present, then the value of TraceWidthBottom is used. The unit of measure is governed by StackupFile -> DefaultUnits, which is by default MIL. | | Units_TraceWi dth | UnitsType | optional | MIL | The unit of measure used by the TraceWidthTop and TraceWidthBottom attributes. |
StackupFile/SupplierData/Specs/Spec/ Impedance/Single_Ended/RefPlane
Contains the list of layers that represent the reference planes in impedance calculation.
Parent
'StackupFile/SupplierData/Specs/Spec/Impedance/Single_Ended' on page 413
Diagram
Occurrence
0-2
Attributes
| Name | Type | Use | Default | Description | |--------------|-----------|----------|-----------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | RefLayerName | xs:string | required | | The LayerName value of the layer found under StackupFile -> EdaData -> Stackup -> Group -> Layer. This value represents a reference plane used during the impedance calculation. |
<!-- image -->StackupFile/SupplierData/Specs/Spec/ Impedance/Differential_Coplanar_Waveguide
A representation of the differential Coplanar waveguide impedance requirement.
Parent
'StackupFile/SupplierData/Specs/Spec/Impedance' on page 411
Diagram
Occurrence
0-n
Attributes
| Name | Type | Use | Default | Description | |-----------|-----------|----------|-----------|-----------------------------------------------------| | LayerName | xs:string | required | | The Layer name referencing the given Impedance Type |
<!-- image -->| Name | Type | Use | Default | Description | |----------------------|--------------------|----------|-----------|-------------------------------------------------------------------------------------------------| | Structure | Structure | optional | | The impedance structure definition in the areas of stripline, microstrip, or Coplanar waveguide | | ZoCalculatedO hms | xs:double | optional | | The calculated result for the given single-ended impedance instance | | ZDiffCalculate dOhms | xs:double | optional | | The calculated result for the given differential impedance instance | | InsertionLoss | xs:double | optional | | The resulting loss of single power | | InsertionLossU nits | InsertionLoss Type | optional | DB/INCH | Units for InsertionLoss |
Children
- 'StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide/ TraceWidth' on page 420
- 'StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide/ Spacing' on page 422
- 'StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide/ CoplanarSpacing' on page 423
- 'StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide/ CoplanarTraceWidth' on page 424
- 'StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide/ RefPlane' on page 426
StackupFile/SupplierData/Specs/Spec/ Impedance/Differential_Coplanar_Waveguide/ TraceWidth
Contains the required trace width for the calculated impedance.
Parent
- 'StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide' on page 418
Diagram
Occurrence
1
Attributes
| Name | Type | Use | Default | Description | |-------------------|-----------|----------|-----------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | TraceWidthBot tom | xs:double | required | | After the etching process, traces have a trapezoidal shape, with the top of the copper narrower than the bottom. This attribute contains the width of the bottom of a trace located on the design. For conductor layer types, this value is required. The unit of measure is governed by StackupFile -> DefaultUnits, which is by default MIL. |
<!-- image -->| Name | Type | Use | Default | Description | |-------------------|-----------|----------|-----------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | TraceWidthTo p | xs:double | optional | | After the etching process, traces have a trapezoidal shape, with the top of the copper narrower than the bottom. This attribute contains the width of the top of a trace located on the design. If not present, then the value of TraceWidthBottom is used. The unit of measure is governed by StackupFile -> DefaultUnits, which is by default MIL. | | Units_TraceWi dth | UnitsType | optional | MIL | The unit of measure used by the TraceWidthTop and TraceWidthBottom attributes. |
StackupFile/SupplierData/Specs/Spec/ Impedance/Differential_Coplanar_Waveguide/ Spacing
Contains the required spacing between copper for the calculated impedance.
Parent
'StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide' on page 418
Diagram
Occurrence
1
Attributes
| Name | Type | Use | Default | Description | |--------|-----------|----------|-----------|------------------------------------------------| | Val | xs:double | required | | The required spacing for the related conductor | | Units | UnitsType | optional | MIL | The unit of measure used by the Val attribute |
<!-- image -->StackupFile/SupplierData/Specs/Spec/ Impedance/Differential_Coplanar_Waveguide/ CoplanarSpacing
Contains the required Coplanar spacing for the calculated impedance.
Parent
'StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide' on page 418
Diagram
Occurrence
1
Attributes
| Name | Type | Use | Default | Description | |--------|-----------|----------|-----------|---------------------------------------------------------| | Val | xs:double | required | | The required Coplanar spacing for the related conductor | | Units | UnitsType | optional | MIL | The unit of measure used by the Val attribute |
<!-- image -->StackupFile/SupplierData/Specs/Spec/ Impedance/Differential_Coplanar_Waveguide/ CoplanarTraceWidth
Contains the required trace width for the calculated impedance.
Parent
- 'StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide' on page 418
Diagram
Occurrence
0-1
Attributes
| Name | Type | Use | Default | Description | |-------------------|-----------|----------|-----------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | TraceWidthBot tom | xs:double | required | | After the etching process, traces have a trapezoidal shape, with the top of the copper narrower than the bottom. This attribute contains the width of the bottom of a trace located on the design. For conductor layer types, this value is required. The unit of measure is governed by StackupFile -> DefaultUnits, which is by default MIL. |
<!-- image -->| Name | Type | Use | Default | Description | |-------------------|-----------|----------|-----------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | TraceWidthTo p | xs:double | optional | | After the etching process, traces have a trapezoidal shape, with the top of the copper narrower than the bottom. This attribute contains the width of the top of a trace located on the design. If not present, then the value of TraceWidthBottom is used. The unit of measure is governed by StackupFile -> DefaultUnits, which is by default MIL. | | Units_TraceWi dth | UnitsType | optional | MIL | The unit of measure used by the TraceWidthTop and TraceWidthBottom attributes. |
StackupFile/SupplierData/Specs/Spec/ Impedance/Differential_Coplanar_Waveguide/ RefPlane
Contains the list of layers that represent the reference planes in impedance calculation.
Parent
'StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide' on page 418
Diagram
Occurrence
0-2
Attributes
| Name | Type | Use | Default | Description | |--------------|-----------|----------|-----------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | RefLayerName | xs:string | required | | The LayerName value of the layer found under StackupFile -> EdaData -> Stackup -> Group -> Layer. This value represents a reference plane used during the impedance calculation. |
<!-- image -->StackupFile/SupplierData/Specs/Spec/ Impedance/Differential_Edge_Coupled
A representation of the edge-coupled differential impedance requirement.
Parent
'StackupFile/SupplierData/Specs/Spec/Impedance' on page 411
Diagram
Occurrence
0-n
Attributes
| Name | Type | Use | Default | Description | |-----------|-----------|----------|-----------|-------------------------------------------------------------------------------------------------| | LayerName | xs:string | required | | The Layer name referencing the given Impedance Type | | Structure | Structure | optional | | The impedance structure definition in the areas of stripline, microstrip, or Coplanar waveguide |
<!-- image -->| Name | Type | Use | Default | Description | |----------------------|--------------------|----------|-----------|---------------------------------------------------------------------| | ZoCalculatedO hms | xs:double | optional | | The calculated result for the given single-ended impedance instance | | ZDiffCalculate dOhms | xs:double | optional | | The calculated result for the given differential impedance instance | | InsertionLoss | xs:double | optional | | The resulting loss of single power | | InsertionLossU nits | InsertionLoss Type | optional | DB/INCH | Units for InsertionLoss |
Children
- 'StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Edge_Coupled/ TraceWidth' on page 429
- 'StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Edge_Coupled/ Spacing' on page 431
- 'StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Edge_Coupled/ RefPlane' on page 432
StackupFile/SupplierData/Specs/Spec/ Impedance/Differential_Edge_Coupled/ TraceWidth
Contains the required trace width for the calculated impedance.
Parent
'StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Edge_Coupled' on page 427
Diagram
Occurrence
1
Attributes
| Name | Type | Use | Default | Description | |-------------------|-----------|----------|-----------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | TraceWidthBot tom | xs:double | required | | After the etching process, traces have a trapezoidal shape, with the top of the copper narrower than the bottom. This attribute contains the width of the bottom of a trace located on the design. For conductor layer types, this value is required. The unit of measure is governed by StackupFile -> DefaultUnits, which is by default MIL. |
<!-- image -->| Name | Type | Use | Default | Description | |-------------------|-----------|----------|-----------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | TraceWidthTo p | xs:double | optional | | After the etching process, traces have a trapezoidal shape, with the top of the copper narrower than the bottom. This attribute contains the width of the top of a trace located on the design. If not present, then the value of TraceWidthBottom is used. The unit of measure is governed by StackupFile -> DefaultUnits, which is by default MIL. | | Units_TraceWi dth | UnitsType | optional | MIL | The unit of measure used by the TraceWidthTop and TraceWidthBottom attributes. |
StackupFile/SupplierData/Specs/Spec/ Impedance/Differential_Edge_Coupled/ Spacing
Contains the required spacing between copper for the calculated impedance.
Parent
'StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Edge_Coupled' on page 427
Diagram
Occurrence
1
Attributes
| Name | Type | Use | Default | Description | |--------|-----------|----------|-----------|------------------------------------------------| | Val | xs:double | required | | The required spacing for the related conductor | | Units | UnitsType | optional | MIL | The unit of measure used by the Val attribute |
<!-- image -->StackupFile/SupplierData/Specs/Spec/ Impedance/Differential_Edge_Coupled/ RefPlane
Contains the list of layers that represent the reference planes in impedance calculation.
Parent
'StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Edge_Coupled' on page 427
Diagram
Occurrence
0-2
Attributes
| Name | Type | Use | Default | Description | |--------------|-----------|----------|-----------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | RefLayerName | xs:string | required | | The LayerName value of the layer found under StackupFile -> EdaData -> Stackup -> Group -> Layer. This value represents a reference plane used during the impedance calculation. |
<!-- image -->StackupFile/SupplierData/Specs/Spec/ Impedance/ Single_Ended_Coplanar_Waveguide
A representation of the Coplanar single-ended waveguide impedance requirement.
Parent
'StackupFile/SupplierData/Specs/Spec/Impedance' on page 411
Diagram
Occurrence
0-n
Attributes
| Name | Type | Use | Default | Description | |-----------|-----------|----------|-----------|-------------------------------------------------------------------------------------------------| | LayerName | xs:string | required | | The Layer name referencing the given Impedance Type | | Structure | Structure | optional | | The impedance structure definition in the areas of stripline, microstrip, or Coplanar waveguide |
<!-- image -->| Name | Type | Use | Default | Description | |----------------------|-----------|----------|-----------|---------------------------------------------------------------------| | ZoCalculatedO hms | xs:double | optional | | The calculated result for the given single-ended impedance instance | | ZDiffCalculate dOhms | xs:double | optional | | The calculated result for the given differential impedance instance |
Children
- 'StackupFile/SupplierData/Specs/Spec/Impedance/ Single_Ended_Coplanar_Waveguide/TraceWidth' on page 435
- 'StackupFile/SupplierData/Specs/Spec/Impedance/ Single_Ended_Coplanar_Waveguide/CoplanarSpacing' on page 437
- 'StackupFile/SupplierData/Specs/Spec/Impedance/ Single_Ended_Coplanar_Waveguide/CoplanarTraceWidth' on page 438
- 'StackupFile/SupplierData/Specs/Spec/Impedance/ Single_Ended_Coplanar_Waveguide/RefPlane' on page 440
StackupFile/SupplierData/Specs/Spec/ Impedance/ Single_Ended_Coplanar_Waveguide/ TraceWidth
Contains the required trace width for the calculated impedance.
Parent
'StackupFile/SupplierData/Specs/Spec/Impedance/Single_Ended_Coplanar_Waveguide' on page 433
Diagram
Occurrence
1
Attributes
| Name | Type | Use | Default | Description | |-------------------|-----------|----------|-----------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | TraceWidthBot tom | xs:double | required | | After the etching process, traces have a trapezoidal shape, with the top of the copper narrower than the bottom. This attribute contains the width of the bottom of a trace located on the design. For conductor layer types, this value is required. The unit of measure is governed by StackupFile -> DefaultUnits, which is by default MIL. |
<!-- image -->| Name | Type | Use | Default | Description | |-------------------|-----------|----------|-----------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | TraceWidthTo p | xs:double | optional | | After the etching process, traces have a trapezoidal shape, with the top of the copper narrower than the bottom. This attribute contains the width of the top of a trace located on the design. If not present, then the value of TraceWidthBottom is used. The unit of measure is governed by StackupFile -> DefaultUnits, which is by default MIL. | | Units_TraceWi dth | UnitsType | optional | MIL | The unit of measure used by the TraceWidthTop and TraceWidthBottom attributes. |
StackupFile/SupplierData/Specs/Spec/ Impedance/ Single_Ended_Coplanar_Waveguide/ CoplanarSpacing
Contains the required spacing between copper for the calculated impedance.
Parent
'StackupFile/SupplierData/Specs/Spec/Impedance/Single_Ended_Coplanar_Waveguide' on page 433
Diagram
Occurrence
1
Attributes
| Name | Type | Use | Default | Description | |--------|-----------|----------|-----------|---------------------------------------------------------| | Val | xs:double | required | | The required Coplanar spacing for the related conductor | | Units | UnitsType | optional | MIL | The unit of measure used by the Val attribute |
<!-- image -->StackupFile/SupplierData/Specs/Spec/ Impedance/ Single_Ended_Coplanar_Waveguide/ CoplanarTraceWidth
Contains the required coplanar trace width for the calculated impedance. When using reference planes, this element is not to be defined.
Parent
'StackupFile/SupplierData/Specs/Spec/Impedance/Single_Ended_Coplanar_Waveguide' on page 433
Diagram
Occurrence
0-1
<!-- image -->Attributes
| Name | Type | Use | Default | Description | |-------------------|-----------|----------|-----------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | TraceWidthBot tom | xs:double | required | | After the etching process, traces have a trapezoidal shape, with the top of the copper narrower than the bottom. This attribute contains the width of the bottom of a trace located on the design. For conductor layer types, this value is required. The unit of measure is governed by StackupFile -> DefaultUnits, which is by default MIL. | | TraceWidthTo p | xs:double | optional | | After the etching process, traces have a trapezoidal shape, with the top of the copper narrower than the bottom. This attribute contains the width of the top of a trace located on the design. If not present, then the value of TraceWidthBottom is used. The unit of measure is governed by StackupFile -> DefaultUnits, which is by default MIL. | | Units_TraceWi dth | UnitsType | optional | MIL | The unit of measure used by the TraceWidthTop and TraceWidthBottom attributes. |
StackupFile/SupplierData/Specs/Spec/ Impedance/ Single_Ended_Coplanar_Waveguide/RefPlane
Contains the list of layers that represent the reference planes in impedance calculation.
Parent
'StackupFile/SupplierData/Specs/Spec/Impedance/Single_Ended_Coplanar_Waveguide' on page 433
Diagram
Occurrence
0-2
Attributes
| Name | Type | Use | Default | Description | |--------------|-----------|----------|-----------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | RefLayerName | xs:string | required | | The LayerName value of the layer found under StackupFile -> EdaData -> Stackup -> Group -> Layer. This value represents a reference plane used during the impedance calculation. |
<!-- image -->StackupFile/SupplierData/Specs/Spec/ Impedance/Differential_Broadside_Coupled
A representation of the broadside-coupled differential impedance requirement.
Parent
'StackupFile/SupplierData/Specs/Spec/Impedance' on page 411
Diagram
Occurrence
0-n
Attributes
| Name | Type | Use | Default | Description | |-----------|-----------|----------|-----------|-------------------------------------------------------------------------------------------------| | LayerName | xs:string | required | | The Layer name referencing the given Impedance Type | | Structure | Structure | optional | | The impedance structure definition in the areas of stripline, microstrip, or Coplanar waveguide |
<!-- image -->| Name | Type | Use | Default | Description | |----------------------|--------------------|----------|-----------|----------------------------------------------------------------| | ZoCalculatedO hm | xs:double | optional | | The calculated result for this single-ended impedance instance | | ZDiffCalculate dOhms | xs:double | optional | | The calculated result for this differential impedance instance | | InsertionLoss | xs:double | optional | | The resulting loss of single power | | InsertionLossU nits | InsertionLoss Type | optional | DB/INCH | Units for InsertionLoss |
Children
- 'StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Broadside_Coupled/ TraceWidth' on page 443
- 'StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Broadside_Coupled/ TraceSeparation' on page 445
- 'StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Broadside_Coupled/ RefPlane' on page 446
StackupFile/SupplierData/Specs/Spec/ Impedance/Differential_Broadside_Coupled/ TraceWidth
Contains the required trace width for the calculated impedance.
Parent
'StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Broadside_Coupled' on page 441
Diagram
Occurrence
1
Attributes
| Name | Type | Use | Default | Description | |-------------------|-----------|----------|-----------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | TraceWidthBot tom | xs:double | required | | After the etching process, traces have a trapezoidal shape, with the top of the copper narrower than the bottom. This attribute contains the width of the bottom of a trace located on the design. For conductor layer types, this value is required. The unit of measure is governed by StackupFile -> DefaultUnits, which is by default MIL. |
<!-- image -->| Name | Type | Use | Default | Description | |-------------------|-----------|----------|-----------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | TraceWidthTo p | xs:double | optional | | After the etching process, traces have a trapezoidal shape, with the top of the copper narrower than the bottom. This attribute contains the width of the top of a trace located on the design. If not present, then the value of TraceWidthBottom is used. The unit of measure is governed by StackupFile -> DefaultUnits, which is by default MIL. | | Units_TraceWi dth | UnitsType | optional | MIL | The unit of measure used by the TraceWidthTop and TraceWidthBottom attributes. |
StackupFile/SupplierData/Specs/Spec/ Impedance/Differential_Broadside_Coupled/ TraceSeparation
Contains the required distance between the related conductors.
Parent
- 'StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Broadside_Coupled' on page 441
Diagram
Occurrence
1
Attributes
| Name | Type | Use | Default | Description | |---------|------------|----------|-----------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Val | xs:double | required | | The required copper separation value for the related conductors | | Units | UnitsType | optional | MIL | The unit of measure used by the Val attribute | | IsPitch | xs:boolean | optional | true | Trace Separation definition: true -the spacing between the conductors is measured from center line to center line, or pitch false -the spacing between the conductors is measured from edge to edge |
<!-- image -->StackupFile/SupplierData/Specs/Spec/ Impedance/Differential_Broadside_Coupled/ RefPlane
Contains the list of layers that represent the reference planes in impedance calculation.
Parent
'StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Broadside_Coupled' on page 441
Diagram
Occurrence
0-2
Attributes
| Name | Type | Use | Default | Description | |--------------|-----------|----------|-----------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | RefLayerName | xs:string | required | | The LayerName value of the layer found under StackupFile -> EdaData -> Stackup -> Group -> Layer. This value represents a reference plane used during the impedance calculation. |
<!-- image -->StackupFile/SupplierData/Stackup
Contains the manufacturing stackup representation determined by the supplier.
Parent
'StackupFile/SupplierData' on page 395
Diagram
Occurrence
1
Attributes
| Name | Type | Use | Default | Description | |-------------------|---------------|----------|------------|-----------------------------------------| | StackupName | xs:string | required | | The name referencing the given Stackup. | | StackupThickn ess | xs:double | required | | The calculated board thickness. | | Status | StackupStatus | optional | SUBMITT ED | The stackup status. |
<!-- image -->| Name | Type | Use | Default | Description | |------------------------|----------------|----------|-----------|-------------------------------------------------------------------------------------------------------------------------------------------| | Units | UnitsType | optional | MIL | The unit of measure used by the StackupThickness, PlusTol, and MinusTol attributes. This unit is governed by StackupFile -> DefaultUnits. | | WhereMeasure d | WhereMeasur ed | optional | METAL | An enumerated value indicating where to measure the StackupThickness value. | | TotalLaminatio nCycles | xs:integer | optional | | The total number of lamination cycles required to complete the booking process. |
Children
'StackupFile/SupplierData/Stackup/Group' on page 449
StackupFile/SupplierData/Stackup/Group
A stackup is created from Groups. A Group is a collection of Materials in which conductor materials are tied to copper layers of the design. Each series is represented from the top of the stack to the bottom.
Parent
'StackupFile/SupplierData/Stackup' on page 447
Diagram
Occurrence
1-n
Attributes
| Name | Type | Use | Default | Description | |-------------------------|------------|----------|-----------|-------------------------------------------------------------------------------------------------------------------------| | GroupName | xs:string | required | | The name referencing the given Group. | | GroupThicknes s | xs:double | optional | | The total thickness for the group of layers, in units defined in the Units attribute. | | Units | UnitsType | optional | MIL | The unit of measure used by the GroupThickness attribute. This unit is governed by StackupFile -> DefaultUnits. | | NumberOfLam inateCycles | xs:integer | optional | | The total number of lamination cycles to subject the layer group, from the beginning to the end of the booking process. |
<!-- image -->Children
'StackupFile/SupplierData/Stackup/Group/Layer' on page 451
February 2020
StackupFile/SupplierData/Stackup/Group/ Layer
A layer definition within the Group.
Parent
'StackupFile/SupplierData/Stackup/Group' on page 449
Diagram
Occurrence
1-n
Attributes
| Name | Type | Use | Default | Description | |-----------|-----------|----------|-----------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | LayerName | xs:string | required | | The name of the layer, in most cases, found in the section EdaData -> Stackup -> Group -> Layer. If the following Layer attributes are missing, they are taken from that reference. Otherwise, they may need to be added. |
<!-- image -->| Name | Type | Use | Default | Description | |---------------------|---------------|----------|-----------|---------------------------------------------------------------------------------------------------------------------------------------------------| | LayerType | LayerType | optional | DOCUME NT | An enumerated list of layer types representing the purpose of the layer. | | LayerSubType | LayerSubTyp e | optional | | An enumerated list of layer subtypes that refine the LayerType value. For example, a LayerType DRILL with a SubType BACKDRILL. | | MechStartLaye rName | xs:string | optional | | If LayerType has the value of DRILL or ROUT, this attribute contains the name of the initial layer where the material is mechanically penetrated. | | MechEndLayer Name | xs:string | optional | | If LayerType has the value of DRILL or ROUT, this attribute contains the name of the final layer where the material is mechanically penetrated. | | Side | SideType | optional | NONE | An enumerated list of a values declaring the relative position of the layer within the stackup. | | Description | xs:string | optional | | Open description from the design company of the originating layer. | | Comment | xs:string | optional | | Open comment from the design company of the originating layer. |
Children
'StackupFile/EdaData/Stackup/Group/Layer/SpecRef' on page 391
StackupFile/SupplierData/Stackup/Group/ Layer/SpecRef
The list of Material and Impedance Specs, and conductor requirements for a layer.
Parent
'StackupFile/SupplierData/Stackup/Group/Layer' on page 451
Diagram
Occurrence
0-n
Attributes
| Name | Type | Use | Default | Description | |-------------------|-----------|----------|-----------|--------------------------------------------------| | MaterialSpecN ame | xs:string | required | | The name referencing the selected Material Spec | | ImpSpecName | xs:string | optional | | The name referencing the selected Impedance Spec |
Children
'StackupFile/SupplierData/Stackup/Group/Layer/SpecRef/Material' on page 454
<!-- image -->StackupFile/SupplierData/Stackup/Group/ Layer/SpecRef/Material
Defines the Material requirements for a layer.
Parent
'StackupFile/SupplierData/Stackup/Group/Layer/SpecRef' on page 453
Diagram
Occurrence
0-1
Attributes
| Name | Type | Use | Default | Description | |--------------|-----------|----------|-----------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | MaterialName | xs:string | required | | The name referencing the designated Material within the referenced SpecName. | | PropertyName | xs:string | optional | | The name referencing the designated Properties within the referenced Material. If only one Property is defined, then this Property is considered the default, and the existence of the attribute FrequencyVal is not required. |
<!-- image -->| Name | Type | Use | Default | Description | |--------------------|-----------|----------|-----------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | FrequencyVal | xs:double | optional | | The frequency of the signal on the net. This attribute can reference additional material content when referenced into FrequencyName. If only one Frequency is defined, then it is considered the default, and the existence of this attribute is not required. | | CopperAreaPre cent | xs:double | optional | | Percentage calculated by dividing the copper area of the layer by the total area of the layer laminate. |
Stackup Schema File
This is the full schema file.
<?xml version="1.0" encoding="Windows-1252"?> <!-- edited with XMLSpy v2020 sp1 (x64) (http://www.altova.com) by Nina Kaluta (Mentor Graphics) --> <xs:schema xmlns:vc="http://www.w3.org/2007/XMLSchema-versioning" xmlns:xs="http://www.w3.org/2001/XMLSchema" elementFormDefault="qualified" attributeFormDefault="unqualified" vc:minVersion="1.1"> <xs:simpleType name="Polarity"> <xs:restriction base="xs:string"> <xs:enumeration value="POSITIVE"/> <xs:enumeration value="NEGATIVE"/> </xs:restriction> </xs:simpleType> <xs:simpleType name="LayerType"> <xs:restriction base="xs:string"> <xs:enumeration value="SIGNAL"/> <xs:enumeration value="POWER_GROUND"/> <xs:enumeration value="MIXED"/> <xs:enumeration value="SOLDER_MASK"/> <xs:enumeration value="SILK_SCREEN"/> <xs:enumeration value="SOLDER_PASTE"/> <xs:enumeration value="DRILL"/> <xs:enumeration value="ROUT"/> <xs:enumeration value="DOCUMENT"/> <xs:enumeration value="MASK"/> <xs:enumeration value="DIELECTRIC"/> <xs:enumeration value="CONDUCTIVE_PASTE"/> <xs:enumeration value="COMPONENT"/> <xs:enumeration value="POWER"/> <xs:enumeration value="GROUND"/> </xs:restriction> </xs:simpleType> <xs:simpleType name="LayerSubType"> <xs:restriction base="xs:string"> <xs:enumeration value="PUNCH"/> <xs:enumeration value="BACKDRILL"/> <xs:enumeration value="DUAL_DIAMETER"/> <xs:enumeration value="EMBEDDED_R"/> <xs:enumeration value="EMBEDDED_C"/> <xs:enumeration value="COVERLAY"/> <xs:enumeration value="COVERCOAT"/> <xs:enumeration value="STIFFENER"/> <xs:enumeration value="BEND_AREA"/> <xs:enumeration value="PSA"/> <xs:enumeration value="MIXED_FLEX"/> <xs:enumeration value="PG_FLEX"/> <xs:enumeration value="SIGNAL_FLEX"/> <xs:enumeration value="AREA"/> <xs:enumeration value="DRAWING"/> <xs:enumeration value="SILVER_MASK"/> <xs:enumeration value="OSP_MASK"/> <xs:enumeration value="IMMERSION_MASK"/> <xs:enumeration value="PLATING_MASK"/> <xs:enumeration value="CARBON_MASK"/> <xs:enumeration value="CORE"/> <xs:enumeration value="PREPREG"/> <xs:enumeration value="WIRE_BONDING"/> <xs:enumeration value="FLEX_AREA"/>
<xs:enumeration value="RIGID_AREA"/> </xs:restriction> </xs:simpleType> <xs:simpleType name="Context"> <xs:restriction base="xs:string"> <xs:enumeration value="BOARD"/> <xs:enumeration value="MISC"/> </xs:restriction> </xs:simpleType> <xs:simpleType name="SideType"> <xs:restriction base="xs:string"> <xs:enumeration value="NONE"/> <xs:enumeration value="TOP"/> <xs:enumeration value="BOTTOM"/> <xs:enumeration value="INNER"/> </xs:restriction> </xs:simpleType> <xs:simpleType name="UnitsType"> <xs:restriction base="xs:string"> <xs:enumeration value="MM"/> <xs:enumeration value="MICRON"/> <xs:enumeration value="INCH"/> <xs:enumeration value="MIL"/> </xs:restriction> </xs:simpleType> <xs:simpleType name="WhereMeasured"> <xs:restriction base="xs:string"> <xs:enumeration value="LAMINATE"/> <xs:enumeration value="METAL"/> <xs:enumeration value="MASK"/> <xs:enumeration value="OTHER"/> </xs:restriction> </xs:simpleType> <xs:simpleType name="Structure"> <xs:restriction base="xs:string"> <xs:enumeration value="STRIPLINE"/> <xs:enumeration value="PLANE_LESS_STRIPLINE"/> <xs:enumeration value="MICROSTRIP_EMBEDDED"/> <xs:enumeration value="MICROSTRIP_NO_MASK"/> <xs:enumeration value="MICROSTRIP_MASK_COVERED"/> <xs:enumeration value="COPLANAR_WAVEGUIDED_STRIPLINE"/> <xs:enumeration value="COPLANAR_WAVEGUIDED_NO_MASK"/> <xs:enumeration value="COPLANAR_WAVEGUIDED_MASK_COVERED"/> </xs:restriction> </xs:simpleType> <xs:simpleType name="DielecticType"> <xs:restriction base="xs:string"> <xs:enumeration value="PREPREG"/> <xs:enumeration value="CORE"/> <xs:enumeration value="OTHER"/> <xs:enumeration value="UNDEFINED"/> </xs:restriction> </xs:simpleType> <xs:simpleType name="ConductorType"> <xs:restriction base="xs:string"> <xs:enumeration value="COPPER"/> <xs:enumeration value="OTHER"/> </xs:restriction>
</xs:simpleType> <xs:simpleType name="FrequencyType"> <xs:restriction base="xs:string"> <xs:enumeration value="Hz"/> <xs:enumeration value="MHz"/> <xs:enumeration value="GHz"/> </xs:restriction> </xs:simpleType> <xs:simpleType name="OtherType"> <xs:restriction base="xs:string"> <xs:enumeration value="COVERLAY"/> <xs:enumeration value="COVERCOAT"/> <xs:enumeration value="STIFFENER"/> <xs:enumeration value="PRESSURE_SENSITIVE_ADHESIVE"/> <xs:enumeration value="OSP_MASK"/> <xs:enumeration value="SILVER_MASK"/> <xs:enumeration value="CARBON_MASK"/> <xs:enumeration value="SOLDER_MASK"/> <xs:enumeration value="PLATING_MASK"/> <xs:enumeration value="IMMERSION_MASK"/> <xs:enumeration value="OTHER"/> </xs:restriction> </xs:simpleType> <xs:simpleType name="ImpedanceType"> <xs:restriction base="xs:string"> <xs:enumeration value="SINGLE_ENDED"/> <xs:enumeration value="DIFFERENTIAL_COPLANAR_WAVEGUIDED"/> <xs:enumeration value="DIFFERENTIAL_EDGE_COUPLE"/> <xs:enumeration value="SINGLE_ENDED_COPLANAR_WAVEGUIDED"/> <xs:enumeration value="DIFFERENTIAL_BROADSIDE_COUPLED"/> </xs:restriction> </xs:simpleType> <xs:simpleType name="InsertionLossType"> <xs:restriction base="xs:string"> <xs:enumeration value="DB/INCH"/> <xs:enumeration value="DB/CM"/> <xs:enumeration value="DB/M"/> </xs:restriction> </xs:simpleType> <xs:simpleType name="StackupStatus"> <xs:restriction base="xs:string"> <xs:enumeration value="SELECTED"/> <xs:enumeration value="VALID"/> <xs:enumeration value="INVALID"/> <xs:enumeration value="SUBMITTED"/> <xs:enumeration value="UNDER REVIEW"/> </xs:restriction> </xs:simpleType> <xs:element name="StackupFile"> <xs:annotation> <xs:documentation>The base of ODB++ stackup content that contains material, impedance and a design based stackup requirement followed by any number of stackup suppler solutions.</xs:documentation> </xs:annotation> <xs:complexType> <xs:sequence> <xs:element name="EdaData" minOccurs="0" maxOccurs="1"> <xs:annotation>
<xs:documentation>Contains the all the stackup required content as delivered by the design source. It maybe be very generic containing basic material requirements as well as impedance defintion or it may contain a full stackup based on the design source having a stackup software solution to use. In either case, this is the basis for all stackup definitions to
begin from and should not be altered in any way by other stackup suppliers.</xs:documentation> </xs:annotation> <xs:complexType> <xs:sequence> <xs:element name="Specs"> <xs:annotation> <xs:documentation>Contains a list of specification (Spec) of material used during stack design and impedance requirements.</ xs:documentation> </xs:annotation> <xs:complexType> <xs:sequence> <xs:element name="Spec" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>An indiviual Spec defining a collection of materials and impedance requirements. The Spec is select later through the use of the SpecName attribute.</xs:documentation> </xs:annotation> <xs:complexType> <xs:sequence> <xs:element name="Material" minOccurs="0" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>A Material specficiation defining a specific material, dielectric or conductor. The Material is select later through the use of the MaterialName attribute.</xs:documentation> </xs:annotation> <xs:complexType> <xs:sequence> <xs:element name="Dielectric" minOccurs="0"> <xs:annotation> <xs:documentation>A definition of a specific piece of dielectric material. </xs:documentation> </xs:annotation> <xs:complexType> <xs:sequence> <xs:element name="Properties" minOccurs="0" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Contains a list of Properties related to the material behavior. Material's electrical characteristics are influenced by the frequeny of the impedance net.The Property is selected later through the use of the PropertyName attrbute.</xs:documentation> </xs:annotation> <xs:complexType> <xs:sequence> <xs:element name="Property" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>A specific property and the related material characteristics.</xs:documentation> </xs:annotation> <xs:complexType>
<xs:attribute name="FrequencyVal" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The value of the single frequency. Default is GHz.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units" type="FrequencyType" use="optional" default="GHz"> <xs:annotation> <xs:documentation>The unit of the FrequenceVal frequency.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="DielectricConstant_Dk" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The Dielectric Constant (DK) at the specified FrequencyVal frequency.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="LossTangent_Df" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The Loss Tangent (Df) at the specified FrequencyVal frequency.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Thickness" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The overriding thickness of the dielectric material. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Finished_Thickness" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The overriding thickness of the dielectric material. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units_Thickness" type="UnitsType" use="optional" default="MIL"> <xs:annotation> <xs:documentation>The unit value that the Thickness and Finished_Thickness attribute is to be measured in. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence> <xs:attribute name="PropertyName" type="xs:string" use="required">
<xs:annotation> <xs:documentation>The name used to reference the specific set of Properties.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence> <xs:attribute name="DielectricType" type="DielecticType" use="required"> <xs:annotation> <xs:documentation>Defines the generic type of dielelectric materials, prepreg or core or other.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="OtherSubType" type="OtherType" use="optional"> <xs:annotation> <xs:documentation>A list of material definition that will most often be used when the DielectricType is OTHER.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="MaterialReference" type="xs:string" use="optional"> <xs:annotation> <xs:documentation>A free string of text that provides the material suppliers reference name.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="GlassStyle_Construction" type="xs:string" use="optional"> <xs:annotation> <xs:documentation>A free string of text that description the Prepreg glass or Core construction.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="ResinContent_Percent" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The percentage of resin found in the dielectric material.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Description" type="xs:string" use="optional"> <xs:annotation> <xs:documentation>Open description regarding the dielectric material.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Comment" type="xs:string" use="optional"> <xs:annotation> <xs:documentation>Open commnent regarding the dielectric material.</xs:documentation> </xs:annotation> </xs:attribute>
</xs:complexType> </xs:element> <xs:element name="Conductor" minOccurs="0"> <xs:annotation> <xs:documentation>A definition of a specific piece of conductive material. </xs:documentation> </xs:annotation> <xs:complexType> <xs:sequence> <xs:element name="Properties" minOccurs="0" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Contains a list of Properties related to the material behavior. The Property is selected later through the use of the PropertyName attrbute.</xs:documentation> </xs:annotation> <xs:complexType> <xs:sequence> <xs:element name="Property"> <xs:annotation> <xs:documentation>A specific property and the related material characteristics.</xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="Conductivity_mho_cm" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The Conductivity of the copper measured in MHO/CM.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="SurfaceRoughnessFacingCore_Rz" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>In core materials the surface roughness of the copper facing the core measured in Rz.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="SurfaceRoughnessFacingPrepreg_Rz" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>In core materials the surface roughness of the copper facing the prepreg measured in Rz.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="SurfaceRoughnessFoil_Rz" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>For copper foil or sheet materials the surface roughness measured in Rz.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="DielectricConstant_Dk" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The Dielectric Constant (DK) contributed to the resin during the lamination process.</xs:documentation>
</xs:annotation> </xs:attribute> <xs:attribute name="LossTangent_Df" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The Loss Tangent (Df) at the scontributed to the resin during the lamination process.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Thickness" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The overrideing thickness of the conductor material. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Finished_Thickness" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The overiding finished thickness of the conductor material. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units_Thickness" type="UnitsType" use="optional" default="MIL"> <xs:annotation> <xs:documentation>The unit value that the Thickness and Finished_Thickness attribute is to be measured in. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence> <xs:attribute name="PropertyName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The name used to reference the specific set of Properties.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence> <xs:attribute name="ConductorType" type="ConductorType" use="required"> <xs:annotation> <xs:documentation>The type of conductor. The values are COPPER or OTHER.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="CopperWeight_oz_ft2" type="xs:double" use="optional">
<xs:annotation>
<xs:documentation>This is mainly a historical means to specify copper thickness. The intended value to be used in this case is Thickness located just under Material.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Description" type="xs:string" use="optional"> <xs:annotation> <xs:documentation>Open description regarding the conductive material.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Comment" type="xs:string" use="optional"> <xs:annotation> <xs:documentation>Open commnent regarding the conductive material.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="Default_Thickness"> <xs:annotation> <xs:documentation>A definition of the dielectric or conductor material supplier delievered thickness.</xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="Thickness" type="xs:double" use="required"> <xs:annotation> <xs:documentation>The default thickness of the dielectric or conductor material. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Finished_Thickness" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The default finished thickness of the dielectric or conductor material. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units" type="UnitsType" default="MIL"> <xs:annotation> <xs:documentation>The unit value that the Thickness and Finished_Thickness attribute is to be measured in. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence> <xs:attribute name="MaterialName" type="xs:string" use="required"> <xs:annotation>
<xs:documentation>The name used to reference the specific Material.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="Impedance" minOccurs="0" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>A Impedance specficiation defining the general impedance goal and then the phyical characteristics. The Impedance is select later through the use of the ImplName attribute.</ xs:documentation> </xs:annotation> <xs:complexType mixed="true"> <xs:sequence> <xs:element name="Single_Ended" minOccurs="0" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>A representation of a single-ended impedance requirement.</xs:documentation> </xs:annotation> <xs:complexType> <xs:sequence> <xs:element name="TraceWidth"> <xs:annotation> <xs:documentation>Contains the desired trace width to use for the target impedance.</xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="Val" type="xs:double" use="required"> <xs:annotation> <xs:documentation>Contains the target trace width of the related conductor. Default units is MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units" type="UnitsType" use="optional" default="MIL"> <xs:annotation> <xs:documentation>Contains the unit of measure used for by the value in Val.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="PlusVal" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>A positive value representing the plus tolerance value to added to the target trace (Val) with value.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="MinusVal" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>A positive value representing the negative tolerance value to substracted from the target trace (Val) with value.</xs:documentation>
</xs:annotation> </xs:attribute> <xs:attribute name="TolPercent" type="xs:boolean" use="optional" default="false"> <xs:annotation> <xs:documentation>Trace width tolerance definitiion - if true a percentage of Val, if false an absolute a value, to add or substracted fromVal.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="RefPlane" minOccurs="0" maxOccurs="2"> <xs:annotation> <xs:documentation>Contains the list of layer that represent the refence planes used during the impedance calculation.</ xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="RefLayerName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The LayerName value of the layer found under StackupFile.EdaData.Stackup.Group.Layer that represent a refeence plan used during the impedance calculation.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence> <xs:attribute name="LayerName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The Layer name used to reference the specific Impedance Type.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Structure" type="Structure" use="optional"> <xs:annotation> <xs:documentation>Contains the impedance structure definition in the area of stripline, microstrip or coplanar waveguided.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="ZoCalculatedOhms" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>If the design source has an impedance similator this would contain the calculated single-ended calculation result for this impedance instance.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="Differential_Coplanar_Waveguide" minOccurs="0" maxOccurs="unbounded"> <xs:annotation>
<xs:documentation>A representation of a differential Coplanar waveguided impedance requirement.</xs:documentation> </xs:annotation> <xs:complexType> <xs:sequence> <xs:element name="TraceWidth"> <xs:annotation> <xs:documentation>Contains the desired trace width to use for the target impedance.</xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="Val" type="xs:double" use="required"> <xs:annotation> <xs:documentation>Contains the target trace width of the related conductor.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units" type="UnitsType" use="optional" default="MIL"> <xs:annotation> <xs:documentation>Contains the unit of measure used for by the value in Val.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="PlusVal" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>A positive value representing the plus tolerance value to added to the target trace (Val) with value.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="MinusVal" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>A positive value representing the negative tolerance value to substracted from the target trace (Val) with value.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="TolPercent" type="xs:boolean" use="optional" default="false"> <xs:annotation> <xs:documentation>Trace width tolerance definitiion - if true a percentage of Val, if false an absolute a value, to add or substracted fromVal.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="Spacing"> <xs:annotation> <xs:documentation>Contains the desired spacing between copper for the target impedance.</xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="Val" type="xs:double"
use="required"> <xs:annotation> <xs:documentation>Contains the target spacing for the related conductor. Default units is MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units" type="UnitsType" use="optional" default="MIL"> <xs:annotation> <xs:documentation>Contains the unit of measure used for by the value in Val.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="CoplanarSpacing"> <xs:annotation> <xs:documentation>Contains the coplanar desired spacing to use for the target impedance.</xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="Val" type="xs:double" use="required"> <xs:annotation> <xs:documentation>Contains the target coplanar spacing of the related conductor. Default units is MIL.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units" type="UnitsType" use="optional" default="MIL"> <xs:annotation> <xs:documentation>Contains the unit of measure used for by the value in Val.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="CoplanarTraceWidth" minOccurs="0"> <xs:annotation> <xs:documentation>Contains the coplanar desired trace width to use for the target impedance. In the case of reference a plane this attribute is to not be defined.</xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="Val" type="xs:double" use="required"> <xs:annotation> <xs:documentation>Contains the target trace width of the related conductor. Default units is MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units" type="UnitsType" use="optional" default="MIL"> <xs:annotation> <xs:documentation>Contains the unit of measure used for by the value in Val.</xs:documentation> </xs:annotation>
</xs:attribute> <xs:attribute name="PlusVal" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>A positive value representing the plus tolerance value to added to the target trace (Val) with value.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="MinusVal" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>A positive value representing the negative tolerance value to substracted from the target trace (Val) with value.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="TolPercent" type="xs:boolean" use="optional" default="false"> <xs:annotation> <xs:documentation>Trace width tolerance definitiion - if true a percentage of Val, if false an absolute a value, to add or substracted fromVal.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="RefPlane" minOccurs="0" maxOccurs="2"> <xs:annotation> <xs:documentation>Contains the list of layer that represent the refence planes used during the impedance calculation.</ xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="RefLayerName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The LayerName value of the layer found under StackupFile.EdaData.Stackup.Group.Layer that represent a refeence plan used during the impedance calculation.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence> <xs:attribute name="LayerName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The Layer name used to reference the specific Impedance Type.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Structure" type="Structure" use="optional"> <xs:annotation> <xs:documentation>Contains the impedance structure definition in the area of stripline, microstrip or coplanar waveguided.</ xs:documentation>
</xs:annotation> </xs:attribute> <xs:attribute name="ZoCalculatedOhms" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>If the design source has an impedance similator this would contain the calculated single-ended calculation result for this impedance instance.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="ZDiffCalculatedOhms" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>If the design source has an impedance similator this would contain the calculated differential calculation result for this impedance instance.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="InsertionLoss" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The resulting lost of single power.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="InsertionLossUnits" type="InsertionLossType" use="optional" default="DB/INCH"> <xs:annotation> <xs:documentation>Units for InsertionLoss. Default is dB/Inch.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="Differential_Edge_Coupled" minOccurs="0" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>A representation of a differential edge coupled impedance requirement.</xs:documentation> </xs:annotation> <xs:complexType> <xs:sequence> <xs:element name="TraceWidth"> <xs:annotation> <xs:documentation>Contains the desired trace width to use for the target impedance.</xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="Val" type="xs:double" use="required"> <xs:annotation> <xs:documentation>Contains the target trace width of the related conductor.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units" type="UnitsType" use="optional" default="MIL"> <xs:annotation>
<xs:documentation>Contains the unit of measure used for by the value in Val.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="PlusVal" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>A positive value representing the plus tolerance value to added to the target trace (Val) with value.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="MinusVal" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>A positive value representing the negative tolerance value to substracted from the target trace (Val) with value.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="TolPercent" type="xs:boolean" use="optional" default="false"> <xs:annotation> <xs:documentation>Trace width tolerance definitiion - if true a percentage of Val, if false an absolute a value, to add or substracted fromVal.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="Spacing"> <xs:annotation> <xs:documentation>Contains the desired spacing between copper for the target impedance.</xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="Val" type="xs:double" use="required"> <xs:annotation> <xs:documentation>Contains the target spacing for the related conductor.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units" type="UnitsType" use="optional" default="MIL"> <xs:annotation> <xs:documentation>Contains the unit of measure used for by the value in Val.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="RefPlane" minOccurs="0" maxOccurs="2"> <xs:annotation> <xs:documentation>Contains the list of layer that represent the refence planes used during the impedance calculation.</ xs:documentation>
</xs:annotation>
<xs:complexType> <xs:attribute name="RefLayerName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The LayerName value of the layer found under StackupFile.EdaData.Stackup.Group.Layer that represent a refeence plan used during the impedance calculation.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence> <xs:attribute name="LayerName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The Layer name used to reference the specific Impedance Type.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Structure" type="Structure" use="optional"> <xs:annotation> <xs:documentation>Contains the impedance structure definition in the area of stripline, microstrip or coplanar waveguided.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="ZoCalculatedOhms" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>If the design source has an impedance similator this would contain the calculated single-ended calculation result for this impedance instance.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="ZDiffCalculatedOhms" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>If the design source has an impedance similator this would contain the calculated differential calculation result for this impedance instance.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="InsertionLoss" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The resulting lost of single power.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="InsertionLossUnits" type="InsertionLossType" use="optional" default="DB/INCH"> <xs:annotation> <xs:documentation>Units for InsertionLoss. Default is dB/Inch.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType>
</xs:element> <xs:element name="Single_Ended_Coplanar_Waveguide" minOccurs="0" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>A representation of a single-ended Coplanar waveguided impedance requirement.</xs:documentation> </xs:annotation> <xs:complexType> <xs:sequence> <xs:element name="TraceWidth"> <xs:annotation> <xs:documentation>Contains the desired trace width to use for the target impedance.</xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="Val" type="xs:double" use="required"> <xs:annotation> <xs:documentation>Contains the target trace width of the related conductor.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units" type="UnitsType" use="optional" default="MIL"> <xs:annotation> <xs:documentation>Contains the unit of measure used for by the value in Val.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="PlusVal" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>A positive value representing the plus tolerance value to added to the target trace (Val) with value.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="MinusVal" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>A positive value representing the negative tolerance value to substracted from the target trace (Val) with value.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="TolPercent" type="xs:boolean" use="optional" default="false"> <xs:annotation> <xs:documentation>Trace width tolerance definitiion - if true a percentage of Val, if false an absolute a value, to add or substracted fromVal.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="CoplanarSpacing"> <xs:annotation> <xs:documentation>Contains the desired spacing between
copper for the target impedance.</xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="Val" type="xs:double" use="required"> <xs:annotation> <xs:documentation>Contains the target spacing for the related conductor.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units" type="UnitsType" use="optional" default="MIL"> <xs:annotation> <xs:documentation>Contains the unit of measure used for by the value in Val.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="CoplanarTraceWidth" minOccurs="0"> <xs:annotation> <xs:documentation>Contains the coplanar desired trace width to use for the target impedance. In the case of reference a plane this attribute is to not be defined.</xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="Val" type="xs:double" use="required"> <xs:annotation> <xs:documentation>Contains the target trace width of the related conductor.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units" type="UnitsType" use="optional" default="MIL"> <xs:annotation> <xs:documentation>Contains the unit of measure used for by the value in Val.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="PlusVal" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>A positive value representing the plus tolerance value to added to the target trace (Val) with value.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="MinusVal" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>A positive value representing the negative tolerance value to substracted from the target trace (Val) with value.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="TolPercent" type="xs:boolean" use="optional" default="false">
<xs:annotation> <xs:documentation>Trace width tolerance definitiion - if true a percentage of Val, if false an absolute a value, to add or substracted fromVal.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="RefPlane" minOccurs="0" maxOccurs="2"> <xs:annotation> <xs:documentation>Contains the list of layer that represent the refence planes used during the impedance calculation.</ xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="RefLayerName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The LayerName value of the layer found under StackupFile.EdaData.Stackup.Group.Layer that represent a refeence plan used during the impedance calculation.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence> <xs:attribute name="LayerName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The Layer name used to reference the specific Impedance Type.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Structure" type="Structure" use="optional"> <xs:annotation> <xs:documentation>Contains the impedance structure definition in the area of stripline, microstrip or coplanar waveguided.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="ZoCalculatedOhms" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>If the design source has an impedance similator this would contain the calculated single-ended calculation result for this impedance instance.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="ZDiffCalculatedOhms" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>If the design source has an impedance similator this would contain the calculated differential calculation result for this impedance instance.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType>
</xs:element> <xs:element name="Differential_Broadside_Coupled" minOccurs="0" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>A representation of a differential broadshide coupled impedance requirement.</xs:documentation> </xs:annotation> <xs:complexType> <xs:sequence> <xs:element name="TraceWidth"> <xs:annotation> <xs:documentation>Contains the desired trace width to use for the target impedance.</xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="Val" type="xs:double" use="required"> <xs:annotation> <xs:documentation>Contains the target trace width of the related conductor.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units" type="UnitsType" use="optional" default="MIL"> <xs:annotation> <xs:documentation>Contains the unit of measure used for by the value in Val.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="PlusVal" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>A positive value representing the plus tolerance value to added to the target trace (Val) with value.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="MinusVal" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>A positive value representing the negative tolerance value to substracted from the target trace (Val) with value.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="TolPercent" type="xs:boolean" use="optional" default="false"> <xs:annotation> <xs:documentation>Trace width tolerance definitiion - if true a percentage of Val, if false an absolute a value, to add or substracted fromVal.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="TraceSeparation"> <xs:annotation> <xs:documentation>Contains the desired distance between
the related conductors.</xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="Val" type="xs:double" use="required"> <xs:annotation> <xs:documentation>Contains the target separation between of the related conductor. Default unit is MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units" type="UnitsType" use="optional" default="MIL"> <xs:annotation> <xs:documentation>Contains the unit of measure used for by the value in Val.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="IsPitch" type="xs:boolean" use="optional" default="true"> <xs:annotation> <xs:documentation>Trace Separation definitiion - if true the spacing between the conductors are measured from center line to center line or pitch, if false a value for the spacing is edge to edge of the conductors.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="RefPlane" minOccurs="0" maxOccurs="2"> <xs:annotation> <xs:documentation>Contains the list of layer that represent the refence planes used during the impedance calculation.</ xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="RefLayerName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The LayerName value of the layer found under StackupFile.EdaData.Stackup.Group.Layer that represent a refeence plan used during the impedance calculation.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence> <xs:attribute name="LayerName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The Layer name used to reference the specific Impedance Type.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Structure" type="Structure" use="optional"> <xs:annotation> <xs:documentation>Contains the impedance structure definition in the area of stripline, microstrip or coplanar waveguided.</
xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="ZoCalculatedOhms" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>If the design source has an impedance similator this would contain the calculated single-ended calculation result for this impedance instance.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="ZDiffCalculatedOhms" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>If the design source has an impedance similator this would contain the calculated differential calculation result for this impedance instance.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="InsertionLoss" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The resulting lost of single power.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="InsertionLossUnits" type="InsertionLossType" use="optional" default="DB/INCH"> <xs:annotation> <xs:documentation>Units for InsertionLoss. Default is dB/Inch.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence> <xs:attribute name="ImpName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The name used to reference the specific Impedance.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="ZoValOhms" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>Single-ended impedance target value in Ohms.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="ZoPlusVal" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>A positive value representing the plus value to add to the target single-ended impedance value ZoValOhms. (tolerance) Use of ZoPlusVal determined by the ZoValPercent value.</ xs:documentation> </xs:annotation>
</xs:attribute> <xs:attribute name="ZoMinusVal" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>A positive value representing the plus value to subtract from the target single-ended impedance value ZoValOhms. (tolerance) Use of ZoPMinusVal determined by the ZoValPercent value.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="ZoValPercent" type="xs:boolean" use="optional" default="true"> <xs:annotation> <xs:documentation>Single-ended tolerance definitiion - if true a percentage of ZoValOhms, if false an absolute a value to add or substract from ZoValOhms.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="ZDiffValOhms" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>Differential impedance target value in Ohms.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="ZDiffPlusVal" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>A positive value representing the plus value to add to the target differential impedance value ZDiffValOhms. (tolerance) Use of ZDiffPlusVal determined by the ZDiffValPercent value.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="ZDiffMinusVal" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>A positive value representing the plus value to subract from the target differential impedance value ZDiffValOhms. (tolerance) Use of ZDiffMinusVal determined by the ZDiffValPercent value.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="ZDiffValPercent" type="xs:boolean" use="optional" default="true"> <xs:annotation> <xs:documentation>Differential tolerance definitiion - if true a percentage of ZDiffValOhms, if false an absolute a value, to add or substract from ZDiffValOhms.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence> <xs:attribute name="SpecName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The name used to reference the specific Spec.</xs:documentation>
</xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence> </xs:complexType> </xs:element> <xs:element name="Stackup"> <xs:annotation> <xs:documentation>Contains the stackup representation as delivered by the design source.</xs:documentation> </xs:annotation> <xs:complexType> <xs:sequence> <xs:element name="Group" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>A stackup is created by mutliple Group which is comprised of a collection of Materials with condutor materials tied to copper layers of the design. The series is represented from the top of the design to the bottom.</xs:documentation> </xs:annotation> <xs:complexType> <xs:sequence> <xs:element name="Layer" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>A layer definition within the Group.</ xs:documentation> </xs:annotation> <xs:complexType> <xs:sequence> <xs:element name="SpecRef" minOccurs="0" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>The list Material and Impedance Specs and conductor requirements for a layer.</xs:documentation> </xs:annotation> <xs:complexType> <xs:sequence> <xs:element name="Material" minOccurs="0"> <xs:annotation> <xs:documentation>Defines the Material requirements for a layer.</xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="MaterialName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The name used for referencing the designated Material within the referenced SpecName.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="PropertyName" type="xs:string" use="optional"> <xs:annotation> <xs:documentation>The name used for referencing the designated Properties within the referenced Material. If there is only one Property defined then that will be considered the default and the existance of the attribute FrequencyVal not required.</xs:documentation>
</xs:annotation> </xs:attribute> <xs:attribute name="FrequencyVal" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>Contains the frequency of the signal on the net. Could be used to reference additional material content when used as a reference into PropertyName. If there is only one Property defined then that will be considered the default and the existance of the attribute is not required.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="CopperAreaPrecent" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>A percentage calculated by finding the copper area of a layer and dividing that by the total area of layer laminiate.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="TraceWidthTop" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The etching of copper is trapezoidal ends with the top of the copper is narrower than the bottom. This attribute contains the width of the top of a trace located on the design. If not present then the value found in TraceWidthBottom is assume as a starting point. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="TraceWidthBottom" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The etching of copper is trapezoidal ends with the top of the copper is narrower than the bottom. This attribute contains the width of the bottom of a trace located on the design. For conductor layer types this value is required. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units_TraceWidth" type="UnitsType" use="optional" default="MIL"> <xs:annotation> <xs:documentation>The unit value that the TraceWidthTop and TraceWidthBottom attributes are to be measured in. </ xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="Impedance" minOccurs="0"> <xs:annotation> <xs:documentation>Defines the Impedance requirements for a layer.</xs:documentation> </xs:annotation> <xs:complexType>
<xs:attribute name="ImpName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The name used for referencing the designated Impedance.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="ImpTypeName" type="ImpedanceType" use="required"> <xs:annotation> <xs:documentation>The type of impedance to use within the designated Impedance.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence> <xs:attribute name="MaterialSpecName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The name used for referencing the selected Material Spec.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="ImpSpecName" type="xs:string" use="optional"> <xs:annotation> <xs:documentation>The name used for referencing the selected Impedance Spec.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence> <xs:attribute name="LayerName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>A name of layer used within the design.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="LayerType" type="LayerType" use="optional" default="DOCUMENT"> <xs:annotation> <xs:documentation>An enumerated list of layer type representing the purpose behind the layer. Default is DOCUMENT.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="LayerSubType" type="LayerSubType" use="optional"> <xs:annotation> <xs:documentation>An enumerated list of sub layer type when used to further refine the meaning behind the value found it LayerType. For example, a LayerType DRILL with a SubType BACKDRILL.</ xs:documentation> </xs:annotation> </xs:attribute>
<xs:attribute name="MechStartLayerName" type="xs:string" use="optional"> <xs:annotation> <xs:documentation>In the event LayerType has the value of DRILL or ROUT, this atribute value represents the beginning layer named where the material in mechanically penetrated.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="MechEndLayerName" type="xs:string" use="optional"> <xs:annotation> <xs:documentation>In the event LayerType has the value of DRILL or ROUT, this atribute value represents the final layer named where the material in mechanically penetrated.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Side" type="SideType" use="optional" default="NONE"> <xs:annotation> <xs:documentation>An enumerated list of a value declaring the relative position of the layer within the stackup. Default is NONE.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Description" type="xs:string" use="optional"> <xs:annotation> <xs:documentation>Open description from the deisgn company of the originating layer.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Comment" type="xs:string" use="optional"> <xs:annotation> <xs:documentation>Open comment from the design company of the originating layer.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence> <xs:attribute name="GroupName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The name used to reference the Group.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="GroupThickness" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The total thickness for the group of layers. Default unit is MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units" type="UnitsType" use="optional" default="MIL"> <xs:annotation> <xs:documentation>The unit value that the GroupThickness
attribute are to be measured in. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="NumberOfLaminateCycles" type="xs:integer" use="optional"> <xs:annotation> <xs:documentation>Total number of lamination cycles the group of layers will be subjected to from the beginning to the end of the booking process.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence> <xs:attribute name="StackupName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The name used to reference the Stackup.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="StackupThickness" type="xs:double" use="required"> <xs:annotation> <xs:documentation>The target board thickness. Default unit is MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="PlusTol" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>A positive value representing the plus value to add to the target stackup thickness StackupThickness</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="MinusTol" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>A positive value representing the negative value to subtracted from the target stackup thickness StackupThickness</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units" type="UnitsType" use="optional" default="MIL"> <xs:annotation> <xs:documentation>The unit value that the StackupThickness, PlusTol and MinusTol attributes are to be measured in. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="WhereMeasured" type="WhereMeasured" use="optional" default="METAL"> <xs:annotation> <xs:documentation>An enumerated value of whare the StackupThickness is measuared from.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="TotalLaminationCycles" type="xs:integer"
use="optional"> <xs:annotation> <xs:documentation>Total number of lamination cycles required to complete the booking process.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence> <xs:attribute name="CompanyName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The name of the design company of the originating stackup.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="ContactName" type="xs:string" use="optional"> <xs:annotation> <xs:documentation>The name of the contact of the originating stackup.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Address" type="xs:string" use="optional"> <xs:annotation> <xs:documentation>The postal address of the deisgn company of the originating stackup.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="PhoneNumber" type="xs:string" use="optional"> <xs:annotation> <xs:documentation>The phone number of the deisgn company of the originating stackup.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Comment" type="xs:string" use="optional"> <xs:annotation> <xs:documentation>Open comment from the design company of the originating stackup.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="SupplierData" minOccurs="0" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Represents instances of a manufacturing stackup each with the required content deteremined by suppliers. It should contain a full stackup defining the final materials and impedance calculation based the material of use.</xs:documentation> </xs:annotation> <xs:complexType> <xs:sequence> <xs:element name="Specs"> <xs:annotation> <xs:documentation>Contains a list of specification (Spec) of material used during stack design and impedance requirements.</ xs:documentation> </xs:annotation> <xs:complexType> <xs:sequence>
<xs:element name="Spec" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>An indiviual Spec defining a collection of materials and impedance requirements. The Spec is select later through the use of the SpecName attribute.</xs:documentation> </xs:annotation> <xs:complexType> <xs:sequence> <xs:element name="Material" minOccurs="0" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>A Material specficiation defining a specific material, dielectric or conductor. The Material is select later through the use of the MaterialName attribute.</xs:documentation> </xs:annotation> <xs:complexType> <xs:sequence> <xs:element name="Dielectric" minOccurs="0"> <xs:annotation> <xs:documentation>A definition of a specific piece of dielectric material. </xs:documentation> </xs:annotation> <xs:complexType> <xs:sequence> <xs:element name="Properties" minOccurs="0" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Contains a list of Frequencies related to the material behavior. Material's electrical characteristics are influenced by the frequeny of the impedance net.The Frequencies is selected later through the use of the FrequencyName attrbute.</ xs:documentation> </xs:annotation> <xs:complexType> <xs:sequence> <xs:element name="Property" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>A specific frequency and the related electrical characteristics.</xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="FrequencyVal" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The value of the single frequency. Default is GHz.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units" type="FrequencyType" use="optional" default="GHz"> <xs:annotation> <xs:documentation>The unit of the FrequenceVal frequency.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="DielectricConstant_Dk" type="xs:double" use="optional"> <xs:annotation>
<xs:documentation>The Dielectric Constant (DK) at the specified FrequencyVal frequency.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="LossTangent_Df" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The Loss Tangent (Df) at the specified FrequencyVal frequency.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Thickness" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The overriding thickness of the dielectric material. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Finished_Thickness" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The overriding finished thickness of the dielectric material. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units_Thickness" type="UnitsType" use="optional" default="MIL"> <xs:annotation> <xs:documentation>The unit value that the Thickness and Finished_Thickness attribute is to be measured in. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence> <xs:attribute name="PropertyName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The name used to reference the specific Frequency.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence> <xs:attribute name="DielectricType" type="DielecticType" use="required"> <xs:annotation> <xs:documentation>Defines the generic type of dielelectric materials, prepreg or core or other.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="OtherSubType" type="OtherType"
use="optional"> <xs:annotation> <xs:documentation>A list of material definition that will most often be used when the DielectricType is OTHER.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="MaterialReference" type="xs:string" use="optional"> <xs:annotation> <xs:documentation>A free string of text that provides the material suppliers reference name.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="GlassStyle_Construction" type="xs:string" use="optional"> <xs:annotation> <xs:documentation>A free string of text that description the Prepreg glass or Core construction.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="ResinContent_Percent" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The percentage of resin found in the dielectric material.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Description" type="xs:string" use="optional"> <xs:annotation> <xs:documentation>Open description regarding the dielectric material.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Comment" type="xs:string" use="optional"> <xs:annotation> <xs:documentation>Open commnent regarding the dielectric material.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="Conductor" minOccurs="0"> <xs:annotation> <xs:documentation>A definition of a specific piece of conductive material. </xs:documentation> </xs:annotation> <xs:complexType> <xs:sequence> <xs:element name="Properties" minOccurs="0" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Contains a list of Properties related to the material behavior. The Property is selected later through the use of the PropertyName attrbute.</xs:documentation> </xs:annotation>
<xs:complexType> <xs:sequence> <xs:element name="PropertyName"> <xs:annotation> <xs:documentation>A specific property and the related material characteristics.</xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="Conductivity_mho_cm" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The Conductivity of the copper measured in MHO/CM.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="SurfaceRoughnessFacingCore_Rz" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>In core materials the surface roughness of the copper facing the core measured in Rz.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="SurfaceRoughnessFacingPrepreg_Rz" type="xs:decimal" use="optional"> <xs:annotation> <xs:documentation>In core materials the surface roughness of the copper facing the prepreg measured in Rz.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="SurfaceRoughnessFoil_Rz" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>For copper foil or sheet materials the surface roughness measured in Rz.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="DielectricConstant_Dk" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The Dielectric Constant (DK) contributed to the resin during the lamination process.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="LossTangent_Df" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The Loss Tangent (Df) at the scontributed to the resin during the lamination process.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Thickness" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The overriding thickness of the conductor material. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</xs:documentation>
</xs:annotation> </xs:attribute> <xs:attribute name="Finished_Thickness" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The overriding finished thickness of the conductor material. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units_Thickness" type="UnitsType" use="optional" default="MIL"/> </xs:complexType> </xs:element> </xs:sequence> <xs:attribute name="PropertyName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The name used to reference the specific set of Properties.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence> <xs:attribute name="ConductorType" type="ConductorType" use="required"> <xs:annotation> <xs:documentation>The type of conductor. The values are COPPER or OTHER.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="CopperWeight_oz_ft2" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>This is mainly a historical means to specify copper thickness. The intended value to be used in this case is Thickness located just under Material.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Description" type="xs:string" use="optional"> <xs:annotation> <xs:documentation>Open description regarding the conductive material.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Comment" type="xs:string" use="optional"> <xs:annotation> <xs:documentation>Open commnent regarding the conductive material.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="Default_Thickness">
<xs:annotation> <xs:documentation>A definition of the dielectric or conductor material supplier delievered thickness.</xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="Thickness" type="xs:double" use="required"> <xs:annotation> <xs:documentation>The default thickness of the dielectric or conductor material. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Finished_Thickness" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The default finished thickness of the dielectric or conductor material. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units" type="UnitsType" use="optional" default="MIL"> <xs:annotation> <xs:documentation>The unit value that the Thickness and Finished_Thickness attribute is to be measured in. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence> <xs:attribute name="MaterialName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The name used to reference the specific Material.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="Impedance" minOccurs="0" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>A Impedance specficiation defining the general impedance goal and then the phyical characteristics. The Impedance is select later through the use of the ImplName attribute.</ xs:documentation> </xs:annotation> <xs:complexType mixed="true"> <xs:sequence> <xs:element name="Single_Ended" minOccurs="0" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>A representation of a single-ended impedance requirement.</xs:documentation> </xs:annotation>
<xs:complexType> <xs:sequence> <xs:element name="TraceWidth"> <xs:annotation> <xs:documentation>Contains the required trace width to use for the calculated impedance.</xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="TraceWidthBottom" type="xs:double" use="required"> <xs:annotation> <xs:documentation>The etching of copper is trapezoidal ends with the top of the copper is narrower than the bottom. This attribute contains the width of the bottom of a trace located on the design. For conductor layer types this value is required. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="TraceWidthTop" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The etching of copper is trapezoidal ends with the top of the copper is narrower than the bottom. This attribute contains the width of the top of a trace located on the design. If not present then the value found in TraceWidthBottom is assume as a starting point. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units_TraceWidth" type="UnitsType" use="optional" default="MIL"> <xs:annotation> <xs:documentation>The unit value that the TraceWidthTop and TraceWidthBottom attributes are to be measured in. </ xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="RefPlane" minOccurs="0" maxOccurs="2"> <xs:annotation> <xs:documentation>Contains the list of layer that represent the refence planes used during the impedance calculation.</ xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="RefLayerName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The LayerName value of the layer found under StackupFile.SupplerData.Stackup.Group.Layer that represent a refeence plan used during the impedance calculation.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence>
<xs:attribute name="LayerName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The Layer name used to reference the specific Impedance Type.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Structure" type="Structure" use="optional"> <xs:annotation> <xs:documentation>Contains the impedance structure definition in the area of stripline, microstrip or coplanar waveguided.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="ZoCalculatedOhms" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>Contains the calculated single-ended calculation result for this impedance instance.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="Differential_Coplanar_Waveguide" minOccurs="0" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>A representation of a differential Coplanar waveguided impedance requirement.</xs:documentation> </xs:annotation> <xs:complexType> <xs:sequence> <xs:element name="TraceWidth"> <xs:annotation> <xs:documentation>Contains the required trace width to use for the calculated impedance.</xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="TraceWidthBottom" type="xs:double" use="required"> <xs:annotation> <xs:documentation>The etching of copper is trapezoidal ends with the top of the copper is narrower than the bottom. This attribute contains the width of the bottom of a trace located on the design. For conductor layer types this value is required. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="TraceWidthTop" type="xs:double" use="optional"> <xs:annotation> trapezoidal ends with the top of the copper is narrower than the bottom. design. If not present then the value found in TraceWidthBottom is assume
<xs:documentation>The etching of copper is This attribute contains the width of the top of a trace located on the as a starting point. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</xs:documentation>
</xs:annotation> </xs:attribute> <xs:attribute name="Units_TraceWidth" type="UnitsType" use="optional" default="MIL"> <xs:annotation> <xs:documentation>The unit value that the TraceWidthTop and TraceWidthBottom attributes are to be measured in. </ xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="Spacing"> <xs:annotation> <xs:documentation>Contains the required spacing between copper for the calculated impedance.</xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="Val" type="xs:double" use="required"> <xs:annotation> <xs:documentation>Contains the required spacing for the related conductor. Default units is MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units" type="UnitsType" use="optional" default="MIL"> <xs:annotation> <xs:documentation>Contains the unit of measure used for by the value in Val.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="CoplanarSpacing"> <xs:annotation> <xs:documentation>Contains the coplanar desired spacing to use for the calculated impedance.</xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="Val" type="xs:double" use="required"> <xs:annotation> <xs:documentation>Contains the required coplanar spacing of the related conductor. Default units is MIL.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units" type="UnitsType" use="optional" default="MIL"> <xs:annotation> <xs:documentation>Contains the unit of measure used for by the value in Val.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="CoplanarTraceWidth" minOccurs="0">
<xs:annotation> <xs:documentation>Contains the coplanar desired trace width to use for the target impedance. In the case of reference a plane this attribute is to not be defined.</xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="TraceWidthBottom" type="xs:double" use="required"> <xs:annotation> <xs:documentation>The etching of copper is trapezoidal ends with the top of the copper is narrower than the bottom. This attribute contains the width of the bottom of a trace located on the design. For conductor layer types this value is required. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="TraceWidthTop" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The etching of copper is trapezoidal ends with the top of the copper is narrower than the bottom. This attribute contains the width of the top of a trace located on the design. If not present then the value found in TraceWidthBottom is assume as a starting point. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units_TraceWidth" type="UnitsType" use="optional" default="MIL"> <xs:annotation> <xs:documentation>The unit value that the TraceWidthTop and TraceWidthBottom attributes are to be measured in. </ xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="RefPlane" minOccurs="0" maxOccurs="2"> <xs:annotation> <xs:documentation>Contains the list of layer that represent the refence planes used during the impedance calculation.</ xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="RefLayerName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The LayerName value of the layer found under StackupFile.SupplierData.Stackup.Group.Layer that represent a refeence plan used during the impedance calculation.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence> <xs:attribute name="LayerName" type="xs:string" use="required">
<xs:annotation> <xs:documentation>The Layer name used to reference the specific Impedance Type.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Structure" type="Structure" use="optional"> <xs:annotation> <xs:documentation>Contains the impedance structure definition in the area of stripline, microstrip or coplanar waveguided.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="ZoCalculatedOhms" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>Contains the calculated single-ended calculation result for this impedance instance.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="ZDiffCalculatedOhms" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>Contains the calculated differential calculation result for this impedance instance.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="InsertionLossUnits" type="InsertionLossType" use="optional" default="DB/INCH"> <xs:annotation> <xs:documentation>Units for InsertionLoss. Default is dB/Inch.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="InsertionLoss" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The resulting lost of single power.</ xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="Differential_Edge_Coupled" minOccurs="0" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>A representation of a differential edge coupled impedance requirement.</xs:documentation> </xs:annotation> <xs:complexType> <xs:sequence> <xs:element name="TraceWidth"> <xs:annotation> <xs:documentation>Contains the required trace width to use for the calculated impedance.</xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="TraceWidthBottom" type="xs:double"
use="required">
<xs:annotation> <xs:documentation>The etching of copper is trapezoidal ends with the top of the copper is narrower than the bottom. This attribute contains the width of the bottom of a trace located on the design. For conductor layer types this value is required. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="TraceWidthTop" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The etching of copper is trapezoidal ends with the top of the copper is narrower than the bottom. This attribute contains the width of the top of a trace located on the design. If not present then the value found in TraceWidthBottom is assume as a starting point. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units_TraceWidth" type="UnitsType" use="optional" default="MIL"> <xs:annotation> <xs:documentation>The unit value that the TraceWidthTop and TraceWidthBottom attributes are to be measured in. </ xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="Spacing"> <xs:annotation> <xs:documentation>Contains the required spacing between copper for the calculated impedance.</xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="Val" type="xs:double" use="required"> <xs:annotation> <xs:documentation>Contains the required spacing for the related conductor. Default units is MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units" type="UnitsType" use="optional" default="MIL"> <xs:annotation> <xs:documentation>Contains the unit of measure used for by the value in Val.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="RefPlane" minOccurs="0" maxOccurs="2"> <xs:annotation> <xs:documentation>Contains the list of layer that represent the refence planes used during the impedance calculation.</ xs:documentation>
</xs:annotation> <xs:complexType> <xs:attribute name="RefLayerName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The LayerName value of the layer found under StackupFile.SupplierData.Stackup.Group.Layer that represent a refeence plan used during the impedance calculation.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence> <xs:attribute name="LayerName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The Layer name used to reference the specific Impedance Type.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Structure" type="Structure" use="optional"> <xs:annotation> <xs:documentation>Contains the impedance structure definition in the area of stripline, microstrip or coplanar waveguided.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="ZoCalculatedOhms" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>Contains the calculated single-ended calculation result for this impedance instance.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="ZDiffCalculatedOhms" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>Contains the calculated differential calculation result for this impedance instance.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="InsertionLoss" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The resulting lost of single power.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="InsertionLossUnits" type="InsertionLossType" use="optional" default="DB/INCH"> <xs:annotation> <xs:documentation>Units for InsertionLoss. Default is dB/Inch.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element>
<xs:element name="Single_Ended_Coplanar_Waveguide" minOccurs="0" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>A representation of a single-ended Coplanar waveguided impedance requirement.</xs:documentation> </xs:annotation> <xs:complexType> <xs:sequence> <xs:element name="TraceWidth"> <xs:annotation> <xs:documentation>Contains the required trace width to use for the calculated impedance.</xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="TraceWidthBottom" type="xs:double" use="required"> <xs:annotation> <xs:documentation>The etching of copper is trapezoidal ends with the top of the copper is narrower than the bottom. This attribute contains the width of the bottom of a trace located on the design. For conductor layer types this value is required. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="TraceWidthTop" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The etching of copper is trapezoidal ends with the top of the copper is narrower than the bottom. This attribute contains the width of the top of a trace located on the design. If not present then the value found in TraceWidthBottom is assume as a starting point. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units_TraceWidth" type="UnitsType" use="optional" default="MIL"> <xs:annotation> <xs:documentation>The unit value that the TraceWidthTop and TraceWidthBottom attributes are to be measured in. </ xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="CoplanarSpacing"> <xs:annotation> <xs:documentation>Contains the required spacing between copper for the calculated impedance.</xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="Val" type="xs:double" use="required"> <xs:annotation> <xs:documentation>Contains the required spacing for the related conductor. Default units is MIL.</xs:documentation> </xs:annotation>
</xs:attribute> <xs:attribute name="Units" type="UnitsType" use="optional" default="MIL"> <xs:annotation> <xs:documentation>Contains the unit of measure used for by the value in Val.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="CoplanarTraceWidth" minOccurs="0"> <xs:annotation> <xs:documentation>Contains the coplanar desired trace width to use for the target impedance. In the case of reference a plane this attribute is to not be defined.</xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="TraceWidthBottom" type="xs:double" use="required"> <xs:annotation> <xs:documentation>The etching of copper is trapezoidal ends with the top of the copper is narrower than the bottom. This attribute contains the width of the bottom of a trace located on the design. For conductor layer types this value is required. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="TraceWidthTop" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The etching of copper is trapezoidal ends with the top of the copper is narrower than the bottom. This attribute contains the width of the top of a trace located on the design. If not present then the value found in TraceWidthBottom is assume as a starting point. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units_TraceWidth" type="UnitsType" use="optional" default="MIL"> <xs:annotation> <xs:documentation>The unit value that the TraceWidthTop and TraceWidthBottom attributes are to be measured in. </ xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="RefPlane" minOccurs="0" maxOccurs="2"> <xs:annotation> <xs:documentation>Contains the list of layer that represent the refence planes used during the impedance calculation.</ xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="RefLayerName" type="xs:string" use="required">
<xs:annotation>
<xs:documentation>The LayerName value of the layer found under StackupFile.SupplierData.Stackup.Group.Layer that represent a refeence plan used during the impedance calculation.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence> <xs:attribute name="LayerName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The Layer name used to reference the specific Impedance Type.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Structure" type="Structure" use="optional"> <xs:annotation> <xs:documentation>Contains the impedance structure definition in the area of stripline, microstrip or coplanar waveguided.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="ZoCalculatedOhms" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>Contains the calculated single-ended calculation result for this impedance instance.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="ZDiffCalculatedOhms" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>Contains the calculated differential calculation result for this impedance instance.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="Differential_Broadside_Coupled" minOccurs="0" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>A representation of a differential broadshide coupled impedance requirement.</xs:documentation> </xs:annotation> <xs:complexType> <xs:sequence> <xs:element name="TraceWidth"> <xs:annotation> <xs:documentation>Contains the required trace width to use for the calculated impedance.</xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="TraceWidthBottom" type="xs:double" use="required"> <xs:annotation> <xs:documentation>The etching of copper is
trapezoidal ends with the top of the copper is narrower than the bottom. This attribute contains the width of the bottom of a trace located on the design. For conductor layer types this value is required. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="TraceWidthTop" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The etching of copper is trapezoidal ends with the top of the copper is narrower than the bottom. This attribute contains the width of the top of a trace located on the design. If not present then the value found in TraceWidthBottom is assume as a starting point. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units_TraceWidth" type="UnitsType" use="optional" default="MIL"> <xs:annotation> <xs:documentation>The unit value that the TraceWidthTop and TraceWidthBottom attributes are to be measured in. </ xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="TraceSeparation"> <xs:annotation> <xs:documentation>Contains the required distance between the related conductors.</xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="Val" type="xs:double" use="required"> <xs:annotation> <xs:documentation>Contains the required separation between of the related conductor. Default units is MIL.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units" type="UnitsType" use="optional" default="MIL"> <xs:annotation> <xs:documentation>Contains the unit of measure used for by the value in Val.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="IsPitch" type="xs:boolean" use="optional" default="false"> <xs:annotation> <xs:documentation>Trace Separation definitiion - if true the spacing between the conductors are measured from center line to center line or pitch, if false a value for the spacing is edge to edge of the conductors.</xs:documentation> </xs:annotation> </xs:attribute>
</xs:complexType> </xs:element> <xs:element name="RefPlane" minOccurs="0" maxOccurs="2"> <xs:annotation> <xs:documentation>Contains the list of layer that represent the refence planes used during the impedance calculation.</ xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="RefLayerName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The LayerName value of the layer found under StackupFile.SupplierData.Stackup.Group.Layer that represent a refeence plan used during the impedance calculation.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence> <xs:attribute name="LayerName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The Layer name used to reference the specific Impedance Type.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Structure" type="Structure" use="optional"> <xs:annotation> <xs:documentation>Contains the impedance structure definition in the area of stripline, microstrip or coplanar waveguided.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="ZoCalculatedOhms" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>Contains the calculated single-ended calculation result for this impedance instance.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="ZDiffCalculatedOhms" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>Contains the calculated differential calculation result for this impedance instance.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="InsertionLoss" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The resulting lost of single power.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="InsertionLossUnits" type="InsertionLossType" use="optional" default="DB/INCH">
<xs:annotation> <xs:documentation>Units for InsertionLoss. Default is dB/Inch.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence> <xs:attribute name="ImpName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The name used to reference the specific Impedance.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence> <xs:attribute name="SpecName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The name used to reference the specific Spec.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence> </xs:complexType> </xs:element> <xs:element name="Stackup"> <xs:annotation> <xs:documentation>Contains the manufacturing stackup representation determined by the supplier.</xs:documentation> </xs:annotation> <xs:complexType> <xs:sequence> <xs:element name="Group" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>A stackup is created by mutliple Group which is comprised of a collection of Materials with condutor materials tied to copper layers of the design. The series is represented from the top of the design to the bottom.</xs:documentation> </xs:annotation> <xs:complexType> <xs:sequence> <xs:element name="Layer" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>A layer definition within the Group.</ xs:documentation> </xs:annotation> <xs:complexType> <xs:sequence> <xs:element name="SpecRef" minOccurs="0"> <xs:annotation> <xs:documentation>The list Material and Impedance Specs and conductor requirements for a layer.</xs:documentation> </xs:annotation> <xs:complexType>
<xs:sequence>
<xs:element name="Material" minOccurs="0"> <xs:annotation> <xs:documentation>Defines the Material requirements for a layer.</xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="MaterialName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The name used for referencing the designated Material within the referenced SpecName.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="PropertyName" type="xs:string" use="optional"> <xs:annotation> <xs:documentation>The name used for referencing the designated Properties within the referenced Material. If there is only one Property defined then that will be considered the default and the existance of the attribute FrequencyVal not required.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="FrequencyVal" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>Contains the frequency of the signal on the net. Could be used to reference additional material content when used as a reference into FrequencyName. If there is only one Frequency defined then that will be considered the default and the existance of the attribute is not required.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="CopperAreaPercent" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>A percentage calculated by finding the copper area of a layer and dividing that by the total area of layer laminiate.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence> <xs:attribute name="MaterialSpecName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The name used for referencing the selected Material Spec.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="ImpSpecName" type="xs:string" use="optional"> <xs:annotation> <xs:documentation>The name used for referencing the selected Impedance Spec.</xs:documentation> </xs:annotation> </xs:attribute>
</xs:complexType> </xs:element> </xs:sequence> <xs:attribute name="LayerName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>A name of layer that in most case found within the EdaData.Stackup.Group.Layer section. If the following Layer attributes are missing they are taken from that reference. Otherwise they may need to be added.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="LayerType" type="LayerType" use="optional" default="DOCUMENT"> <xs:annotation> <xs:documentation>An enumerated list of layer type representing the purpose behind the layer. Default is DOCUMENT.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="LayerSubType" type="LayerSubType" use="optional"> <xs:annotation> <xs:documentation>An enumerated list of sub layer type when used to further refine the meaning behind the value found it LayerType. For example, a LayerType DRILL with a SubType BACKDRILL.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="MechStartLayerName" type="xs:string" use="optional"> <xs:annotation> <xs:documentation>In the event LayerType has the value of DRILL or ROUT, this atribute value represents the beginning layer named where the material in mechanically penetrated.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="MechEndLayerName" type="xs:string" use="optional"> <xs:annotation> <xs:documentation>In the event LayerType has the value of DRILL or ROUT, this atribute value represents the final layer named where the material in mechanically penetrated.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Side" type="SideType" use="optional" default="NONE"> <xs:annotation> <xs:documentation>An enumerated list of a value declaring the relative position of the layer within the stackup. Default is NONE.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Description" type="xs:string" use="optional"> <xs:annotation> <xs:documentation>Open description from the supplier of the Layer.</xs:documentation>
</xs:annotation> </xs:attribute> <xs:attribute name="Comment" type="xs:string" use="optional"> <xs:annotation> <xs:documentation>Open comment from the supplier of the Layer.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence> <xs:attribute name="GroupName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The name used to reference the Group.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="GroupThickness" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The total thickness for the group of layers. Default unit is MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units" type="UnitsType" use="optional" default="MIL"> <xs:annotation> <xs:documentation>The unit value that the GroupThickness attribute are to be measured in. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="NumberOfLaminateCycles" type="xs:integer" use="optional"> <xs:annotation> <xs:documentation>Total number of lamination cycles the group of layers will be subjected to from the beginning to the end of the booking process.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence> <xs:attribute name="StackupName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The name used to reference the Stackup.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="StackupThickness" type="xs:double" use="required"> <xs:annotation> <xs:documentation>The calculated board thickness. Default unit is MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Status" type="StackupStatus" use="optional"
default="SUBMITTED"> <xs:annotation> <xs:documentation>A stackup as one of five values, SELECTED indicates the stackup the fabricator should build from, VALID indicates the a design team has determine the stackup would meet the needs, INVALID indicate that somewhere a team determined the stackup was not to be used for any reason, SUBMITTED is the default state which means the stackup has not yet been validated for use and UNDER REVIEW indicates that stackup is being reviewed for use.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units" type="UnitsType" use="optional" default="MIL"> <xs:annotation> <xs:documentation>The unit value that the StackupThickness attribute are to be measured in. The default unit of measure is governed by StackupFile->DefaultUnits which is by default MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="WhereMeasured" type="WhereMeasured" use="optional" default="METAL"> <xs:annotation> <xs:documentation>An enumerated value of whare the StackupThickness is measuared from.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="TotalLaminationCycles" type="xs:integer" use="optional"> <xs:annotation> <xs:documentation>Total number of lamination cycles required to complete the booking process.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence> <xs:attribute name="CompanyName" use="required"> <xs:annotation> <xs:documentation>The name of the supplier defining the manufacturing stackup.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="ContactName" type="xs:string"> <xs:annotation> <xs:documentation>The name of the contact of the supplier stackup.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Address" type="xs:string"> <xs:annotation> <xs:documentation>The postal address of the supplier of the manufacturing stackup.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="PhoneNumber" type="xs:string"> <xs:annotation> <xs:documentation>The phone number of the supplier of the manaufacturing stackup.</xs:documentation>
</xs:annotation> </xs:attribute> <xs:attribute name="Comment" type="xs:string"> <xs:annotation> <xs:documentation>Open comment from the suppplier of the manafacturing stackup.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence> <xs:attribute name="Version" type="xs:string" use="required"> <xs:annotation> <xs:documentation>Defines the ODB++ Version of the stackup.xml file.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="DefaultUnits" type="UnitsType" use="optional" default="MIL"> <xs:annotation> <xs:documentation>The DefaultUnits carries the dimension Units value whenever referenced by the schema. The default UNITS are MIL, but that could be changed by assigning this attribute value to another unit.</ xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:schema>
Appendix F Impedance Schema
This appendix describes the elements, their related sub-elements, and the relevant attributes of the impedance file. Each element's description contains the following sections: parent element, hierarchical diagram, minimum and maximum numbers of occurrences, description of the attributes, and a list of sub-elements known as children. The full schema file is provided.
Elements or attributes enclosed in solid lines are mandatory. Those enclosed in dotted lines are optional. Plus or minus indicate the collapsed or expanded state of the element or attribute. The display of a numerical range under an element or attribute indicates its accepted range of values. Some elements are designated as simpleType-they specify constraints and information about the values of attributes or text-only elements. Other elements are complexType-an XML element that contains other elements or attributes.
| Impedances. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 512 | |-------------------------------------------------------------------------------------------------------------------------------------|-------| | Impedances/Descriptor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 513 | | Impedances/Descriptor/RequiredImpedance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 515 | | Impedances/Descriptor/OriginalTraceWidth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 517 | | Impedances/Descriptor/OriginalSpacing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 518 | | Impedances/Descriptor/RefPlane. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 519 | | Impedance Schema File. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 519 |
Impedances
The base of the Impedance content for the step.
Diagram
Attributes
| Name | Type | Use | Default | Description | |------------------|------------|----------|-----------|-----------------------------------------------------------------------------------------------------------------------------------------------| | Version | xs:string | required | | Defines the ODB++ Version of the impedance.xml file | | MaxImpIdVal Used | xs:integer | required | | Contains the largest Impendance - > Descriptor -> id value ever used. Eliminates the need of reuse if an Impendance -> Descriptor is deleted. |
Children
'Impedances/Descriptor' on page 513
<!-- image -->Impedances/Descriptor
A list of impedance requirements for the trace features that bear the id attribute and reside in the layer having a specific name.
Parent
'Impedances' on page 512
Diagram
<!-- image -->Occurrence
0-n
Attributes
| Name | Type | Use | Default | Description | |-----------------|------------|----------|-----------|----------------------------------------------------------------------------------------| | id | xs:integer | required | | A unique ID assigned to line features that use the .imp_constraint_id system attribute | | TraceLayerNa me | xs:string | required | | The name of the layer containing the traces to which the id attribute is assigned |
Children
-
'Impedances/Descriptor/RequiredImpedance' on page 515
-
'Impedances/Descriptor/OriginalTraceWidth' on page 517
-
'Impedances/Descriptor/OriginalSpacing' on page 518
-
'Impedances/Descriptor/RefPlane' on page 519
Impedances/Descriptor/RequiredImpedance
The required impedance values.
Parent
'Impedances/Descriptor' on page 513
Diagram
Occurrence
0-1
Attributes
| Name | Type | Use | Default | Description | |----------|-----------|----------|-----------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | ValOhms | xs:double | required | | Target impedance value in Ohms | | PlusVal | xs:double | optional | | A positive value representing the plus value to add to the target impedance value ValOhms (tolerance). The use of this attribute is determined by the value of the ValPercent attribute. | | MinusVal | xs:double | optional | | A positive value representing the plus value to subtract from the target impedance value ValOhms (tolerance). The use of this attribute is determined by the value of the ValPercent attribute. |
<!-- image -->| Name | Type | Use | Default | Description | |------------|------------|----------|-----------|-------------------------------------------------------------------------------------------------------------------------------------------| | ValPercent | xs:boolean | optional | true | Impedance tolerance definition: true -apercentage of the ValOhms value false -an absolute value to add or subtract from the ValOhms value |
Impedances/Descriptor/OriginalTraceWidth
Contains the original trace width for the required impedance.
Parent
'Impedances/Descriptor' on page 513
Diagram
Occurrence
0-1
Attributes
| Name | Type | Use | Default | Description | |--------|-----------|----------|-----------|-----------------------------------------------| | Val | xs:double | required | | The original trace width of the feature | | Units | UnitsType | optional | MIL | The unit of measure used by the Val attribute |
<!-- image -->Impedances/Descriptor/OriginalSpacing
Contains the original spacing between copper for the required impedance.
Parent
'Impedances/Descriptor' on page 513
Diagram
Occurrence
0-1
Attributes
| Name | Type | Use | Default | Description | |--------|-----------|----------|-----------|-----------------------------------------------| | Val | xs:double | required | | The original spacing between features | | Units | UnitsType | optional | MIL | The unit of measure used by the Val attribute |
<!-- image -->Impedances/Descriptor/RefPlane
Contains the list of layers that represent the reference planes in impedance calculation.
Parent
'Impedances/Descriptor' on page 513
Diagram
Occurrence
0-2
Attributes
| Name | Type | Use | Default | Description | |--------|------------|----------|-----------|-----------------------------------------------------------------------------------------------------------------------------------------| | Val | xs:integer | required | | The ODB++ ID value of the layer found under Matrix -> Layers -> Layer -> Id that represents a reference plane in impedance calculation. |
Impedance Schema File
This is the full schema file.
<!-- image --><?xml version="1.0" encoding="Windows-1252"?> <!-- edited with XMLSpy v2020 sp1 (x64) (http://www.altova.com) by Nina Kaluta (Mentor Graphics) --> <xs:schema xmlns:xs="http://www.w3.org/2001/XMLSchema" elementFormDefault="qualified" attributeFormDefault="unqualified"> <xs:simpleType name="UnitsType"> <xs:restriction base="xs:string"> <xs:enumeration value="MM"/> <xs:enumeration value="MICRON"/> <xs:enumeration value="INCH"/> <xs:enumeration value="MIL"/> </xs:restriction> </xs:simpleType> <xs:element name="Impedances"> <xs:complexType> <xs:sequence> <xs:element name="Descriptor" minOccurs="0" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>A list of Impedance requirement that are to be assign to trace features on the associated layer by name.</ xs:documentation> </xs:annotation> <xs:complexType> <xs:sequence> <xs:element name="RequiredImpedance" minOccurs="0"> <xs:annotation> <xs:documentation>The required impedance values.</ xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="ValOhms" type="xs:double" use="required"> <xs:annotation> <xs:documentation>Impedance target value in Ohms.</ xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="PlusVal" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>A positive value representing the plus value to add to the target impedance value ValOhms. (tolerance). Use of PlusVal determined by the ValPercent value.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="MinusVal" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>A positive value representing the plus value to subtract from the target impedance value ValOhms. (tolerance). Use of MinusVal determined by the ValPercent value.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="ValPercent" type="xs:boolean" use="optional" default="true"> <xs:annotation> <xs:documentation>Impedance tolerance definitiion - if true a percentage of ValOhms, if false an absolute a value to add or substract from ValOhms.</xs:documentation> </xs:annotation> </xs:attribute>
</xs:complexType> </xs:element> <xs:element name="OriginalTraceWidth" minOccurs="0"> <xs:annotation> <xs:documentation>Contains the orignal trace width to use for the required impedance.</xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="Val" type="xs:double" use="required"> <xs:annotation> <xs:documentation>The original trace width of the feature. Default unit is MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units" type="UnitsType" use="optional" default="MIL"> <xs:annotation> <xs:documentation>Contains the unit of measure used for by the value in Val.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="OriginalSpacing" minOccurs="0"> <xs:annotation> <xs:documentation>Contains the original spacing between copper for the required impedance.</xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="Val" type="xs:double" use="required"> <xs:annotation> <xs:documentation>The original spacing of the features. Default unit is MIL.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="Units" type="UnitsType" use="optional" default="MIL"> <xs:annotation> <xs:documentation>Contains the unit of measure used for by the value in Val.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> <xs:element name="RefPlane" minOccurs="0" maxOccurs="2"> <xs:annotation> <xs:documentation>Contains the list of layer that represent the reference plane used during the impedance calculation.</xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="Val" type="xs:integer" use="required"> <xs:annotation> <xs:documentation>The ODB++ ID value of the layer found under Matrix.Layers.Layer.Id that represent a reference plane used during the impedance calculation.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType>
</xs:element> </xs:sequence> <xs:attribute name="Id" type="xs:integer" use="required"> <xs:annotation> <xs:documentation>The unique Id to be assigned to line features using the .imp_constraint_id system attribute.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="TraceLayerName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The name of the layer containing the traces assign reside.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence> <xs:attribute name="Version" type="xs:string" use="required"> <xs:annotation> <xs:documentation>Defines the ODB++ Version of the impedance.xml file.</xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="MaxImpIdValUsed" type="xs:integer" use="required"> <xs:annotation> <xs:documentation>Contains the largest Impendance.Descriptor.id value ever used. Used to eliminate the possibility of reuse in the event a Impedances.Descriptor is deleted.</xs:documentation> </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:schema>
Appendix G XML SimpleType Elements
This appendix provides information on the SimpleType elements that specify constraints and information about attribute values in the XML files within the ODB++ directory structure.
Enumerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Enumerations
The enumerations used by XML attributes.
Polarity
Controls whether the graphic representation of features is to be considered to be solid.
Options
- POSITIVE - For layers of type SIGNAL, POWER_GROUND, and MIXED, the features represent copper; for layers of type SOLDER_PASTE, features represent paste.
Layers of type COMPONENT, SILKSCREEN, DRILL, ROUT, and DOCUMENTATION should always have POSITIVE polarity. This polarity value in the matrix is in no way connected to the intended artwork generation polarity.
Exception: In layers of type SOLDER_MASK and MASK, the features represent clearances in the physical mask, while polarity must be POSITIVE.
- NEGATIVE -The features represent laminate. This is most commonly used on layers of type POWER_GROUND where pad features represent clearance, and background content is copper.
LayerType
An enumerated list of layer types representing the purpose of the layer.
Options
- SIGNAL - A layer used for regular signal transfer
- POWER_GROUND - A plane layer, used for power or ground signals
- MIXED - A combination of a signal and a plane layer
- SOLDER_MASK - A layer used for solder mask application
523
- SILK_SCREEN - A layer used for application of text legend
- SOLDER_PASTE - A layer used for depositing solder paste for assembly
- DRILL - A layer used to produce drill programs
- ROUT - A layer used to produce rout program
- DOCUMENT - A layer used for drawings, testing, auxiliary processes, and so forth (default)
- MASK - A layer containing additional information used as the base type for all mask types
- DIELECTRIC - A dielectric layer that separates two copper layers
- CONDUCTIVE_PASTE - A layer used to represent the depositing of conductive materials.
- COMPONENT - A layer containing components locations and outlines
- POWER - A copper layer that carries the voltage of the PCB
- GROUND - A copper layer connected to the ground
LayerSubType
An enumerated list of layer subtypes that refine the LayerType value. For example, a LayerType DRILL with a SubType BACKDRILL.
Options
Values available when LayerType=DIELECTRIC:
- CORE - Material that is pre-pressed layers according to a pattern of copper foil prepreg - copper foil.
- PREPREG - Material that is constructed with fiberglass impregnated with resin. The resin is pre-dried, but not hardened, and when heated, flows to adhere to neighboring material.
For values available for other base layer types, see corresponding tables in 'Layer Subtypes' on page 70.
Context
The context of layer.
Options
- BOARD - A layer that participates in the actual board production.
- MISC - Any other layer that is used for drawings, testing, and so forth.
SideType
An enumerated list of a values declaring the relative position of the layer within the stackup.
Options
- NONE (default)
- TOP
- BOTTOM
- INNER
UnitsType
The units of measure.
Options
- MM
- MICRON
- INCH
- MIL (default)
WhereMeasured
An enumerated value indicating where to measure the StackupThickness value.
Options
- LAMINATE
- METAL
- MASK
- OTHER
Structure
The impedance structure definition for the stripline, microstrip, or Coplanar waveguide areas.
Options
-
STRIPLINE
-
PLANE_LESS_STRIPLINE
-
MICROSTRIP_EMBEDDED
-
MICROSTRIP_NO_MASK
-
MICROSTRIP_MASK_COVERED
-
COPLANAR_WAVEGUIDED_STRIPLINE
-
COPLANAR_WAVEGUIDED_NO_MASK
-
OPLANAR_WAVEGUIDED_MASK_COVERED
DielectricType
The generic type of dielectric materials.
Options
- PREPREG
- CORE
- OTHER
- UNDEFINED
ConductorType
The type of conductor.
Options
- COPPER
- OTHER
FrequencyType
The unit of the FrequenceVal attribute.
Options
- Hz
- MHz
- GHz
OtherType
A list of material definitions that are most often used when DielectricType=OTHER.
Options
-
COVERLAY
-
COVERCOAT
-
STIFFENER
-
PRESSURE_SENSITIVE_ADHESIVE
-
OSP_MASK
-
SILVER_MASK
-
CARBON_MASK
-
SOLDER_MASK
-
PLATING_MASK
-
IMMERSION_MASK
-
OTHER
ImpedanceType
The type of impedance to use within the designated Impedance.
Options
- SINGLE_ENDED
- DIFFERENTIAL_COPLANAR_WAVEGUIDED
- DIFFERENTIAL_EDGE_COUPLE
- SINGLE_ENDED_COPLANAR_WAVEGUIDED
- DIFFERENTIAL_BROADSIDE_COUPLED
InsertionLossType
Units for InsertionLoss.
Options
- DB/INCH (default)
- DB/CM
- DB/M
StackupStatus
The stackup status as one of the following values:
Options
-
SELECTED - The stackup is selected for use by the fabricator.
-
VALID - The stackup meets the needs of the design team.
-
INVALID - The stackup does not meet the needs of the design team.
-
SUBMITTED - The stackup has not been validated for use (default).
-
UNDER REVIEW - The stackup is being reviewed for use.
Appendix H Frequently Asked Questions
These are some frequently asked questions.
| Question | Reply | |------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Why is ODB++ data in ASCII? | ASCII data provides numerous advantages: • It is easy to read and understand. • Translators to and from the data formats are easier to write. • The data is portable between different architectures, independent of byte order, floating point formats, and so forth. • By compressing the ASCII files using standard compress commands, the size is smaller than the binary equivalent, because the compression algorithm is adaptive and works well when strings are repeated. | | To rotate a feature pad by 90 degrees, in what direction is the aperture rotated? | Clockwise. | | Do any of these symbols have negative components: donuts, butterflies, thermals, and moires? | Standard symbols are all positive. Holes in symbols are see- through by definition. | | When the start-point and end-point of a feature coincide, is this considered a 360-degree arc or a single point? | A 360-degree arc; there are no single point arcs in the ODB++ format. | | Can I draw an arc with a square symbol? | Arcs can be drawn only with a round symbol. | | When I specify an x, y location for text, where will the text string be located? | The version parameter for text records controls text placement. See 'T -Text Records' on page 180. | | What is the meaning of the optimize field in a netlist file? | It indicates that the net has been optimized and the end-point markers have been removed from mid-points. | | In a netlist file, how should the radius field be set for drills of 0.002 inches through non-SMDs? | The radius field will be 0.001 mils in this case. | | In a netlist file, what are staggered points? | These are points that have been staggered to make them accessible to test probes. |
<!-- image -->| Question | Reply | |--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Can feature files of user-defined symbols contain references to other user-defined symbols? | Yes, they can. But recursion, direct or indirect is not allowed. | | Regarding surfaces, is there a particular order in specifying holes and islands? | The order of containment must be preserved. Islands precede holes that are contained in them. Holes precede islands that are contained in them. Consider this containment | | Regarding surfaces, does the outermost island come first? | Yes. | | Regarding rounded or chamfered rectangles, how do I specify corners? | See 'Rounded/Chamfered Rectangles' on page 212. | | To offset a rectangular pad in Xor Y, should I use a standard symbol and use the standard ODB++ to create the offset? Is this the correct feature file for a rect pad 70x50 with an X offset of 5? # # Symbol name # $0 rect70x50 # # Pad definition # P .005 .0 0 P 0 0 | Instead of defining your own symbols with offsets, you should use the standard rect symbol, and offset the coordinate that references it, in the layer features file. | | Is there a list of recognized properties (PRP) on components (such as with system attributes)? And for PRP in the eda/data file. | There is no list of predefined properties in the ODB++ format. These are EDA-specific. | | When defining a PKG record (using / steps/step_name/eda/data), it seems that ODB++ expects closed geometries. Is it critical to have only closed elements? | Yes, you must close all polygons. |
| Question | Reply | |----------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | What is the correct order for the matrix layers? | This is the recommended sequence: • Top component, solderpaste, silkscreen, soldermask. • Copper layers in their order. • Soldermask, silkscreen, solderpaste, bottom component. • Drill layers in sequence from where the drills started, to the largest depth (largest to smallest), then layer 2 to the largest depth, and so forth. • Rout layers. • Document and misc layers. | | How are the net_num records numbered? | The net_num used in the top record corresponds to the sequence of the net records in the eda/data file. The first net record is net_num 0, the second is net_num 1, and so on. | | We have an elaborate tool set to define routing slots and milling contours. How is this data written to ODB++? | Milling (referred to as routing in fabrication, and not to be confused with routing of traces in design) is handled by defining a rout layer (similar to a drill layer). The features in this layer correspond to the outline of the shapes that need to be cut out. Arout layer is like any other layer, but for it to be used during fabrication, should contain only lines, arcs and circular pads (rout machines can also drill). | | What net do I assign to points that have no net defined? | Features that do not have a net defined should be assigned to net $NONE$, which should be defined in the eda/data file. You must add the net and all points to the cadnet file. | | What is the maximum line length in an ODB++ file? | The restrictions are different for different files. In general 1,400 characters is the limit, but there are exceptions. Any line over the defined limit will be read with the remainder of the line ignored, so comments can be longer than the limit. |
## Release 8.1 Update 2 February 2020 Unpublished work. © Siemens 2020 This document contains information that is confidential and proprietary to Mentor Graphics Corporation, Siemens Industry Sof...
## Table of Contents | Chapter 1 ODB++ Design Format Specification . . . . . . . . . . . | 13 | |-------------------------------------------------------------------------...
## Table of Contents | matrix/matrix (Matrix) . . . . . . . | 62 | |-----...
## Table of Contents . . . . . . . . . . . . . . . . . . . . . . | 95 | | wheels (Ge...
## Table of Contents | FGR -Feature Group Record. . . . . . . . . . . . . . . . . . . . . . | 118 | |--------------------------------------------------------------------------...
## Table of Contents | Appendix A | | |----------------------------------------------...
## Table of Contents . . | 300 | | . . Requirements Metadata Section . . . . . . . . . . . . . . . . . . . . . . . . ....
## Table of Contents | StackupFile/EdaData/Specs/Spec/Material/Default_Thickness . . . . . . . . . . . . . . . . . . . . . . ...
## Table of Contents StackupFile/EdaData/Specs/Spec/Impedance/Differential_Coplanar_Waveguide/RefPlane ...
## Table of Contents | 376 ...
## Table of Contents | 397 ...
## Table of Contents | StackupFile/SupplierData/Specs/Spec/Impedance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
## Table of Contents | 432 | | StackupFile/SupplierData/Specs/S...
## Table of Contents | 453 | | StackupFile/SupplierData/Stackup/Group/Layer/SpecRef/...
## Table of Contents | Impedances/Descriptor/OriginalSpacing. | 518 | |----------------------------------------------------------|-------| | Impedances/Descriptor/RefPlane. . . . ...
## List of Tables | Table B-1. ODB++ Product Attributes . . . . . . . | 271 | |------------------------------------------------------|-------| | Table B-2. ODB++ DFM Attributes . . . . . . . . ....
## Chapter 1 ODB++ Design Format Specification Competing in global markets requires PCB design organizations to continually seek ways to more effectively communicate their product definition data to ...
## Chapter 1 ODB++ Design Format Specification | Rotation and Mirroring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | 34 | |----...
## ODB++ Design 8.1 Update 2 Changes have been made to the ODB++ Design format in V8.0 and since V8.0. These changes were implemented in this version: - The ODB++ format has been renamed to ODB++ ...
## ODB++ 8.1 Update 1 These changes were implemented in this version: - The manual was fixed to specify the correct formula used to round the line ends for a line thermal symbol. See 'Basic Standar...
## ODB++ 8.1 These changes were implemented in this version: - Metadata has been added to the ODB++ format. See 'misc/metadata.xml (Metadata)' on page 79. - A shorts file has been added to the ODB...
## ODB++ 8.0 Update 6 These changes were implemented in this version: - Section on layer types to support embedded resistors and capacitors added in Product Model Entities. See 'Layer Subtypes' on ...
## ODB++ 8.0 Update 5 These changes were implemented in this version: - Maximum value for .z0impedance changed from 0.5 to 10000. See 'ODB++ System Attributes - Alphabetical List' on page 215. - Def...
## ODB++ 8.0 Update 4 These changes were implemented in this version: - Parameter descriptions for comp\_num and toep\_num corrected, and clarification added to fill\_size for toeprint section. See...
## ODB++ 8.0 Update 3 These changes were implemented in this version: - UNIT\_TYPE of RESISTIVITY requires a UNITS value. - Two new UNITS values available when UNIT\_TYPE=RESISTIVITY-OHM and NANO\_O...
## ODB++ 8.0 Update 2 These changes were implemented in this version: - Improved the netlist example to include the use of 'ld'. - See 'cadnet/netlist (cadnet)' on page 135. - Corrected the syntax f...
## ODB++ 8.0 Update 1 These changes were implemented in this version: - Default color for layer display in the layer list is 0, indicating no preference. - See the COLOR field in 'Fields in the LAYE...
## ODB++ 8.0 These changes were implemented in this version: - Attributes are divided according to area: DFM, Product, or Process. The Process attributes are further classified as Fab, Assem, Test, ...
## File System The ODB++ format uses a standard file system structure. A product model stored in the ODB++ format is represented by an independent and self-contained directory tree. This provides the...
## Legal Entity Names The names of these ODB++ entities must comply with the rules for legal entity names: product model, step, layer, symbol, and attribute. - The length of an entity name must not ...
## Units of Measurement ODB++ files can contain an indication of the units of measurement used in the file. Unlike traditional CAM formats such as Gerber, ODB++ format represents a complete product ...
## Files that Must Contain the UNITS Directive | File Name | Path ...
## How Measurements Are Stored According to the unit of measurement selected, data is stored in these units: | Type of Data | Metric (UNITS=MM) ...
## How the UNITS Directive Specifies Units of Measurement | Location of UNITS Directive | Scope | E...
## ODB++ Attributes Attributes in the ODB++ format provide a flexible way to assign product related and process related information to ODB++ entities. The use of attributes by the ODB++ format has be...
## Attribute Classes At the highest level, attributes within the ODB++ format are divided into these classes: DFM Analysis, Product, and Process. - DFM Analysis attributes - Used to enable or enha...
## Attribute Value Assignment You can assign system attributes and user-defined attributes to ODB++ entities. For some entities, attributes are assigned using an attrlist file. For some entities, att...
## Attrlist Files For some entities, an attrlist file is placed under the entity, containing a list of attribute names and values. For example, this attrlist file assigns attributes to the layer name...
## Lookup Tables For entities for which multiple entities are defined in the same file-such as features, components, or nets-each entity definition line can contain attribute assignments for the enti...
## Unique ID The ODB++ format supports the permanent reference of entities through the use of indices for unique IDs. The unique ID is optional, but once assigned, is never changed, and no other enti...
## Format Definition All files in the ODB++ format are ASCII files. In all files, the hash (#) character specifies a comment. Lines that start with this character should be ignored, and are only use...
## Extensible Content Third parties are free to place additional content in the ODB++ file structure. Third parties are not constrained to using ASCII format, and are free to use encrypted or non-enc...
## Large File Compression One of the reasons vendors have chosen binary data in the past was the need to conserve disk space. Modern compression techniques provide excellent compression ratios, espec...
## Structured Text Files Many text files in ODB++ format contain structured text. The main advantages of this file type is readability. The user can open a file and understand its contents without ne...
## Line Record Text Files ``` X_DATUM=0.3 ``` ``` LAYER { ROW=1 CONTEXT=BOARD TYPE=COMPONENT NAME=COMP_+_TOP POLARITY=POSITIVE START_NAME= END_NAME= OLD_NAME= ADD_TYPE=MICRO_VIA COLOR=606090 } ``` ...
## Example of a Line Record Text File ``` # #Feature symbol names # $0 r50 $1 r70 $2 r80 $3 r93 $4 ths80x60x0x4x15 # #Feature attribute names # @0 .geometry @1 .pad_usage # #Feature attribute text st...
## Coordinates From ODB++ format v8.0, the UNITS directive must be present in every file that contains coordinates or measurements. In ODB++ format v7.x, the units directive described the units appl...
## Rotation and Mirroring All angles are defined by a positive value between 0 and 360 degrees. These are the rules for rotation and mirroring. - Feature pads can be rotated. Rotation is expressed...
## Symbols Symbols define a wide variety of shapes that are mostly used to represent pads. | Standard Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
## Standard Symbols Standard symbols are rendered dynamically from their names. They do not require that a graphic symbol entity be saved. They are round, square, or parametric shapes. The names of ...
## s\_ths200x180x15x5x10xr20 - s\_ths - Symbol name prefix. - 200, 180, 15, 5, 10, r20 - Parameter values presented in the required order. Note - When specifying a fractional symbol size, the separ...
## User-Defined Symbols User-defined symbols have a full graphic description stored in features files in the product model symbols directory. A user-defined symbol can contain any number of features,...
## Lines and Arcs Drawn with Symbols Lines and arcs are created by a symbol and two points-a start point and an end point. Lines and arcs are drawn by dragging the symbol by its center along a line o...
## Surfaces A surface is a feature that represents a legal contour. A surface has these properties: - The islands of a contour do not overlap. - Holes inside islands do not intersect. - Islands and...
## Geometric Entities The ODB++ format uses geometric primitives called features to describe product model geometry. Features are stored in the feature containers of layers, profiles, and symbols. Th...
## Self-Intersecting Polygons (SIP) In all polygon representations, a self-intersecting polygon (SIP) is illegal. A SIP is a polygon with a boundary that intersects itself at one or more points. Pol...
## Component Variants The definition of component variants within ODB++ is based on the active BOM applied to a step of the product model. The existence of multiple variants indicates which component...
## Chapter 2 Product Model Tree An ODB++ product model is a directory containing sub-directories that represent ODB++ entities. These charts illustrate the directory hierarchy. Users can create addi...
## <product\_model\_name> This is the top level product model directory tree. These sub directories of the <product\_model\_name> directory are described: | Sub Directory | File ...
## <product\_model\_name>/steps A product model contains one or more step entities. Each step entity can containsome or all of these entities. - Layers included in the step. - Step and repeat...
## This chart represents the directory tree under each step: These files and sub directories of the <step\_name> directory are described: | Sub Directory | File | Link to Explanatio...
## <product\_model\_name>/steps/<step\_name>/ layers This chart represents the directory tree under each layer. These files of the <layer\_name> directory are described: | File ...
## Chapter 3 Product Model Entities Several ODB++ entities are defined at the product model level. For a list of mandatory files and directories, see 'File System' on page 22. | ext (Extension) . ....
## fonts (Fonts Used in Product Model) This directory is the location to store third party data files. See 'Extensible Content' on page 31. ``` └─── <product_model_name> ├─── ... ├─── ext └─── ... ...
## fonts/standard (Standard Font) This file defines the vector representation of all the characters that can be a part of a text feature in a layer. | standard (Standard Font) | standard (Standard...
## Header Section The header section consists of these lines: | Header Line | Explanation | |---------------|-----...
## Character Block A character block consists of these lines: | Character Block Line | Explanation ...
## Standard Font Characters | ! | " | # | $ | % | & | ' | ( | ) | * | + | , | |-----|-----|-----|-----|-----|-----|-----|--------|-----|-----|-----|-----| | - | . | / ...
## Example of a font file The file consists of a header containing global parameters, followed by a character block to define each character. ``` XSIZE 0.302000 YSIZE 0.302000 OFFSET 0.000000 CHAR! ...
## input (Input) This directory is the default location of files for input packages (not ODB++ files) in the product model. ``` └─── <product_model_name> ├─── ... ├─── input └─── ... ``` | matrix (...
## matrix/stackup.xml (Stackup) The stackup file contains all the material information required for the complete manufacturing process of a circuit board. It contains what was previously held in the ...
## Structure of the Stackup File The stackup file contains one optional EdaData section and any number of optional SupplierData sections. The EdaData and SupplierData sections have similar structure...
## EdaData The stackup file contains one optional EdaData section and any number of optional SupplierData sections. Figure 3-1. Stackup File - EdaData and SupplierData Sections The EdaData secti...
## Example: - Specs - A list of material specifications and impedance requirements for the stack design (1) - Stackup - Stackup representation by the design source (1) ``` <EdaData CompanyName="Val...
## SupplierData The SupplierData section represents instances of the manufacturing stackup, each with the required content determined by the supplier. This section should contain a full stackup defin...
## Example: - Specs - A list of material specifications and impedance requirements for the stack design (1) - Stackup - Stackup representation by a supplier (1) ``` <SupplierData CompanyName="BetaB...
## Specs The Specs subsection of both EdaData and SupplierData sections includes at least one instance of the Spec element. Figure 3-2. Stackup File - Spec Section Contains a list of material sp...
## Example: - Spec - Collection of materials and impedance requirements (0-n) ``` <Specs> <Spec SpecName="Valor"> ... </Specs> ``` The schema is described in the following topics: - 'StackupFile/...
## Child elements: An individual specification defining the collection of materials and impedance requirements. The Spec is selected through the use of the SpecName attribute. - Material - Material...
## Example: ``` <Spec SpecName="Valor"> <Material MaterialName="Soldermask"> ... </Material> <Material MaterialName="0.5 oz CU"> ... <Material MaterialName="Dielectric_1"> ... </Material> <Impedance ...
## Child elements: A Material specification defining a specific material, dielectric or conductor. The Material is selected through the use of the MaterialName attribute. - Dielectric - The definit...
## Example: ``` <Material MaterialName="Soldermask"> <Dielectric DielectricType="OTHER" OtherSubType="SOLDER_MASK"/> <Default_Thickness Thickness="0.5"/> </Material> <Material MaterialName="0.5 oz CU...
## Child elements: An Impedance specification defining the general impedance goal and physical characteristics. The Impedance is selected through the use of the ImplName attribute. - Single\_Ended ...
## Example: ``` <Impedance ImpName="DIFF100 ohms"> <Differential_Edge_Coupled LayerName="t04" ZoCalculatedOhms="50.8" ZDiffCalculatedOhms="101.5"> <TraceWidth TraceWidthBottom="4.1"/> <Spacing Val="8...
## Child elements: Both the EdaData and SupplierData sections include one mandatory instance of the Stackup element. Figure 3-3. Stackup File - Stackup Section The stackup representation. - Gr...
## Example: ``` <Stackup StackupName="Step_1" StackupThickness="85"> <Group GroupName="Design"> ... </Group> </Stackup ``` The schema is described in the following topics: - 'StackupFile/EdaData/St...
## Group A stackup is created from Groups. A Group is a collection of Materials in which conductor materials are tied to copper layers of the design. Each series is represented from the top of the st...
## Example: - Layer - Layer definition within the Group (1-n) ``` <Group GroupName="Design"> <Layer LayerName="top" LayerType="SIGNAL" Side="TOP"> ... </Layer> <Layer LayerName="dielectric_1" Layer...
## Example: A layer definition within the Group. - SpecRef - The list of Material and Impedance Specs, and conductor requirements for a layer (0-n) ``` <Layer LayerName="top" LayerType="SIGNAL" S...
## matrix/matrix (Matrix) The matrix is a representation of the product model in which the rows are the product model layers-sheets on which elements are drawn for plotting, drilling and routing or a...
## Fields in the STEP Array of a Matrix File These are the fields in the STEP array of the matrix file: | Field | Explanation ...
## Fields in the LAYER Array of a Matrix File These are the fields in the LAYER array of the matrix file: | Field | Explanation ...
## Fields in the LAYER Array of a Matrix File | Field | Explanation ...
## Fields in the LAYER Array of a Matrix File Each named layer MUST have a layer entity defined under the layers directory of each step in the product model, otherwise the product model might be unre...
## Fields in the LAYER Array of a Matrix File | Field | Explanation ...
## Fields in the LAYER Array of a Matrix File ...
## Fields in the LAYER Array of a Matrix File | Field | Explanation ...
## Fields in the LAYER Array of a Matrix File Therefore, blind drills or backdrills coming up from the bottom would actually start from within the matrix and end on the bottom, and the attribute .dri...
## Fields in the LAYER Array of a Matrix File | Field | Explanation ...
## Recommended Buildup The ROW element represents the position of the layers in the buildup of the board. Mask and dielectric layers related to any of the base layers should be placed above and belo...
## Layer Subtypes For some of the base layer types assigned in the TYPE field of the LAYER array of the matrix file, you can assign a layer subtype in the ADD\_LAYER field. The tables below list the ...
## Layer Subtypes for General Needs These layer subtypes support general needs in the representation of product models: | Layer Subtype ADD_LAYER | Base Type TYPE | Description ...
## Layer Subtypes to Support Backdrill and Dual Diameter Drill These layer subtypes support the possible unique needs of drill representation in product models. They are subtypes of the DRILL base ty...
## Layer Subtypes to Support Embedded Resistors and Capacitors These layer types support the unique needs of product models containing embedded resistors and embedded capacitors. They are layer subty...
## Layer Subtypes to Support Flex/Rigid Flex Manufacturing These layer types support the unique needs of Flex/Rigid Flex product models. They are subtypes of the indicated base type: | Layer Subtype...
## Layer Subtype to Support Wire Bonding This layer type supports wire bonding. It is a subtypes of the MASK base type: | Layer Subtype ADD_LAYER | Base Type TYPE | Description ...
## Example of a Matrix File Defining a Wire Bond Layer These matrix file lines define a layer containing wire bond connections. ``` LAYER { ROW=1 CONTEXT=BOARD TYPE=MASK NAME=WIRE_BOND_+_TOP POLARIT...
## Example of a Matrix File Defining Layer Subtypes for Flex/Rigid Flex Manufacturing These matrix file lines define layers with layer subtypes SILVER\_MASK, COVERLAY, PG\_FLEX, MIXED\_FLEX, AREA, an...
## misc (Miscellaneous) | These files relate to the misc entity. | | |---------------------------------------------...
## misc/attrlist (Product Model Attribute List) This file contains the values for system attributes and user-defined attributes assigned to a product model. Only attributes that have been defined are...
## Example of a product model attrlist file System attribute names begin with a dot. The attribute connector in this example is a userdefined attribute, and therefore does not begin with a dot. For a...
## misc/last\_save (Last Time Product Model Saved) This file is optional. It is written each time a save operation is performed on a product model. It records the time of the save operation. | last_...
## misc/info (Basic Product Model Information) 20141224.183210 This file records basic information about the product model. It is written each time a save operation is performed. | info (Basic Pro...
## Example of the info file UNITS=MM PRODUCT\_MODEL\_NAME=k10025\_cd2 ODB\_VERSION\_MAJOR=8 ODB\_VERSION\_MINOR=0 ODB\_SOURCE=Expedition CREATION\_DATE=20110727.091213 SAVE\_DATE=20110727.091230 SAVE...
## misc/metadata.xml (Metadata) Product description information is provided in a file named metadata.xml , stored in the misc directory of the product model. | metadata (Metadata) | metadata (Meta...
## Structure of the Metadata File A metadata file can contain several types of element. | Element | Explanation ...
## Metadata Sections The metadata is divided into sections that indicate the type of metadata. Some sections can be specified at the level of the product model, and some sections can be specified on...
## Metadata Types Each value stored in the metadata file is of one of these data types: | Type | Description ...
## Attributes of a Metadata Node Metadata is specified in node statements. It has this syntax: <node name="nnn", value="vvv", units="uuu", layer="lll", display="ddd" /> See 'Metadata Content...
## Collective Data In some cases, metadata content can represent a collection of similar data-for example, the number of components classified by type. In such a case, classify\_by elements are inclu...
## misc/sysattr.* (Attribute Definition) Attribute definition files for all attributes in the product model are stored under <product\_model\_name>/misc . They all have the same syntax. Attribu...
## BOOLEAN Attribute Definition Attributes that have values of either YES or NO. | Field | Explanation ...
## TEXT Attribute Definition ``` BOOLEAN { NAME = .string_mirrored ENTITY = FEATURE DEF = NO GROUP = Fabrication PROMPT = String Mirror } ``` Attributes that are text strings have values...
## OPTION Attribute Definition ``` TEXT { NAME = .string OPTIONS = ENTITY = FEATURE MIN_LEN = 0 MAX_LEN = 1000 GROUP = Feature DEF = PROMPT = Copper Text String } ``` Attributes that have va...
## Example In this example, option both is defined as being logically deleted. ``` OPTION { NAME=.viacap_layer PROMPT=Via Capping on Layer OPTIONS=top;bottom;both;none DELETED=NO;NO;YES;NO ENTITY=st...
## INTEGER Attribute Definition Attributes that have a numerical integer value within the range defined by the attribute definition. | Field | Explanation | |---------|-----------------...
## FLOAT Attribute Definition ``` INTEGER { NAME = .num_local_fiducials ENTITY = COMPONENT DEF = 0 MIN_VAL = 0 MAX_VAL = 20 GROUP = DFx Component PROMPT = Number Local Fiducials Required }...
## FLOAT Attribute Definition | Field | Explanation ...
## Example: UNITS directive = MM and UNITS line = MIL\_MICRON ``` FLOAT { NAME = .local_fiducial_dist ENTITY = COMPONENT MIN_VAL = 0.0 MAX_VAL = 100.0 UNITS = INCH_MM PROMPT = Search Distance ...
## Example: UNITS directive = INCH and UNITS line = MIL\_MICRON In this example, MAX\_VAL is interpreted as 100 mil (0.1 inch). The directive UNITS=INCH specifies that measurements in the file are gi...
## misc/userattr (User Attribute Definition) User-defined attributes cannot have the dot character before their name. | userattr | userattr | |-------------|------------...
## steps Steps are multi-layer entities such as a single image, an assembly panel, a fabrication panel, or a fabrication coupon. Each step contains a collection of layers. Layers are two-dimensional ...
## symbols (User-Defined Symbols) Symbols are single layer graphic entities that can be referenced from within any graphic layer in a step. ODB++ format can handle both standard symbols and user-defi...
## <symbol\_name>/attrlist (Symbol Attribute List) This file contains the values for system attributes and user-defined attributes assigned to a symbol. You can provide attrlist files at these...
## Example of an attrlist file for a Symbol ``` UNITS=INCH .out_break = no .out_scale = no .break_away = no .fill_dx = 0.100000 .fill_dy = 0.100000 .image_dx = -1.000000 .image_dy = -1.000000 connect...
## <symbol\_name>/features (Symbol Features) Each user-defined symbol has a features file to define its shape. | features (Symbol Features) | features (Symbol Features) ...
## wheels (Gerber and Tool Wheels) This directory is the location to store user files. ``` └─── <product_model_name> ├─── ... ├─── user └─── ... ``` Wheels are aperture tables used for the correct...
## <wheel\_name>/attrlist (Wheel Attribute List) This file contains the values for system attributes and user-defined attributes assigned to a wheel. You can provide attrlist files at these le...
## <wheel\_name>/dcodes (Dcodes) ``` UNITS=MM ``` comment=Mentor wheel This file lists dcodes. A dcode is a Gerber dcode number or an Excellon tool number. | dcodes | dcodes | |...
## Chapter 4 Step Entities ``` dcode10 r12 0 no_mirror dcode11 r50 0 no_mirror dcode12 r60 0 no_mirror dcode13 r10 0 no_mirror dcode14 r70 0 no_mirror dcode15 r80 0 no_mirror dcode17 r5 0 no_mirror `...
## <step\_name>/attrlist (Step Attribute List) This file contains the values for system attributes and user-defined attributes assigned to a step. You can provide attrlist files at these level...
## Example of the attrlist file In the example, comment is a user-defined attribute, so it does not begin with a dot. ``` UNITS=MM .board_thickness=50 .out_drill_full = no .out_drill_optional = no ....
## <step\_name>/boms (Bill of Materials) The boms directory of the step contains a directory for each BOM associated with the step. The name of the directory is the name of the BOM. The direct...
## <bom\_name>/bom (Bill Of Materials) The BOM file describes the Bill of Materials for a board. It is a list of the components that can be used in assembling the electronic product. | bom ...
## HEADER Section The header section of the bom file contains these parameters: | Parameter | Description | |-------------|------------------------------------------| ...
## DESC\_ALIASES Section The DESC\_ALIASES section of the bom file provides aliases for CPN and MPN descriptions to enable terms to be displayed in the language of the product model creator. | Param...
## RD\_CPN Section The RD\_CPN section of the bom file lists the Reference Designators and their matching Customer Part Numbers: A LNFILE entry is saved for each REF and CPN. | Parameter | Descri...
## CPN\_MPN Section The CPN\_MPN section of the bom file lists Customer Parts and their matching Manufacturer Parts A LNFILE entry is saved for each CPN, MPN, and VND. | Parameter | Description ...
## CP Section The CP section of the bom file lists Customer Part Numbers and their descriptions. A LNFILE entry is saved for each CPN, IPN, DSC, and PKG. | Parameter | Description ...
# Reference Descriptors and matching Customer Parts HEADER BRD REV HEADER\_END DESC\_ALIASES LANG fr INDEX 1 CPN Cout CPN Cost INDEX 1 MPN Benefice MPN Profit Margin DESC\_ALIASES\_END ...
# Customer Parts and Matching Manufacturer Parts CPN\_MPN CPN 004-020-101 LNFILE 5 Rev14.v1 VPL\_MPN VPL\_VND TOYOCOM MPN TQC-216C-6R LNFILE 5 Rev14.v1 VND TOYOCOM LNFILE 5 Rev14.v1 QLF 0 C...
# Customer Parts and Matching Manufacturer Parts > ## <step\_name>/eda (Electronic Design Automation) The files directory contains the source files that generated the bom entity (BOM and AVL). ...
# Customer Parts and Matching Manufacturer Parts > ## eda/data (EDA Data) This file contains information that is read from the EDA system directly. | data | data ...
# Customer Parts and Matching Manufacturer Parts > ## This is an example of an eda data file: ``` # HDR Mentor Boardstation database UNITS=MM LYR sst sst+1 sigt sig2 sig3 sig4 sig7 sig8 sig9 sigb smt...
# Customer Parts and Matching Manufacturer Parts > ## HDR - File Header Record This record contains the name of the EDA system that was the source of the data. HDR <source> | HDR Parameter |...
# Customer Parts and Matching Manufacturer Parts > ## LYR - Layer Names Record This record contains the names of the layers that are referenced in FID records. See 'FID - Feature ID Record' on page ...
# Customer Parts and Matching Manufacturer Parts > ## PRP - Property Record A property is a value associated with EDA entities-board, net, package, feature-that specifies some of their characteristic...
# Customer Parts and Matching Manufacturer Parts > ## @ and & - Net Attribute Lookup Table Records This section of the file contains a table of net attribute names and a table of all net attribut...
# Customer Parts and Matching Manufacturer Parts > ## NET - Electrical Net Record This record contains a start record of an electrical net. Each net consists of one NET line and 0 or more SNT records...
# Customer Parts and Matching Manufacturer Parts > ## SNT- Subnet Record This record defines a portion of a net. The portion can be one of these types of subnet: - Toeprint - A connection of a compo...
# Customer Parts and Matching Manufacturer Parts > ## Structure for toeprint: SNT TOP <side> <comp\_num> <toep\_num> | SNT TOP Field | Explanation ...
# Customer Parts and Matching Manufacturer Parts > ## Structure for trace: SNT TRC | SNT VIA Field | Explanation | |-----------------|-------------------------------------| ...
# Customer Parts and Matching Manufacturer Parts > ## Structure for plane: SNT PLN <fill\_type> <cutout\_type> <fill\_size> | SNT PLN Field | Explanation ...
# Customer Parts and Matching Manufacturer Parts > ## FID - Feature ID Record This record contains a link to the feature file of layer number <lyr\_num>. The record is used to connect subnets a...
# Customer Parts and Matching Manufacturer Parts > ## PKG - Package Record This record contains a definition of a package that is the generic shape of a component. Each component refers to a package....
# Customer Parts and Matching Manufacturer Parts > ## PIN - Pin Record This record contains a definition of a pin that belongs to a package. Each Pin record is followed by at least one outline recor...
# Customer Parts and Matching Manufacturer Parts > ## FGR - Feature Group Record This record contains the definition of a group of related features-for example, the strokes of a text record. Each FGR...
# Customer Parts and Matching Manufacturer Parts > ## RC, CR, SQ, CT, OB, OS, OC, OE, CE - Outline Records Outline records must follow a PKG or PIN record. They describe the shape of the package or p...
# Customer Parts and Matching Manufacturer Parts > ## eda/shorts (Electrical Intention Short Net) This file contains information that is read from the EDA system directly. | shorts (Electrical Inten...
# Customer Parts and Matching Manufacturer Parts > ## Example of a shorts file: ``` # UNITS=MM LYR sst sigt sig2 sig3 sig4 sig7 sig8 sig9 sigb smt smb drill spt ssb spb pg6 pg5 # SRT 1 SRT 1 7;ID=20 ...
# Customer Parts and Matching Manufacturer Parts > ## LYR - Layer Names in the Shorts File This record contains the names of the layers that are referenced in FID records. This is the format of the ...
# Customer Parts and Matching Manufacturer Parts > ## FID-Feature ID Record in the Shorts File This record contains a link to the feature file of layer number <lyr\_num>. The record is used to ...
# Customer Parts and Matching Manufacturer Parts > ## SRT - Electrical Intention Short Net Record This record is a start record for defining an intentional short. Each short definition contains at l...
# Customer Parts and Matching Manufacturer Parts > ## Example of Multiple Nets Shorted with a Copper Feature With a Net Name This is an example of multiple nets shorted together, where the copper fea...
# Customer Parts and Matching Manufacturer Parts > ## Example of Multiple Nets Shorted With a Copper Feature Without a Net Name This is an example of multiple nets shorted together, where the copper ...
# Customer Parts and Matching Manufacturer Parts > ## eda/hdi\_netlist (HDI Netlist) A netlist defining wire bond connection is defined in this file. | hdi_netlist | hdi_netlist | |-----------...
# Customer Parts and Matching Manufacturer Parts > ## HDI\_NETLIST\_DATABASE Array Structure The file contains a single HDI\_NETLIST\_DATABASE record containing common information. | Parameter | E...
# Customer Parts and Matching Manufacturer Parts > ## HDI\_PACKAGE array structure The file contains a HDI\_PACKAGE records for each component involved in the netlist. These components are specified ...
# Customer Parts and Matching Manufacturer Parts > ## Example of the HDI\_PACKAGE section: ``` HDI_PACKAGE { name=U4 ref_des=U4 type=DIE } ```
# Customer Parts and Matching Manufacturer Parts > ## HDI\_NET\_POINT Array Structure The file contains multiple HDI\_NET\_POINT records for all pins of source and destination components connected by...
# Customer Parts and Matching Manufacturer Parts > ## HDI\_NET\_BRIDGE array structure The netlist file can contain an optional section for a direct wire bond connection in the same copper layer. No ...
# Customer Parts and Matching Manufacturer Parts > ## <step\_name>/impedance.xml (Impedance) ``` HDI_NET_BRIDGE { net=VCCEL_L 1=0.37 y1=0.54 x2=0.385 y2=0.544 } ``` The optional impedance fil...
# Customer Parts and Matching Manufacturer Parts > ## Descriptor The Impedances element contains instances of the Descriptor section. Figure 4-1. Impedance File A list of impedance requirements ...
# Customer Parts and Matching Manufacturer Parts > ## Child elements: - RequiredImpedance - The required impedance values (0-1) - OriginalTraceWidth - The original trace width for the required impeda...
# Customer Parts and Matching Manufacturer Parts > ## Example: ``` <Impedances Version="8.1" MaxImpIdValUsed="3"> <Descriptor Id="1" TraceLayerName="t10"> <RequiredImpedance ValOhms="50" PlusVal="5" ...
# Customer Parts and Matching Manufacturer Parts > ## <step\_name>/layers Layers express physical board layers, and also mask layers, NC drill and rout layers, and miscellaneous drawings. See ...
# Customer Parts and Matching Manufacturer Parts > ## <step\_name>/netlists These files are related to the netlists entity. | cadnet/netlist (cadnet) . . . . . . . . . . . . . . . . . . . . . ...
# Customer Parts and Matching Manufacturer Parts > ## cadnet/netlist (cadnet) This file represents a netlist as it was read from an external CAD system. A netlist is a collection of nets, each one re...
# Customer Parts and Matching Manufacturer Parts > ## H optimize <y|n> [staggered <y|n>] The first line of the file is the header line. It has this syntax: | Field | Explanation ...
# Customer Parts and Matching Manufacturer Parts > ## List of Nets The net section of the file contains lines with this syntax: $<serial\_num> <net\_name> | Field | Explanation ...
# Customer Parts and Matching Manufacturer Parts > ## List of Net Points The net point section of the file lists the net points. It contains lines of this syntax: ``` <net_num> <radius> <x> <y> <sid...
# Customer Parts and Matching Manufacturer Parts > ## List of Net Points | Field | Explanation ...
# Customer Parts and Matching Manufacturer Parts > ## List of Net Points If the ld field is missing, the BOTTOM layer UID is assumed. • B (both) -Indicates net points accessible from TOP and BOTTOM...
# Customer Parts and Matching Manufacturer Parts > ## List of Net Points ...
# Customer Parts and Matching Manufacturer Parts > ## List of Net Points | Field | Explanation ...
# Customer Parts and Matching Manufacturer Parts > ## List of Net Points | Field | Explanation ...
# Customer Parts and Matching Manufacturer Parts > ## Example of a cadnet netlist file ``` UNITS=MM H optimize n staggered n $0 &1N1096 $1 &1N1526 $2 &1N289 $3 &1N312 $4 &1N338 $5 &1N340 $6 $NONE$ .....
# Customer Parts and Matching Manufacturer Parts > ## refnet/netlist (Reference) This file describes the reference netlist for the step. A reference netlist describes net connectivity as it should be...
# Customer Parts and Matching Manufacturer Parts > ## <step\_name>/profile (Outline Shape of Step) The step profile defines the outline shape of the step. It is required by many operations. | ...
# Customer Parts and Matching Manufacturer Parts > ## Example of a Step Profile File ``` UNITS=MM ID=58 # #Num features # F 1 # #Layer features # S P 0 OB -49.9341975 -64.2563075 I OS -49.9341975 -0....
# Customer Parts and Matching Manufacturer Parts > ## <step\_name>/stephdr (Step Header) This file contains data that is common to the whole step. This includes the step and repeat array for ne...
# Customer Parts and Matching Manufacturer Parts > ## These are the fields in the STEP-REPEAT array: | Field | Explanation ...
# Customer Parts and Matching Manufacturer Parts > ## Example of the stephdr file The file consists of general fields, and an array of STEP-REPEAT records that exists only if there are nested steps. ...
# Customer Parts and Matching Manufacturer Parts > ## <step\_name>/zones (Matrix Broken Into Sections) The zones file is optional. When the file exists, the content provides a cross-sectional v...
# Customer Parts and Matching Manufacturer Parts > ## ZONE - Start Record Start zone record: ZONE <name>;zone\_UID Defines the start of a zone by providing a name by which the zone will be ref...
# Customer Parts and Matching Manufacturer Parts > ## LYR - Layer Record Layer record: LYR <layer\_UIDs> Lists the layers that belong to the zone. | LYR Record Parameter | Explanation ...
# Customer Parts and Matching Manufacturer Parts > ## PRP - Properties Records Properties Record: PRP <name> <value> <units> <layer\_UIDs> Optional. Defines properties of spe...
# Customer Parts and Matching Manufacturer Parts > ## S - Surface Defining the Zone Area The records following the LYR record, and possibly the optional PRP records, define a zone as a single surface...
# Customer Parts and Matching Manufacturer Parts > ## Example of a zones file ``` UNITS=INCH ID=2411100 # # Zone 1 # ZONE area1;UID=2411111 LYR 23 45 78 97 PRP copper_area 2.23 INCH 23 PRP copper_are...
# Customer Parts and Matching Manufacturer Parts > ## Chapter 5 Layer Entities Product model layers can contain graphics, properties and annotation. Layers represent physical board layers, NC drills ...
# Customer Parts and Matching Manufacturer Parts > ## <layer\_name>/attrlist (Layer Attribute List) This file contains the values for system attributes and user-defined attributes of a layer. ...
# Customer Parts and Matching Manufacturer Parts > ## <layer\_name>/components (Components) Each layer of type component has a unique name: comp\_+\_top or comp\_+\_bot. There can be only one o...
# Customer Parts and Matching Manufacturer Parts > ## Example of a component file: ``` # UNITS=INCH # #Component attribute names # @0 .no_pop @1 .comp_ignore @2 .desc1 @3 .comp_mount_type @4 .comp_he...
# Customer Parts and Matching Manufacturer Parts > ## @ and & - Component Attribute Lookup Table This section of the component file contains a table of component attribute names and a table of al...
# Customer Parts and Matching Manufacturer Parts > ## CMP - Component Record This record contains the definition of a component. Each CMP line is followed by 0 or more property (PRP) records, and 0 o...
# Customer Parts and Matching Manufacturer Parts > ## CMP - Component Record | Field | Explanation ...
# Customer Parts and Matching Manufacturer Parts > ## CMP - Component Record ...
# Customer Parts and Matching Manufacturer Parts > ## PRP - Component Property Record This record represents a property of the component. A property consists of a name, a string value, and 0 or more ...
# Customer Parts and Matching Manufacturer Parts > ## TOP - Component Toeprint Record This record contains a definition of a toeprint of a component. This is the format of the TOP record: TOP <p...
# Customer Parts and Matching Manufacturer Parts > ## BOM Description Records The BOM DATA section of a component file contains BOM information for components. | Parameter | Description ...
# Customer Parts and Matching Manufacturer Parts > ## Example of Alternate Parts This is an example of alternate parts defined for the same CPN. The first is chosen, and the third is not qualified. T...
# Customer Parts and Matching Manufacturer Parts > ## <layer\_name>/dimensions (Dimensions) Dimensions that have been added to a layer to indicate measurements of objects on the layer are store...
# Customer Parts and Matching Manufacturer Parts > ## Example of a Dimensions File: ``` VERSION=1 UNITS=INCH PARAMETERS { ID=0 LINE_WIDTH=0.01 POST_DECIMAL_DIST=3 POST_DECIMAL_POS=3 POST_DECIMAL_ANGL...
# Customer Parts and Matching Manufacturer Parts > ## Global Parameters for Dimensions These are the global parameters. | Field | Explanation ...
# Customer Parts and Matching Manufacturer Parts > ## PARAMETERS Array Structure This is the array structure of each parameter set. | Field | Explanation ...
# Customer Parts and Matching Manufacturer Parts > ## DIMENSION Array Structure This is the dimension array structure. | Field | Explanation ...
# Customer Parts and Matching Manufacturer Parts > ## PAPER Array Structure This is the array structure for the Frontline paper definitions. It is included in the PARAMETERS array. | Field | E...
# Customer Parts and Matching Manufacturer Parts > ## TEXT Array Structure The TEXT array structure is not relevant to the CENTER dimension. It is included in the DIMENSIONS array. | Field | Ex...
# Customer Parts and Matching Manufacturer Parts > ## <layer\_name>/features (Graphic Features) The features file contains definitions of graphic features. | features | features ...
# Customer Parts and Matching Manufacturer Parts > ## Example of a features file: ``` UNITS=MM ID=216 # #Num Features # F 1406 # #Feature symbol names # $0 r120 $1 rect20x60 M $2 rect3x5 I $3 punch_t...
# Customer Parts and Matching Manufacturer Parts > ## Example of a features file: | Section | Description ...
# Customer Parts and Matching Manufacturer Parts > ## UNITS - Measurement Units Features and coordinates are saved in the units in which they were created, to avoid loss of precision due to rounding....
# Customer Parts and Matching Manufacturer Parts > ## Example of Interpretation of Symbol Dimensions ``` # UNITS=MM # #Feature symbol names # $0 r120 $1 rect20x60 M $2 rect3x5 I $3 punch_target ``` ...
# Customer Parts and Matching Manufacturer Parts > ## F - Number of Features (Optional) This file can contain a unique ID. This is the format of the line: ID=<id>. See 'Unique ID' on page 30....
# Customer Parts and Matching Manufacturer Parts > ## $ - Feature Symbol Names Section This section lists the symbols used to construct lines, pads, or arcs defined in the file. It contains the names...
# Customer Parts and Matching Manufacturer Parts > ## @ and & - Feature Attribute Lookup Table ``` # #Feature symbol names # $0 r120 $1 rect20x60 M $2 rect3x5 I $3 punch_target ``` This section...
# Customer Parts and Matching Manufacturer Parts > ## Example of a Feature Attribute Lookup Table This is an example of a feature attribute lookup table, and a feature definition record that assigns ...
# Customer Parts and Matching Manufacturer Parts > ## L - Line Records These records define a line. This is the format of a line record: L <xs> <ys> <xe> <ye> <sym\_num&g...
# Customer Parts and Matching Manufacturer Parts > ## P - Pad Records L 5.15 0.35 5.125 0.325 0 P 0 These lines define a pad. This is the format of a line record: P <x> <y> <apt\_d...
# Customer Parts and Matching Manufacturer Parts > ## P - Pad Records | Pad Parameter | Explanation ...
# Customer Parts and Matching Manufacturer Parts > ## P - Pad Records ...
# Customer Parts and Matching Manufacturer Parts > ## P - Pad Records | Pad Parameter | Explanation ...
# Customer Parts and Matching Manufacturer Parts > ## Example of Pad Records in a Features File Special pad const\_1 at location x=1.0, y=2.0 positive, with dcode 4, is used as an example for differe...
# Customer Parts and Matching Manufacturer Parts > ## A - Arc Records These lines define an arc. This is the format of an arc definition record: A <xs> <ys> <xe> <ye> <xc...
# Customer Parts and Matching Manufacturer Parts > ## T - Text Records A 1.49401033 2.53683297 0.8389936 2.48563819 1.17858858 2.35659203 2 P 0 Y These lines define text. This is the format of a t...
# Customer Parts and Matching Manufacturer Parts > ## T - Text Records | Text Parameter | Explanation ...
# Customer Parts and Matching Manufacturer Parts > ## T - Text Records This value is expressed as: 0|1|2|3|4|5|6|7|8<rotation>|9<rotation> If the first nu...
# Customer Parts and Matching Manufacturer Parts > ## T - Text Records | Text Parameter | Explanation ...
# Customer Parts and Matching Manufacturer Parts > ## Dynamic Text Variables A text string can include dynamic text variables that change textual value according to status or condition. For example, ...
# Customer Parts and Matching Manufacturer Parts > ## Example of a Text Record in a Features File ``` #Feature attribute names # #Layer features # T 4.033375 6.377506 standard P 8 0 0.2 0.2 2.00000 '...
# Customer Parts and Matching Manufacturer Parts > ## B - Barcode Records These records define a barcode. This is the format of the barcode definition line: B <x> <y> <barcode> &l...
# Customer Parts and Matching Manufacturer Parts > ## B - Barcode Records | Barcode Parameter | Explanation ...
# Customer Parts and Matching Manufacturer Parts > ## B - Barcode Records ...
# Customer Parts and Matching Manufacturer Parts > ## B - Barcode Records | Barcode Parameter | Explanation ...
# Customer Parts and Matching Manufacturer Parts > ## S - Surface Records ``` UNITS=INCH # #Feature attribute names # @0 .nomenclature # #Layer features # B -1.73493967 0.25060236 UPC39 standard P 8 ...
# Customer Parts and Matching Manufacturer Parts > ## S Records These are the parameters for the S line: | S Parameter | Explanation ...
# Customer Parts and Matching Manufacturer Parts > ## OB Records These are the parameters of the OB (begin) line: | OB Parameter | Explanation | |----------------|-------------...
# Customer Parts and Matching Manufacturer Parts > ## OS Records These are the parameters of the OS (segment) lines: | OS Parameter | Explanation ...
# Customer Parts and Matching Manufacturer Parts > ## OC Records These are the parameters of the OC (arc) lines: | OC Parameter | Explanation | ...
# Customer Parts and Matching Manufacturer Parts > ## Example of Surface Records in the Feature File ``` S P 0 OB 5.36 3.525 I OS 5.36 3.809 OS 5.501 3.809 OS 5.501 3.735 OS 5.431 3.735 OS 5.431 3.52...
# Customer Parts and Matching Manufacturer Parts > ## <layer\_name>/notes (Electronic Notes) The notes file contains notes added by the user. | notes (Electronic Notes) | notes (Electronic N...
# Customer Parts and Matching Manufacturer Parts > ## Example of a notes file 866467418,moshik,2.03807,-1.22818,,,,,,First line\nSecond line Each line in the notes file has this format: <time>...
# Customer Parts and Matching Manufacturer Parts > ## <layer\_name>/profile (Outline Shape of Layer) The layer profile is defined as a multi-island contour according to ODB++ contour definition...
# Customer Parts and Matching Manufacturer Parts > ## Example of a Layer Profile File ``` UNITS=INCH ID=58 # #Num features # F 1 # #Layer features # S P 0 OB 5.688950787402 7.475950787402 I OS 5.6889...
# Customer Parts and Matching Manufacturer Parts > ## <layer\_name>/tools (Drill Tools) This file contains the tools table of a drill layer, initially created during input. | tools (Drill Tool...
# Customer Parts and Matching Manufacturer Parts > ## Global Parameters for Drill Tools These are the global parameters. | Field | Explanation ...
# Customer Parts and Matching Manufacturer Parts > ## Tools array structure This is the tools array structure. | Field | Explanation ...
# Customer Parts and Matching Manufacturer Parts > ## Example of a tools file ``` UNITS=INCH THICKNESS=62.5 USER_PARAMS=method25 TOOLS { NUM=1 TYPE=VIA TYPE2=STANDARD MIN_TOL=0 MAX_TOL=0 BIT= FINISH_...
# Customer Parts and Matching Manufacturer Parts > ## Appendix A Standard ODB++ Symbols A symbol is one of the geometric primitives supported by ODB++ described here, or a combination of them. They a...
# Customer Parts and Matching Manufacturer Parts > ## Basic Standard Symbols These are the basic standard symbols. | Symbol Name | Example | Parameters | |---------------|----------...
# Customer Parts and Matching Manufacturer Parts > ## Basic Standard Symbols | Symbol Name | Example | Parameters ...
# Customer Parts and Matching Manufacturer Parts > ## Basic Standard Symbols | Symbol Name | Example | Parameters ...
# Customer Parts and Matching Manufacturer Parts > ## Symbols Suitable for Solder Stencil Design Several symbols were added to fulfill the requirements for effective stencil design manufacture. Thes...
# Customer Parts and Matching Manufacturer Parts > ## Other Symbol Information | Symbol topics are discussed. ...
# Customer Parts and Matching Manufacturer Parts > ## Rotated Standard Symbols Prior to ODB++ version 7.0, pads and text could be rotated only in increments of 90 degrees. Angles other than 0, 90, 18...
# Customer Parts and Matching Manufacturer Parts > ## Rounded/Chamfered Rectangles The corners of rounded/chamfered rectangles are specified in ascending order counterclockwise, starting from the top...
# Customer Parts and Matching Manufacturer Parts > ## Appendix B System Attributes The standard Octagon symbol corner size is the distance between the bounding box corner and the vertex. These sy...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List These are the system attributes. | Attribute | Type | Entity | D...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes - Alphabetical List | Attribute | Type | Entity | Description ...
# Customer Parts and Matching Manufacturer Parts > ## ODB++ System Attributes by Class ODB++ system attributes are listed here by class. For each class, the name of the sysattr file is indicated, in ...
# Customer Parts and Matching Manufacturer Parts > ## Product (sysattr) These attributes support the product.
# Customer Parts and Matching Manufacturer Parts > ## Table B-1. ODB++ Product Attributes | ODB++ Product Attributes | |----------------------------------------| | .all_eda_layers ...
# Customer Parts and Matching Manufacturer Parts > ## DFM (sysattr.dfm) These attributes support Design For Manufacture (DFM). Table B-2. ODB++ DFM Attributes | ODB++ DFMAttributes | |--------...
# Customer Parts and Matching Manufacturer Parts > ## Fabrication (sysattr.fab) These attributes support fabrication. Table B-3. ODB++ Fabrication Attributes | ODB++ Fabrication Attributes | |--...
# Customer Parts and Matching Manufacturer Parts > ## Assembly (sysattr.assy) These attributes support assembly. Table B-4. ODB++ Assembly Attributes | ODB++ Assembly Attributes | |--------------...
# Customer Parts and Matching Manufacturer Parts > ## Test (sysattr.test) | ODB++ Assembly Attributes | |-----------------------------| | .spo_w_mode | | .spo_w_val ...
# Customer Parts and Matching Manufacturer Parts > ## Table B-5. ODB++ Test Attributes | ODB++ Test Attributes | |-------------------------| | .board_mark | | .hp3070_comment | ...
# Customer Parts and Matching Manufacturer Parts > ## Table B-6. ODB++ Generic Attributes These are generic attributes. | ODB++ Generic Attributes | |----------------------------| | .color ...
# Customer Parts and Matching Manufacturer Parts > ## Appendix C Standard Font This section contains the font definition for the font Standard used for ODB++ text. The file is not part of the ODB++ f...
# Customer Parts and Matching Manufacturer Parts > ## Appendix C Standard Font ``` LINE -0.100000 0.150000 -0.050000 0.200000 P R 0.012000 LINE -0.050000 0.200000 0.050000 0.200000 P R 0.012000 LINE ...
# Customer Parts and Matching Manufacturer Parts > ## Appendix C Standard Font ``` LINE 0.100000 0.150000 0.000000 0.050000 P R 0.012000 LINE 0.000000 0.050000 0.000000 0.000000 P R 0.012000 LINE 0.0...
# Customer Parts and Matching Manufacturer Parts > ## CHAR E LINE -0.100000 0.200000 0.100000 0.200000 P R 0.012000 ``` LINE -0.100000 -0.100000 0.100000 -0.100000 P R 0.012000 LINE -0.100000 0.0500...
# Customer Parts and Matching Manufacturer Parts > ## CHAR E LINE -0.050000 0.050000 -0.100000 0.100000 P R 0.012000 LINE -0.100000 0.100000 -0.100000 0.150000 P R 0.012000 LINE -0.100000 0.150000 -0...
# Customer Parts and Matching Manufacturer Parts > ## CHAR E ``` CHAR e LINE 0.050000 -0.100000 -0.050000 -0.100000 P R 0.012000 LINE -0.050000 -0.100000 -0.100000 -0.050000 P R 0.012000 LINE -0.1000...
# Customer Parts and Matching Manufacturer Parts > ## ECHAR ``` CHAR l LINE -0.050000 0.200000 0.000000 0.200000 P R 0.012000 LINE 0.000000 0.200000 0.000000 -0.050000 P R 0.012000 LINE 0.000000 -0.0...
# Customer Parts and Matching Manufacturer Parts > ## ECHAR ``` LINE -0.100000 0.100000 0.100000 0.100000 P R 0.012000 LINE 0.100000 0.100000 -0.100000 -0.100000 P R 0.012000 LINE -0.100000 -0.100000...
# Customer Parts and Matching Manufacturer Parts > ## Appendix D Metadata Content, Example, and Schema Product model metadata can be supplied in a metadata.xml file. See 'misc/metadata.xml (Metadata...
# Customer Parts and Matching Manufacturer Parts > ## Metadata Content These node tags are supported by ODB++, and cannot be modified by a user. The tags are placed in the appropriate section of the ...
# Customer Parts and Matching Manufacturer Parts > ## Header Metadata Section These are the tags in the header section. Table D-1. Metadata Content - Header Section | Name | Des...
# Customer Parts and Matching Manufacturer Parts > ## Requirements Metadata Section These are the tags in the requirements section. Table D-2. Metadata Content - Requirements | Name ...
# Customer Parts and Matching Manufacturer Parts > ## Requirements Metadata Section | Name | Description ...
# Customer Parts and Matching Manufacturer Parts > ## Requirements Metadata Section | Name | Description ...
# Customer Parts and Matching Manufacturer Parts > ## Requirements Metadata Section | Name | Description ...
# Customer Parts and Matching Manufacturer Parts > ## Manufacturing Metadata Section These are the tags in the manufacturing section. Table D-3. Metadata Content - Manufacturing | Name ...
# Customer Parts and Matching Manufacturer Parts > ## Manufacturing Metadata Section | Name | Description ...
# Customer Parts and Matching Manufacturer Parts > ## Manufacturing Metadata Section | Name | Description ...
# Customer Parts and Matching Manufacturer Parts > ## Manufacturing Metadata Section | Name | Description ...
# Customer Parts and Matching Manufacturer Parts > ## Assembly Metadata Section These are the tags in the requirements section. Table D-4. Metadata Content - Assembly | Name | De...
# Customer Parts and Matching Manufacturer Parts > ## Final Metadata Section These are the tags in the final section. Table D-5. Metadata Content - Final | Name | Descrip...
# Customer Parts and Matching Manufacturer Parts > ## Metadata Example This is an example of a metedata.xml file. ``` <metadata> <Header description="General Information" > <node display="Buried Res...
# Customer Parts and Matching Manufacturer Parts > ## Metadata Example ``` <classify_by display="Pitch" units="MM" value="0.5" name="pitch" /> </classify_by> <classify_by display="CAD Package" value=...
# Customer Parts and Matching Manufacturer Parts > ## Metadata Schema This is the metadata schema. ``` <?xml version="1.0" encoding="utf-8" ?> <metadataSchema description=""> <metadataSection intern...
# Customer Parts and Matching Manufacturer Parts > ## Metadata Schema ``` description="Defines part number of job"/> <metadataAttr internalName="revision" displayName="Revision" entityLevel="JOB" typ...
# Customer Parts and Matching Manufacturer Parts > ## Metadata Schema ``` red"/> <metadataAttr internalName="flammability_rating_standard" displayName="Flammability Rating Standard" entityLevel="JOB"...
# Customer Parts and Matching Manufacturer Parts > ## Metadata Schema ``` callback="ODBAttr" description="Defines maximum tolerance for layer to layer registration of copper layers"/> <metadataAttr i...
# Customer Parts and Matching Manufacturer Parts > ## Metadata Schema ``` displayName="Min Soldermask Clearance for SMD Pads" entityLevel="STEP" type="float" unitsType="Distance" unitsSize="MIL_MICRO...
# Customer Parts and Matching Manufacturer Parts > ## Metadata Schema ``` callback="ODBAttr" description="Defines required Cu thickness in barrel of buried via holes"/> <metadataAttr internalName="ba...
# Customer Parts and Matching Manufacturer Parts > ## Metadata Schema ``` the production lot number for a board"/> <metadataAttr internalName="mfg_id_stamp" displayName="Manufacturer Identification S...
# Customer Parts and Matching Manufacturer Parts > ## Metadata Schema ``` unitsType="Distance" unitsSize="MIL_MICRON" callback="Function" description="Smallest via diameter"/> <metadataAttr internalN...
# Customer Parts and Matching Manufacturer Parts > ## Metadata Schema ``` <metadataAttr internalName="component_count" displayName="Components per Step" entityLevel="STEP" type="Integer" callback="Co...
# Customer Parts and Matching Manufacturer Parts > ## Appendix E Stackup Schema This appendix describes the elements, their related sub-elements, and the relevant attributes of the stackup file. Each...
# Customer Parts and Matching Manufacturer Parts > ## Appendix E Stackup Schema | StackupFile. . . . . . . . . . . . . . . . . . . . . . . . . . . ...
# Customer Parts and Matching Manufacturer Parts > ## Appendix E Stackup Schema . . . ...
# Customer Parts and Matching Manufacturer Parts > ## Appendix E Stackup Schema | CoplanarSpacing . . . . . . . . . . . . . . . . . . . . . . . . . ....
# Customer Parts and Matching Manufacturer Parts > ## Appendix E Stackup Schema | 385 | | StackupFile/EdaData/Stackup/Group . . . . . . . . . . . . . . . . . ...
# Customer Parts and Matching Manufacturer Parts > ## Appendix E Stackup Schema | StackupFile/SupplierData/Specs/Spec/Material/Dielectric/Properties/Property . . . . . ...
# Customer Parts and Matching Manufacturer Parts > ## Appendix E Stackup Schema . . . . . . . . . . . . . . . . . . . | 429 | | StackupFile/SupplierD...
# Customer Parts and Matching Manufacturer Parts > ## Appendix E Stackup Schema | StackupFile/SupplierData/Specs/Spec/Impedance/Differential_Broadside_Coupled/ TraceWidth. . . . . . . . . . . . . . ....
# Customer Parts and Matching Manufacturer Parts > ## Attributes The base of ODB++ stackup content that includes material, impedance, and a design-based stackup requirement, followed by any number of...
# Customer Parts and Matching Manufacturer Parts > ## StackupFile/EdaData - 'StackupFile/EdaData' on page 332 - 'StackupFile/SupplierData' on page 395 Contains all the stackup-required content as...
# Customer Parts and Matching Manufacturer Parts > ## Attributes 'StackupFile' on page 331 0-1 | Name | Type | Use | Default | Description ...
# Customer Parts and Matching Manufacturer Parts > ## StackupFile/EdaData/Specs - 'StackupFile/EdaData/Specs' on page 334 - 'StackupFile/EdaData/Stackup' on page 385 Contains a list of material spe...
# Customer Parts and Matching Manufacturer Parts > ## StackupFile/EdaData/Specs/Spec 'StackupFile/EdaData' on page 332 1 'StackupFile/EdaData/Specs/Spec' on page 335 An individual specificati...
# Customer Parts and Matching Manufacturer Parts > ## Attributes 'StackupFile/EdaData/Specs' on page 334 1-n | Name | Type | Use | Default | Description | ...
# Customer Parts and Matching Manufacturer Parts > ## StackupFile/EdaData/Specs/Spec/Material - 'StackupFile/EdaData/Specs/Spec/Material' on page 336 - 'StackupFile/EdaData/Specs/Spec/Impedance' on p...
# Customer Parts and Matching Manufacturer Parts > ## Attributes 'StackupFile/EdaData/Specs/Spec' on page 335 0-n | Name | Type | Use | Default | Description ...
# Customer Parts and Matching Manufacturer Parts > ## Children - 'StackupFile/EdaData/Specs/Spec/Material/Dielectric' on page 337 - 'StackupFile/EdaData/Specs/Spec/Material/Conductor' on page 342 - '...
# Customer Parts and Matching Manufacturer Parts > ## Attributes The definition of a specific piece of dielectric material. 'StackupFile/EdaData/Specs/Spec/Material' on page 336 0-1 | Name ...
# Customer Parts and Matching Manufacturer Parts > ## StackupFile/EdaData/Specs/Spec/Material/ Dielectric/Properties 'StackupFile/EdaData/Specs/Spec/Material/Dielectric/Properties' on page 339 Cont...
# Customer Parts and Matching Manufacturer Parts > ## Attributes 'StackupFile/EdaData/Specs/Spec/Material/Dielectric' on page 337 0-n | Name | Type | Use | Default | Descripti...
# Customer Parts and Matching Manufacturer Parts > ## Parent 'StackupFile/EdaData/Specs/Spec/Material/Dielectric/Properties/Property' on page 340 A specific property and the related material char...
# Customer Parts and Matching Manufacturer Parts > ## Attributes 1-n | Name | Type | Use | Default | Description ...
# Customer Parts and Matching Manufacturer Parts > ## Attributes The definition of a specific piece of conductive material. 'StackupFile/EdaData/Specs/Spec/Material' on page 336 0-1 | Name ...
# Customer Parts and Matching Manufacturer Parts > ## StackupFile/EdaData/Specs/Spec/Material/ Conductor/Properties 'StackupFile/EdaData/Specs/Spec/Material/Conductor/Properties' on page 344 Contai...
# Customer Parts and Matching Manufacturer Parts > ## Attributes 'StackupFile/EdaData/Specs/Spec/Material/Conductor' on page 342 0-n | Name | Type | Use | Default | Descriptio...
# Customer Parts and Matching Manufacturer Parts > ## Parent 'StackupFile/EdaData/Specs/Spec/Material/Conductor/Properties/Property' on page 345 A specific property and the related material chara...
# Customer Parts and Matching Manufacturer Parts > ## Attributes 1 | Name | Type | Use | Default | Description ...
# Customer Parts and Matching Manufacturer Parts > ## Attributes The thickness definition for the supplier-delivered dielectric or conductor material. 'StackupFile/SupplierData/Specs/Spec/Material'...
# Customer Parts and Matching Manufacturer Parts > ## Parent An Impedance specification defining the general impedance goal and physical characteristics. The Impedance is selected through the use of ...
# Customer Parts and Matching Manufacturer Parts > ## Attributes 0-n | Name | Type | Use | Default | Description ...
# Customer Parts and Matching Manufacturer Parts > ## Children - 'StackupFile/EdaData/Specs/Spec/Impedance/Single\_Ended' on page 351 - 'StackupFile/EdaData/Specs/Spec/Impedance/Differential\_Coplana...
# Customer Parts and Matching Manufacturer Parts > ## Attributes A representation of the single-ended impedance requirement. 'StackupFile/EdaData/Specs/Spec/Impedance' on page 348 0-n | Name ...
# Customer Parts and Matching Manufacturer Parts > ## StackupFile/EdaData/Specs/Spec/Impedance/ Single\_Ended/TraceWidth - 'StackupFile/EdaData/Specs/Spec/Impedance/Single\_Ended/TraceWidth' on page ...
# Customer Parts and Matching Manufacturer Parts > ## Attributes 'StackupFile/EdaData/Specs/Spec/Impedance/Single\_Ended' on page 351 1 | Name | Type | Use | Default | Description...
# Customer Parts and Matching Manufacturer Parts > ## Attributes Contains the list of layers that represent the reference planes in impedance calculation. 'StackupFile/EdaData/Specs/Spec/Impedance/...
# Customer Parts and Matching Manufacturer Parts > ## Attributes A representation of the differential Coplanar waveguide impedance requirement. 'StackupFile/EdaData/Specs/Spec/Impedance' on page 34...
# Customer Parts and Matching Manufacturer Parts > ## Children - 'StackupFile/EdaData/Specs/Spec/Impedance/Differential\_Coplanar\_Waveguide/ TraceWidth' on page 358 - 'StackupFile/EdaData/Specs/Spec...
# Customer Parts and Matching Manufacturer Parts > ## Attributes Contains the desired trace width to use for the target impedance. 'StackupFile/EdaData/Specs/Spec/Impedance/Differential\_Coplanar\_...
# Customer Parts and Matching Manufacturer Parts > ## Attributes Contains the desired spacing between copper for the target impedance. 'StackupFile/EdaData/Specs/Spec/Impedance/Differential\_Coplan...
# Customer Parts and Matching Manufacturer Parts > ## Attributes Contains the desired Coplanar spacing to use for the target impedance. 'StackupFile/EdaData/Specs/Spec/Impedance/Differential\_Copla...
# Customer Parts and Matching Manufacturer Parts > ## Parent Contains the desired Coplanar trace width to use for the target impedance. When using reference planes, this element is not to be defined....
# Customer Parts and Matching Manufacturer Parts > ## Attributes 0-1 | Name | Type | Use | Default | Description ...
# Customer Parts and Matching Manufacturer Parts > ## Attributes Contains the list of layers that represent the reference planes in impedance calculation. 'StackupFile/EdaData/Specs/Spec/Impedance/...
# Customer Parts and Matching Manufacturer Parts > ## Attributes A representation of the edge-coupled differential impedance requirement. 'StackupFile/EdaData/Specs/Spec/Impedance' on page 348 0-...
# Customer Parts and Matching Manufacturer Parts > ## Children - 'StackupFile/EdaData/Specs/Spec/Impedance/Differential\_Edge\_Coupled/ TraceWidth' on page 367 - 'StackupFile/EdaData/Specs/Spec/Imped...
# Customer Parts and Matching Manufacturer Parts > ## Attributes Contains the desired trace width to use for the target impedance. 'StackupFile/EdaData/Specs/Spec/Impedance/Differential\_Edge\_Coup...
# Customer Parts and Matching Manufacturer Parts > ## Attributes Contains the desired spacing between copper for the target impedance. 'StackupFile/EdaData/Specs/Spec/Impedance/Differential\_Edge\_...
# Customer Parts and Matching Manufacturer Parts > ## Attributes Contains the list of layers that represent the reference planes in impedance calculation. 'StackupFile/EdaData/Specs/Spec/Impedance/...
# Customer Parts and Matching Manufacturer Parts > ## Attributes A representation of the Coplanar single-ended waveguide impedance requirement. 'StackupFile/EdaData/Specs/Spec/Impedance' on page 34...
# Customer Parts and Matching Manufacturer Parts > ## Children - 'StackupFile/EdaData/Specs/Spec/Impedance/Single\_Ended\_Coplanar\_Waveguide/ CoplanarTraceWidth' on page 376 - 'StackupFile/EdaData/S...
# Customer Parts and Matching Manufacturer Parts > ## Attributes Contains the desired trace width to use for the target impedance. 'StackupFile/EdaData/Specs/Spec/Impedance/Single\_Ended\_Coplanar\...
# Customer Parts and Matching Manufacturer Parts > ## Attributes Contains the desired spacing between copper for the target impedance. 'StackupFile/EdaData/Specs/Spec/Impedance/Single\_Ended\_Copla...
# Customer Parts and Matching Manufacturer Parts > ## Parent Contains the desired coplanar trace width to use for the target impedance. When using reference planes, this element is not to be defined....
# Customer Parts and Matching Manufacturer Parts > ## Attributes 0-1 | Name | Type | Use | Default | Description ...
# Customer Parts and Matching Manufacturer Parts > ## Attributes Contains the list of layers that represent the reference planes in impedance calculation. 'StackupFile/EdaData/Specs/Spec/Impedance/...
# Customer Parts and Matching Manufacturer Parts > ## Attributes A representation of the broadside-coupled differential impedance requirement. 'StackupFile/EdaData/Specs/Spec/Impedance' on page 348...
# Customer Parts and Matching Manufacturer Parts > ## Children - 'StackupFile/EdaData/Specs/Spec/Impedance/Differential\_Broadside\_Coupled/ TraceWidth' on page 381 - 'StackupFile/EdaData/Specs/Spec/...
# Customer Parts and Matching Manufacturer Parts > ## Attributes Contains the desired trace width to use for the target impedance. 'StackupFile/EdaData/Specs/Spec/Impedance/Differential\_Broadside\...
# Customer Parts and Matching Manufacturer Parts > ## Attributes Contains the desired distance between the related conductors. 'StackupFile/EdaData/Specs/Spec/Impedance/Differential\_Broadside\_Cou...
# Customer Parts and Matching Manufacturer Parts > ## Attributes Contains the list of layers that represent the reference planes in impedance calculation. 'StackupFile/EdaData/Specs/Spec/Impedance/...
# Customer Parts and Matching Manufacturer Parts > ## Attributes Contains the stackup representation as delivered by the design source. 'StackupFile/EdaData' on page 332 1 | Name |...
# Customer Parts and Matching Manufacturer Parts > ## StackupFile/EdaData/Stackup/Group 'StackupFile/EdaData/Stackup/Group' on page 387 A stackup is created from Groups. A Group is a collection of ...
# Customer Parts and Matching Manufacturer Parts > ## Attributes 'StackupFile/EdaData/Stackup' on page 385 1-n | Name | Type | Use | Default | Description ...
# Customer Parts and Matching Manufacturer Parts > ## Attributes 'StackupFile/EdaData/Stackup/Group/Layer' on page 389 A Layer definition within the Group. 'StackupFile/EdaData/Stackup/Group' on ...
# Customer Parts and Matching Manufacturer Parts > ## Parent 'StackupFile/EdaData/Stackup/Group/Layer/SpecRef' on page 391 The list of Material and Impedance Specs, and conductor requirements for a...
# Customer Parts and Matching Manufacturer Parts > ## Attributes 0-n | Name | Type | Use | Default | Description | |-------------------...
# Customer Parts and Matching Manufacturer Parts > ## Parent - 'StackupFile/EdaData/Stackup/Group/Layer/SpecRef/Material' on page 392 - 'StackupFile/EdaData/Stackup/Group/Layer/SpecRef/Impedance' on ...
# Customer Parts and Matching Manufacturer Parts > ## Attributes 0-1 | Name | Type | Use | Default | Description ...
# Customer Parts and Matching Manufacturer Parts > ## Attributes Defines the impedance requirements for a layer. 'StackupFile/EdaData/Stackup/Group/Layer/SpecRef' on page 391 0-1 | Name ...
# Customer Parts and Matching Manufacturer Parts > ## StackupFile/SupplierData Represents instances of the manufacturing stackup, each with the required content determined by the supplier. This secti...
# Customer Parts and Matching Manufacturer Parts > ## Attributes 'StackupFile' on page 331 0-n | Name | Type | Use | Default | Description ...
# Customer Parts and Matching Manufacturer Parts > ## StackupFile/SupplierData/Specs - 'StackupFile/SupplierData/Specs' on page 397 - 'StackupFile/SupplierData/Stackup' on page 447 Contains a list ...
# Customer Parts and Matching Manufacturer Parts > ## StackupFile/SupplierData/Specs/Spec 'StackupFile/SupplierData' on page 395 1 'StackupFile/SupplierData/Specs/Spec' on page 398 An individ...
# Customer Parts and Matching Manufacturer Parts > ## Attributes 'StackupFile/SupplierData/Specs' on page 397 1-n | Name | Type | Use | Default | Description ...
# Customer Parts and Matching Manufacturer Parts > ## StackupFile/SupplierData/Specs/Spec/Material - 'StackupFile/SupplierData/Specs/Spec/Material' on page 399 - 'StackupFile/SupplierData/Specs/Spec/...
# Customer Parts and Matching Manufacturer Parts > ## Attributes 'StackupFile/SupplierData/Specs/Spec' on page 398 0-n | Name | Type | Use | Default | Description ...
# Customer Parts and Matching Manufacturer Parts > ## Children - 'StackupFile/SupplierData/Specs/Spec/Material/Dielectric' on page 400 - 'StackupFile/SupplierData/Specs/Spec/Material/Conductor' on pa...
# Customer Parts and Matching Manufacturer Parts > ## Attributes The definition of a specific piece of dielectric material. 'StackupFile/SupplierData/Specs/Spec/Material' on page 399 0-1 | Name...
# Customer Parts and Matching Manufacturer Parts > ## StackupFile/SupplierData/Specs/Spec/Material/ Dielectric/Properties 'StackupFile/SupplierData/Specs/Spec/Material/Dielectric/Properties' on page ...
# Customer Parts and Matching Manufacturer Parts > ## Attributes 'StackupFile/SupplierData/Specs/Spec/Material/Dielectric' on page 400 0-n | Name | Type | Use | Default | Desc...
# Customer Parts and Matching Manufacturer Parts > ## Parent 'StackupFile/SupplierData/Specs/Spec/Material/Dielectric/Properties/Property' on page 403 A specific frequency and the related materia...
# Customer Parts and Matching Manufacturer Parts > ## Attributes 1-n | Name | Type | Use | Default | Description ...
# Customer Parts and Matching Manufacturer Parts > ## Attributes The definition of a specific piece of conductive material. 'StackupFile/SupplierData/Specs/Spec/Material' on page 399 0-1 | Name...
# Customer Parts and Matching Manufacturer Parts > ## StackupFile/SupplierData/Specs/Spec/Material/ Conductor/Properties 'StackupFile/SupplierData/Specs/Spec/Material/Conductor/Properties' on page 40...
# Customer Parts and Matching Manufacturer Parts > ## Attributes 'StackupFile/SupplierData/Specs/Spec/Material/Conductor' on page 405 0-n | Name | Type | Use | Default | Descr...
# Customer Parts and Matching Manufacturer Parts > ## Parent 'StackupFile/SupplierData/Specs/Spec/Material/Conductor/Properties/PropertyName' on page 408 A specific property and the related mater...
# Customer Parts and Matching Manufacturer Parts > ## Attributes 1 | Name | Type | Use | Default | Description ...
# Customer Parts and Matching Manufacturer Parts > ## Attributes The thickness definition for the supplier-delivered dielectric or conductor material. 'StackupFile/EdaData/Specs/Spec/Material' on p...
# Customer Parts and Matching Manufacturer Parts > ## Parent An Impedance specification defining the general impedance goal and physical characteristics. The Impedance is selected through the use of ...
# Customer Parts and Matching Manufacturer Parts > ## Attributes 0-n | Name | Type | Use | Default | Description | |---------|-----------|----------|---...
# Customer Parts and Matching Manufacturer Parts > ## Children - 'StackupFile/SupplierData/Specs/Spec/Impedance/Single\_Ended' on page 413 - 'StackupFile/SupplierData/Specs/Spec/Impedance/Differen...
# Customer Parts and Matching Manufacturer Parts > ## Attributes A representation of the single-ended impedance requirement. 'StackupFile/SupplierData/Specs/Spec/Impedance' on page 411 0-n | Na...
# Customer Parts and Matching Manufacturer Parts > ## StackupFile/SupplierData/Specs/Spec/ Impedance/Single\_Ended/TraceWidth - 'StackupFile/SupplierData/Specs/Spec/Impedance/Single\_Ended/TraceWidth...
# Customer Parts and Matching Manufacturer Parts > ## Attributes 'StackupFile/SupplierData/Specs/Spec/Impedance/Single\_Ended' on page 413 1 | Name | Type | Use | Default ...
# Customer Parts and Matching Manufacturer Parts > ## Attributes Contains the list of layers that represent the reference planes in impedance calculation. 'StackupFile/SupplierData/Specs/Spec/Imped...
# Customer Parts and Matching Manufacturer Parts > ## Attributes A representation of the differential Coplanar waveguide impedance requirement. 'StackupFile/SupplierData/Specs/Spec/Impedance' on pa...
# Customer Parts and Matching Manufacturer Parts > ## Children - 'StackupFile/SupplierData/Specs/Spec/Impedance/Differential\_Coplanar\_Waveguide/ TraceWidth' on page 420 - 'StackupFile/SupplierData/...
# Customer Parts and Matching Manufacturer Parts > ## Attributes Contains the required trace width for the calculated impedance. - 'StackupFile/SupplierData/Specs/Spec/Impedance/Differential\_Copla...
# Customer Parts and Matching Manufacturer Parts > ## Attributes Contains the required spacing between copper for the calculated impedance. 'StackupFile/SupplierData/Specs/Spec/Impedance/Differenti...
# Customer Parts and Matching Manufacturer Parts > ## Attributes Contains the required Coplanar spacing for the calculated impedance. 'StackupFile/SupplierData/Specs/Spec/Impedance/Differential\_Co...
# Customer Parts and Matching Manufacturer Parts > ## Attributes Contains the required trace width for the calculated impedance. - 'StackupFile/SupplierData/Specs/Spec/Impedance/Differential\_Copla...
# Customer Parts and Matching Manufacturer Parts > ## Attributes Contains the list of layers that represent the reference planes in impedance calculation. 'StackupFile/SupplierData/Specs/Spec/Imped...
# Customer Parts and Matching Manufacturer Parts > ## Attributes A representation of the edge-coupled differential impedance requirement. 'StackupFile/SupplierData/Specs/Spec/Impedance' on page 411...
# Customer Parts and Matching Manufacturer Parts > ## Children - 'StackupFile/SupplierData/Specs/Spec/Impedance/Differential\_Edge\_Coupled/ TraceWidth' on page 429 - 'StackupFile/SupplierData/Specs/...
# Customer Parts and Matching Manufacturer Parts > ## Attributes Contains the required trace width for the calculated impedance. 'StackupFile/SupplierData/Specs/Spec/Impedance/Differential\_Edge\_C...
# Customer Parts and Matching Manufacturer Parts > ## Attributes Contains the required spacing between copper for the calculated impedance. 'StackupFile/SupplierData/Specs/Spec/Impedance/Differenti...
# Customer Parts and Matching Manufacturer Parts > ## Attributes Contains the list of layers that represent the reference planes in impedance calculation. 'StackupFile/SupplierData/Specs/Spec/Imped...
# Customer Parts and Matching Manufacturer Parts > ## Attributes A representation of the Coplanar single-ended waveguide impedance requirement. 'StackupFile/SupplierData/Specs/Spec/Impedance' on pa...
# Customer Parts and Matching Manufacturer Parts > ## Children - 'StackupFile/SupplierData/Specs/Spec/Impedance/ Single\_Ended\_Coplanar\_Waveguide/TraceWidth' on page 435 - 'StackupFile/SupplierData...
# Customer Parts and Matching Manufacturer Parts > ## Attributes Contains the required trace width for the calculated impedance. 'StackupFile/SupplierData/Specs/Spec/Impedance/Single\_Ended\_Coplan...
# Customer Parts and Matching Manufacturer Parts > ## Attributes Contains the required spacing between copper for the calculated impedance. 'StackupFile/SupplierData/Specs/Spec/Impedance/Single\_En...
# Customer Parts and Matching Manufacturer Parts > ## Parent Contains the required coplanar trace width for the calculated impedance. When using reference planes, this element is not to be defined. ...
# Customer Parts and Matching Manufacturer Parts > ## Attributes 0-1 | Name | Type | Use | Default | Description ...
# Customer Parts and Matching Manufacturer Parts > ## Attributes Contains the list of layers that represent the reference planes in impedance calculation. 'StackupFile/SupplierData/Specs/Spec/Imped...
# Customer Parts and Matching Manufacturer Parts > ## Attributes A representation of the broadside-coupled differential impedance requirement. 'StackupFile/SupplierData/Specs/Spec/Impedance' on pag...
# Customer Parts and Matching Manufacturer Parts > ## Children - 'StackupFile/SupplierData/Specs/Spec/Impedance/Differential\_Broadside\_Coupled/ TraceWidth' on page 443 - 'StackupFile/SupplierData/S...
# Customer Parts and Matching Manufacturer Parts > ## Attributes Contains the required trace width for the calculated impedance. 'StackupFile/SupplierData/Specs/Spec/Impedance/Differential\_Broadsi...
# Customer Parts and Matching Manufacturer Parts > ## Attributes Contains the required distance between the related conductors. - 'StackupFile/SupplierData/Specs/Spec/Impedance/Differential\_Broads...
# Customer Parts and Matching Manufacturer Parts > ## Attributes Contains the list of layers that represent the reference planes in impedance calculation. 'StackupFile/SupplierData/Specs/Spec/Imped...
# Customer Parts and Matching Manufacturer Parts > ## Attributes Contains the manufacturing stackup representation determined by the supplier. 'StackupFile/SupplierData' on page 395 1 | Name ...
# Customer Parts and Matching Manufacturer Parts > ## StackupFile/SupplierData/Stackup/Group 'StackupFile/SupplierData/Stackup/Group' on page 449 A stackup is created from Groups. A Group is a coll...
# Customer Parts and Matching Manufacturer Parts > ## Attributes 'StackupFile/SupplierData/Stackup' on page 447 1-n | Name | Type | Use | Default | Description ...
# Customer Parts and Matching Manufacturer Parts > ## Attributes 'StackupFile/SupplierData/Stackup/Group/Layer' on page 451 February 2020 A layer definition within the Group. 'StackupFile/Suppli...
# Customer Parts and Matching Manufacturer Parts > ## Parent 'StackupFile/EdaData/Stackup/Group/Layer/SpecRef' on page 391 The list of Material and Impedance Specs, and conductor requirements for a...
# Customer Parts and Matching Manufacturer Parts > ## Attributes 0-n | Name | Type | Use | Default | Description | |-------------------...
# Customer Parts and Matching Manufacturer Parts > ## Occurrence 'StackupFile/SupplierData/Stackup/Group/Layer/SpecRef/Material' on page 454 Defines the Material requirements for a layer. 'Stac...
# Customer Parts and Matching Manufacturer Parts > ## Attributes | Name | Type | Use | Default | Description ...
# Customer Parts and Matching Manufacturer Parts > ## Stackup Schema File This is the full schema file. ``` <?xml version="1.0" encoding="Windows-1252"?> <xs:schema xmlns:vc="http://www.w3.org/2007...
# Customer Parts and Matching Manufacturer Parts > ## Stackup Schema File ``` </xs:simpleType> <xs:simpleType name="FrequencyType"> <xs:restriction base="xs:string"> <xs:enumeration value="Hz"/> <xs:...
# Customer Parts and Matching Manufacturer Parts > ## Stackup Schema File ``` <xs:attribute name="FrequencyVal" type="xs:double" use="optional"> <xs:annotation> <xs:documentation>The value of the sin...
# Customer Parts and Matching Manufacturer Parts > ## Stackup Schema File ``` </xs:complexType> </xs:element> <xs:element name="Conductor" minOccurs="0"> <xs:annotation> <xs:documentation>A definitio...
# Customer Parts and Matching Manufacturer Parts > ## Stackup Schema File ``` <xs:documentation>This is mainly a historical means to specify copper thickness. The intended value to be used in this c...
# Customer Parts and Matching Manufacturer Parts > ## Stackup Schema File ``` </xs:annotation> </xs:attribute> <xs:attribute name="TolPercent" type="xs:boolean" use="optional" default="false"> <xs:an...
# Customer Parts and Matching Manufacturer Parts > ## Stackup Schema File ``` use="required"> <xs:annotation> <xs:documentation>Contains the target spacing for the related conductor. Default units i...
# Customer Parts and Matching Manufacturer Parts > ## Stackup Schema File ``` </xs:annotation> </xs:attribute> <xs:attribute name="ZoCalculatedOhms" type="xs:double" use="optional"> <xs:annotation> <...
# Customer Parts and Matching Manufacturer Parts > ## Stackup Schema File ``` <xs:complexType> <xs:attribute name="RefLayerName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The...
# Customer Parts and Matching Manufacturer Parts > ## Stackup Schema File ``` copper for the target impedance.</xs:documentation> </xs:annotation> <xs:complexType> <xs:attribute name="Val" type="xs:d...
# Customer Parts and Matching Manufacturer Parts > ## Stackup Schema File ``` </xs:element> <xs:element name="Differential_Broadside_Coupled" minOccurs="0" maxOccurs="unbounded"> <xs:annotation> <xs:...
# Customer Parts and Matching Manufacturer Parts > ## Stackup Schema File ``` xs:documentation> </xs:annotation> </xs:attribute> <xs:attribute name="ZoCalculatedOhms" type="xs:double" use="optional">...
# Customer Parts and Matching Manufacturer Parts > ## Stackup Schema File ``` </xs:annotation> </xs:attribute> </xs:complexType> </xs:element> </xs:sequence> </xs:complexType> </xs:element> <xs:eleme...
# Customer Parts and Matching Manufacturer Parts > ## Stackup Schema File ``` <xs:attribute name="ImpName" type="xs:string" use="required"> <xs:annotation> <xs:documentation>The name used for referen...
# Customer Parts and Matching Manufacturer Parts > ## Stackup Schema File ``` attribute are to be measured in. The default unit of measure is governed by StackupFile->DefaultUnits which is by defaul...
# Customer Parts and Matching Manufacturer Parts > ## Stackup Schema File ``` <xs:element name="Spec" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>An indiviual Spec defining a collection ...
# Customer Parts and Matching Manufacturer Parts > ## Stackup Schema File ``` use="optional"> <xs:annotation> <xs:documentation>A list of material definition that will most often be used when the Die...
# Customer Parts and Matching Manufacturer Parts > ## Stackup Schema File ``` </xs:annotation> </xs:attribute> <xs:attribute name="Finished_Thickness" type="xs:double" use="optional"> <xs:annotation>...
# Customer Parts and Matching Manufacturer Parts > ## Stackup Schema File <xs:complexType> <xs:sequence> <xs:element name="TraceWidth"> <xs:annotation> <xs:documentation>...
# Customer Parts and Matching Manufacturer Parts > ## Stackup Schema File ``` </xs:annotation> </xs:attribute> <xs:attribute name="Units_TraceWidth" type="UnitsType" use="optional" default="MIL"> <xs...
# Customer Parts and Matching Manufacturer Parts > ## Stackup Schema File ``` <xs:annotation> <xs:documentation>The Layer name used to reference the specific Impedance Type.</xs:documentation> </xs:a...
# Customer Parts and Matching Manufacturer Parts > ## Stackup Schema File ``` </xs:annotation> <xs:complexType> <xs:attribute name="RefLayerName" type="xs:string" use="required"> <xs:annotation> <xs:...
# Customer Parts and Matching Manufacturer Parts > ## Stackup Schema File ``` </xs:attribute> <xs:attribute name="Units" type="UnitsType" use="optional" default="MIL"> <xs:annotation> <xs:documentati...
# Customer Parts and Matching Manufacturer Parts > ## Stackup Schema File ``` trapezoidal ends with the top of the copper is narrower than the bottom. This attribute contains the width of the bottom ...
# Customer Parts and Matching Manufacturer Parts > ## Stackup Schema File ``` <xs:annotation> <xs:documentation>Units for InsertionLoss. Default is dB/Inch.</xs:documentation> </xs:annotation> </xs:...
# Customer Parts and Matching Manufacturer Parts > ## Stackup Schema File ``` </xs:complexType> </xs:element> </xs:sequence> <xs:attribute name="LayerName" type="xs:string" use="required"> <xs:annota...
# Customer Parts and Matching Manufacturer Parts > ## Stackup Schema File ``` default="SUBMITTED"> <xs:annotation> <xs:documentation>A stackup as one of five values, SELECTED indicates the stackup th...
# Customer Parts and Matching Manufacturer Parts > ## Appendix F Impedance Schema This appendix describes the elements, their related sub-elements, and the relevant attributes of the impedance file. ...
# Customer Parts and Matching Manufacturer Parts > ## Attributes The base of the Impedance content for the step. | Name | Type | Use | Default | Description ...
# Customer Parts and Matching Manufacturer Parts > ## Occurrence 'Impedances/Descriptor' on page 513 A list of impedance requirements for the trace features that bear the id attribute and reside ...
# Customer Parts and Matching Manufacturer Parts > ## Attributes | Name | Type | Use | Default | Description ...
# Customer Parts and Matching Manufacturer Parts > ## Children - 'Impedances/Descriptor/RequiredImpedance' on page 515 - 'Impedances/Descriptor/OriginalTraceWidth' on page 517 - 'Impedances/Descript...
# Customer Parts and Matching Manufacturer Parts > ## Attributes The required impedance values. 'Impedances/Descriptor' on page 513 0-1 | Name | Type | Use | Default | Descripti...
# Customer Parts and Matching Manufacturer Parts > ## Attributes Contains the original trace width for the required impedance. 'Impedances/Descriptor' on page 513 0-1 | Name | Type | Use...
# Customer Parts and Matching Manufacturer Parts > ## Attributes Contains the original spacing between copper for the required impedance. 'Impedances/Descriptor' on page 513 0-1 | Name | Type...
# Customer Parts and Matching Manufacturer Parts > ## Attributes Contains the list of layers that represent the reference planes in impedance calculation. 'Impedances/Descriptor' on page 513 0-2 ...
# Customer Parts and Matching Manufacturer Parts > ## Impedance Schema File This is the full schema file. ``` <?xml version="1.0" encoding="Windows-1252"?> <xs:schema xmlns:xs="http://www.w3.org/20...
# Customer Parts and Matching Manufacturer Parts > ## Impedance Schema File ``` </xs:element> </xs:sequence> <xs:attribute name="Id" type="xs:integer" use="required"> <xs:annotation> <xs:documentatio...
# Customer Parts and Matching Manufacturer Parts > ## Appendix G XML SimpleType Elements This appendix provides information on the SimpleType elements that specify constraints and information about a...
# Customer Parts and Matching Manufacturer Parts > ## Options The enumerations used by XML attributes. Controls whether the graphic representation of features is to be considered to be solid. - P...
# Customer Parts and Matching Manufacturer Parts > ## Options An enumerated list of layer types representing the purpose of the layer. - SIGNAL - A layer used for regular signal transfer - POWER\_G...
# Customer Parts and Matching Manufacturer Parts > ## Options An enumerated list of layer subtypes that refine the LayerType value. For example, a LayerType DRILL with a SubType BACKDRILL. Values a...
# Customer Parts and Matching Manufacturer Parts > ## SideType The context of layer. - BOARD - A layer that participates in the actual board production. - MISC - Any other layer that is used for dr...
# Customer Parts and Matching Manufacturer Parts > ## Options - NONE (default) - TOP - BOTTOM - INNER The units of measure. - MM - MICRON - INCH - MIL (default) An enumerated value indicating w...
# Customer Parts and Matching Manufacturer Parts > ## Options The impedance structure definition for the stripline, microstrip, or Coplanar waveguide areas. - STRIPLINE - PLANE\_LESS\_STRIPLINE - M...
# Customer Parts and Matching Manufacturer Parts > ## OtherType The generic type of dielectric materials. - PREPREG - CORE - OTHER - UNDEFINED The type of conductor. - COPPER - OTHER The unit...
# Customer Parts and Matching Manufacturer Parts > ## ImpedanceType - COVERLAY - COVERCOAT - STIFFENER - PRESSURE\_SENSITIVE\_ADHESIVE - OSP\_MASK - SILVER\_MASK - CARBON\_MASK - SOLDER\_MASK - PLAT...
# Customer Parts and Matching Manufacturer Parts > ## Options - SINGLE\_ENDED - DIFFERENTIAL\_COPLANAR\_WAVEGUIDED - DIFFERENTIAL\_EDGE\_COUPLE - SINGLE\_ENDED\_COPLANAR\_WAVEGUIDED - DIFFERENTIAL\_B...
# Customer Parts and Matching Manufacturer Parts > ## Options The stackup status as one of the following values: - SELECTED - The stackup is selected for use by the fabricator. - VALID - The stacku...
# Customer Parts and Matching Manufacturer Parts > ## Appendix H Frequently Asked Questions These are some frequently asked questions. | Question ...
# Customer Parts and Matching Manufacturer Parts > ## Appendix H Frequently Asked Questions ...
# Customer Parts and Matching Manufacturer Parts > ## Appendix H Frequently Asked Questions | Question ...
# Customer Parts and Matching Manufacturer Parts > ## Appendix H Frequently Asked Questions | Question ...